• Title/Summary/Keyword: CT, MRI

Search Result 899, Processing Time 0.376 seconds

CT and MRI for Repaired Complex Adult Congenital Heart Diseases

  • Suvipaporn Siripornpitak;Hyun Woo Goo
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.308-323
    • /
    • 2021
  • An increasing number of adult congenital heart disease (ACHD) patients continue to require life-long diagnostic imaging surveillance using cardiac CT and MRI. These patients typically exhibit a large spectrum of unique anatomical and functional changes resulting from either single- or multi-stage palliation and surgical correction. Radiologists involved in the diagnostic task of monitoring treatment effects and detecting potential complications should be familiar with common cardiac CT and MRI findings observed in patients with repaired complex ACHD. This review article highlights the contemporary role of CT and MRI in three commonly encountered repaired ACHD: repaired tetralogy of Fallot, transposition of the great arteries after arterial switch operation, and functional single ventricle after Fontan operation.

Assessment of The Accuracy of The MR Abdominal Adipose Tissue Volumetry using 3D Gradient Dual Echo 2-Point DIXON Technique using CT as Reference

  • Kang, Sung-Jin
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.603-615
    • /
    • 2016
  • In this study, in order to determine the validity and accuracy of MR imaging of 3D gradient dual echo 2-point DIXON technique for measuring abdominal adipose tissue volume and distribution, the measurements obtained by CT were set as a reference for comparison and their correlations were evaluated. CT and MRI scans were performed on each subject (17 healthy male volunteers who were fully informed about this study) to measure abdominal adipose tissue volume. Two skilled investigators individually observed the images acquired by CT and MRI in an independent environment, and directly separated the total volume using region-based thresholding segmentation method, and based on this, the total adipose tissue volume, subcutaneous adipose tissue volume and visceral adipose tissue volume were respectively measured. The correlation of the adipose tissue volume measurements with respect to the observer was examined using the Spearman test and the inter-observer agreement was evaluated using the intra-class correlation test. The correlation of the adipose tissue volume measurements by CT and MRI imaging methods was examined by simple regression analysis. In addition, using the Bland-Altman plot, the degree of agreement between the two imaging methods was evaluated. All of the statistical analysis results showed highly statistically significant correlation (p<0.05) respectively from the results of each adipose tissue volume measurements. In conclusion, MR abdominal adipose volumetry using the technique of 3D gradient dual echo 2-point DIXON showed a very high level of concordance even when compared with the adipose tissue measuring method using CT as reference.

The Study for the Present Possession of CT and MRI and the Technologists's Awareness of Quality Control (대구지역 의료기관의 CT, MRI 보유 현황과 정도관리에 관한 담당 방사선사들의 인식 조사)

  • Lee, Chang-Suk;Jo, In-Seong;Lee, Sang-Uk;Jeong, Seok-Jong;Sung, A-Ra;Lee, Hyun-Jung;Hyung, Mi-Rim;Seong, Ji-Su;Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.117-126
    • /
    • 2011
  • This study concerns the present possession of CT and MRI machines in Daegu and the technologists' awareness of Quality Control. the study was conducted by visiting forty medical institutions as well as a survey. The survey was carried out by technologists responsible for CT and MRI. CT and MRI machines have only been used in medical institutions in Daegu for a short period. The study revealed that most of them have been acquired by those institutions recently. Most of the technologists who participated in the study are aware of the (prescribed) Quality Control measures and conduct regular inspections in accordance with the quality control chart, however some of them do not.

  • PDF

Comparison of X-ray computed tomography and magnetic resonance imaging to detect pest-infested fruits: A pilot study

  • Kim, Taeyun;Lee, Jaegi;Sun, Gwang-Min;Park, Byung-Gun;Park, Hae-Jun;Choi, Deuk-Soo;Ye, Sung-Joon
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.514-522
    • /
    • 2022
  • Non-destructive testing (NDT) technology is a widely used inspection method for agricultural products. Compared with the conventional inspection method, there is no extensive sample preparation for NDT technology, and the sample is not damaged. In particular, NDT technology is used to inspect the internal structure of agricultural products infested by pests. The introduction and spread of pests during the import and export process can cause significant damage to the agricultural environment. Until now, pest detection in agricultural products and quarantine processes have been challenging because they used external inspection methods. However, NDT technology is advantageous in these inspection situations. In this pilot study, we investigated the feasibility of X-ray computed tomography (X-ray CT) and magnetic resonance imaging (MRI) to identify pest infestation in agricultural products. Three kinds of artificially pest-infested fruits (mango, tangerine, and chestnut) were non-destructively inspected using X-ray CT and MRI. X-ray CT was able to identify all pest infestations in fruits, while MRI could not detect the pest-infested chestnut. In addition, X-ray CT was superior to the quarantine process than MRI based on the contrast-to-noise ratio (CNR), image acquisition time, and cost. Therefore, X-ray CT is more appropriate for the pest quarantine process of fruits than MRI.

