• Title/Summary/Keyword: CT선량

Search Result 636, Processing Time 0.019 seconds

Comparison of Stereotactic Radiosurgery and Whole Brain Radiotherapy in Patients with Four or More Brain Metastases (4개 이상의 다발성 전이성 뇌종양의 정위적 방사선수술과 전뇌 방사선조사의 비교)

  • Kim, Cheol-Jin;Baek, Mi-Young;Park, Sung-Kwang;Ahn, Ki-Jung;Cho, Heung-Lae
    • Radiation Oncology Journal
    • /
    • v.27 no.3
    • /
    • pp.163-168
    • /
    • 2009
  • Purpose: This study was a retrospective evaluation of the efficacy of stereotactic radiosurgery (SRS) in patients with >4 metastases to the brain. Materials and Methods: Between January 2004 and December 2006, 68 patients with $\geq$4 multiple brain metastases were included and reviewed retrospectively. Twenty-nine patients received SRS and 39 patients received whole brain radiotherapy (WBRT). Patients with small cell lung cancers and melanomas were excluded. The primary lesions were non-small cell lung cancer (69.0%) and breast cancer (13.8%) in the SRS group and non-small cell lung cancer (64.1%), breast cancer (15.4%), colorectal cancer (12.8%), esophageal cancer (5.1%) in the WBRT group. SRS involved gamma-knife radiosurgery and delivered 10~20 Gy (median, 16 Gy) in a single fraction with a 50% marginal dose. WBRT was delivered daily in 3 Gy fractions, for a total of 30 Gy. After completion of treatment, a follow-up brain MRI or a contrast-enhanced brain CT was reviewed. The overall survival and intracranial progression-free survival were compared in each group. Results: The median follow-up period was 5 months (range, 2~19 months) in the SRS group and 6 months (range, 4~23 months) in the WBRT group. The mean number of metastatic lesions in the SRS and WBRT groups was 6 and 5, respectively. The intracranial progression-free survival and overall survival in the SRS group was 5.1 and 5.6 months, respectively, in comparison to 6.1 and 7.2 months, respectively, in the WBRT group. Conclusion: SRS was less effective than WBRT in the treatment of patients with >4 metastases to the brain.

Clinical Report of 46 Intracranial Tumors with LINAC Based Stereotactic Radiosurgery (선형가속기를 이용한 뇌종양 46예의 뇌정위다방향방사선치료 성적)

  • Yoon Sei C;Suh Tge S;Kim Sung W;Kang Ki M;Kim Yun S;Choi Byung O;Jang Hong S;Choi Kyo H;Kim Moon C;Shinn Kyung S
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.241-247
    • /
    • 1993
  • Between July 1988 and December 1992, we treated 45 patients who had deep seated inoperable or residual and/or recurrent intracranial tumors using LINAC based stereotactic radiosurgery at the Department of Therapeutic Radiology, Kangnam St. Mary's Hospital, Catholic University Medical College. Treated intracranial tumors included pituitary tumors (n=15), acoustic neurinomas (n=8), meningiomas (n=7), gliomas (n=6), craniopharyngiomas (n=4), pinealomas (n=3), hemangioblastomas (n=2), and solitary metastatic tumor from lung cancer (n=1). The dimension of treatment field varied from 0.23 to 42.88 $cm^3\;(mean;\;7.26\;cm^3)$. The maximum tumor doses ranging from 5 to 35.5 Gy (mean; 29.9 Gy) were given, and depended on patients' age, target volume, location of lesion and previous history of irradiation. There were 22 male and 23 female patients. The age was varied from 5 to 74 years of age (a median age; 43 years). The mean duration of follow-up was 35 months (2~55 months). To date, 18 $(39.1\%)$ of 46 intracranial tumors treated with SRS showed absent or decrease of the tumor by serial follow-up CT and/or MRI and 16 $(34.8\%)$ were stationary, e.g. growth arrest. From the view point of the clinical aspects, 34 $(73.9\%)$ of 46 tumors were considered improved status, that is, alive with no evidence of active tumor and 8 $(17.4\%)$ of them were stable, alive with disease but no deterioration as compared with before SRS. Although there showed slight increase of the tumor in size according to follow-up imagings of 4 cases (pituitary tumor 1, acoustic neurinomas 2, pinealoma 1), they still represented clinically stable status. Clinically, two $(4.4\%)$ Patients who were anaplastic astrocytoma (n=1) and metastatic brain tumor (n=1) were worsened following SRS treatment. So far, no serious complications were found after treatment. The minor degree headache which could be relieved by steroid or analgesics and transient focal hair loss were observed in a few cases. There should be meticulous long term follow-up inall cases.

