• 제목/요약/키워드: CSPF

검색결과 10건 처리시간 0.021초

M_CSPF: A Scalable CSPF Routing Scheme with Multiple QoS Constraints for MPLS Traffic Engineering

  • Hong, Daniel W.;Hong, Choong-Seon;Lee, Gil-Haeng
    • ETRI Journal
    • /
    • 제27권6호
    • /
    • pp.733-746
    • /
    • 2005
  • In the context of multi-protocol label switching (MPLS) traffic engineering, this paper proposes a scalable constraintbased shortest path first (CSPF) routing algorithm with multiple QoS metrics. This algorithm, called the multiple constraint-based shortest path first (M_CSPF) algorithm, provides an optimal route for setting up a label switched path (LSP) that meets bandwidth and end-to-end delay constraints. In order to maximize the LSP accommodation probability, we propose a link weight computation algorithm to assign the link weight while taking into account the future traffic load and link interference and adopting the concept of a critical link from the minimum interference routing algorithm. In addition, we propose a bounded order assignment algorithm (BOAA) that assigns the appropriate order to the node and link, taking into account the delay constraint and hop count. In particular, BOAA is designed to achieve fast LSP route computation by pruning any portion of the network topology that exceeds the end-to-end delay constraint in the process of traversing the network topology. To clarify the M_CSPF and the existing CSPF routing algorithms, this paper evaluates them from the perspectives of network resource utilization efficiency, end-to-end quality, LSP rejection probability, and LSP route computation performance under various network topologies and conditions.

  • PDF

PF 열교환기를 적용한 공조기의 성능 비교 실험연구 (Experimental Study on Performance Comparison of Air-Conditioner with PF Heat Exchanger)

  • 권영철;박윤창
    • 한국산학기술학회논문지
    • /
    • 제10권3호
    • /
    • pp.470-475
    • /
    • 2009
  • 본 연구에서는 핀-관 열교환기와 PF 열교환기의 열전달 특성과 이를 적용한 공조기의 성능을 비교 조사하였다. 또한 공조기의 냉방기간 에너지효율(CSPF)을 평가하였다. 열교환기 실험을 위해 3종류의 열교환기에 대한 열전달 및 압력강하를 그리고 공조기 성능평가를 위해 냉방표준, 냉방저온에서 냉방능력, 소비전력, COP를 산출하였다. 실험은 칼로리미터와 항온수조를 사용하여 수행되었다. 유입공기 속도가 증가함에 따라 열교환기의 열전달율과 압력강하는 증가하였다. PF 열교환기 적용 시스템의 적정 냉매량은 핀-관공조기보다 약 $15{\sim}20%$ 감소하였으나, 냉방능력은 증가, 소비전력은 감소하여 COP는 향상되었다. 사각형 핀을 가진 PF 열교환기가 삼각형 핀보다 냉방능력과 COP가 더 우수하였다. 실환경 온도조건을 반영하기 위해 PF 열교환기와 핀-관 열교환기 적용 시스템의 CSPF가 계산되었다.

QoS 서비스와 최선형 서비스를 위한 효율적인 MPLS 라우팅 시스템 (An Efficient MPLS Routing System for Supporting QoS and Best-Effort Services)

  • 전한얼;김성대;신용철;이재용;김형택
    • 한국통신학회논문지
    • /
    • 제28권1B호
    • /
    • pp.71-79
    • /
    • 2003
  • 인터넷에서 트래픽의 폭발적인 증가로 인하여 데이터 흐름에 대한 서비스품질(QoS) 보장과 트래픽 엔지니어링 문제가 매우 중요하게 되었다 MPLS는 출발지와 목적지 사이에 다중의 경로를 사용하는 데 자유롭기 때문에 기존의 IP 라우팅보다 이러한 문제를 해결하는데 장점을 갖고 있다 특히 제한기반 최소 거리(CSPF) 알고리즘과 MPLS의 explicit 결로는 위의 문제를 해결하도록 해주었다. 그러나, CSPF 알고리즘은 QoS 제한 이내의 최소 거리 경로를 찾기 때문에 QoS가 만족되는 다른 경로를 찾을 수 없으며, 트래픽이 몰리는 정체가 발생하였을 경우 최선형(best-effort) 트래픽 데이터는 잃게 된다. 본 논문에서는 MPLS 망에서 트래픽을 분산시키는 라우팅을 통해 네트워크 자원을 최적으로 사용하는 방안을 제시한다