THE PET/CT IN THE DIAGNOSIS OF ORAL CANCER: CLINICAL CASES (구강암의 진단에 사용되어지는 PET/CT: 임상 증례)

  • Kim, Sung-Jin;Kim, Yong-Kack;Kim, Chul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.2
    • /
    • pp.178-182
    • /
    • 2005
  • With the development of systemic diagnostic technique in cancer, the diagnostic methods of head and neck region are developing, also. Now, it is usually used computed tomography(CT), magnetic resornance image(MRI) in head and neck cancer and positron emission tomography(PET) is being increased in diagnostic use because of tumor specificity and accuracy. However, CT and MRI show the advantage of showing precise anatomical landmarks, but the disadvantage of these methods is much affecting by anatomical variations and changes. Otherwise, PET presents the imaging of physiologic and biochemical phenomenon and the disadvantage is the difficult differentiation of normal physiologic uptake, the lack of normal anatomical landmarks. PET/CT, the combination of clinical PET and CT imaging in a single unit is introduced recently, and it helps to get more accurate diagnostic interpretation and to improve in evaluating response to therapy, in management of patients with malignant tumors. So, we report the advantages of PET/CT in the diagnosis of oral cancer with review of literatures.

Neuropsychiatric Evaluation of Head-Injured Patients(I) : Comparison of Structural and Functional Brain Studies in Post-Traumatic Organic Mental Disorder (두부외상 환자의 신경정신의학적 평가(I) : 외상후 기질성정신장애 환자에서 뇌의 구조적 및 기능적 검사소견의 비교)

  • Yi, Jang Ho;Chang, Hwan-Il
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.1
    • /
    • pp.57-65
    • /
    • 1996
  • The Evaluation of patients complaining of psychiatric symptoms following head injury is much affected by the results of various tests. The objecive of this paper is to investigate the effectiveness of each lest by comparing the structual and fuctional brain studies. The subjects were 93 organic menial disorder in and out patients at the Dept. of Neuropsychiatry of the Kyung Hee University Hospital. After carrying out MRI, CT, SPECT, EEG, the results of each were analysed for the sesitivity and ability to detect focal lesion. The degree of inter-test correlations of lest results were also investigated. Furthermore, the characteristic features of psychological tests were studied and the relationship between each of above mentioned tests and psychological test was examined. As for the test sensitivity to diagnosis, the SPECT was the most superior followed by MRI, CT, EEG in thai order. In the case of abnormality, SPECT ranked 1st in detection of focal lesion, followed by MRI, CT in that order. In the inter-test result correlation, the correlation of SPECT-MRI was statistically significant. When mare than moderate abnormality EEG finding was reported, it correlated significantly with that of MRI findings. In the MMPI, the average scores on F, Hs, D, Hy, Pa, Pt, Sc subscales were above 60. Abnormal SPECT group scored significantly high on the F, Pd, Pa, Sc, Ma scales and therefore in comparison ot the SPECT normal group, displayed more psychotic features. In K-WAIS, the mean full scale IQ was down to 77. 23(Verbal IQ : 78.76, Performance IQ : 77.44) but there was no characterogic significant relationship between the lowered to and abnormal SPECT, MRI, CT and EEG results. In conclusion, 1) The SPECT was mast superior in sensitivity and detection of focal lesions. In comparision with other tests, the results of SPECT correlated well with MRI had thus is thought to be very usefull testing method in the evaluation of organic mental disorder patients. 2) The MRI had relatively high sensitivity, ability to detect focal lesion and superior correlation with other test. 3) Although EEG fared less an sensitivity in comparison to other tests, the results of above moderate abnormal grade group and that of MRI correlated significantly. 4) In the MMPI highly scored in F, Hs, D, Hy, Pa, Pt, Sc subscales and abnormal SPECT patients were shown to display more sever psychotic features. There was no significant character relationship between the lowered IQ(in K-WAIS) and abnormal findings on MRI, CT, SPECT, EEG.

  • PDF

Diagnostic Performance of Whole-Body Diffusion-Weighted Imaging Compared to PET-CT Plus Brain MRI in Staging Clinically Resectable Lung Cancer

  • Usuda, Katsuo;Sagawa, Motoyasu;Maeda, Sumiko;Motono, Nozomu;Tanaka, Makoto;Machida, Yuichiro;Matoba, Takuma Matsui Munetaka;Watanabe, Naoto;Tonami, Hisao;Ueda, Yoshimichi;Uramoto, Hidetaka
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.6
    • /
    • pp.2775-2780
    • /
    • 2016
  • Background: Precise staging of lung cancer is usually evaluated by PET-CT and brain MRI. Recently, however, whole-body diffusion-weighted magnetic resonance imaging (WB-DWI) has be applied. The aim of this study is to determine whether the diagnostic performance of lung cancer staging by WB-DWI is superior to that of PET-CT+brain MRI. Materials and Methods: PET-CT + brain MRI and WB-DWI were used for lung cancer staging before surgery with 59 adenocarcinomas, 16 squamous cell carcinomas and 6 other carcinomas. Results: PET-CT + brain MRI correctly identified the pathologic N staging in 67 patients (82.7%), with overstaging in 5 (6.2%) and understaging in 9 (11.1%), giving a staging accuracy of 0.827. WB-DWI correctly identified the pathologic N staging in 72 patients (88.9%), with overstaging in 1 (1.2%) and understaging in 8 patients (9.9%), giving a staging accuracy of 0.889. There were no significant differences in accuracies. PET-CT + brain MRI correctly identified the pathologic stages in 56 patients (69.1%), with overstaging in 7 (8.6%) and understaging in 18 (22.2%), giving a staging accuracy of 0.691. WB-DWI correctly identified the pathologic stages in 61 patients (75.3%), with overstaging in 4 (4.9%) and understagings in16(19.7%), giving a staging accuracy of 0.753. There were no significant difference in accuracies. Conclusions: Diagnostic efficacy of WB-DWI for lung cancer staging is equivalent to that of PET-CT + brain MRI.

