• Title/Summary/Keyword: CT선량

Search Result 636, Processing Time 0.031 seconds

On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT) (콘빔CT (CBCT)를 이용한 온라인 영상유도방사선치료 (On-line Image Guided Radiation Therapy))

  • Bak, Jin-O;Jeong, Kyoung-Keun;Keum, Ki-Chang;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.294-299
    • /
    • 2006
  • $\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.

Combined Treatment of Residual, Recurrent and Unresectable Gastric Cancer (수술후 잔존 위암, 재발성 위암 및 절제 불가능한 위암의 병용 요법)

  • Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.85-93
    • /
    • 1990
  • A series of 25 patients with residual, recurrent, and unresectable gastric cancer received various combination of surgery, radiotherapy (RT), chemotherapy (CT), and hyperthermia (HT). They were placed into 7 categories; 1) CT and HT-14 patients; 2) RT and HT-15 patients; 3) surgery, RT and HT-2 patients; 4) surgery, RT, HT and CT-1 patient; 5) RT, HT and CT -1 patient; 6) RT and CT-1 patient; 7) RT alone-1 patient. Three patients had curative resection. 21 patients received irradiation with tightly contoured portals to spare as much small bowel, kidney and marrow as possible. Hyperthermia was applied regionally once or twice a week for 23 patients using 8 MHz radiofrequency capacitive heating device (Thermotron RF-8). HT was given approximately 30 min after RT 7 patients were treated with CT: 4 patients received HT and concomitant Mitomycin-C; 3 patients received HT and sequential 5-FU+Adriamycin+Mitomycin-C. There was not any treatment related deaths. There was also no evidence of treatment related problems with liver, kidney, stomach, or spinal cord except only one case of transient diabetic ketoacidosis. The tumor response was evaluable in 22 patients. None achieved complete remission.11 ($50\%$) achieved partial remission. The response rate was correlated with total radiation dose and achieved maximum temperature. 9 of 14 ($64\%$) received more than 4000 cGy showed partial remission; especially, all 3 patients received more than 5500 cGy achieved partial response.8 of the 12 patients ($67\%$) who achieved maximal temperature more than $41^{\circ}C$ showed partial response in comparing with $25\%$ (2 of 8 patients, below $41^{\circ}C$). The numbers of HT, however, was not correlated with the response. 3 of the 25 patients ($12\%$) remain alive. The one who was surgically unresectable and underwent irradiation alone is in progression of the disease with distant metastases. The remaining two patients with curative resection are alive with free of disease, 24 and 35 months, respectively. The median survival by response are 11.5 months in responders and 4.6 months in non-responders.

  • PDF

The Effect of Partially Used High Energy Photon on Intensity-modulated Radiation Therapy Plan for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 부분적 고에너지 광자선 사용에 따른 치료계획 평가)

  • Chang, Nam Joon;Seok, Jin Yong;Won, Hui Su;Hong, Joo Wan;Choi, Ji Hun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: A selection of proper energy in treatment planning is very important because of having different dose distribution in body as photon energy. In generally, the low energy photon has been used in intensity-modulated radiation therapy (IMRT) for head and neck (H&N) cancer. The aim of this study was to evaluate the effect of partially used high energy photon at posterior oblique fields on IMRT plan for H&N cancer. Materials and Methods: The study was carried out on 10 patients (nasopharyngeal cancer 5, tonsilar cancer 5) treated with IMRT in Seoul National University Bundang Hospital. CT images were acquired 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). Two plans were generated under same planing objectives, dose volume constraints, and eight fields setting: (1) The low energy plan (LEP) created using 6 MV beam alone, (2) the partially used high energy plan (PHEP) created partially using 15 MV beam at two posterior oblique fields with deeper penetration depths, while 6 MV beam was used at the rest of fields. The plans for LEP and PHEP were compared in terms of coverage, conformity index (CI) and homogeneity index (HI) for planning target volume (PTV). For organs at risk (OARs), $D_{mean}$ and $D_{50%}$ were analyzed on both parotid glands and $D_{max}$, $D_{1%}$ for spinal cord were analyzed. Integral dose (ID) and total monitor unit (MU) were compared as addition parameters. For the comparing dose to normal tissue of posterior neck, the posterior-normal tissue volume (P-NTV) was set on the patients respectively. The $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ for P-NTV were evaluated by using dose volume histogram (DVH). Results: The dose distributions were similar with regard to coverage, CI and HI for PTV between the LEP and PHEP. No evident difference was observed in the spinal cord. However, the $D_{mean}$, $D_{50%}$ for both parotid gland were slightly reduced by 0.6%, 0.7% in PHEP. The ID was reduced by 1.1% in PHEP, and total MU for PHEP was 1.8% lower than that for LEP. In the P-NTV, the $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ of the PHEP were 1.6%, 1.8% and 2.9% lower than those of LEP. Conclusion: Dose to some OARs and a normal tissue, total monitor unit were reduced in IMRT plan with partially used high energy photon. Although these reduction are unclear how have a clinical benefit to patient, application of the partially used high energy photon could improve the overall plan quality of IMRT for head and neck cancer.