PF 열교환기를 적용한 공조기의 성능에 대한 실험연구 (Experimental Study on Performance of Air-conditioner with PF Heat Exchanger)

  • 서동남;엄유식;박경만;이상재;김대훈;권영철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.525-530
    • /
    • 2008
  • In the present study, the cooling performances of the air-conditioner applied the fin-tube and aluminum PF heat exchangers have been experimentally investigated by using the calorimeter. The experiment is carried out in the conditions of the standard temperature and the low temperature. Fin type of PF heat exchanger is a triangler and squarer form. PF heat exchanger has smaller refrigerant weight and larger capacity and COP han the fin-tube heat exchanger. The performance of PF-2 heat exchanger with the squarer in is more excellent than that of PF-1 heat exchanger with the triangler fin. The high pressure of PF heat exchanger decreases about 7%, compared to the fin-tube heat exchanger. Also, CSPF of the fin-tube and PF heat exchanger is evaluated.

  • PDF

KREONET OpenFlow 네트워크 테스트베드 기반의 QoS 라우팅 경로 제어 구현 (Implementation of a QoS routing path control based on KREONET OpenFlow Network Test-bed)

  • 김승주;민석홍;김병철;이재용;홍원택
    • 대한전자공학회논문지TC
    • /
    • 제48권9호
    • /
    • pp.35-46
    • /
    • 2011
  • 미래인터넷은 효과적인 이동성 처리, 유연한 트래픽 엔지니어링 기술 및 다양한 새로운 응용 지원이 이루어져야 한다. 이에 따라 많은 트래픽 엔지니어링 기술들이 제안되고 개발되어 왔지만 이를 실제 운용 중인 상용 인터넷 망에 적용하는 것은 매우 어려운 것이 사실이다. 이 문제를 해결하기 위해 다양한 네트워킹 관련 응용을 지원하는 컨트롤러를 사용해 망의 장비를 제어할 수 있는 OpenFlow 기법이 제안되었다. 이는 소프트웨어 적으로 정의된 망으로 연구자들이 자신 만의 트래픽 엔지니어링 기법을 컨트롤러에 적용하여 그 유용성을 검증할 수 있다. 한편 고속 패킷 처리를 지원하는 OpenFlow 망의 구축을 위해 4개의 1G 인터페이스를 가지는 프로그래밍 가능한 NetFPGA 카드와 상용 Procurve 스위치 들이 사용될 수 있다. 본 논문에서는 하드웨어 가속 기능이 지원되는 NetFPGA 카드와 Procurve 스위치를 KREONET 망에 적용한 OpenFlow 테스트베드를 구축하고 가장 보편적인 QoS 라우팅 기법인 CSPF 알고리즘을 구축한 대규모 테스트베드 상에 적용하여 멀티미디어 트래픽 엔지니어링 기법의 성능 및 유효성 검증을 수행하였다.

An Energy Efficient Algorithm Based on Clustering Formulation and Scheduling for Proportional Fairness in Wireless Sensor Networks

  • Cheng, Yongbo;You, Xing;Fu, Pengcheng;Wang, Zemei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권2호
    • /
    • pp.559-573
    • /
    • 2016
  • In this paper, we investigate the problem of achieving proportional fairness in hierarchical wireless sensor networks. Combining clustering formulation and scheduling, we maximize total bandwidth utility for proportional fairness while controlling the power consumption to a minimum value. This problem is decomposed into two sub-problems and solved in two stages, which are Clustering Formulation Stage and Scheduling Stage, respectively. The above algorithm, called CSPF_PC, runs in a network formulation sequence. In the Clustering Formulation Stage, we let the sensor nodes join to the cluster head nodes by adjusting transmit power in a greedy strategy; in the Scheduling Stage, the proportional fairness is achieved by scheduling the time-slot resource. Simulation results verify the superior performance of our algorithm over the compared algorithms on fairness index.

에어컨의 냉방기간 에너지 효율 산출을 위한 실험적 연구 (Experimental Study on the Cooling seasonal Performance Factor of Room Air-conditioner)

  • 이홍원;문정호;배영돈;박종철
    • 설비공학논문집
    • /
    • 제4권3호
    • /
    • pp.204-216
    • /
    • 1992
  • In most cases, EER(Energy Efficiency Ratio) is available to present energy efficiency of air-conditioners. But, EER is not adapt to measure energy efficiency at actual life environment because it is based on fixed temperature and humidity contditions. To overcome this disadvantage, there is need to introduce SEER(Seasonal Energy Efficiency Ratio) established at time varient temperature and humidity conditions. In this paper, SEER measurement method and conditions based on actual life environment of the country is introduced, and discussed SEER value about two air-conditioner type, that is, non inverter air-conditioner and inverter air-conditioner. As a result of, inverter air-conditioner was superior to non inverter air-conditioner at cooling seasonal energy efficiency.

