• Title/Summary/Keyword: CRT mode

Search Result 25, Processing Time 0.024 seconds

Efficient implementation of AES CTR Mode for a Mobile Environment (모바일 환경을 위한 AES CTR Mode의 효율적 구현)

  • Park, Jin-Hyung;Paik, Jung-Ha;Lee, Dong-Hoon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.5
    • /
    • pp.47-58
    • /
    • 2011
  • Recently, there are several technologies for protecting information in the lightweight device, One of them, the AES[1] algorithm and CRT mode, is used for numerous services(e,g, OMA DRM, VoIP, IPTV) as encryption technique for preserving confidentiality. Although it is possible that the AES algorithm CRT mode can parallel process transmitting data, IPTV Set-top Box or Mobile Device that uses these streaming service has limited computation-ability. So optimizing crypto algorithm and enhancing its efficiency for those environment have become an important issue. In this paper, we propose implementation method that can improve efficiency of the AES-CRT Mode by improving algorithm logics. Moreover, we prove the performance of our proposal on the mobile device which has limited capability.

Failure Mode Analysis of Mo-tip EFA Cold-Cathode in CRT Spot-knocking Process (CRT의 Spot-knocking 공정에 있어서 몰리브텐 팁 전계 방출 소자 냉응극의 고장 형태 분석)

  • Ju, Byeong-Kwon;Kim, Hoon;Park, Jong-Won;Kim, Nam-Soo;Kim, Dong-Ho;Lee, Yun-Hi
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.414-418
    • /
    • 2001
  • Failure modes of Mo-tip FEA were investigated in detail as a preliminary study for the application of Mo-tip FEA to the CRT electron-gun as a cold cathode. It was identified that the destruction of Mo-tip FEA was originated from reflowing of arc-current during the spot-knocking process followed by secondary arc between gate electrode and cathode substrate. In order to prevent Mo-tip FEA from destruction due to arc-current, two kinds of methods were suggested, that is one is to provide the by-pass of the reflow current and the other is to install a current limiter in the path of gate connection line.

  • PDF

A Study on Parallel-mode CRT Interfacting Technique in Microcomputer System and Prototype Program development System (마이크로 컴퓨터의 병렬형 CRT 입출력 방식과 Prototype Program development System에 관한 연구)

  • 정창경
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.14 no.4
    • /
    • pp.9-14
    • /
    • 1977
  • A parallel mode CRT interfacing technique has been suggested for a microcomputer system. The number of components and the I/O speed were improved significantly by this technique. As an appliation of this technique, a prototype program develoment system was designed and tested experimentally for the use fulness in prototype program developmenting.

  • PDF

An Analysis of the Mask Vibration Considering the Damping Wire (와이어와의 접촉을 고려한 마스크의 진동 해석)

  • 유세준;신운서;장보웅
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.7
    • /
    • pp.203-208
    • /
    • 2000
  • The vibration of a mask degrades the color purity in CRT Therefore, a damping wire is put into contact with the mask to reduce the vibration in perfectly flat CRT. In this study, we analyzed the vibration of the mask contacting with the damping wire using FEM. First we calculated the natural frequencies and mode shapes of the mask by modal analysis, and compared them with the measured results to confirm our finite element model. The modal analysis of the wire was also performed to investigate resonance with the mask. Finally, the transient dynamic analysis of the mask contacting with the wire was performed. The vibration of the mask was measured to confirm our analysis, and the results are in good agreement with the analysis.

  • PDF

Clinical Application Analysis of 3D-CRT Methods Using Tomotherapy (토모테라피를 이용한 3차원 입체 조형 치료의 임상적 적용 분석)

  • Cho, Kang-Chul;Kim, Joo-Ho;Kim, Hun-Kyum;Ahn, Seung-Kwon;Lee, Sang-Kyoo;Yoon, Jong-Won;Cho, Jeong-Hee;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.327-335
    • /
    • 2013
  • This study investigates the case of clinical application for TomoDirect 3D-CRT(TD-3D) and TomoHelical 3D-CRT(TH-3D) with evaluating dose distribution for clinical application in each case. Treatment plans were created for 8 patients who had 3 dimensional conformal radiation therapy using TD-3D and TH-3D mode. Each patients were treated for sarcoma, CSI(craniospinal irradiaion), breast, brain, pancreas, spine metastasis, SVC syndrome and esophagus. DVH(dose volume histogram) and isodose curve were used for comparison of each treatment modality. TD-3D shows better dose distribution over the irradiation field without junction effect because TD-3D was not influenced by target length for sarcoma and CSI case. In breast case, dosimetric results of CTV, the average value of D 99%, D 95% were $49.2{\pm}0.4$ Gy, $49.9{\pm}0.4$ Gy and V 105%, V 110% were 0%, respectively. TH-3D with the dosimetric block decreased dose of normal organ in brain, pancreas, spine metastasis case. SCV syndrome also effectively decreased dose of normal organ by using dose block to the critical organs(spinal cord <38 Gy). TH-3D combined with other treatment modalities was possible to boost irradiation and was total dose was reduced to spinal cord in esophagus case(spinal cord <45 Gy, lung V 20 <20%). 3D-CRT using Tomotherapy could overcomes some dosimetric limitations, when we faced Conventional Linac based CRT and shows clinically proper dose distribution. In conclusion, 3D-CRT using Tomotherapy will be one of the effective 3D-CRT techniques.

