• Title/Summary/Keyword: CT (computed tomography)

Search Result 2,650, Processing Time 0.037 seconds

Incidental Abnormal FDG Uptake in the Prostate on 18-fluoro-2-Deoxyglucose Positron Emission Tomography-Computed Tomography Scans

  • Kang, Pil Moon;Seo, Won Ik;Lee, Sun Seong;Bae, Sang Kyun;Kwak, Ho Sup;Min, Kweonsik;Kim, Wansuk;Kang, Dong Il
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8699-8703
    • /
    • 2014
  • 18-fluoro-2-deoxyglucose positron emission tomography-computed tomography ($^{18}F$-FDG PET/CT) scans are commonly used for the staging and restaging of various malignancies, such as head and neck, breast, colorectal and gynecological cancers. However, the value of FDG PET/CT for detecting prostate cancer is unknown. The aim of this study was to evaluate the clinical value of incidental prostate $^{18}F$-FDG uptake on PET/CT scans. We reviewed $^{18}F$-FDG PET/CT scan reports from September 2009 to September 2013, and selected cases that reported focal/diffuse FDG uptake in the prostate. We analyzed the correlation between $^{18}F$-FDG PET/CT scan findings and data collected during evaluations such as serum prostate-specific antigen (PSA) levels, digital rectal examination (DRE), transrectal ultrasound (TRUS), and/or biopsy to confirm prostate cancer. Of a total of 18,393 cases, 106 (0.6%) exhibited abnormal hypermetabolism in the prostate. Additional evaluations were performed in 66 patients. Serum PSA levels were not significantly correlated with maximum standardized uptake values (SUVmax) in all patients (rho 0.483, p=0.132). Prostate biopsies were performed in 15 patients, and prostate cancer was confirmed in 11. The median serum PSA level was 4.8 (0.55-7.06) ng/mL and 127.4 (1.06-495) ng/mL in the benign and prostate cancer groups, respectively. The median SUVmax was higher in the prostate cancer group (mean 10.1, range 3.8-24.5) than in the benign group (mean 4.3, range 3.1-8.8), but the difference was not statistically significant (p=0.078). There was no significant correlation between SUVmax and serum PSA, prostatic volume, or Gleason score. $^{18}F$-FDG PET/CT scans did not reliably differentiate malignant or benign from abnormal uptake lesions in the prostate, and routine prostate biopsy was not usually recommended in patients with abnormal FDG uptake. Nevertheless, patients with incidental prostate uptake on $^{18}F$-FDG PET/CT scans should not be ignored and should be undergo further clinical evaluations, such as PSA and DRE.

Comparison of the observer reliability of cranial anatomic landmarks based on cephalometric radiograph and three-dimensional computed tomography scans (삼차원 전산화단층촬영사진과 측모두부 방사선규격사진의 계측자에 따른 계측오차에 대한 비교분석)

  • Kim, Jae-Young;Lee, Dong-Keun;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.4
    • /
    • pp.262-269
    • /
    • 2010
  • Introduction: Accurate diagnosis and treatment planning are very important for orthognathic surgery. A small error in diagnosis can cause postoperative functional and esthetic problems. Pre-existing 2-dimensional (D) chephalogram analysis has a high likelihood of error due to its intrinsic and extrinsic problems. A cephalogram can also be inaccurate due to the limited anatomic points, superimposition of the image, and the considerable time and effort required. Recently, an improvement in technology and popularization of computed tomography (CT) provides patients with 3-D computer based cephalometric analysis, which complements traditional analysis in many ways. However, the results are affected by the experience and the subject of the investigator. Materials and Methods: The effects of the sources human error in 2-D cephalogram analysis and 3-D computerized tomography cephalometric analysis were compared using Simplant CMF program. From 2008 Jan to 2009 June, patients who had undergone CT, cephalo AP, lat were investigated. Results: 1. In the 3 D and 2 D images, 10 out of 93 variables (10.4%) and 11 out 44 variables (25%), respectively, showed a significant difference. 2. Landmarks that showed a significant difference in the 2 D image were the points frequently superimposed anatomically. 3. Go Po Orb landmarks, which showed a significant difference in the 3 D images, were found to be the artificial points for analysis in the 2 D image, and in the current definition, these points cannot be used for reproducibility in the 3 D image. Conclusion: Generally, 3-D CT images provide more precise identification of the traditional cephalometric landmark. Greater variability of certain landmarks in the mediolateral direction is probably related to the inadequate definition of the landmarks in the third dimension.

