• Title/Summary/Keyword: CT선량

Search Result 636, Processing Time 0.027 seconds

Evaluation of Ovary Dose for woman of Childbearing age Woman with Breast cancer in tomotherapy (가임기 여성의 유방암 토모치료 시 난소선량 평가비교)

  • Lee, Soo Hyeung;Park, Soo Yeun;Choi, Ji Min;Park, Ju Young;Kim, Jong Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.337-343
    • /
    • 2014
  • Purpose : The aim of this study is to evaluate unwanted scattered dose to ovary by scattering and leakage generated from treatment fields of Tomotherapy for childbearing woman with breast cancer. Materials and Methods : The radiation treatments plans for left breast cancer were established using Tomotherapy planning system (Tomotherapy, Inc, USA). They were generated by using helical and direct Tomotherapy methods for comparison. The CT images for the planning were scanned with 2.5 mm slice thickness using anthropomorphic phantom (Alderson-Rando phantom, The Phantom Laboratory, USA). The measurement points for the ovary dose were determined at the points laterally 30 cm apart from mid-point of treatment field of the pelvis. The measurements were repeated five times and averaged using glass dosimeters (1.5 mm diameter and 12 mm of length) equipped with low-energy correction filter. The measures dose values were also converted to Organ Equivalent Dose (OED) by the linear exponential dose-response model. Results : Scattered doses of ovary which were measured based on two methods of Tomo helical and Tomo direct showed average of $64.94{\pm}0.84mGy$ and $37.64{\pm}1.20mGy$ in left ovary part and average of $64.38{\pm}1.85mGy$ and $32.96{\pm}1.11mGy$ in right ovary part. This showed when executing Tomotherapy, measured scattered dose of Tomo Helical method which has relatively greater monitor units (MUs) and longer irradiation time are approximately 1.8 times higher than Tomo direct method. Conclusion : Scattered dose of left and right ovary of childbearing women is lower than ICRP recommended does which is not seriously worried level against the infertility and secondary cancer occurrence. However, as breast cancer occurrence ages become younger in the future and radiation therapy using high-precision image guidance equipment like Tomotherapy is developed, clinical follow-up studies about the ovary dose of childbearing women patients would be more required.

Implementation of Man-made Tongue Immobilization Devices in Treating Head and Neck Cancer Patients (두 경부 암 환자의 방사선치료 시 자체 제작한 고정 기구 유용성의 고찰)

  • Baek, Jong-Geal;Kim, Joo-Ho;Lee, Sang-Kyu;Lee, Won-Joo;Yoon, Jong-Won;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Purpose: For head and neck cancer patients treated with radiation therapy, proper immobilization of intra-oral structures is crucial in reproducing treatment positions and optimizing dose distribution. We produced a man-made tongue immobilization device for each patient subjected to this study. Reproducibility of treatment positions and dose distributions at air-and-tissue interface were compared using man-made tongue immobilization devices and conventional tongue-bites. Materials and Methods: Dental alginate and putty were used in producing man-made tongue immobilization devices. In order to evaluate reproducibility of treatment positions, all patients were CT-simulated, and linac-gram was repeated 5 times with each patient in the treatment position. An acrylic phantom was devised in order to evaluate safety of man-made tongue immobilization devices. Air, water, alginate and putty were placed in the phantom and dose distributions at air-and-tissue interface were calculated using Pinnacle (version 7.6c, Phillips, USA) and measured with EBT film. Two different field sizes (3$\times$3 cm and 5$\times$5 cm) were used for comparison. Results: Evaluation of linac grams showed reproducibility of a treatment position was 4 times more accurate with man-made tongue immobilization devices compared with conventional tongue bites. Patients felt more comfortable using customized tongue immobilization devices during radiation treatment. Air-and-tissue interface dose distributions calculated using Pinnacle were 7.78% and 0.56% for 3$\times$3 cm field and 5$\times$5 cm field respectively. Dose distributions measured with EBT (international specialty products, USA) film were 36.5% and 11.8% for 3$\times$3 cm field and 5$\times$5 cm field respectively. Values from EBT film were higher. Conclusion: Using man-made tongue immobilization devices made of dental alginate and putty in treatment of head and neck cancer patients showed higher reproducibility of treatment position compared with using conventional mouth pieces. Man-made immobilization devices can help optimizing air-and-tissue interface dose distributions and compensating limited accuracy of radiotherapy planning systems in calculating air-tissue interface dose distributions.

