• Title/Summary/Keyword: CRT cathode

Search Result 79, Processing Time 0.01 seconds

Fabrication and Characterization of Cold Cathode Electron-gun of CRT using Mo-tip Field Emitter Array (몰리브덴 팁 전계 방출 소자를 이용한 CRT의 냉음극 전자총의 제조 및 특성 평가)

  • Ju, Byeong-Kwon;Kim, Hoon;Seo, Sang-Won;Park, Jong-Won;Lee, Yun-Hi;Kim, Nam-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.409-413
    • /
    • 2001
  • In the electron-gun of CRT, the Mo-tip FEA was employed as cold cathode in order to replace the conventional thermal cathode. The Mo-tip FEA was designed and fabricated according to CRT specification and mounted on the electron-gun. It was known that fabricated cold cathode electron-gun showed better performance in terms of maximum emission current and switch-on time when compared with the ones of thermal cathode electron-gun, but some geometrical structures in the inside of electron-gun must be changed to reduce the gate leakage current. Finally, the potential applicability was guaranteed by means of operating the 19 inch-sized LG-color CRT using the fabricated cold cathode electron-gun.

  • PDF

Low Power Design on Heater and Cathode of Electron Gun for High Resolution CRT (고해상도 CRT용 전자총의 히터 및 캐소드 저전력 설계)

  • Kim Hack-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.618-625
    • /
    • 2005
  • This paper has achieved that an optimal design and experiments of heater and cathode of electron gun that serve to embody high current density in CRT display. For the high brightness, high resolution and larger size in CRT display, high current density of electron gun is indispensible. An Impregnation style cathode is used, and must heighten operating temperature of heater to get high current density for this, it is proportional hereupon and power dissipation increases. In this paper, to get low power cathode with high current density, There are produced and tested sample that differ lead type of heater, coating method, the pitch and number of winding of the first and second coiling in the heat emission area for the low power design of high current density cathode heater in this paper.

A study on the non-contact measurement for the temperature of shadow mask of Cathode Ray Tube using InSb photo sensor (인듐안티모나이드 포토 센서를 이용한 CRT 섀도우 마스크의 비접촉 온도 측정에 관한 연구)

  • 강대진;박정우;송창섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.3
    • /
    • pp.15-20
    • /
    • 1997
  • This paper presents the experimental study of the non-contact temperature measurement for the shadow mask of cathode ray tube using InSb sensor. At present, High resolution of CRT(Cathode Ray Tube) is needed broadly; therefore, the measurement of temperature distribution of shadow mask in CRT during operation is important to analyze the thermal deformation of shadow mask. Most of the studies could not measure the temperature distribution of shadow mask precisely. We studied the temperature dis- tribution of shadow mask using InSb photo sensor for 17" cathode ray tube (CRT). Experiments using ther- mocouple are performed to validate the results of non-contact measurement. The results agree well with those results of non-contact method using InSb sensor.nsor.

  • PDF

When Methane is decomposed on the CRT Manufacturing Process

  • Lee, Byoung-Joo;Hong, Sang-Pyo;Ko, Byoung-Doo;Hwang, Cheol-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.1051-1052
    • /
    • 2002
  • Vacuum surroundings in Cathode Ray Tubes (CRT) are very important factor for CRT lifetime, especially cathode & getter's. A getter is a very good vacuum pump; unfortunately, it cannot absorb an inert gas and hydrocarbons. There are only argon and helium in CRT after $1^{st}$ emission test because other active gases are absorbed by getter and methane is decomposed during CRT working. It is also very important to know exactly where and when methane is decomposed during the CRT manufacturing process, because methane is known to be harmful to cathode when its amount is high, and getter can't absorb the methane.

  • PDF

Emission Profile Studies of Thermionic Cathodes and Field Emitters

  • Tawa, Yasuhiro;Kai, Junjiro;Tama, Masayoshi;Ijima, Kenji;Saito, Tsunenari
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.371-375
    • /
    • 2002
  • Emissions of thermionic cathodes and field emitters were studied using a cathode emission profiler which works based on the anode scanning method. Findings about impregnated cathodes in thermal activation and gas poisoning processes are shown. Effects of surface treatments for field emitters are studied from the viewpoint of emission profiles and characteristics of the emitters.