A Case of Complete Response with FOLFOX Based Neo-adjuvant Chemotherapy in Advanced Gastric Cancer with Lymph Node Metastasis (림프절 전이가 동반된 진행성 위암 환자에서 수술 전 항암요법으로 시행한 FOLFOX 치료로 완전 관해를 보인 1례)

  • Myung Hee Kim;Hyun Yong Jeong;Hee Seok Moon;Jae Kyu Sung;Sun Hyun Kang;Ju Seok Kim
    • Journal of Digestive Cancer Research
    • /
    • v.6 no.1
    • /
    • pp.40-44
    • /
    • 2018
  • A 77-year-old man presented with abdominal discomfort and was diagnosed as Borrmann type 3 advanced gastric cancer with multiple lymph node metastases. An abdominal computed tomography (CT) and positron emission tomography-computed tomography (PET-CT) showed AGC, clinical stage IIIC (T4aN3M0). We started neo-adjuvant chemotherapy with FOLFOX (5-fluorouracil (5-FU))+Leucovorin+Oxaliplatin). After 3 cycles of FOLFOX chemotherapy, follow-up endoscopy showed remarkable improvement. Primary lesion and metastatic lymph nodes decreased size on follow up computed tomography (CT). The patient underwent radical total gastrectomy with esophagojejunostomy and histopathology revealed no remnant malignant cells at previous primary cancer lesion. The patient has currently completed his 3 cycle of adjuvant chemotherapy without recurrence. After an abdominal CT response assessment, further course of therapy will be decided.

  • PDF

Early CT Findings of Coronavirus Disease 2019 (COVID-19) in Asymptomatic Children: A Single-Center Experience

  • Lan Lan;Dan Xu;Chen Xia;Shaokang Wang;Minhua Yu;Haibo Xu
    • Korean Journal of Radiology
    • /
    • v.21 no.7
    • /
    • pp.919-924
    • /
    • 2020
  • Objective: The current study reported a case series to illustrate the early computed tomography (CT) findings of coronavirus disease 2019 (COVID-19) in pediatric patients. Materials and Methods: All pediatric patients who were diagnosed with COVID-19 and who underwent CT scan in Zhongnan Hospital of Wuhan University from January 20, 2020 to February 28, 2020 were included in the current study. Data on clinical and CT features were collected and analyzed. Results: Four children were included in the current study. All of them were asymptomatic throughout the disease course (ranging from 7 days to 15 days), and none of them showed abnormalities in blood cell counts. Familial cluster was the main transmission pattern. Thin-section CT revealed abnormalities in three patients, and one patient did not present with any abnormal CT findings. Unilateral lung involvement was observed in two patients, and one patient showed bilateral lung involvement. In total, five small lesions were identified, including ground-glass opacity (n = 4) and consolidation (n = 1). All lesions had ill-defined margins with peripheral distribution and predilection of lower lobe. Conclusion: Small patches of ground-glass opacity with subpleural distribution and unilateral lung involvement were common findings on CT scans of pediatric patients in the early stage of the disease.