  • PDF

Radiation Safety Management Guidelines for PET-CT: Focus on Behavior and Environment (PET-CT의 방사선안전관리 가이드라인 개발: 행위와 환경을 중심으로)

  • Jung, Jin-Wook;Han, Eun-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.3
    • /
    • pp.140-147
    • /
    • 2011
  • Our purpose is to specify behavior and environmental factors aimed at reducing the exposed dosage caused by PET-CT and to develop radiation safety management guidelines adequate for domestic circumstances. We have used a multistep-multimethod as the methodological approach to design and to carry out the research both in quality and quantity, including an analysis on previous studies, professional consultations and a survey. The survey includes responses from 139 practitioners in charged of 109 PET-CTs installed throughout Korea(reported by the Korean Society of Nuclear Medicine, 2010). The research use 156 questions using Cronbach's ${\alpha}$ (alpha) coefficients which were: 0.818 for "the necessity of setting and installing the radiation protective environment"; 0.916 for "the necessity of radiation protection", "setting and installing the radiation protective environment"; and 0.885 for "radiation protection". The check list, derived from the radiation safety management guidelines focused on behavior and environment, was composed of 20 items for the radiation protective environment: including 5 items for the patient; 4 items for the guardian; 3 items for the radiologist; and 8 items applied to everyone involved; for a total of 26 items for the radiation protective behavior including: 12 items for the patient; 1 item for the guardian, 7 items for the radiologist; and 6 items applied to everyone involved. The specific check list is shown in(Table 5-6). Since our country has no safety management guidelines of its own to reduce the exposed dosage caused by PET-CTs, we believe the guidelines developed through this study means great deal to the field as it is not only appropriate for domestic circumstances, but also contains specific check lists for each target who may be exposed to radiation in regards to behavior and environment.

A Study of the CT MAR using Single-Source and Dual-Source Devices: Practical Comparison using Animal Phantom Fabrication (단일 선원 장치와 이중 선원 장치 비교를 이용한 전산화단층촬영 금속인공물 감소에 대한 연구: 동물팬텀 제작을 이용한 실측적인 비교)

  • Goo, EunHoe
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.1003-1011
    • /
    • 2020
  • This study aims to compare and evaluate the image differences between single and dual sources in applying a technique to reduce metal artifacts using dual energy CT. Discovery CT 256 (GE, USA) as a single source device and Somatom Definition Flash (Siemens Health Care, Forchheim, Germany) as a dual source device. The self-made phantom (pigs with medical titanium screws inserted) was quantitative and qualitatively evaluated under the same conditions by varying the dose under the same conditions using a dual energy CT. The evaluation method was compared by measuring SNR for metal artifacts (scattering, stripe) generated by metal inserts, divided around bones and around tissues. There was a difference in images in the method of reducing metal artifacts between single-source and dual-source devices. In a single source device, the linearized prosthesis by metal implantation showed a greater decrease than the image obtained from a double source device, and the surrounding tissue was well observed without interference from the artifact. In dual-source devices, scattering and stripe artifacts caused by metal inserts decreased more than on a single source device, and signals from adjacent tissues surrounding the metal implant were well observed without diminishing. If the examination is conducted separately between single source and dual source devices depending on whether the area to which the patient is intended to be viewed during the examination is adjacent to the metal insert or the total tissue surrounding the metal insert, it is believed that diagnostic helpful images can be obtained.

Adaptation of Deep Learning Image Reconstruction for Pediatric Head CT: A Focus on the Image Quality (소아용 두부 컴퓨터단층촬영에서 딥러닝 영상 재구성 적용: 영상 품질에 대한 고찰)

  • Nim Lee;Hyun-Hae Cho;So Mi Lee;Sun Kyoung You
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.240-252
    • /
    • 2023
  • Purpose To assess the effect of deep learning image reconstruction (DLIR) for head CT in pediatric patients. Materials and Methods We collected 126 pediatric head CT images, which were reconstructed using filtered back projection, iterative reconstruction using adaptive statistical iterative reconstruction (ASiR)-V, and all three levels of DLIR (TrueFidelity; GE Healthcare). Each image set group was divided into four subgroups according to the patients' ages. Clinical and dose-related data were reviewed. Quantitative parameters, including the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and qualitative parameters, including noise, gray matter-white matter (GM-WM) differentiation, sharpness, artifact, acceptability, and unfamiliar texture change were evaluated and compared. Results The SNR and CNR of each level in each age group increased among strength levels of DLIR. High-level DLIR showed a significantly improved SNR and CNR (p < 0.05). Sequential reduction of noise, improvement of GM-WM differentiation, and improvement of sharpness was noted among strength levels of DLIR. Those of high-level DLIR showed a similar value as that with ASiR-V. Artifact and acceptability did not show a significant difference among the adapted levels of DLIR. Conclusion Adaptation of high-level DLIR for the pediatric head CT can significantly reduce image noise. Modification is needed while processing artifacts.