  • PDF

Structural Design of a Cathode-ray Tube (CRT) to Improve its Mechanical Shockproof Character

  • Park, Sang-Hu;Kim, Won-Jin
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.9
    • /
    • pp.1361-1370
    • /
    • 2006
  • An electronic beam mis-landing phenomenon on the RGB (red/green/blue) -fluorescent surface has been considered as one of serious problems to be solved in cathode-ray tube (CRT), which is generally caused by mechanical shock and vibration. In this work, structural design concepts on the major parts of the CRT, such as a frame, a shadow mask, and a spring, are studied to improve the mechanical shockproof character of a CRT by FEM-analyses and experimental approaches ; a frame is newly designed to have strength employing the double-corner-beads which reduces considerably the distortion of the frame and the shadow mask : the edge-bead of a shadow-mask is redesigned to maintain the wide curved surface of a shadow-mask after mechanical shock : finally, a spring supporting the frame and the shadow-mask is designed to have enough flexibility along drop-direction. As an example, a conventional type of a 15inch CRT was utilized to demonstrate the feasibility and usefulness of this work. Overall, some favorable information on the structural design of the CRT is achieved, and the mechanical shockproof character of a 15-inch CRT is improved in the degree of 3G $(1G=9.81m/s^2)$ as an average-value.

Failure Mode Analysis of Mo-tip EFA Cold-Cathode in CRT Spot-knocking Process (CRT의 Spot-knocking 공정에 있어서 몰리브텐 팁 전계 방출 소자 냉응극의 고장 형태 분석)

  • Ju, Byeong-Kwon;Kim, Hoon;Park, Jong-Won;Kim, Nam-Soo;Kim, Dong-Ho;Lee, Yun-Hi
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.414-418
    • /
    • 2001
  • Failure modes of Mo-tip FEA were investigated in detail as a preliminary study for the application of Mo-tip FEA to the CRT electron-gun as a cold cathode. It was identified that the destruction of Mo-tip FEA was originated from reflowing of arc-current during the spot-knocking process followed by secondary arc between gate electrode and cathode substrate. In order to prevent Mo-tip FEA from destruction due to arc-current, two kinds of methods were suggested, that is one is to provide the by-pass of the reflow current and the other is to install a current limiter in the path of gate connection line.

  • PDF

MF(Multi-Function) Cathode for High Current Density CRT

  • Kim, Tae-Wook;Bae, Min-Cheol;Youn, Young-Jun
    • Journal of Information Display
    • /
    • v.5 no.4
    • /
    • pp.23-26
    • /
    • 2004
  • A limitation of oxide cathode is the high current density, caused by low electrical conductivity of an emitter layer. This limitation can be overcome by increasing the conductivity, and uniform dispersion of Ni powder and pore agent could be achieved by using the screen-printing method. This new cathode has shown not only high current density reliability but also improved performance characteristics and as such given the name "Multi-Function cathode". It is expected to be a good replacement of the impregnated cathode.

A Study on the Development of Cathode-Ray Tube Die Using Hot forging (열간단조를 이용한 브라운관 금형의 개발에 관한 연구)

  • 차도진;조종래;배원병;황남철
    • Transactions of Materials Processing
    • /
    • v.9 no.5
    • /
    • pp.533-538
    • /
    • 2000
  • This study has been carried out to develop a CRT die using hot forging. The conventional CRT die made by casting has defects such as void and inclusion. These defects of the cast die make micro-spots on the surface of the CRT which affect the quality of the final product. So, a hot forging process is developed to avoid these defects of CRT die by the model material test and the rigid-plastic FEM. Firstly, model material tests are carried out with plasticine billets in order to investigate the material flow pattern in the die cavity and to get the reasonable initial values for designing the preform in the FE simulation. And then a finite element analysis has been performed to Predict the preform and the forging load of a CRT die. We also suggest an integrated die-set which combines two die-sets into one die-set to save manufacturing time and cost in case of similar die-size.

  • PDF

The Effects of Panel Convexity on Visual Performance and Fatigue in Using Cathode-Ray Tube (CRT) Displays (CRT 디스플레이의 패널곡률이 시각작업 수행도와 안피로도에 미치는 영향)

  • Kim, Sang-Ho;Jang, Seong-Ho;Im, Jong-Ho
    • Journal of the Ergonomics Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.27-44
    • /
    • 2003
  • An experiment was carried out to compare the suitability in visual tasks between flat and conventional (convex) cathode-ray tube (CRT) displays. The subjects performed visual search tasks during 2-h for detecting target words among distracters presented on the screen. The subjects' visual performance was evaluated with average time and number of errors made to complete the tasks. Visual fatigue after the search tasks was also evaluated in terms of degradations in accommodative power and subjective ratings. Difference was not found in task time between the two displays, but flat CRT showed a lower number of errors than conventional CRT. The difference in number of errors was statistically significant at 0=0.05. Although there was no difference between the displays in degradations of accommodative power, results from the subjective ratings showed that flat CRT yields less fatigue than conventional CRT. The results partially support the hypothesis that panel convexity of CRT displays has a significant effect on the performance and fatigue during visual tasks and thus flat CRT is the better display than conventional one.