Safety of Administering Intravenous CT Contrast Agents Repeatedly or Using Both CT and MRI Contrast Agents on the Same Day: An Animal Study

  • Heejin Bae;Hyewon Oh;Ga Bin Park;Yong Eun Chung
    • Korean Journal of Radiology
    • /
    • 제25권3호
    • /
    • pp.257-266
    • /
    • 2024
  • Objective: To investigate molecular and functional consequences of additional exposures to iodine- or gadolinium-based contrast agents within 24 hours from the initial intravenous administration of iodine-based contrast agents through an animal study. Materials and Methods: Fifty-six Sprague-Dawley male rats were equally divided into eight groups: negative control, positive control (PC) with single-dose administration of CT contrast agent, and additional administration of either CT or MR contrast agents 2, 4, or 24 hours from initial CT contrast agent injection. A 12 µL/g of iodinated contrast agent or a 0.47 µL/g of gadolinium-based contrast agent were injected into the tail vein. Serum levels of blood urea nitrogen, creatinine, cystatin C (Cys C), and malondialdehyde (MDA) were measured. mRNA and protein levels of kidney injury molecule-1 (KIM-1) and neutrophil gelatinase-associated lipocalin (NGAL) were evaluated. Results: Levels of serum creatinine (SCr) were significantly higher in repeated CT contrast agent injection groups than in PC (0.21 ± 0.02 mg/dL for PC; 0.40 ± 0.02, 0.34 ± 0.03, and 0.41 ± 0.10 mg/dL for 2-, 4-, and 24-hour interval groups, respectively; P < 0.001). There was no significant difference in the average Cys C and MDA levels between PC and repeated CT contrast agent injection groups (Cys C, P = 0.256-0.362; MDA, P > 0.99). Additional doses of MR contrast agent did not make significant changes compared to PC in SCr (P > 0.99), Cys C (P = 0.262), and MDA (P = 0.139-0.771) levels. mRNA and protein levels of KIM-1 and NGAL were not significantly different among additional CT or MR contrast agent groups (P > 0.05). Conclusion: A sufficient time interval, probably more than 24 hours, between repeated contrast-enhanced CT examinations may be necessary to avoid deterioration in renal function. However, conducting contrast-enhanced MRI on the same day as contrast-enhanced CT may not induce clinically significant kidney injury.

Effect of Gd-based MR contrast agents on CT attenuation of PET/CT for quantitative PET-MRI study

  • Ko, In OK;Park, Ji Ae;Lee, Won Ho;Lim, Sang Moo;Kim, Kyeong Min
    • 대한방사성의약품학회지
    • /
    • 제1권2호
    • /
    • pp.130-136
    • /
    • 2015
  • We evaluate the influence of MR contrast agent on positron emission tomography (PET) image using phantom, animal and human studies. Phantom consisted of 15 solutions with the mixture of various concentrations of Gd-based MR contrast agent and fixed activity of [$^{18}F$]FDG. Animal study was performed using rabbit and two kinds of MR contrast agents. After injecting contrast agent, CT or MRI scanning was performed at 1, 2, 5, 10, and 20 minutes. PET image was obtained using clinical PET/CT scan, and attenuation correction was performed using the all CT images. The values of HU, PET activity and MRI intensity were obtained from ROIs in each phantom and organ regions. In clinical study, patients (n=20) with breast cancer underwent sequential acquisitions of early [$^{18}F$]FDG PET/CT, MRI and delayed PET/CT. In phantom study, as the concentration increased, the CT attenuation and PET activity also increased. However, there was no relationship between the PET activity and the concentration in the clinical dose range of contrast agent. In animal study, change of PET activity was not significant at all time point of CT scan both MR contrast agents. There was no significant change of HU between early and delayed CT, except for kidney. Early and delayed SUV in tumor and liver showed significant increase and decrease, respectively (P<0.05). Under the condition of most clinical study (< 0.2 mM), MR contrast agent did not influence on PET image quantitation.

