• Title/Summary/Keyword: CR contraction

Search Result 16, Processing Time 0.025 seconds

GINGIVAL MARGIAL LEAKAGE AND BONDING PATTERN OF THE COMPOSITE RESIN INLAY ACCORDING TO VARIOUS THICKNESS OF DIE SPACER (Die spacer의 두께에 따른 복합레진 inlay의 치은 변연부 미세누출 및 접착양태에 관한 연구)

  • Park, Tae-Il;Shin, Dong-Hoon;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.152-163
    • /
    • 1995
  • This experiment was performed to observe the adhesion pattern and microleakage in the gingival margin according to variation in the resin cement thickness which results from thickness of Die spacer. which is considered to effect the adaptability of the composite resin inlays. Clearfil CR inlays were fabricated on stone models with CR Sep applicated once and Nice fit twice, 4 times, and 6 times each. After 2nd curing within the CRC-100 oven, CR inlays were cemented with CR inlay cement. Dye(2% methylene blue) penetration and adhesion pattern were evaluated after sectioning of gingival margin into :3 pieces. The results were as follows ; 1. The thickness of resin cement showed unevenchanging pattern with that of die spacer, namely, it was increased until 4 times' application of Nice-Fit but was decreased with 6 times' application of that. 2. The degree of dye penetration wasn't affected by cement thickness within a limited value. 3. Most of dye penetration was shown through the interface between cement and enamel rather than the interface between cement and CR inlay. This shows that the affinity of resin cement for CR inlay was superior to the adhesive strength with tooth structure. 4. No gap was found at the interface between enamel and cement but some showed separation between dentin and cement. It is concidered that the contraction force of cement was less than the bond strength with the enamel. 5. Lots of voids were found in the CR inlay and resin cement. There was a pooling tendency of bonding agent and cement in the axiogingival line angle portion. 6. In some specimens, cracks were shown in enamel margin. From this it could be considered that cavity preparation and surface treatment weakened the tooth structure.

  • PDF

Vasodilation of Ethanol Extract of Cinnamomi Ramulus via Voltage Dependent $Ca^{2+}$ Channel Blockage (전압의존성 $Ca^{2+}$ 통로 억제를 통한 계지(桂枝) 에탄올 추출물의 혈관이완 효능)

  • Kim, Jong-Bong;Shin, Heung-Mook
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.4
    • /
    • pp.592-597
    • /
    • 2010
  • Cinnamomi Ramulus is one of the medicinal plants that have been used to improve various diseases caused by insufficient blood circulation. This study was performed for the investigation of vasodilation efficacy ethanol extract of Cinnamomi Ramulus (CR). CR exhibited vascular relaxation against phenylephrine (PE, $10^{-6}M$)-, KCl- and NaF-induced contraction in rat thoracic aorta. In addition, its relaxation was endothelium-independent. Treatment of potassium channel blockers such as gilbenclamide (Gli, $10^{-5}M$), tetraethylammonium (TEA, 1 mM) and 4-aminopyridine (4-AP, 0.2 mM) did not effect on the relaxation of CR. The relaxant effects were also not inhibited by pre-treatment of rat aorta with L-NAME ($10^{-4}M$), methylene blue ($10^{-5}M$), indomethacin ($10^{-5}M$), and atropine ($10^{-6}M$). However, nifedipine ($10^{-5}M$), L-type $Ca^{2+}$ channel blocker, in part attenuated the relaxation of CR ($0.2\;mg/m{\ell}$), but SK&F96365 ($3{\times}10^{-5}M$), receptor activated $Ca^{2+}$ channel blocker and 2-APB ($10^{-4}M$), store operated $Ca^{2+}$ channel blocker did not affact dilation of CR. These findings suggest that the endothelium-independent relaxation effect of CR is partly related with inhibition of $Ca^{2+}$ influx via voltage dependent $Ca^{2+}$ channel.

Effects of Proprioceptive Neuromuscular Facilitation Relaxation Techniques on Hamstring Flexibility and Vertical Jump Performance (고유수용성신경근촉진법 이완기법이 뒤넙다리근 유연성과 점프수행력에 미치는 영향)

  • Lim, Jae-Heon;Lee, Min-Kook;Park, Jong-Hyuk;Jung, Tae-Ho;Jo, Eun-Bi
    • PNF and Movement
    • /
    • v.13 no.3
    • /
    • pp.135-143
    • /
    • 2015
  • Purpose: The purpose of this study was to assess the effect of the proprioceptive neuromuscular facilitation (PNF) relaxation technique (hold relax; HR, contract relax; CR) and static stretch (SS) on hamstring flexibility and vertical jump performance in healthy adults over a four-week period. Methods: Twenty-four healthy adults volunteered to participate in PNF and static stretch sessions. The subjects were divided into three groups as follows: 8 subjects in the SS group, 8 subjects in the HR group, and 8 subjects in the CR group. In the HR and CR groups, contractions lasted 15 seconds per trial and consisted of 5 sets of 15 seconds of hamstring contraction immediately followed by 15 seconds of passive static hamstring stretching. For the static group, the participants were asked to stretch by hanging a leg over a table for 30 seconds. Subjects in all groups performed the exercises three days per week for 4 weeks. The active straight leg raising (ASLR) test, active knee extension (AKE) test, and vertical jump test were performed before the intervention and after 1, 2, and 4 weeks. Results: The SS, HR, and CR techniques effected positive improvement in hamstring flexibility and vertical jump performances but neither of the stretching methods had any statistically significant different effects according to group, although there were interactions (between group and time) in the ALSR group from 1 week to 2 week and in the AKE test from pretest to 1 week. Conclusion: Based on the results of the current study, SS, HR, and CR were shown to affect hamstring flexibility and vertical jump performance in healthy adults. In particular, it was determined that within a short period, hamstring flexibility could be attributed more to CR than to SS.

