• Title/Summary/Keyword: CT 시편

Search Result 95, Processing Time 0.026 seconds

Effects of Specimen Size and Side-groove on the Results of J-R Fracture Toughness Test for LBB Evaluation (LBB 평가를 위한 J-R 파괴인성시험 결과에 미치는 시편 형상과 측면 홈의 영향)

  • Kim, Jin Weon;Choi, Myung Rak;Oh, Young Jin;Park, Heung Bae;Kim, Kyung Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.7
    • /
    • pp.729-736
    • /
    • 2015
  • In this study, the effects of specimen size and side-groove on the results of the J-R test for leak-before-break (LBB) evaluation were investigated. A series of J-R tests were conducted at both RT and $316^{\circ}C$, using three different sizes of compact tension (CT) specimens machined from SA508 Gr.1a piping material: 12.7 mm-thick 1T-CT, 25.4 mm-thick 1T-CT, and 25.4 mm-thick 2T-CT with and without side-groove. The results showed that side-grooving reduced the J-R curve for all specimens and the effect of side-grooving was more significant at $316^{\circ}C$ than at RT. As the thickness of the specimens decreased and the width of the specimens increased, the J-R curve slightly decreased at RT but it increased at $316^{\circ}C$. However, the variation in the J-R curve of SA508 Gr.1a with the thickness and width of CT specimen was insignificant.

A Proposal of Round Specimen for the Determination of Crack Arrest Toughness (균열정지 인성치결정을 위한 원형시편의 제안)

  • 이억섭;김상철;송정일;이규철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.5
    • /
    • pp.1472-1478
    • /
    • 1991
  • 본 연구에서는 Rectangular Computer Tension(CT) 시편을 수정하여 만든 표준 시편인 MRL-CLWL시편(material research laboratorycrack line wedge loaded specimen )으로 균열정지 인성치를 결정하였다. 그리고 CT시편과 같은 효과를 갖는 Newman등 이 제안한 round compact tension(RCT)시편을 수정한 Round-CLWL 시편으로 균열정지인 성치를 결정하여 상호 비교평가하였다. Round-CLWL 시편은 시편제작시 round-bar를 절단하여 시편으로 가공할 수 있으므로 가공성이 좋으며 따라서 가공비가 적게 든다. 특히 균열 위치 및 방향을 임의로 선택하여 가공하기가 용이하므로 방향성이 있는 소 재의 균열정지 인성치를 결정하는 데 매우 편리한 시편이라 생각된다. 본 논문에서 는 Round-CLWL 시편으로 $K_{1a}$ 값을 계산하는데 필요한 형상계수를 결정하였으며, Polymethylmethacrylate(PMMA)를 사용하여 Round-CLWL 시편 채택의 타당성 확인을 위 한 MRL-CLWL과 Round-CLWL 시편 채택의 타당성 확인을 위한 MRL-CLWL과 Round-CLWL시 편의 $K_{1a}$결정 실험을 하였다.하였다.

Development of Triaxial Cells Operable with In Situ X-ray CT for Hydro-Mechanical Laboratory Testing of Rocks (원위치 X-ray CT 촬영이 가능한 암석의 수리-역학 실험용 삼축셀 개발)

  • Zhuang, Li;Yeom, Sun;Shin, Hyu-Soung
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.9
    • /
    • pp.45-55
    • /
    • 2020
  • X-ray computed tomography (CT) is very useful for the quantitative evaluation of internal structures, particularly defects in rock samples, such as pores and fractures. In situ CT allows 3D imaging of a sample subjected to various external treatments such as loading and therefore enables observation of changes that occur during the loading process. We reviewed state-of-the-art of in situ CT applications for geomaterials. Two triaxial cells made using relatively low density but high strength materials were developed aimed at in situ CT scanning during hydro-mechanical laboratory testing of rocks. Preliminary results for in situ CT imaging of granite and sandstone samples with diameters ranging from 25 mm to 50 mm show a resolution range of 34~105 ㎛ per pixel pitch, indicating the feasibility of in situ CT observations for internal structural changes in rocks at the micrometer scale. Potassium iodide solution was found to improve the image contrast, and can be used as an injection fluid for hydro-mechanical testing combined with in situ CT scanning.