PET/CT 시스템에서 CT 영상을 이용한 감쇠 보정 시 조영제가 PET 영상에 미치는 영향 (Impact of Contrast agent for Attenuation Correction Using CT Scan in PET/CT System)

  • 손혜경;;권윤영;봉정균;정해조;김희중
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.100-103
    • /
    • 2004
  • 본 연구에서는 PET/CT시스템에서 CT영상을 이용한 감쇠 보정 시 조영제가 PET영상에 미치는 영향을 관찰하기 위해 팬텀실험과 모의실험을 수행하였다. 다양한 농도로 희석한 조영제를 채운 플라스틱 병을 스티로폼을 이용하여 전신 팬텀 내에 고정시킨 후 투과 영상을 획득하였다. 모의실험을 위해 인체 기관 중 간을 가진 수학적 방출 스캔 맵과 투과 스캔 맵을 각각 만들었다. 간에서 조영제가 비 균일하게 증강된 투과 스캔 맵, 간에 조영제의 증강이 있는 투과스캔 맵과 없는 투과 스캔 맵, 간에 있는 종양에 조영제의 hypo-attenuating이 있는 투과 스캔 맵, 그리고 각각의 다른 조영제의 감쇠 정도를 가지는 간을 구현한 투과 스캔 맵을 각각 만들고 이를 이용하여 방출 영상을 감쇠 보정하였다. 팬텀실험을 통해 조영제의 농도에 따라 감쇠 정도가 달라짐을 확인하였다. 모의실험을 통해 감쇠 보정된 방출 영상이 조영제에 의해 영향을 받고, 또한 인공산물이 발생할 수 있음을 확인하였다. 따라서 조영제와 같은 물리적 인자가 감쇠 보정에 미치는 영향을 충분히 이해하고 정량적 분석 또는 진단 등에 고려하여야 할 것으로 생각한다.

  • PDF

CT 영상을 이용한 감쇠 보정 시 조영제가 PET 영상에 미치는 영향 (Impact of Contrast Agent for PET Images with CT-based Attenuation Correction)

  • 손혜경;;권윤영;정해조;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제16권4호
    • /
    • pp.192-201
    • /
    • 2005
  • 본 연구에서는 PET/CT 시스템에서 CT 영상을 이용한 감쇠 보정 시 조영제가 PET 영상에 미치는 영향을 관찰하기 위해 팬텀실험과 모의실험을 수행하였다. 다양한 농도로 희석한 조영제를 채운 플라스틱 병을 스티로폼을 이용하여 전신 팬텀 내에 고정시킨 후 투과 영상을 획득하였다 모의실험을 위해 인체 기관 중간을 가진 수학적 방출 맵과 투과 맵을 각각 생성하였다. 조영제의 비균일 증강, 조영제의 다양한 농도 및 분포 크기, 잡음 정도, 영상의 해상도, 재구성 알고리듬, 조영제의 저-감쇠, 그리고 각각 다른 시간상에 대한 조영제의 분포의 차이와 같은 다양한 인자들에 대하여 평가하였다. 팬텀실험으로부터 CT의 Hounsfield 값이 조영제의 농도 및 전압 값에 의존함을 확인할 수 있었다. 모의실험으로부터 조영제가 감쇠 보정한 PET 영상에서 인공산물을 생성하고 영상의 질을 떨어뜨리는 것을 관찰할 수 있었다. 조영제의 영향은 조영제의 농도 및 분포 크기, 잡음 정도, 영상의 해상도 등에 의해 영향을 받는 것으로 나타났다. 본 연구 결과들은 임상적 PET/CT 영상에서 조영제로 인해 발생할 수 있는 잠재적 문제를 충분히 이해하고 이를 고려해야 함을 보여 주었다.

  • PDF

Influence of Iodinated Magnetic Resonance Contrast Media and Isotope 99mTc on Changes of Computed Tomography Number

  • Kim, Sang-Beom;Lee, Jin-Hyeok;Ahn, Jae-Ouk;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.302-307
    • /
    • 2015
  • The purpose of the study was to identify how isotope and magnetic resonance imaging (MRI) contrast media impact on noise to computed tomography (CT) examination. For the study, divide the phantoms to two groups: 1) saline, saline + different kinds of contrast agent without $^{99m}Tc$ administration; 2) $^{99m}Tc$ administration: saline, saline + different kinds of contrast agent with $^{99m}Tc$ administration. CT contrast agent was used for Iopamidol$^{(R)}$ and Dotarem. And MRI contrast agent was used for Primovist$^{(R)}$ and Gadovist$^{(R)}$. To obtain an image, we used CT scanner. With an obtained image, we set the $1cm^2$ region of interest in the middle of bottle to measure the noise and CT number. As a result, there was no difference in CT number before and after inserting $^{99m}Tc$ into all contrast media including Normal Saline. However, when it comes to Noise, there was a difference before and after inserting $^{99m}Tc$ into every contrast media except MRI contrast media such as Primovist$^{(R)}$ and Gadovist$^{(R)}$.