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.

Evaluating the usefulness of BinkieRTTM (oral positioning stent) for Head and Neck Radiotherapy (두경부암 환자 방사선 치료 시 BinkieRTTM(구강용 고정장치)에 대한 유용성 평가)

  • GyeongJin Lee;SangJun Son;GyeongDal Lim;ChanYong Kim;JeHee Lee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.21-30
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of oral positioning stent, the BinkieRTTM in radiation treatment for head and neck cancer patients in terms of tongue positions reproducibility, tongue doses and material properties. Materials and Methods: 24 cases using BinkieRTTM during radiation treatments were enrolled. The tongue was contoured on planning CT and CBCT images taken every 3 days during treatment, and then the DSC and center of tongue shift values were analyzed to evaluate the reproducibility of the tongue. The tongue dose was compared in terms of dose distribution when using BinkieRTTM and different type of oral stents (mouthpiece, paraffin wax). Randomly selected respective 10 patients were measured tongue doses of initial treatment plan for nasal cavity and unilateral parotid cancer. Finally, In terms of material evaluation, HU and relative electron density were identified in RTPS. Results: As a result of DSC analysis, it was 0.8 ± 0.07, skewness -0.8, kurtosis 0.61, and 95% CI was 0.79~0.82. To analyze the deviation of the central tongue shift during the treatment period, a 95% confidence interval for shift in the LR, SI, and AP directions were indicated, and a one-sample t-test for 0, which is an ideal value in the deviation(n=144). As a result of the t-test, the mean and SD in the LR and SI directions were 0.01 ± 0.14 cm (p→.05), 0.03 ± 0.25 cm (p→.05), and -0.08 ± 0.25 cm (p ←.05) in the AP direction. In the case of unilateral parotid cancer patients, the Dmean to the tongue of patients using BinkieRTTM was 16.92% ± 3.58% compared to the prescribed dose, and 23.99% ± 10.86% of patients with Paraffin Wax, indicating that the tongue dose was relatively lower when using BinkieRTTM (p←.05). On the other hand, among nasal cavity cancer patients, the Dmean of tongue dose for patients who used BinkieRTTM was 4.4% ± 5.6%, and for those who used mouthpiece, 5.9% ± 6.8%, but it was not statistically significant (p→.05). The relative electron density of Paraffin Wax, BinkieRTTM and Putty is 0.94, 0.99, 1.26 and the mass density is 0.95, 0.99 and 1.32 (g/cc), Transmission Factor is 0.99, 0.98, 0.96 respectively. Conclusion: The result of the tongue DSC analysis over the treatment period was about 0.8 and Deviation of the center of tongue shifts were within 0.2 cm, the reproducibility was more likely excellent. In the case of unilateral head and neck cancer patients, it was found that the use of BinkieRTTM rather than Paraffin Wax or Putty can reduce the unnecessary dose irradiated to the tongue. This study might be useful to understand of BinkieRTTM's properties and advantages. And also it could be another considered option as oral stent to keep the reproducibility of tongue and reducing dose during head and neck radiation treatments.

Head & neck 환자의 방사선치료 시 tongue displacer 사용의 유용성 평가

  • 박용철;박영환;김경태;최지민
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.1-5
    • /
    • 2002
  • I. 목적 : 방사선 치료 시 최적화된 체내 선량분포를 얻는 것은 정상조직의 장애를 줄이고 종양선량을 높여 치료 효율을 극대화하는데 매우 중요하다. 본원에서는 병변 부위가 한쪽으로 치우친 head&neck 환자 치료 시 정상조직(tongue)을 보호하기 위해 tongue displacer를 만들어 사용한다. 이에 본 저자는 tongue displacer사용의 치료 유용성을 평가 하고자 한다. II. 대상 및 방법 : head & neck 치료 환자 중 병변 부위가 인체의 정중선(MSP)을 기준으로 한쪽으로 치우친 환자를 대상으로 하였다. 사용된 실험재료로는 C-T (high speed advantage, GE,US), RTP System (3D RTP system, prowess, US), 치과용 인상제 주입기(caulk system, quixx, japan), tongue displacer 등이 있다. 실험 방법은 모의 치료나 planning C-T를 시행하기 전에 치료 환자에게 사용할 개인용 tongue displacer를 치과용 인상제로 자체 제작하였다. 제작 후 모의 치료를 시행하고 3D plan을 하기 위해 planning C-T를 촬영하게 되는데 이때 tongue displacer사용 유. 무에 따라 각각 촬영을 하였다. 촬영된 두 가지의 CT영상을 prowess를 이용하여 3D plan을 하게 되는데 이때의 plan parameter나 beam direction등 plan에서의 모든 조건은 모두 동일시하고 선량 분포 및 DVH(dose volume histogram)값을 비교하였다. III. 결과 : tongue displace의 사용 유. 무에 따른 3D plan상의 DVH 비교 결과 tumor volume 주위의 다른 organ들은 모두 비슷한 양상의 DVH를 보였으나 tongue에 있어서 큰 변화를 보였다. tongue displacer를 사용 시, 미 사용시 보다 tongue의 위치를 변화시켜 치료 부위 외의 tongue에 받는 방사선 피폭 면적을 줄일 수 있었고 그 결과 DVH상의 $50\%$ volume이 $16\%$ 정도 줄어드는 것이 확인되었다. IV. 결론 : tongue에 방사선을 조사하면 방사선 부작용으로 mucositis, ulcer, hemorrhage등의 pain(동통)이 수반되므로 치료환자의 음식물 섭취불량으로 체증감소 등 전신 쇠약으로 이어질 수 있다. head & neck 환자 중에서 병소 위치가 한쪽으로 치우쳐서 있을 경우 인상제를 이용하여 tongue displacer를 만들어서 사용하면 tongue 의 위치를 변화시켜 방사선 조사 야에서 제외시켜준다. 그러므로 방사선 치료 시 tongue의 부작용을 최소화 할 수 있고 환자의 방사선 치료 만족도를 높일 수 있다고 사료된다.