Studies on Quantitative Analysis of Salivary Gland using Computed Tomography (전산화단층사진을 이용한 타액선의 정량분석에 관한 연구)

  • Lee Sang-Chul;Lee Sam-Sun;Heo Min-Suk;Choi Soon-Chul;Park Tae-Won;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.209-221
    • /
    • 1999
  • Purpose: The purpose of this study was to calculate the size and CT number of both normal parotid and submandibular gland. and evaluate their relation to sex, age and obesity using computed tomography. Materials and Methods: The computed tomography was performed parallel to the Frankfurt plane in 46 subjects with healthy salivary gland. The subjects were divided into the three groups (young, middle. old) according to their ages. The size of salivary gland was determined as maximum cross-sectional area and the CT number of salivary gland was determined as the mean CT number of three ROI's. The body mass index was calculated from weight and height. Results: The mean maximum cross-sectional area was 7.79(±1.25)cm² on parotid gland and 4.12(±0.83) cm² on submandibular gland. The mean CT number was -4.43(±23.87) HU on parotid gland and 50.01(±15.63) HU on submandibular gland. There was decreasing pattern of the maximum cross-sectional area of submandibular gland and the CT number of both parotid and submandibular gland according to age(p<0.05). As the body mass index increased. the maximum cross-sectional area of parotid gland increased and CT number of both parotid and submandibular gland decreased(p<0.05). The maximum cross-sectional area of submandibular gland in male was larger than that in female(p<0.05). As the maximum cross-sectional area and CT number of left salivary gland increased. those of right gland increased(p<0.05). Conclusion : Intra-individual differences in salivary gland size and CT number is considered in the age and individual obesity.

  • PDF

Morphological Analysis of the Sinus Lateral Wall using Computed Tomography (전산화단층촬영법을 이용한 상악동 측벽의 형태학적 분석)

  • Kim, Yong-Gun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.3
    • /
    • pp.285-292
    • /
    • 2011
  • The purpose of thise study was to measure the thickness of the sinus lateral wall using computed tomography (CT), and to find the most suitable vertical position for lateral window opening prior to sinus elevation. Thirty patients requiring sinus elevation had CT images taken with Philips Brilliance iCT. The thickness of the sinus lateral wall was measured according to its vertical position against the sinus inferior border, and its mean was calculated through three repeated measurements. When measured 2 mm above the sinus inferior border (SIB+2), the thickness of the sinus lateral wall was observed to be more than 2 mm. When measured 3 mm above the sinus inferior border (SIB +3), the sinus lateral wall was less than 2 mm in thickness. It is recommended that the lateral wall window be made 3 mm above the sinus inferior border when performing sinus elevation using the lateral approach.

Correlation of Temporary Lateral Recumbency and Lung Opacity on Ventrodorsal Radiograph (일시적인 횡와 자세와 흉와위 영상에서 폐 불투과도의 상관관계)

  • Lee, Hyunjik;Jeong, Jiyoon;Choi, Wooshin;Lee, Donghoon;Lee, Youngjae;Chang, Jinhwa;Chang, Dongwoo
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.313-318
    • /
    • 2015
  • The lung opacity on radiography is influenced by various factors. The physical density of the lung and the attenuation ensured on computed tomography (CT) scans is determined by three components : lung tissue, blood, and air. Temporary right lateral recumbency may responsible for the increase of opacity on ventrodorsal projection view. Thus, our aim is to demonstrate that the effect of right lateral recumbency posture on right lung opacity using radiograph and CT scan. In this study, 62 dogs without clinical or radiologic signs of cardiopulmonary disease are selected. Thorax radiographs per 30 seconds for 2 minutes (30s, 60s, 90s, 120s) were performed for 62 dogs. After discussion of the radiographic findings of lung field by two radiologists and a student at Chungbuk national university veterinary medical center a consensus opinion was recorded. Computed tomography per a minute (1 min, 2 min) for 2 minutes were performed for 2 dogs. Mean x-ray attenuation of lung was measured quantitatively using software at two levels (aortic arch and basal level). Among 62 dogs with radiograph comparison, 9.3% of dogs showed influence by postural effect. However, all 2 dogs with computed tomography comparison, showed influence by postural effect. In conclusion, position dependent changes of lung density in CT exam are not consistent with thoracic radiograph.