일반촬영 자동노출제어장치 사용 시 잔존 CT 조영제와 MRI 조영제에 따른 면적선량의 상관성 연구 (A Study of The Correlation of The Area Dose with Residual CT Contrast Media and MRI Contrast Media during The Use of General Imaging Automatic Exposure Control System)

  • 홍찬우;박진훈;이정민;서영득
    • 한국방사선학회논문지
    • /
    • 제10권8호
    • /
    • pp.619-627
    • /
    • 2016
  • 본 연구에서는 일반촬영에서 자동노출제어장치를 이용하여 검사할 때 체내에 잔존하는 CT 조영제와 MRI 조영제가 면적선량에 미치는 영향에 대해 알아보고자 한다. 복부 두께의 파라핀 팬텀 중앙에 사각형의 홀을 만든 후 CT 조영제, MRI 조영제를 각각 식염수 대 조영제 희석 비율, 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6, 3:7, 2:8, 1:9, 0:10 %의 비율로 희석하였다. 각 실험은 KUB 촬영의 적정 조건인 78kVp, 320mA로 설정 후 자동노출제어장치를 이용하여 희석 비율 당 총 30회씩의 검사를 하였고, 각 조영제의 희석 비율에 따른 면적선량, 노출지수에 대해 평균 비교와 상관분석을 하였다. 그 결과, CT 조영제와 MRI 조영제는 희석 비율에 따라 면적선량이 다르게 나타났고(p<0.05), 희석 비율이 증가함에 따라 CT 조영제와 MRI 조영제는 면적선량이 증가하는 것으로 나타났다(p<0.05). 각 검사에서 노출지수는 제조사 권고 사항인 200-800 EI값을 나타냈으며, 노출지수와 면적선량은 면적선량이 증가할수록 노출지수도 증가하였다(p<0.05). 결론적으로 CT 조영제와 MRI 조영제는 모두 자동노출제어장치를 사용하는 일반촬영 검사에서 면적선량을 증가시키는 것을 확인하였다. 따라서 CT와 MRI 검사에서 조영제를 사용한 후 일반촬영 검사를 할 때에는 조영제가 충분히 배설된 후 시행하여야 할 것으로 사료된다.

CT 조영제가 MR 조영제의 이완율에 미치는 영향 (Effects of CT Contrast Medium on the Relaxation Rate of MR Contrast Medium)

  • 권순용;강충환;정현근;박진서;김성호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.103-107
    • /
    • 2018
  • In MR, the iodine CT contrast medium reduces the T1 and T2 relaxation times of the substance, resulting in a change in signal intensity. This study aimed to measure the relaxation rate of MR contrast medium with or without diluting CT contrast medium and analyzed the effect of CT contrast medium. Undiluted Gadoteridol solution was diluted with saline to prepare MR contrast medium phantoms with various levels of Gadoteridol concentrations. Moreover, undiluted Iomeprol was mixed with the prepared MR contrast medium phantoms at 1:1 ratio to make MR contrast medium phantoms with containing CT contrast medium for the experiment. T1 and T2 mappings were conducted to quantitatively evaluate the relaxation time and relaxation rate of these phantoms. The results showed that the T1 and T2 relaxation time and relaxation rate of MR contrast medium diluted with CT contrast medium were significantly (p<0.05) shorter than those of MR contrast medium not diluted with CT contrast medium. The results of this study imply that, when MR contrast medium shall be used after injecting CT contrast medium, CT contrast medium should be discharged enough. Moreover, it would be desirable to conduct CT test after taking MRI test in order to reduce the effects of CT contrast medium on MR contrast medium.

CT 조영제를 이용한 차폐체에 대한 연구 (Study on Shielding using CT Contrast Medium)

  • 강헌효;김동현
    • 한국방사선학회논문지
    • /
    • 제12권5호
    • /
    • pp.693-698
    • /
    • 2018
  • 현재 의료환경에서 영상의학 검사 시 의료 방사선을 차폐하기 위한 차폐체는 납가운, 납유리가 대부분이다. 이러한 차폐체의 주성분인 납은 납중독과 경량화의 한계, 고가라는 제한점이 있다. 납차폐체 대신 대체 물질로 조영제로 쓰이고 있는 요오드 성분은 방사선을 흡수하는 특성을 지니고 있어 차폐체로써 효과가 있을 것이라 예측하고 있다. 이에 본 연구에서는 투시 검사 시 기존의 납유리 대신 임상에서 사용하고 남은 CT 조영제로 채워진 아크릴판을 이용하여 차폐유무를 평가 하였다. 그 결과 산란선 선량 평가 시 차폐를 하지 않았을 때 보다 CT조영제로 채워진 아크릴판은 7배 이상 차폐효과가 나타났다. 따라서 기존의 납유리 대신 요오드 성분으로 이루어진 CT 조영제가 차폐체로써 활용될 것이라 기대된다.

