• 제목/요약/키워드: CP-titanium

검색결과 113건 처리시간 0.026초

Estimating Apparent Nutrient Digestibility of Diets Containing Leucaena leucocephala or Moringa oleifera Leaf Meals for Growing Rabbits by Two Methods

  • Safwat, A.M.;Sarmiento-Franco, L.;Santos-Ricalde, R.H.;Nieves, D.;Sandoval-Castro, C.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제28권8호
    • /
    • pp.1155-1162
    • /
    • 2015
  • This study aimed to evaluate the nutrient digestibility of growing rabbits fed diets with different levels of either Leucaena leucocephala (LLM) or Moringa oleifera (MOLM) leaf meals and also to compare total collection and $TiO_2$ marker methods for estimating digestibility. A total of 30 California growing rabbits ($1.81{\pm}0.19kg$ live weight on average) were randomly distributed into five experimental groups of six rabbits each and were housed in individual cages. The groups were control, 30% LLM, 40% LLM, 30% MOLM, and 40% MOLM. All groups received pelleted diets for two weeks; diets also contained 4 g/kg titanium dioxide as dietary marker. Daily feed intake was recorded during the whole experimental period and total feces were collected daily and weighed individually during four days. The results showed that there were no difference (p>0.05) in feed, dry matter (DM), organic matter (OM), crude protein (CP), digestible energy, and crude fiber (CF) intake between the control group and the other experimental groups. The apparent digestibility values of DM, OM, CP, CF, acid detergent fiber, and gross energy were the highest for control group (p = 0.001), meanwhile MOLM diets had generally higher nutrient digestibility coefficients than LLM diets. Increasing the inclusion level of leaf meal in the diet from 30% to 40% improved the digestibility of CF from 45.02% to 51.69% for LLM and from 48.11% to 55.89% for MOLM. Similar results for apparent nutrient digestibility coefficients were obtained when either total collection or indigestible marker method was used. In conclusion, the digestibility of MOLM containing diets were better than LLM diets, furthermore $TiO_2$ as an external marker could be used as a simple, practical and reliable method to estimate nutrients digestibility in rabbit diets.

순 타이타늄의 GTAW 용접성 및 기계적 특성 (The weldability and mechanical property of CP titanium by GTAW)

  • 홍재근;김지훈;이채훈;염종택;강정윤
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.57-57
    • /
    • 2009
  • 산업의 고도화에 따른 구조물의 사용 환경이 열악해지고 최근 에너지저감과 환경문제 개선을 위한 경화의 요구에 따라 뛰어난 내식성 및 우수한 고비강도 특성을 갖고 있는 타이타늄 및 타이타늄합금의 활용에 대한 연구가 많은 주목을 받고 있다. 이에 따라 타이타늄 신합금의 개발뿐만 아니라 기존에 개발되어 비교적 보편적으로 적용되고 있는 타이타늄 부품의 제조 및 성형기술에 대한 수요도 급증하고 있다. 특히, 기기 및 부품 제조를 위한 용접/접합기술도 매우 중요한 요소기술로 자리메김하고 있다. 타이타늄은 산소, 수소 등의 침입형 원소와의 친화력이 강한 활성이 큰 금속으로 용접시 고온에 노출되면 급격히 산화 및 취화 등의 문제를 발생한다. 따라서 타이타늄의 용접시에는 $426^{\circ}C$이상의 온도에서는 대기로부터 용접부가 차단되도록 하는 쉴딩기술이 매우 중요하다. 타이타늄의 용접은 일반적으로 아크용접, 전자빔 용접, 레이저 용접 및 확산접합 등이 적용되고 있으나 용접입열 조정이 용이하고 아크 안정성이 높고 용접부의 기계적 특성이 우수한 GTA 용접이 작업성을 고려하여 가장 많이 적용되고 있다. 본 연구에서는 미국용접학회(AWS)의 타이타늄 용접가이드를 분석 및 소개하였고, 1t 이하의 박판 CP Ti를 대상으로 GTAW 용접부 미세조직 및 기계적 특성을 분석하였다. 이때, 용접 비드폭 제어 및 펄스 용접기술을 통하여 박판 타이타늄의 최적 GTAW 공정변수 제어기술을 분석하였다.