  • PDF

Results of Three-Dimensional Conformal Radiation Therapy for the Treatment of a Solitary Sternal Relapse of Breast Cancer (흉골에 단독 전이된 유방암의 삼차원 입체조형 방사선 치료 성적)

  • Kim, Hae-Young;Huh, Seung-Jae;Park, Won;Choi, Do-Ho;Kang, Min-Kyu;Yang, Jung-Hyun;Nam, Seok-Jin;Im, Young-Hyuck
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.91-95
    • /
    • 2008
  • Purpose: To evaluate the response and survival rate after three-dimensional conformal radiation therapy(3D-CRT) of patients with a solitary sternal relapse of breast cancer. Materials and Methods: Seventeen patients between May 1996 and June 2005 were evaluated with the salvage 3D-CRT treatment of a solitary sternal relapse of breast cancer. The treatment fields included the gross tumor volume with 2 cm margins. The total radiation dose was $35.0{\sim}61.5$ Gy(biologic effective dose of $43.7{\sim}76.9Gy_{10}$ using an $\alpha/\beta$ ratio of 10 Gy), with a daily dose of $1.8{\sim}3.0$ Gy. The tumor response was evaluated by the change in maximum tumor size via follow up CT scans $1{\sim}3$ months after the completion of treatment. Results: An objective tumor response was achieved in all patients, with a complete response in 5 patients and a partial response in 12 patients. The 5-year overall survival rate was 51.9%(median survival time: 27 months), and the most important factor affecting overall survival was the disease-free interval(interval from primary surgery of breast cancer to the development of sternal metastasis): The 5-year overall survival rate was 61.8% for patients with a disease-free interval ${\geq}12$ months and 0.0% for patients with disease-free interval <12 months(p=0.03). Conclusion: The response to 3D-CRT was good in patients with solitary sternal relapse of breast cancer. Particularly, patients with long disease-free interval from primary surgery survived significantly longer than patients with short disease-free interval from primary surgery.

A Study of Various Filter Setups with FBP Reconstruction for Digital Breast Tomosynthesis (디지털 유방단층영상합성법의 FBP 알고리즘 적용을 위한 다양한 필터 조합에 대한 연구)

  • Lee, Haeng-Hwa;Kim, Ye-Seul;Lee, Youngjin;Choi, Sunghoon;Lee, Seungwan;Park, Hye-Suk;Kim, Hee-Joung;Choi, Jae-Gu;Choi, Young-Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.271-280
    • /
    • 2014
  • Recently, digital breast tomosynthesis (DBT) has been investigated to overcome the limitation of conventional mammography for overlapping anatomical structures and high patient dose with cone-beam computed tomography (CBCT). However incomplete sampling due to limited angle leads to interference on the neighboring slices. Many studies have investigated to reduce artifacts such as interference. Moreover, appropriate filters for tomosynthesis have been researched to solve artifacts resulted from incomplete sampling. The primary purpose of this study is finding appropriate filter scheme with FBP reconstruction for DBT system to reduce artifacts. In this study, we investigated characteristics of various filter schemes with simulation and prototype digital breast tomosynthesis under same acquisition parameters and conditions. We evaluated artifacts and noise with profiles and COV (coefficinet of variation) to study characteristic of filter. As a result, the noise with parameter 0.25 of Spectral filter reduced by 10% in comparison to that with only Ramp-lak filter. Because unbalance of information reduced with decreasing B of Slice thickness filter, artifacts caused by incomplete sampling reduced. In conclusion, we confirmed basic characteristics of filter operations and improvement of image quality by appropriate filter scheme. The results of this study can be utilized as base in research and development of DBT system by providing information that is about noise and artifacts depend on various filter schemes.

Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System (프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구)

  • Son, Junyoung;Choi, Sunghoon;Lee, Donghoon;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.111-118
    • /
    • 2019
  • Chest digital tomosynthesis has become a practical imaging modality because it can solve the problem of anatomy overlapping in conventional chest radiography. However, because of both limited scan angle and finite-size detector, a portion of chest cannot be represented in some or all of the projection. These bring a discontinuity in intensity across the field of view boundaries in the reconstructed slices, which we refer to as the truncation artifacts. The purpose of this study was to reduce truncation artifacts using a weighted normalization approach and to investigate the performance of this approach for our prototype chest digital tomosynthesis system. The system source-to-image distance was 1100 mm, and the center of rotation of X-ray source was located on 100 mm above the detector surface. After obtaining 41 projection views with ${\pm}20^{\circ}$ degrees, tomosynthesis slices were reconstructed with the filtered back projection algorithm. For quantitative evaluation, peak signal to noise ratio and structure similarity index values were evaluated after reconstructing reference image using simulation, and mean value of specific direction values was evaluated using real data. Simulation results showed that the peak signal to noise ratio and structure similarity index was improved respectively. In the case of the experimental results showed that the effect of artifact in the mean value of specific direction of the reconstructed image was reduced. In conclusion, the weighted normalization method improves the quality of image by reducing truncation artifacts. These results suggested that weighted normalization method could improve the image quality of chest digital tomosynthesis.

Clinical Usefulness of Implanted Fiducial Markers for Hypofractionated Radiotherapy of Prostate Cancer (전립선암의 소분할 방사선치료 시에 위치표지자 삽입의 유용성)

  • Choi, Young-Min;Ahn, Sung-Hwan;Lee, Hyung-Sik;Hur, Won-Joo;Yoon, Jin-Han;Kim, Tae-Hyo;Kim, Soo-Dong;Yun, Seong-Guk
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.91-98
    • /
    • 2011
  • Purpose: To assess the usefulness of implanted fiducial markers in the setup of hypofractionated radiotherapy for prostate cancer patients by comparing a fiducial marker matched setup with a pelvic bone match. Materials and Methods: Four prostate cancer patients treated with definitive hypofractionated radiotherapy between September 2009 and August 2010 were enrolled in this study. Three gold fiducial markers were implanted into the prostate and through the rectum under ultrasound guidance around a week before radiotherapy. Glycerin enemas were given prior to each radiotherapy planning CT and every radiotherapy session. Hypofractionated radiotherapy was planned for a total dose of 59.5 Gy in daily 3.5 Gy with using the Novalis system. Orthogonal kV X-rays were taken before radiotherapy. Treatment positions were adjusted according to the results from the fusion of the fiducial markers on digitally reconstructed radiographs of a radiotherapy plan with those on orthogonal kV X-rays. When the difference in the coordinates from the fiducial marker fusion was less than 1 mm, the patient position was approved for radiotherapy. A virtual bone matching was carried out at the fiducial marker matched position, and then a setup difference between the fiducial marker matching and bone matching was evaluated. Results: Three patients received a planned 17-fractionated radiotherapy and the rest underwent 16 fractionations. The setup error of the fiducial marker matching was $0.94{\pm}0.62$ mm (range, 0.09 to 3.01 mm; median, 0.81 mm), and the means of the lateral, craniocaudal, and anteroposterior errors were $0.39{\pm}0.34$ mm, $0.46{\pm}0.34$ mm, and $0.57{\pm}0.59$ mm, respectively. The setup error of the pelvic bony matching was $3.15{\pm}2.03$ mm (range, 0.25 to 8.23 mm; median, 2.95 mm), and the error of craniocaudal direction ($2.29{\pm}1.95$ mm) was significantly larger than those of anteroposterior ($1.73{\pm}1.31$ mm) and lateral directions ($0.45{\pm}0.37$ mm), respectively (p<0.05). Incidences of over 3 mm and 5 mm in setup difference among the fractionations were 1.5% and 0% in the fiducial marker matching, respectively, and 49.3% and 17.9% in the pelvic bone matching, respectively. Conclusion: The more precise setup of hypofractionated radiotherapy for prostate cancer patients is feasible with the implanted fiducial marker matching compared with the pelvic bony matching. Therefore, a less marginal expansion of planning target volume produces less radiation exposure to adjacent normal tissues, which could ultimately make hypofractionated radiotherapy safer.