  • PDF

The efficacy of continuous positive airway pressure (CPAP) for patient with left breast cancer (좌측 유방암 방사선치료에서 CPAP(Continuous Positive Airway Pressure)의 유용성 평가)

  • Jung, Il Hun;Ha, Jin Sook;Chang, Won Suk;Jeon, Mi Jin;Kim, Sei Joon;Jung, Jin Wook;Park, Byul Nim;Shin, Dong Bong;Lee, Ik Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose: This study examined changes in the position of the heat and lungs depending on the patient's breathing method during left breast cancer radiotherapy and used treatment plans to compare the resulting radiation dose. Materials and methods: The participants consisted of 10 patients with left breast cancer. A CT simulator(SIMENS SOMATOM AS, Germany) was used to obtain images when using three different breathing methods: free breathing(FB), deep inspiration breath hold(DIBH with Abches, DIBH), inspiration breath hold(IBH with CPAP, CPAP). A Ray Station(5.0.2.35, Sweden) was used for treatment planning, the treatment method was volumetric modulated arc therapy (VMAT) with one partial arc of the same angle, and the prescribed dose to the planning target volume (PTV) was a total dose of 50Gy(2Gy/day). In treatment plan analysis, the 95% dose (D95) to the PTV, the conformity index(CI), and the homogeneity index (HI) were compared. The lungs, heart, and left anterior descending artery (LAD) were selected as the organs at risk(OARs). Results: The mean volume of the ipsilateral lung for FB, DIBH, and CPAP was 1245.58±301.31㎤, 1790.09±362.43 ㎤, 1775.44±476.71 ㎤. The mean D95 for the PTV was 46.67±1.89Gy, 46.85±1.72Gy, 46.97±23.4Gy, and the mean CI and HI were 0.95±0.02, 0.96±0.02, 0.95±0.02 and 0.91±0.01, 0.90±0.01, 0.92±0.02. The V20 of Whole Lung was 10.74±4.50%, 8.29±3.14%, 9.12±3.29% and The V20 of the ipsilateral lung was 20.45±8.65%, 17.18±7.04%, 18.85±7.85%, the Dmean of the heart was 7.82±1.27Gy, 6.10±1.27Gy, 5.67±1.56Gy, and the Dmax of the LAD was 20.41±7.56Gy, 14.88±3.57Gy, 14.96±2.81Gy. The distance from the thoracic wall to the LAD was measured to be 11.33±4.70mm, 22.40±6.01mm, 20.14±6.23mm. Conclusion: During left breast cancer radiotherapy, the lung volume was 46.24% larger for DIBH than for FB, and 43.11% larger for CPAP than FB. The larger lung volume increases the distance between the thoracic wall and the heart. In this way, the LAD, which is one of the nearby OARs, can be more effectively protected while still satisfying the treatment plan. The lung volume was largest for DIBH, and the distance between the LAD and thoracic wall was also the greatest. However, when performing treatment with DIBH, the intra-fraction error cannot be ignored. Moreover, communication between the patient and the radiotherapist is also an important factor in DIBH treatment. When communication is problematic, or if the patient has difficulty holding their breath, we believe that CPAP could be used as an alternative to DIBH. In order to verify the clinical efficacy of CPAP, it will be necessary to perform long-term follow-up of a greater number of patients.

Evaluation of the Treatment Response after Hypofractionated Radiotherapy in Patients with Advanced Head and Neck Cancers (진행성 두경부 상피세포암 환자에서 소분할 방사선조사 후의 치료반응 평가)

