• Title/Summary/Keyword: CPS transition

Search Result 16, Processing Time 0.021 seconds

A Study on the V-band Waveguide-to-CPW Transitions (V-band 도파관-CPW 변환 구조에 대한 연구)

  • Kim Dong-Ki;Jeong Jin-Ho;Kwon Young-Woo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.5 s.96
    • /
    • pp.488-493
    • /
    • 2005
  • In this study, waveguide-to-CPW transitions were developed for integrating waveguide and MMIC at V-band. The finite element method for numerical analysis and repeated experiments were performed to propose two types of waveguide-to-CPW transition. Using quartz substrate, proposed structures were designed for low loss as well as broadband characteristics. These waveguide-to-CPW transitions showed a good reliability and insensitivity to matching precision, and they could be fabricated with lower cost than that of the conventional connectors. Proposed two types of the structure showed insertion loss less than 1.9 dB and return loss better than 14 dB from 53 GHz to 60 GHz except unwanted resonance region, respectively.

Study on the Security R&R of OT-IT for Control System Network Boundaries (제어 네트워크 경계에 대한 OT-IT 책임 역할 연구)

  • WOO, Young Han;Kwon, Hun Yeong
    • Journal of Information Technology Services
    • /
    • v.19 no.5
    • /
    • pp.33-47
    • /
    • 2020
  • In recent years, due to the demand for operating efficiency and cost reduction of industrial facilities, remote access via the Internet is expanding. the control network accelerates from network separation to network connection due to the development of IIoT (Industrial Internet of Things) technology. Transition of control network is a new opportunity, but concerns about cybersecurity are also growing. Therefore, manufacturers must reflect security compliance and standards in consideration of the Internet connection environment, and enterprises must newly recognize the connection area of the control network as a security management target. In this study, the core target of the control system security threat is defined as the network boundary, and issues regarding the security architecture configuration for the boundary and the role & responsibility of the working organization are covered. Enterprises do not integrate the design organization with the operation organization after go-live, and are not consistently reflecting security considerations from design to operation. At this point, the expansion of the control network is a big transition that calls for the establishment of a responsible organization and reinforcement of the role of the network boundary area where there is a concern about lack of management. Thus, through the organization of the facility network and the analysis of the roles between each organization, an static perspective and difference in perception were derived. In addition, standards and guidelines required for reinforcing network boundary security were studied to address essential operational standards that required the Internet connection of the control network. This study will help establish a network boundary management system that should be considered at the enterprise level in the future.

Design of a Diode Detector Using Ultra-Wideband Transitions (초광대역 전이 구조를 이용한 다이오드 검파기 설계)

  • Kim, In-Bok;Kim, Young-Gon;Kim, Tae-Gyu;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.8
    • /
    • pp.814-819
    • /
    • 2008
  • In this paper, a design of broadband detectors utilizing two ultra-wideband transitions is described for the first time, and the implementation method and measurement results of the detectors are provided. Two ultra-wideband transitions are used for input/output matching circuits for the diode detectors. Two detectors have been implemented using general Schottky diodes and zero-bias Schottky diodes. With general Schottky diodes, the fabricated detector provides less than 10 dB return loss from 11 GHz to 20 GHz, and the detector sensitivity is 30 mV/mW. The detector with zero-bias Schottky diodes shows significantly higher detection sensitivity(300 mV/mW).

Synthesis of flame retardant acrylic emulsion pressure sensitive adhesives by co-polymerization with phosphoric flame retardant monomer (인계 난연 단량체와의 공중합을 통한 난연성 수성 아크릴 에멀젼 점착제 제조)

  • Jeon, Min Seok;Jung, Ji Hun;Kim, Gu Ni
    • Journal of Adhesion and Interface
    • /
    • v.20 no.4
    • /
    • pp.135-139
    • /
    • 2019
  • In this work, flame retardant acrylic emulsion pressure sensitive adhesives were newly polymerized combining phosphorous flame retardant monomer and acrylic monomer like butyl acrylate, 2-ethylhexyl acrylate, methyl methacrylate, acrylic acid, and 2-hydroxyethyl methacrylate. The process of polymerization showed 100% of conversion at solid content of 65%, and viscosity of acrylic emulsion was increased up to 5500 cps when phosphorous flame retardant monomer was added into acrylic emulsion. The structure of flame retardant acrylic emulsion was identified using FT-IR and thermal properties like glass transition temperature (Tg) were checked by differential scanning calorimeter (DSC). Acrylic emulsion without phosphorous flame retardant monomer had Tg of -44.1℃ and peel strength of 2,100gf/inch, however, flame retardant acrylic emulsion showed maximum Tg (-31.4℃) and peel strength of 200gf/inch when 15 part of phosphorous flame retardant monomer was added. Flammability test was also conducted to confirm the application of flame retardant acrylic emulsion as the flame retardant addtive.

A Case Study on Smart Factory Extensibility for Small and Medium Enterprises (중소기업 스마트 공장 확장성 사례연구)

  • Kim, Sung-Min;Ahn, Jaekyoung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.44 no.2
    • /
    • pp.43-57
    • /
    • 2021
  • Smart factories can be defined as intelligent factories that produce products through IoT-based data. In order to build and operate a smart factory, various new technologies such as CPS, IoT, Big Data, and AI are to be introduced and utilized, while the implementation of a MES system that accurately and quickly collects equipment data and production performance is as important as those new technologies. First of all, it is very essential to build a smart factory appropriate to the current status of the company. In this study, what are the essential prerequisite factors for successfully implementing a smart factory was investigated. A case study has been carried out to illustrate the effect of implementing ERP and MES, and to examine the extensibilities into a smart factory. ERP and MES as an integrated manufacturing information system do not imply a smart factory, however, it has been confirmed that ERP and MES are necessary conditions among many factors for developing into a smart factory. Therefore, the stepwise implementation of intelligent MES through the expansion of MES function was suggested. An intelligent MES that is capable of making various decisions has been investigated as a prototyping system by applying data mining techniques and big data analysis. In the end, in order for small and medium enterprises to implement a low-cost, high-efficiency smart factory, the level and goal of the smart factory must be clearly defined, and the transition to ERP and MES-based intelligent factories could be a potential alternative.

Effect of Drying Methods on Physicochemical Properties of Agar (건조 방법이 한천의 물리${\cdot}$화학적 특성에 미치는 영향)

  • KIM Oc-Do;KIM Yuck-Yong;LEE Nahm-Gull;CHO Young-Je;LEE Kang-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.5
    • /
    • pp.681-688
    • /
    • 1996
  • To investigate the effort of drying methods on the physicochemical properties of agar, gel strength, viscosity, melting and setting point, and phase transition by differential scanning calorimetery (DSC) during its heating were determined. In addition the structural differences of agar powder by scanning electron microscope (SEM) was examined. The most shortest onset temperature of gel strength increase was extruding method among any other methods. Viscosity of agar with hot air method, 400.00 cps at $45^{\circ}C$, was markedly increased, but with spraying and extruding ones were little change. The melting and setting point, and the temperature for maximum endothermic and enthalpy for agar with extruding one, $80.01^{\circ}C,\;36.05^{\circ}C\;and\;61.72^{\circ}C,\;0.73\;cal/g$, respectively, were lowest among the drying ones. But in the case of reheating after gelling, there were little change in all methods. Observing the surface structure of agar with SEM, extruding method showed the most unstable with absorptive property.

  • PDF