Investigation of Microstructural Characteristics of Foamed Concrete with Different Densities (미세구조 분석방법을 활용한 서로 다른 밀도를 가진 기포콘크리트 특성 분석)

  • Chung, Sang-Yeop;Jo, Su-Sung;Oh, Seo-Eun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • A set of foamed concrete specimens with different densities were prepared, and several microscopic techniques, such as scanning electron microscope (SEM) and X-ray micro-computed tomography (micro-CT) were used to characterize the foamed specimens. The pore and solid characteristics of the specimens at different ages were examined to investigate the effect of aging on the materials. The compressive strength and the thermal conductivity of the foamed specimens were also evaluated, and the relationship between the material characteristics and properties was integrated to identify the effect of density and aging on the material properties.

Evaluation of Void Distribution on Lightweight Aggregate Concrete Using Micro CT Image Processing (Micro CT 이미지 분석을 통한 경량 골재 콘크리트의 공극 분포 분석)

  • Chung, Sang-Yeop;Kim, Young-Jin;Yun, Tae Sup;Jeon, Hyun-Gyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2A
    • /
    • pp.121-127
    • /
    • 2011
  • Spatial distribution of void space in concrete materials strongly affects mechanical and physical behaviors. Therefore, the identification of characteristic void distribution helps understand material properties and is essential to estimate the integrity of material performance. The 3D micro CT (X-ray microtomography) is implemented to examine and to quantify the void distribution of a lightweight aggregate concrete using an image analysis technique and probabilistic approach in this study. The binarization and subsequent stacking of 2D cross-sectional images virtually create 3D images of targeting void space. Then, probability distribution functions such as two-point correlation and lineal-path functions are applied for void characterization. The lightweight aggregates embedded within the concrete are individually analyzed to construct the intra-void space. Results shows that the low-order probability functions and the density distribution based on the 3D micro CT images are applicable and useful methodology to characterize spatial distribution of void space and constituents in concrete.

Effect of Titanium Prosthesis on Computed Tomography Measurements of Bone Mineral Density

  • Han, S.M.;Zude Feng
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.177-182
    • /
    • 1998
  • This study investigated the effects of a titanium prosthesis, malalignment, field of view, and distal flare of titanium prosthesis on computed tomography( CT) measurements of home mineral density. Eight femora and eight tibiae from fresh male cadavers were used. Fifteen pieces of cancellous bone from the proximal tibiae were milled into rectangular parallelepipeds. Parallelepipeds and femors were scanned with and without titanium prosthesis when centered in the gantry of the CT scanner and malaligned, respectively. Image data were then reconstructed with field of view of 10 and 30 cm. Bone mineral density(BMD) values were obtained from CT images using C-MED software. The effects of titanium prosthesis, malalignmetn, and field of view were investigated. When bone was centered in the gantry of the CT scanner, the mean relative difference of BMD measurements caused by a titanium prosthesis was less than 1% for both cortical and cancellous bone. Field of view had negligible effect on BMD measurements as well. Malalignment and distal flare of prosthesis, however, caused a significant difference in BMD measurements(p<0.0001). The titanium prosthesis did not interfere with malalignment combining the existence of a titnium prosthesis on BMD measurements was significant.

  • PDF

A Study of the Mechanical Properties of Human Trabecular Bone by Spherical Indentation Test (구형압입시험을 통한 망상골의 기계적 물성 연구)

  • 배태수;김정규;이태수;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.419-424
    • /
    • 2001
  • We intended to evaluate the Young's modulus of trabecular bone of a human distal femur by spherical Indentation test and CT images and to quantify relationships between the direction of load, density. and Young's modulus. The specimens were scanned at 1 mm intervals on CT scanner After scanning the bones were sectioned with diamond saw. producing 8mm cubes of trabecular bone. The tubes were mechanically tested in inferior-superior(IS), anterior-posterior(AP). and medial-lateral(ML) direction with custom-made device. After testing, the real apparent density of specimens were measured. The results of this study showed that the IS modulus was significant1y greater than both the AP and ML modulus and the AP modulus was also greater than ML modulus significantly(p〈0.01) A significant Power relationship between the apparent density and the modulus was also found.