  • Kim, Won-Taek;Ki, Yong-Kan;Nam, Ji-Ho;Kim, Dong-Hyun;Cho, Kyu-Sup;Lee, Jin-Choon;Lee, Byung-Joo;Kim, Dong-Won
    • Radiation Oncology Journal
    • /
    • v.27 no.2
    • /
    • pp.55-63
    • /
    • 2009
  • Purpose: This study was performed to objectively evaluate the rate of tumor response to hypofractionated radiotherapy for advanced squamous cell carcinomas of the head and neck. Materials and Methods: Thirty-one patients with advanced squamous cell carcinoma of the head and neck, who were treated by hypofractionated radiotherapy with 3 Gy per fraction for palliative purpose between 1998 and 2008, were reviewed retrospectively. Every tumor-volume was measured and evaluated from CT (computed tomography) images obtained before and 2~3 months after radiotherapy. The radiation toxicity was assessed during and after radiotherapy. A statistical analysis was performed to investigate overall survival, progressionfree survival, and the prognostic factors for survival and response. Results: The median age of the study patients was 70 years. In addition, 85% of the patients were in stage 4 cancer and 66.7% had an ECOG performance status of 1~2. The mean tumor-volume was 128.4 cc. Radiotherapy was administered with a total dose of 24~45 Gy (median: 36 Gy) over 10~25 days. Twenty-nine patients were treated with 30 Gy or more. The observed complete response rate was 12.9% and the partial response rate was 61.3%. Median survival time was 8.9 months and the 1-year progression-free survival rate was 12.9%. The treatment response rate was confirmed as a prognostic factor in the rate of survival. The primary site, stage, tumor-volume, radiotherapy field and overall radiation-dose showed a significant relationship with survival and treatment response. No grade 4 toxicity was observed during and after radiotherapy. Conclusion: There was an objective tumor-regression in about 74% of patients treated by hypofractionated radiotherapy. Further evaluation is needed to select the appropriate fraction-size and patient who may require the additional radiotherapy.

Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119 (세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용)

  • Ahn, Woo-Sang;Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The purpose of this study is to evaluate the accuracy of IMRT in our clinic from based on TG119 procedure and establish action level. Five IMRT test cases were described in TG119: multi-target, head&neck, prostate, and two C-shapes (easy&hard). There were used and delivered to water-equivalent solid phantom for IMRT. Absolute dose for points in target and OAR was measured by using an ion chamber (CC13, IBA). EBT2 film was utilized to compare the measured two-dimensional dose distribution with the calculated one by treatment planning system. All collected data were analyzed using the TG119 specifications to determine the confidence limit. The mean of relative error (%) between measured and calculated value was $1.2{\pm}1.1%$ and $1.2{\pm}0.7%$ for target and OAR, respectively. The resulting confidence limits were 3.4% and 2.6%. In EBT2 film dosimetry, the average percentage of points passing the gamma criteria (3%/3 mm) was $97.7{\pm}0.8%$. Confidence limit values determined by EBT2 film analysis was 3.9%. This study has focused on IMRT commissioning and quality assurance based on TG119 guideline. It is concluded that action level were ${\pm}4%$ and ${\pm}3%$ for target and OAR and 97% for film measurement, respectively. It is expected that TG119-based procedure can be used as reference to evaluate the accuracy of IMRT for each institution.

Effects of Fractionated Stereotactic Radiotherapy for Primary Hepatocellular Carcinoma (원발성 간암의 분할 정위방사선치료 효과)

  • Choi Byeong Ock;Kang Ki Mun;Jang Hong Seok;Lee Snag-wook;Kang Young Nam;Chai Gyu Young;Choi Ihl Bhong
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.92-97
    • /
    • 2005
  • Purpose : Reports on the outcome of curative radiotherapy for the primary hepatocellular carcinoma (HCC) are rarely encountered in the literature. in this study, we report our experience of a clinical trial where fractionated stereotactic radiotherapy (SRT) was used in treating a primary HCC. Materials and Methods : A retrospective analysis was peformed on 20 patients who had been histologically diagnosed as HCC and treated by fractionated SRT. The long diameter of tumor measured by CT was $2\~6.5$ cm (average: 3.8 cm). A single dose of radiation used in fractionated SRT was S or 10 Gy: each dose was prescribed based on the planning target volume and normalized to $85\~99\%$ isocenter dose. Patients were treated $3\~5$ times per week for 2 weeks, with each receiving a total dose of 50 Gy (the median dose: 50 Gy). The follow up period was $\~55$ months (the median follow up period: 23 months). Results : The response rate was $50\%$ (12 patients), with 4 patients showing complete response ($20%$), 8 patients showing partial response ($40\%$), and 8 patients showing stable disease ($40\%$). The 1-year and 2-year survival rates were $70.0\%$ and $43.1\%$, respectively, and the median survival time was 20 months. The 1-year and 2-year disease free survival rates were $65\%$ and $32.5\%$, respectively, and the median disease-free survival rate was 19 months. Some acute complications of the treatment were noted as follows: dyspepsia in 12 patients ($60\%$), nausea/emesis in 8 patients ($40\%$), and transient liver function impairment in 6 patients ($30\%$). However, there was no treatment related death. Conclusion : The study indicates that fractionated SRT is a relatively safe and effective method for treating primary HCC. Thus, fractionated SRT may be suggested as a local treatment for HCC of small lesion and containing a single lesion, when the patients are inoperable or operation is refused by the patients. We thought that fractionated SRT is a challenging treatment modality for the HCC.