  • PDF

MPLS 트래픽 엔지니어링을 위한 다중경로 Constraint-based 라우팅 알고리즘 (Muli-path Constraint-based Routing Algorithms for MPLS Traffic Engineering)

  • Lee, Jae-Young;Kim, Byung-Chul
    • 한국통신학회논문지
    • /
    • 제29권5B호
    • /
    • pp.508-519
    • /
    • 2004
  • 이 논문에서는 MPLS를 사용한 인터넷 트래픽 엔지니어링에 사용될 수 있는 다중경로 한계조건 기반 라우팅 알고리즘을 제안한다. 기존에 사용되던 한계조건 기반 최단경로 라우팅 알고리즘은 트래픽 엔지니어링의 중요한 요소 중에 하나인 대역폭 한계조건이 큰 간을 가지는 경우에는 조건을 만족하는 경로를 찾지 못할 확률이 높아진다. 제안된 다중경로 알고리즘은 대역폭 한계조건을 만족하는 하나의 경로를 찾을 수 없는 경우, 대역폭 조건을 여러 개의 작은 값으로 나누어 각각의 작은 대역폭 한계조건에 대해 다중경로를 찾는 알고리즘이다. 시뮬레이션을 통하여 제안한 알고리즘을 사용할 경우 주어진 네트웍 상황과 대역폭 한계 조건에서 더 높은 경로설정 성공확률을 나타내며, 네트웍 자원 이용률도 개선되는 것을 보였다.

가정용 지열원 열펌프 시스템의 냉난방 성능 특성 연구 (An Experimental Study on the Cooling and Heating Performance of a Residential Ground Source Heat Pump System)

  • 공형진;강성재;윤경식;임효재
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.156-163
    • /
    • 2013
  • Ground Source Heat Pump (GSHP) systems utilize geothermal energy as a thermal source or sink, for heating, cooling and domestic hot water. It is well known that GSHP is environmentally friendly, and saves energy dramatically. For this reason, many investigative researches have been conducted on commercial and governmental buildings. However, studies on residential GSHP are few, because of the small capacity and cost. In this study, we experimented with the characteristic performance of heating, cooling and seasonal performance factor for a residential GSHP system, which consisted of two 180 m deep u-tube ground heat exchangers, a heat pump and measurement instruments. The installed capacity of the heat pump was 5RT, and the conditioning area was $62.23m^2$. From the experimental results, the cooling COP of the heat pump was 4.13, and the system COP was 3.51, while the CSPF was 3.32. On the other hand, the heating COP of the heat pump was 3.87, and the system COP was 3.39, while the HSPF was 3.39. Also, in-situ cooling COP and capacity were 93.7% and 96.4% compared with the EWT certification data, respectively, and that of heating were 98.3% and 95.7%, respectively.

부분부하 조건에서 히트펌프의 운전변수 최적화를 통한 냉방계절성능(SEER) 향상에 관한 실험적 연구 (An Experimental Study on the Performance Improvement of the Seasonal Energy Efficiency Ratio(SEER) of a Heat Pump by Optimizing Operating Parameters under Partial Load Conditions)

  • 최성경;이상헌;김선재;김용찬
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.111-118
    • /
    • 2017
  • Performance factors such as the EER(Energy Efficiency Ratio) and the COP (Coefficient of Performance) are being replaced by seasonal energy efficiency factors, like the SEER (Seasonal EER) and the SCOP (Seasonal COP) to evaluate the performance of a heat pump by the time of the year. Seasonal performance factors, such as the CSPF (Cooling Seasonal Performance Factor) and the HSPF (Heating Seasonal Performance Factor) are used to describe the heat pump's performance during the cool and hot seasons. In this study, the optimization of all heat pump's operating parameters was experimentally conducted to enhance the SEER based on the EU standard (EN 14825). Moreover, the SEER was improved by the compressor frequency, as well as indoor and outdoor fan speeds. In addition, the performance characteristics of the heat pump were studied under partial load conditions. As a result, the SEER was enhanced by 17% when the compressor frequency was optimized. An additional 2% improvement was achievable with the optimization of indoor and outdoor fan speeds.