Merging of SPOT P-mode and XS-mode Images using Color Transformation and Image Enhancement (색변환과 영상개선기법을 이용한 SPOT P-mode와 XS-mode 영상합성)

  • 손덕재;이종훈
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.9 no.2
    • /
    • pp.103-113
    • /
    • 1991
  • The accuracy of input coordinates of ground control points and check points affects great influences to the results of ground coordinate computation in using SPOT digital image data. The original SPOT images displayed on CRT are not usually adequate for identifying the object features and determining the point positioning. Hence, appropriate image processing techniques such as contrast enhancement, subpixel interpolation, edge enhancement, and spatial filtering are needed. In this study, the principles of digital image processing needed for accurate three dimensional positioning and spectral characteristic analysis are investigated. The algorithms for the actual applications are developed and programmed. And using the developed image processing software, some SPOT P-mode and XS-mode images are merged into the SPOT P+XS, the high-resolution color composite image.

  • PDF

A Comparative Evaluation on Visual Performance of CRT and TFT-LCD as Desktop Computer Displays (데스크탑용 CRT와 TFT-LCD의 시각 작업수행도 비교·평가)

  • Kim, Sang-Ho;Choi, Kyung-Lim
    • Journal of the Ergonomics Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.95-112
    • /
    • 2002
  • Two experiments were carried out to compare the suitability in visual tasks between cathode-ray tube (CRT) and thin film transistor-liquid crystal display (TFT-LCD). In the first experiment, the subjects were requested to detect pre-assigned target words or icons among distracters presented under time-invariant (static) image mode. The subjects' visual performance and fatigue were assessed while carrying out search tasks with dim and bright ambient light conditions. Significant interaction effects were found among displays, task types, and ambient light conditions. Due to visual fatigue, the subjects' accommodative power decreased in the end of task and the degradation was more significant for the CRT users and under bright ambient light. IN the second experiment, the subjects performed information processing task with time-varying road signs at a driving simulator to assess interaction effects between display types and changing speed of dynamic image. The perception time using TFT-TCD was shorter under slow image change while that of CRT was shorter rapid image change. Findings from this study suggest that, to improve visual task performance, users should carefully select their visual display type depending on the task to be performed.

Evaluation of Treatment Planning for Head Tilting in WBRT 3D-CRT by TomoDirect mode: a Phantom Study (토모다이렉트를 이용한 3차원 전뇌 방사선치료에서 두상 각도에 따른 치료계획평가: 팬톰 실험)

  • Dae-Gun, Kim;Sang-Hyun, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.857-862
    • /
    • 2022
  • The purpose of this study was to evaluate a three-dimensional conformal radiotherapy (3D-CRT) treatment plan with regard to head tilting in whole-brain radiotherapy (WBRT) using TomoDirect (TD) mode in Tomotherapy. WBRT 3D-CRT by TD was compared for a total of five head tilt angles (-20°, -10°, 0°. +10° and +20°). The dose homogeneity index (HI) and prescription dose index (CI) were calculated to confirm the target coverage. The maximum and average doses for critical organs such as the lens, eyeball and parotid glands were calculated for different angles of head tilting. The HI and CI were closet to the result value of 1 at the head tilted angle +10° and +20°. At a head tilted angle of +10°, the dose to the lens and eyeballs decreased by about 74% and about 30%, when compared with the reference angle (0°), respectively. The results of this study suggest that a head angle of +10 with chin-up would save adequate target coverage and reduce exposure dose to the lens.

The effects of short persistent CCFL in Blinking Back Light Unit to reduce blur on TFT-LCD

  • Han, J.M.;Bae, K.W.;Kim, S.Y.;Kim, Y.H.;Lim, Y.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.694-697
    • /
    • 2003
  • In applying LCD to TV application, one of the most significant factors to be improved is image sticking on the moving picture. LCD is different from CRT in the sense that it's continuous passive device, which holds images in entire frame period, while impulse type device generate image in very short time. To reduce image sticking problem related to hold type display mode, we made an experiment to drive LCD like CRT. We made articulate images by turn on-off backlight, and we realized the ratio of Back Light on-off time by adjusting between on time and off time for video signal input during 1 frame (16.7ms). Conventional CCFL (cold cathode fluorescent lamp) cannot follow fast on-off speed, so we evaluated new fluorescent substances of light source to improve residual light characteristic of CCFL. We realized articulate image generation similar to CRT by blinking drive. As a result, reduced image sticking phenomenon was validated by naked eye and response time measurement.

  • PDF

Development of OCB mode with impulsive driving scheme for improving moving picture quality

  • Kim, J.L.;Lee, C.H.;Park, S.Y.;Yoo, S.W.;Oh, J.H.;Lee, S.H.;Chai, C.C.;Park, C.W.;Ban, B.S.;Ahn, S.H.;Hong, M.P.;Chung, K.H.;Lim, S.K.;Kim, K.H.;Souk, J.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1049-1052
    • /
    • 2004
  • In general, contrary to the CRTs with impulsive emission, liquid crystal displays have motion artifacts such as blurring. ghost image, decrease of dynamic CR(contrast ratio), and stroboscopic motion due to hold type driving method. In this paper, to improve motion picture quality of LCDs. impulsive driving method of black data insertion was applied to the OCB mode which is well known for its fast LC response time and wide viewing angle properties. Subject evaluation was carried out with CRT, TN, SIPS(Super IPS). and impulsive driving OCB. Moving picture image quality near CRT was obtained in impulsive OCB driving mode

  • PDF