  • PDF

Research For Reducing Patient Dose that Low Extremity CT Angiography Using Automatic Current Selection (하지동맥조영 전산화단층촬영에서 자동선량 조절장치를 이용한 환자선량 감소 연구)

  • An, Hyeong-Theck;Kim, Jae-Yeol;Yeo, Woon-Sik;Park, Yong-Sung;Lee, Gui-Won;Lee, Jong-Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.45-53
    • /
    • 2013
  • Purpose : Fixed way of mAs previously Low Extremity Computed Tomography Angiography(LECTA) examination were used. Automatic Current Selection(ACS) to use for the purpose of reducing the dose when Low Extremity Computed Tomography Angiography examining patients. Materials and methods : Were analyzed from July 2011 to July 2012 MDCT examination of Dose Length Product(DLP) LECTA 116 Case. It was defined as previous inspection methods(Old protocol). CT workstation is set to 100 mAs and 150 mAs protocol based on the patient's weight 70kg examined by LECTA. We defined as 'New protocol' that applies to ACS. The data collection period are 76 cases from October 2012 to January 2013 Results : 1. Average Total DLP of 'Old protocol' is 3602.943 $mGy^*cm$. 2. Average Total DLP of 'New protocol' is 1762.977 $mGy^*cm$. 3. Due to the 'New Protocol' use of Total DLP was reduced by approximately 51 %. Phase-specific dose reduction is as follows. Pre(33.62 %), Artery(64.63 %), Delay(49.0 %) 4. Using One way ANOVA Analysis of fluctuations obtained DLP is as follows. 'Old protocol', 'New protocol' a value of P < 0.001, P = 0.882 values were obtained. Conclusions : Dose reduction of 51 % is a useful study that proves. The results obtained using the ACS, the effects of a dose reduction of 51 % was obtained. Therefore, it has been proven to be a useful way. Statistics using SPSS version came out of the 'Old protocol' P-value P < 0.0001. This result means that the DLP a large difference values. On the other hand, The results of the 'New protocol' was P = 0.882. These results means to that small and regularly was fluctuations of the dose. The use of ACS, you can get a reduction of the dose and will able to get the effect of reducing the dose errors.

  • PDF

Study of radiation exposure on human body using of Computed Tomography (전산화단층촬영 검사 시 인체에 미치는 방사선피폭선량 분석연구)

  • Seon, Jong-Ryoul;Yoo, Se-Jong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.193-198
    • /
    • 2015
  • This study analyzed the total number of 19,636 patients and radiation technologists, 11,433 of male and 8,203 of female by examined body parts, age, types of detectors, the using contrast enhancement and working condition of the technologists, regular staffs or rotation-duty staffs, based on the K-DOS program distributed by FDA with the DLP value of diagnostic evaluation. The result shows that the effective radiation dose was 0.7mSv~41.7mSv for each region and male patients had more radiation exposure than females. And the amount of exposure was also affected by the types and the method of detectors. Furthermore, the regular staffs took the role of helping the patient to get reduced amount of radiation exposure than rotation duty-staffs. Computed tomography (CT) use has increased dramatically over the past several decades. In this reason, to support the patients and the workers' health in the field, the hospitals should apply specialized regular working radiation technologist system and manufacturing companies of those CTs should develop low medical radiation exposure devices.