• Title/Summary/Keyword: CSS System

Search Result 132, Processing Time 0.027 seconds

Real time indoor positioning system using IEEE 802.15.4a and sensors (IEEE 802.15.4a와 센서를 이용한 실시간 실내위치인식 시스템)

  • Cho, Hyun-Jong;Hwang, Kwang-Il;Noh, Duck-Soo;Seo, Dong-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.850-856
    • /
    • 2012
  • Bilateration using two fixed nodes has been used in the field of the real time indoor location system in the narrow space such as building or ship passage. However, as the distance between the fixed nodes increases or any obstructions exist in their zone, it is difficult to detect the location of mobile node(user) due to the degradation of its reception ratio. In order to compensate for these problems, this paper presents, based on IEEE 802.15.4a chirp signal, a new real time indoor location system using stride measurement algorithm which can calculate the location through sensors attached to user. The proposed system consists of an ultrasonic sensor to measure the leg length, a geomagnetic sensor to recognize the user's orientation, and an inertial sensor to obtain the angle between the legs. The experimental results are shown that the proposed system has twice or more accurate output compared with conventional indoor location method in the section which is partially out of communication reachability.

An Applicability Study of Action-Benefit-Cost Model and Statistical Model Checking for System of Systems Goal Achievement Verification (시스템 오브 시스템즈 수준의 목표 달성 검증을 위한 행동-이익-비용 모델과 통계적 모델 체킹 적용 연구)

  • Kim, Junho;Shin, Donghwan;Bae, Doo-Hwan
    • KIISE Transactions on Computing Practices
    • /
    • v.23 no.4
    • /
    • pp.256-261
    • /
    • 2017
  • The notion of System of Systems (SoS), which is composed by many independent systems (i.e., Constituent Systems, CS), has emerged in various domains including social infrastructure. It is widely expected that complex requirements, which cannot be achieved in each CS-level, will be achieved in an SoS-level. While verification of SoS-level goal achievement is one of the most important problems, concrete case studies on SoS modeling and verification are still rare. In this paper, we focus on the fact that each CS performs an action for its own purpose by its own decision-making mechanism. We propose a novel Action-Benefit-Cost (ABC) SoS model which caters to the independent decision-making mechanisms of CSs. Using an abstract SoS example, this proposal provides a case study for the modeling and quantitative verification of the ABC SoS model.

Drastic Brightness and Color Variations of the New Discovered Polar OTJ 071126+440405

  • Kim, Yong-Gi;Yoon, Joh-Na;Andronov, Ivan L.;Breus, Vitalii V.;Dubovsky, P.;Chinarova, Lidia L.;Han, Won-Yong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.59-59
    • /
    • 2012
  • Self-consistent mathematical model of the exotic object OTJ 071126+440405= CSS 081231:071126+440405 is discussed. The system was discovered as a polar at the New year night 31.12.2008/01.01.2009 by D.Denisenko (VSNET Circ), and we have initiated an international campaign of photometric and polarimetric observations of this object (totally -80 runs in Ukraine, Korea, Slovakia, Finland, USA) as a part of the "Inter-Longitude Astronomy" (ILA) project on monitoring of variable stars of different classes (Andronov et al., 2003). Here we present the geometrical and physical model of the system in the low luminosity state and in the intermediate luminosity state as well as in the high luminosity state. As the system is of -20 mag at minimum, no spectral observations were made to determine parameters of the red dwarf. From the statistical relationship, the mass of the red dwarf is estimated to be -0.165 solar masses, for the white dwarf (from eclipse duration) - from 0.5 to 1.76 solar masses. As the system resembles ER UMa in some characteristics, the lower value may be assumed. The inclination of the system and other physical parameters are estimated. The object is an excellent laboratory to study multiple physical processes in the magnetic systems.

  • PDF

The Effect of Microalgal Growth on Nutrient Sources Using Microalgal Small Scale Raceway Pond (SSRP) for Biodiesel Production (바이오디젤 생산을 위한 미세조류 옥외배양 시스템의 영양원에 따른 미세조류 성장 특성 비교)

  • Kim, Dong-Ho;Kim, Byung-Hyuk;Choi, Jong-Eun;Kang, Zion;Kim, Hee-Sik
    • Korean Journal of Microbiology
    • /
    • v.50 no.4
    • /
    • pp.313-318
    • /
    • 2014
  • The world is in need of sustainable and eco-friendly energy sources such as microalgal biodiesel due to global warming and fossil fuel shortages. In this study, we compared the effectiveness of liquid fertilizer produced from swine manure and agriculture grade solid fertilizers as nutrient sources for microalgal biomass production. Mixed culture (Chlorella spp., Scenedesmus spp., Stigeoclonium spp.; CSS) was cultivated for 28 days in Small Scale Raceway Pond (SSRP) using various nutrient sources (swine manure liquid fertilizer, agricultural solid fertilizer, and mixture of these two fertilizers). Biomass and lipid productivity of fertilizer mixture were the highest at 0.8 g/L and 5.8 mg/L/day, respectively. These results indicate that the fertilizer mixture can provide microalgae necessary nutrient sources for stable biodiesel production and biomass growth. In addition, overall cost of microalgal cultivation and subsequently biodiesel production would be significantly reduced.