Comparison of limited- and large-volume cone-beam computed tomography using a small voxel size for detecting isthmuses in mandibular molars

  • de Souza Tolentino, Elen;Andres Amoroso-Silva, Pablo;Alcalde, Murilo Priori;Yamashita, Fernanda Chiguti;Iwaki, Lilian Cristina Vessoni;Rubira-Bullen, Izabel Regina Fischer;Duarte, Marco Antonio Hungaro
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.27-34
    • /
    • 2021
  • Purpose: This study was performed to compare the ability of limited- and large-volume cone-beam computed tomography (CBCT) to display isthmuses in the apical root canals of mandibular molars. Materials and Methods: Forty human mandibular first molars with isthmuses in the apical 3 mm of mesial roots were scanned by micro-computed tomography (micro-CT), and their thickness, area, and length were recorded. The samples were examined using 2 CBCT systems, using the smallest voxels and field of view available for each device. The Mann-Whitney, Friedman, and Dunn multiple comparison tests were performed (α=0.05). Results: The 3D Accuitomo 170 and i-Cat devices detected 77.5% and 75.0% of isthmuses, respectively (P>0.05). For length measurements, there were significant differences between micro-CT and both 3D Accuitomo 170 and i-Cat(P<0.05). Conclusion: Both CBCT systems performed similarly and did not detect isthmuses in the apical third in some cases. CBCT still does not equal the performance of micro-CT in isthmus detection, but it is nonetheless a valuable tool in endodontic practice.

Accuracy verification of dental cone-beam computed tomography of mandibular incisor root canals and assessment of its morphology and aging-related changes

  • Katsuyuki Aoki;Masamitsu Serikawa;Takuya Harada;Akinobu Usami
    • Anatomy and Cell Biology
    • /
    • v.56 no.2
    • /
    • pp.185-190
    • /
    • 2023
  • The root canal morphology undergoes aging-related changes, and relevant quantitative analyses have not yet been reported. We compared the cone beam computed tomography (CBCT) and micro-computed tomography (microCT) scans of extracted mandibular incisors to check the accuracy of morphological measurements. Thereafter, the root canal morphology and aging-related changes in the mandibular incisors of Japanese individuals were assessed using CBCT. Six extracted teeth were fixed in a phantom head and imaged using CBCT and micro-CT. The correlation between the findings of the two imaging modalities was examined. Further, CBCT reconstructed images of the mandibular incisors of 81 individuals were observed. Age-related changes of the root canals were compared between participants aged <30 years and those aged ≥30 years. The CBCT and micro-CT findings regarding the root canals of the extracted teeth coincided in 94.4% of the cases. Mandibular incisors exhibiting two root canals in either cross-section accounted for 9.9% of central incisors and 12.4% of lateral incisors. Mandibular central incisors with two root canals were observed in two (6.3%) individuals aged <30 years and six (12.2%) aged ≥30 years. Mandibular lateral incisors with two root canals were observed in one (3.1%) individual aged <30 years and nine (18.4%) aged ≥30 years. CBCT allows accurate evaluation of complex root canal morphologies and is useful for endodontic preoperative assessment. Mandibular incisors have more frequent occurrence of two root canals with aging.

Computed Tomographic Findings of Navicular Syndrome in a Horse

  • Lee, Seyoung;Lee, Eun-bee;Park, Kyung-won;Jeong, Hyohoon;Kang, Tae-young;Seo, Jong-pil
    • Journal of Veterinary Clinics
    • /
    • v.38 no.2
    • /
    • pp.94-97
    • /
    • 2021
  • An 18-year-old warmblood gelding was presented to Jeju National University Equine Hospital with chronic bilateral forelimb lameness. Navicular syndrome was suspected based on clinical findings, the hoof test, palmar digital nerve block, and radiographic results. Computed tomography (CT) was performed under general anesthesia. Bone cysts, enlarged vascular channels, sclerosis, and enthesophytes were identified in the navicular bone on CT images. Mineralization in the deep digital flexor tendon was also observed. CT can be a useful diagnostic tool for identifying lesions of the navicular bone and adjacent structures in horses. The horse was treated with an intra-bursal injection of triamcinolone and gentamicin. Lameness started to improve two days later and the horse was sound after two months of the injection. CT enabled us not only to diagnosis of navicular syndrome but also to determine the degree and extent of the lesions.