Control Algorithm of the Lower-limb Powered Exoskeleton Robot using an Intention of the Human Motion from Muscle (인체근육의 동작의도를 이용한 하지 근력증강형 외골격 로봇의 제어 알고리즘)

  • Lee, Hee-Don;Kim, Wan-Soo;Lim, Dong-Hwan;Han, Chang-Soo
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.2
    • /
    • pp.124-131
    • /
    • 2017
  • This paper present a novel approach to control the lower body power assistive exoskeleton system of a HEXAR-CR35 aimed at improving a muscular strength. More specifically the control of based on the human intention is crucial of importance to ensure intuitive and dexterous motion with the human. In this contribution, we proposed the detection algorithm of the human intention using the MCRS which are developed to measure the contraction of the muscle with variation of the circumference. The proposed algorithm provides a joint motion of exoskeleton corresponding the relate muscles. The main advantages of the algorithm are its simplicity, computational efficiency to control one joint of the HEXAR-CR35 which are consisted knee-active type exoskeleton (the other joints are consisted with the passive or quasi-passive joints that can be arranged by analyzing of the human joint functions). As a consequence, the motion of exoskeleton is generated according to the gait phase: swing and stance phase which are determined by the foot insole sensors. The experimental evaluation of the proposed algorithm is achieved in walking with the exoskeleton while carrying the external mass in the back side.

Literature review of PNF application for improvement of fitness in the elderly (노인의 기초 체력 향상을 위한 PNF 기법 적용)

  • Han, Jin-Tae;Bae, Sung-soo
    • PNF and Movement
    • /
    • v.6 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • Purpose : The purpose of this study is to review of effect of the PNF application for improvement of the basic physical fitness in the elderly. Methods : By using internet, we research the PubMed, Science Direct, KISS, DBpia and the article on the effect of PNF. We selected the article between 1970 and 2007. Key words were PNF, Exercise, Elderly. Results : PNF refers to any of several post-isometric relaxation stretching techniques in which a muscle group is passively stretched, then contracts isometrically against resistance while in the stretched position, and then is passively stretched again through the resulting increased range of motion. Most PNF techniques employ isometric agonist contraction/relaxation where the stretched muscles are contracted isometrically and then relaxed. The most common PNF techniques are CR, HR, CRAC, HR-AC, AC. PNF exercise effected on the muscular strength and flexibility and balance and ROM in the elderly. Conclusion : PNF is a safety and effective exercise to improve the muscular strength and flexibility and balance and ROM in the elderly. Therefore, we suggest that PNF need to generalize for the elderly.

  • PDF

The Accuracy of Subjective Rating of Grip Strength Associated with Target Force Levels (Target Force Level에 따른 악력의 주관적 평가 정확도)

  • Kong, Yong-Ku;Park, Donghyun;Choi, Kyeong-Hee;Shin, Jae-Min;Lee, Juhee;Lee, Jun-Hyub
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.569-578
    • /
    • 2017
  • Objective: The purposes of this experiment are an analysis of accuracy between target force level and subjective rating for the Target Force Level and an analysis of the patterns of subjective rating depending on target force level when there is no feedback from males for analysis. Background: The study of perceived exertion about the static contraction is processed with using among the matching procedure method between contralateral limbs, Exertion vs. Borg CR-10 scale and Exertion vs. %MVC (Maximum Voluntary Contraction). However, when there is no feedback, there is lack of the study on whether the subject can distinguish the subjective rating of the force depending on the target force levels. Method: Total 30 males, healthy subjects are measured the maximum grip strength, MVC, and then, each subject is measured the subjective rating and the accuracy with the random target force level (10, 20, 30, 40, 50, 60, 70, 80, and 90% MVC). Results: In the MVC study, males exerted 256.87N (${\pm}51.33$). In the subjective rating of grip strength increased for each Target Force Level (9 levels), higher subjective rating evaluated (p<0.05). In accuracy examination between target force level and subjective rating of grip strength by each %MVC, 10, 30, 40, 50, 70, 90% target force levels showed accurate strength (p>0.05). However, at 20% target force level, the subjects evaluated less subjective rating of grip strength than the target force (Underestimation), and at 60% and 80% target force level, the subjects evaluated more subjective rating of grip strength than the target force (Overestimation) (p<0.05). Conclusion: In the experiment, the MVC showed 256.87N (${\pm}51.33$) for the male adults and as the subjective rating value increased for each Target Force Level (9 levels), higher subjective rating evaluated (p<0.05). Moreover, the results of the accuracy test between target forces and subjective rating of the subjects showed that most participants rated a fairly accurate assessment of subjective rating of grip strength for Target Force Level (9 levels), except for 20%, 60%, and 80%MVC. Application: This experimental result would be used for basic data for the subjective rating of grip strength pattern by the target force level when the voluntary muscle is contracted.