  • PDF

Evaluation of Air Permeability of Virtual Cement Paste Specimen with Linear Void Ratio Gradient Constructed using Stochastic Optimization (확률적 최적화를 활용한 연속적인 공극비 기울기를 갖는 시멘트 풀 가상 시편 제작 및 투기율 분석)

  • Kim, Se-Yun;Han, Tong-Seok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.5
    • /
    • pp.463-469
    • /
    • 2016
  • In this study, a virtual specimen with a linear continuous gradient of void ratio (FGM: Functional Graded Material) is constructed using low-order probability functions of two real cement paste specimens. Two real specimens with difference void ratios are taken from X-ray CT to construct the virtual specimen. A virtual specimen with a gradient void distribution, whose average void ratio is between void ratios of two homogeneous real specimens, is constructed using a stochastic optimization approach. The void ratio distribution is assumed to be linear, and continuously varies in the vertical direction. In this study, a gradient term of void ratio is incorporated into the objective function as well as low-order probability functions from the previous research. To confirm the effect of gradient void distribution on the material response, air permeability is evaluated using finite element analysis. The analysis results are compared with experimental results, and confirm the effect of gradient void distribution on permeability.

Quantitative Evaluation of Concrete Damage by X-ray CT Methods (마이크로 포커스 X-ray CT를 이용한 콘크리트 손상균열의 정량적 평가)

  • Jung, Jahe
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.455-463
    • /
    • 2018
  • This study developed a method to quantitatively measure the size of cracks in concrete using X-ray CT images. We prepared samples with a diameter of 50 mm and a length of 100 mm by coring cracked concrete block that was obtained by chipping. We used a micro-focus X-ray CT, then applied the 3DMA method (3 Dimensional Medial axis Analysis) to the 3D CT images to find effective parameters for damage assessment. Finally, we quantitatively assessed the damage based on sample locations, using the damage assessment parameter. Results clearly show that the area near the chipping surface was damaged to a depth of 3 cm. Furthermore, X-ray methods can be used to evaluate the porosity index, burn number, and medial axis, which are used to estimate the damage to the area near the chipping surface.

A Study on Accuracy of J-Resistance Curves Measured with Curved Compact Tension Specimen of Zr-2.5Nb Pressure Tube (Zr-2.5Nb 압력관의 휘어진 CT시편으로 측정한 J 저항곡선의 정확도에 관한 연구)

  • Yoon, Kee-Bong;Park, Tae-Gyu;Kim, Young-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.11
    • /
    • pp.1986-1996
    • /
    • 2003
  • Methodology based on the elastic-plastic fracture mechanics has been widely accepted in predicting the critical crack length(CCL) of pressure tubes of CANDU nuclear plants. A conservative estimate of CCL is obtained by employing the J-resistance curves measured with the specimens satisfying plane strain condition as suggested in the ASTM standard. Due to limited thickness of the pressure tubes the curved compact tension(CT) specimens taken out from tile pressure tube have been used in obtaining J-resistance curves. The curved CT specimen inevitably introduce slant fatigue crack during precracking. Hence, effect of specimen geometry and slant crack on J-resistance curve should be explored. In this study, the difference of J integral values between the standard CT specimens satisfying plane strain condition and the nonstandard curved CT with limited thickness (4.2mm) is estimated using finite element analysis. The fracture resistance curves of Zr-2.5Nb obtained previously by other authors are critically discussed. Various finite element analysis were conducted such as 2D analysis under plane stress and plane strain conditions and 3D analysis for flat CT, curved CT with straight crack and curved CT with slant crack front. J-integral values were determined by local contour integration near the crack tip, which was considered as accurate J-values. J value was also determined from the load versus load line displacement curve and the J estimation equation in the ASTM standard. Discrepancies between the two values were shown and suggestion was made for obtaining accurate J values from the load line displacement curves obtained by the curved CT specimens.