Comparative Evaluations of Magnetic Resonance Image, Spiral Computed Tomography and Ultrasound in the Diasnosis of Experimental Diaphragmatic Rupture in the Rabbit (토끼의 횡격막 파열 진단에 있어서 자기공명영상, 나선형전산화단층촬영 및 초음파의 가치 비교)

  • 김학희;정승은;이배영;최병길;신경섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.154-161
    • /
    • 1997
  • Purpose: Traumatic rupture of the diaphragm is not easy to diagnose and often delayed. Delayed diagnosis of diaphragmatic rupture accompanied by higher chances of strangulation of herniated viscera which may result in higher morbility and mortality. The purpose of this study was to evaluate diagnostic accuracy of spiral CT, MRI and US for the diagnosis of diaphragmatic rupture in an animal model. Materials and Methods: Small, medium, and large sized transabdominal diaphragmatic ruptures were surgically made in experimental rabbits and then followed up with spiral CT, MR!, and US at 1 day, 3 day, and 1 week after operation. Results: US was superior to MR! or spiral CT in diagnosis of diaphragmatic rupture(P(0.05). The sensitivity and specificity were 94.4% and 92.9% for US, 54.0% and 85.7% for MRI, and 46.0% and 78.6% for spiral CT, respectively. The size of laceration was not related to diagnostic sensitivity in US. Sensitivity of MRI and spiral CT increased as the size of laceration were larger, but no statistical significance was present(P>0.05). All experimental animals developed pleural effusion or hemothorax one day after operation. In acute phase, US and MRI were more sensitive than spiral CT in detecting diaphragmatic rupture. Spiral CT was more sensitive than US and MRI in delayed phase but without statistical significance(P>0.05). In the experimental rabbits with accompanying visceral hernia through the diaphragmatic defect, diagnostic accuracy was found equally high among three image modalities(P>0.05). Conclusion: This study indicates that US is the most accurate diagnostic method in detecting injury to the diaphragm in a rabbit model. The findings obtained in this experimental study can be applied to the diaphragmatic rupture of human being.

  • PDF

The Organ projection system using holographic lens (홀로렌즈를 이용한 장기 투영 시스템)

  • Kim, dong young;Kim, dong hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.83-85
    • /
    • 2017
  • Generally, the current organ projection systems are the MRI and the CT. The MRI and the CT, (MRI) allow the surgeon to see the internal organs without incising the human body. However, since the images generated by the machines are 2D, it is difficult for doctors to observe the internal organs in three dimension. In this paper, we develop the augmented projection system for internal organs by using the augmented reality technology. The developed system shows the internal organs of the body using a holographic lens as a stereoscopic image and allows for doctors to examine the internal organs in detail.

  • PDF

Radiological Diagnosis for Posttraumatic Olfactory Dysfunction (외상 후 후각이상에 대한 방사선학적 진단)

  • Ahn, Jung Yong;Joo, Jin Yang;Chung, Tae Sub
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.12
    • /
    • pp.1570-1576
    • /
    • 2000
  • Objective : To evaluate objectively the sites of injury in patients with posttraumatic olfactory deficits and to suggest the diagnostic procedure for evaluation of posttraumatic anosmia. Methods : Ten patients with posttraumatic olfactory dysfunction were examined by means of olfactory testing, sinoscopy, contrast filled paranasal sinus computed tomography(contrast filled PNS CT) and magnetic resonance imaging(MRI). Five normal persons without olfactory dysfunction were also evauluated. The aerodynamic patency of olfactory cleft was examined by contrast filled PNS CT. The olfactory system(oflactory bulbs, olfactory tracts, inferior frontal region, hippocampi, or temporal lobes) was investigated in detail with MRI. The difference in the size of the olfactory bulb between normal volunteers and anosmic patients was evaluated by Student's t test. Results : Contrast filled dynamic CT scan was useful method for the evaluation of dynamic patency of the olfactory cleft. Paranasal CT scan of the all anosmic patients showed dynamic reflux of contrast media in olfactory cleft on valsalva maneuver. For the largest cross-sectional area and great height, the difference in olfactory bulb size between normal volunteers and patients was statistically significant(p<0.001) in MRI study. Conclusion : Posttraumatic anosmia was completely evaluated by olfactory testing, sinoscopy, and contrast filled CT scan for differentiation between conductive type and neurogenic type. Neurogenic anosmia was confirmed by perfect localization with MRI study.

  • PDF