Comparison and evaluation of treatment plans using Abdominal compression and Continuous Positive Air Pressure for lung cancer SABR (폐암의 SABR(Stereotactic Ablative Radiotherapy)시 복부압박(Abdominal compression)과 CPAP(Continuous Positive Air Pressure)를 이용한 치료계획의 비교 및 평가)

  • Kim, Dae Ho;Son, Sang Jun;Mun, Jun Ki;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.35-46
    • /
    • 2021
  • Purpose : By comparing and analyzing treatment plans using abdominal compression and The Continuous Positive Air Pressure(CPAP) during SABR of lung cancer, we try to contribute to the improvement of radiotherapy effect. Materials & Methods : In two of the lung SABR patients(A, B patient), we developed a SABR plan using abdominal compression device(the Body Pro-Lok, BPL) and CPAP and analyze the treatment plan through homogeneity, conformity and the parameters proposed in RTOG 0813. Furthermore, for each phase, the X, Y, and Z axis movements centered on PTV are analyzed in all 4D CTs and compared by obtaining the volume and average dose of PTV and OAR. Four cone beam computed tomography(CBCT) were used to measure the directions from the center of the PTV to the intrathoracic contacts in three directions out of 0°, 90°, 180° and 270°, and compare the differences from the average distance values in each direction. Result : Both treatment plans obtained using BPL and CPAP followed recommendations from RTOG, and there was no significant difference in homogeneity and conformity. The X-axis, Y-axis, and Z-axis movements centered on PTV in patient A were 0.49 cm, 0.37 cm, 1.66 cm with BPL and 0.16 cm, 0.12 cm, and 0.19 cm with CPAP, in patient B were 0.22 cm, 0.18 cm, 1.03 cm with BPL and 0.14 cm, 0.11 cm, and 0.4 cm with CPAP. In A patient, when using CPAP compared to BPL, ITV decreased by 46.27% and left lung volume increased by 41.94%, and average dose decreased by 52.81% in the heart. In B patient, volume increased by 106.89% in the left lung and 87.32% in the right lung, with an average dose decreased by 44.30% in the stomach. The maximum difference of A patient between the straight distance value and the mean distance value in each direction was 0.05 cm in the a-direction, 0.05 cm in the b-direction, and 0.41 cm in the c-direction. In B patient, there was a difference of 0.19 cm in the d-direction, 0.49 cm in the e-direction, and 0.06 cm in the f-direction. Conclusion : We confirm that increased lung volume with CPAP can reduce doses of OAR near the target more effectively than with BPL, and also contribute more effectively to restriction of tumor movement with respiration. It is considered that radiation therapy effects can be improved through the application of various sites of CPAP and the combination with CPAP and other treatment machines.

Stereotactic Radiosurgery for Recurrent Glioblastoma Multiforme using Yeungnam Localization Device - Technical note and Clinical trial - (뇌정위적 방사선 절제술에 필요한 위치선정용기구 제작과 치험 2예)

  • Shin, Sei-One;Kim, Sung-Kyu;Kim, Myung-Se;Kim, Oh-Lyong;Cho, Soo-Ho
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.101-105
    • /
    • 1992
  • Authors performed a stereotactic radiosurgery with multiple noncoplanar convergent photon beams of linear accelerator (NELAC-1018 18 MeV, NEC) using a specially designed Yeungnam localization device for two patients with recurrent glioblastoma multiforme. One patient had 2 cm sized and the other 4 cm sized mass on the CT images. After single session of treatment with 15 and 20 Gy, headache was improved in a few days after radiosurgery with no remarkable untoward reactions. Our experience with these two patients were encouraging and we found that our localization device, which is easily adjustable and inexpensive, could be a valuable tool for stereotactic radiosurgery particularly in the treatment of recurrent brain tumor.

  • PDF

A Study about Amendment of Safety Control of Computed Tomography (전산화단층촬영용장치의 안전관리 개정에 관한 연구)

  • Kim, Kyotae;Heo, Yeji;Oh, Kyungmin;Noh, Sicheul;Kang, Sangsik;Nam, Sanghee;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.383-387
    • /
    • 2013
  • Diagnostic imaging systems play a critical role in obtaining anatomical images, which increases the frequency of inspection all over the world. However the likelihood that patients are exposed to relatively high radiation dose increases, which may lead to an increase of patient dose due to unnecessary radiation exposure unless appropriate management is accompanied. Thus the revised edition of IEC 60601-2-44 which is constancy tests for CT equipment which is designated as special medical equipment and is subject to safety management was studied. The results suggested the 3rd has been revised rationally in order to overcome the limitations in the 2nd by adopting clear and enhanced references, which implies the replacement of IEC 60601-2-44 2nd edition with IEC 60601-2-44 3rd will prevent the patients from the harm from improper medical equipment.