18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과 (The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning)

  • 차상영;조용귀;이용기;송종남;최남길
    • 한국방사선학회논문지
    • /
    • 제10권4호
    • /
    • pp.255-261
    • /
    • 2016
  • PET/CT 촬영에서 정량분석에 영향을 주는 다양한 인자 중 현재 상품화된 CT 조영제와 MRI 조영제의 종류별 각 성분의 특성에 따른 SUV의 변화를 비교 분석하고자 하였다. 실험장비는 Discovery 690 PET/CT(Ge)와 NEMA NU2-1994 PET phantom를 이용하였고, 팬텀에 증류수 2/3를 채워 넣은 후 방사성동위원소(18F-FDG 37 MBq)와 각각의 CT와 MRI 조영제를 순차적으로 주입하여 팬텀을 고르게 교반하고 다시 증류수를 가득 채운 후 기포가 생기지 않게 하였다. 방출스캔은 FDG 또는 FDG와 혼합한 조영제를 넣고 40분에 15분 동안 스캔하였으며, 투과스캔은 CT로 관전압 120 kVp, 관전류 40 mA, 회전시간 0.5 sec, 단면두께 3.27 mm, DFOV 30 cm의 조건으로 스캔하였다. 분석방법으로 정량분석은 각각 10, 15, 20, 25, 30번째 slice에서 region of interest (ROI)를 설정하여 각각 SUVmean, SUVmax를 구하였다. 결과적으로 순수 FDG 영상과 비교에서 MRI 조영제를 혼합한 3종류의 영상 모두에서 SUVmean가 높게 측정되었으나 통계적 유의성은 없었고, SUVmax 에서는 유의한 결과를 얻었다. 또한 4종류의 CT 조영제 영상은 SUVmean, SUVmax 모두 유의한 결과를 얻었다. PET/CT는 영상의 정확도를 위해 감쇠 보정은 다양한 방법으로 시행되고 있지만 CT와 MRI 조영제는 감쇠보정 시 영상의 왜곡에 의한 진단적 가치를 저하시킬 수 있다. 이러한 이유로 진료 당일 여러 종류의 검사를 시행하기 전 반드시 선행되어야 할 검사를 선별하여 서로 영향을 주지 않도록 함으로서 고객에게 차별화된 양질의 의료서비스를 제공해야 한다.

The Effect of Contrast Agent on the Change of Hepatic Uptake of 99mTc-Mebrofenin in Patients with Liver Transplantation

  • Seung-Hun Yeom;Sang-Hyeong Kil;Yeong-Hyeon Lim;Gwang-Yeol Park;Gyeong-Nam Cho;Seong-Muk Cho;Ji-Ho Seong
    • 핵의학기술
    • /
    • 제28권1호
    • /
    • pp.23-29
    • /
    • 2024
  • Purpose: 99mTc-mebrofenin hepatobiliary scintigraphy (HBS) is an important and clinically useful diagnostic imaging study for detecting complications after liver transplantation. CT contrast agents due to their high atomic numbers, lead to a decrease in gamma ray count rates. This study investigated the impact of CT contrast agents on the uptake of 99mTc-mebrofenin in the liver. Materials and Methods: The quantitative HBS was performed on sixty-two liver transplantation patients (male:female=36:26), with a mean age of 59.4±6.4 years. Statistical comparison of hepatic uptake reduction ratio (HURR%) before and after the injection of CT contrast agents was performed using a paired t-test. Results: Hepatic uptake of the reduction ratio was 94.47±3.65% for the pre-CT contrast agents and 92.17±4.00% for the post-CT contrast agents. HURR% after CT contrast agent injection showed a statistically significant difference compared to before the injection (t=11.09, P<0.001). Conclusion: It will be necessary to pay attention when examining the HBS of patients with liver transplantation after the injection of CT contrast medium. It is advisable to schedule the examination on a different day to prevent residual contrast medium in the body from interfering with the quantitative evaluation of the nuclear medicine examination.