Design of the COMS Satellite Ground Control System (통신해양기상위성 관제시스템 설계)

  • Lee, Byeong-Seon;Jeong, Won-Chan;Lee, Sang-Uk;Lee, Jeom-Hun;Kim, Jae-Hun
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.2
    • /
    • pp.16-24
    • /
    • 2006
  • As a multi-mission GEO satellite, COMS system is being developed jointly by KARI, ETRI, KORDI, KMA, and industries from both abroad and domestic. EADS ASRTIUM is the prime contractor for manufacturing the COMS. ETRI is developing the COMS Ka-band payload and SGCS with the fund from MIC. COMS Satellite Ground Control System (SGCS) will be the only system for monitor and control of the satellite in orbit. In order to fulfill the mission operations of the three payloads and spacecraft bus, COMS SGCS performs telemetry reception and processing, satellite tracking and ranging, command generation and transmission, satellite mission planning, flight dynamics operations, and satellite simulation, By the proper functional allocations, COMS SGCS is divided into five subsystems such as TTC, ROS, MPS, FDS, and CSS. In this paper, functional design of the COMS SGCS is described as five subsystems and the interfaces among the subsystems.

  • PDF

A Feasibility Study for the Application of the Cold-heat Storage System Considering the Real Operation Status of the Showcase (쇼케이스의 실제 운전상태를 고려한 축냉시스템 적용 가능성 평가 기초 연구)

  • Lee, Dong-Won;Kim, Jeongbae
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.52-58
    • /
    • 2012
  • Experimental study was performed to understand the real operation conditions of a showcase working usually in a convenient store and discount store. The purpose of this study was to show the possibility for practical use of cold-heat storage systems being operated for the showcase. To do that, evaporator and condenser temperatures were measured and the compressor electric power consumption were measured simultaneously. To use the ice storage system, the ice making process was typically operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was subcooled using the stored cold-heat after being discharged from the condenser during daytime. So, the cooling performance was increased with the sub-cooling of refrigerant during daytime,hence the actual running time of the compressor could be effectively decreased. Through the experiments, this study showed that the compressor electric power consumption during daytime could be transferred to nighttime for applying the refrigerant sub-cooling. So, for the convenient store, the maximum load transfer rates for each working cooler and showcase were estimated about 31.1% and 19.9% respectively. And for the discount store, the maximum load transfer rates for each refrigeration and freezing showcase were estimated about 34.1% and 49.0% respectively.

Inhibitory Effects of SGX01 on Lung Injury of COPD Mice Model (만성폐쇄성폐질환 동물모델에서 SGX01의 폐손상 억제 효과)

  • Park, Jae-jun;Yang, Won-kyung;Lyu, Yee Ran;Kim, Seung-hyung;Park, Yang Chun
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.4
    • /
    • pp.567-581
    • /
    • 2019
  • Objective: This study aimed to evaluate the inhibitory effects of SGX01 on the lung injuries of COPD mice model. Materials and Methods: This study was carried out in two ways: in vitro and in vivo. In vitro, L929 cells were challenged with LPS, and then treated with six concentrations of SGX01 (10, 30, 50, 100, 300, and $500{\mu}g/ml$) and analyzed by ELISA. In vivo, C57BL/6 mice were challenged with LPS and cigarette smoking solution (CSS), and then treated with a vehicle only (control group), dexamethasone 3 mg/kg (dexa group), or a SGX01 200 mg/kg (SGX01 group). After sacrifice, the BALF or lung tissue was analyzed with Cytospin, FACS, ELISA, real-time PCR and H&E, and Masson's trichrome staining. Results: SGX01 significantly decreased NO, $TNF-{\alpha}$, and IL-6 on L929 cells challenged with LPS. In the COPD model, SGX01 significantly inhibited the increase of neutrophils, $TNF-{\alpha}$, IL-17A, CXCL-1, MIP2, CD8+ cells in BALF, and $TNF-{\alpha}$, $IL-1{\beta}$ mRNA expression in lung tissue. It also decreased the severity of the histological lung injury. Conclusion: This study suggests the usability of SGX01 for COPD patients by controlling lung tissue injury.

Estimation of Discharge Load due to Combined Sewer Overflows in the Management of Total Maximum Daily Loads (수질오염총량관리 관거월류부하 변화에 따른 배출부하량 산정방법)

  • Park, Jun Dae;Oh, Seung Young;Choi, Ok Youn
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.3
    • /
    • pp.293-299
    • /
    • 2011
  • The quantity of a discharge load can change with changes in rainfall in the area with a combined sewer system (CSS). To evaluate the implementation appropriately in the management of total maximum daily loads (TMDLs), the effects of rainfall changes should be considered in the estimation of the discharge load. The rainfall condition for the estimation of the discharge load in a certain year should be standardized to the same rainfall condition as that of the reference year. However, the calculation process is very complicated with its potential limitations. This study investigated and developed relatively simple methods for estimating the discharge load. Load conversion method (LCM) is designed to convert the discharge load under the current rainfall condition into that of the reference rainfall conditions. Simple rainfall data method (SRDM) is to simplify the estimation process of the discharge load by the simple conversion of rainfall data. These methods were applied to calculate the discharge load and examine the estimation results. From the results of this study the application of these methods may be useful for estimating the discharge load in the TMDL process.

A Post-Implementation Assessment of the Effectiveness of a Separate Sewer System in Improving River Water Quality

  • Reyes, Nash Jett;Geronimo, Franz Kevin;Guerra, Heidi;Choi, Hyeseon;Jeon, Minsu;Kim, Lee-Hyung;Ku, Jin Hye;Jun, Kyung Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.241-241
    • /
    • 2021
  • Recent developments recommend the use of SSS to prevent combined sewer overflows and reduce excessive pollutant deposition in the receiving waters; however, other studies also suggest that SSS have minimal or no advantage over CSS in terms of reducing the pollutant loads being discharged in natural waterways. This study was conducted to evaluate the effectiveness of employing SSS in improving the water quality of the rivers in Okcheon-gun, South Korea. The former combined sewer outfalls (CSOs) were monitored to determine the presence of illicit connections or leaks in the newly-established SSS. Dry and wet-day monitoring was conducted alongside the collection of water samples on 14 points along the reach of the rivers and four former CSOs to determine water quality changes and patterns of pollutant loading. Among the 34 former CSOs in the study area, eight former CSOs exhibited dry-day discharges, implying the possibility of having illicit connections, leaks, or illegal wastewater discharge in the system. Moreover, relatively high biochemical oxygen demand (BOD) chemical oxygen demand (COD) concentrations, ranging from 4.8 mg/L to 24.9 mg/L and 6.4 mg/L to 10.1 mg/L, respectively were observed on three out of the four monitored CSOs. Fluctuations in the pollutant concentrations in the different monitored points along the river was also observed due to the presence of pipes discharging polluted water. Ultimately, further studies are necessary to identify the sources of dry-day discharges in the CSOs to successfully improve the water quality of the rivers in the area.

  • PDF

Head-Disk Interface : Migration from Contact-Start-Stop to Load/Unload

  • Suk, Mike
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.643-651
    • /
    • 1999
  • A brief description of the current technology (contact-start-stop) employed in most of today's hard disk drive is presented. The dynamics and head/disk interactions during a start/stop process are very complicated and no one has been able to accurately model the interactions. Thus, the head/disk interface that meets the start/stop durability and stiction requirements are always developed statistically. In arriving at a solution. many sets of statistical tests are run by varying several parameters. such as, the carbon overcoat thickness. lubricant thickness. disk surface roughness, etc. Consequently, the cost associated III developing an interface could be significant since the outcome is difficult to predict. An alternative method known as Load/Unload technology alters the problem set. such that. the start/stop performance can be designed in a predictable manner. Although this techno¬logy offers superior performance and significantly reduces statistical testing time, it also has some potential problems. However. contrary to the CSS technology. most of the problems can be solved by design and not by trial and error. One critical problem is that of head/disk contacts during the loading and unloading processes. These contact can cause disk and slider damage because the contacts are likely to occur at high disk speeds resulting in large friction forces. Use of glass substrate disks also may present problems if not managed correctly. Due to the low thermal conductivity of glass substrates. any head/disk contacts may result in erasure due to frictional heating of the head/disk interface. In spite of these and other potential problems. the advantage with L/UL system is that these events can be understood. analyzed. and solved in a deterministic manner.

  • PDF