  • PDF

Shear bond strength of composite resin to titanium according to various surface treatments

  • Lee, Seung-Yun;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권2호
    • /
    • pp.68-74
    • /
    • 2009
  • STATEMENT OF PROBLEM. When veneering composite resin-metal restoration is prepared, the fact that bond strength between Ti and composite resin is relatively weak should be considered. PURPOSE. The purpose of this study is to evaluate the shear bond strength between the veneering composite resin and commercial pure (CP) Ti / Ti-6Al-4V alloy according to the method of surface treatment. MATERIAL AND METHODS. The disks were cast by two types of metal. Their surfaces were treated by sandblasting, metal conditioner, TiN coating and silicoating respectively. After surface treatment, the disks were veneered by composite resin (Tescera$^{TM}$, Bisco, USA) which is 5 mm in diameter and 3 mm in thickness. The specimens were stored in water at $25^{\circ}C$ for 24 hours, and then evaluated for their shear bond strength by universal testing machine (STM-$5^{(R)}$, United Calibration, USA). These values were statistically analyzed. RESULTS. 1. All methods of surface treatment were used in this study satisfied the requirements of ISO 10477 which is the standard of polymer-based crown and bridge materials. 2. The metal conditioner treated group showed the highest value in shear bond strength of CP Ti, silicoated group, TiN coated group, sandblasted group, in following order. 3. The silicoated group showed the highest value in shear bond strength of Ti-6Al-4V alloy, metal conditioner treated group, sandblasted group, TiN coated group, in following order. CONCLUSION. Within the limitations of this study, all methods of surface treatment used in this study are clinically available.

생체용 Ti합금의 산화거동에 미치는 Ta 및 Nb 첨가의 영향 (Effect of Alloy Addition (Ta, Nb) on Oxidation Behavior of cp-Ti for Biomaterials)

  • 이도재;오태욱;박범수;김수학;전충극;윤계림
    • 한국재료학회지
    • /
    • 제14권3호
    • /
    • pp.211-217
    • /
    • 2004
  • The oxidation behaviors of Ti-10Ta-10Nb alloy and Ti-6Al-4V alloy were studied in dry air atmosphere. Specimens were melted in consumable vacuum arc furnace and homogenized at $1050^{\circ}C$ for 24 h. Hot rolling was performed at $1000^{\circ}C$. Specimens of the alloys were oxidized as the temperature range $400~650^{\circ}C$ for 30 min. The oxidation behavior of the alloys was analysed by optical microscope, SEM/EDX, XRD, XPS and TGA. Immersion test was performed in 1% Lactic acid. In the microscope observation, oxide layer of Ti-10Ta-10Nb alloy was denser and thinner than Ti-6Al-4V's. The weight gains during the oxidation rapidly increased at the temperature above $600^{\circ}C$ in Ti-6Al-4V's alloy and$ 700^{\circ}C$ in Ti-10Ta-10Nb alloy. According to XRD results, oxide layers were composed of mostly $TiO_2$(rutile) phase. It was analysed that the passive film of the Ti alloys consisted of $TiO_2$ through X-ray photoelectron spectroscopy(XPS) analysis.

기계적 합금화법과 열처리를 통한 Ni이 도핑 된 광촉매 $TiO_2$ 나노 복합상 제조 (Synthesis or photocatalytic Ni-doped nanocomposite $TiO_2$ by mechanical alloying and heat treatment)

  • 박하성;김동현;조재한;김선재;이경섭
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.667-672
    • /
    • 2005
  • In order to effectively utilize visible light in the photocatalytic reaction, nanaocomposite of Ni doped $TiO_2$ and $NiTiO_3$ powders were synthesized by mechanical alloying and heat treatment. About 5.4 wt% of $NiTiO_3$ with particle size less than 15nm was uniformly formed in the Ni-doped rutile $TiO_2$ matrix. The UV/VIS-DRS and PL investigation showed that the nanocompasite $TiO_2$ powders had a longer absorpt ion wavelength (600$\sim$650nm, 2.0$\sim$1.9eV) than that of Ni-doped $TiO_2$ or rutile $TiO_2$ powder. The carbon decomposition of 4-CP by the nanocompasite $TiO_2$ powders were higher than other $TiO_2$ (P-25).

  • PDF

초미세 금속 박판 홀 어레이 가공 (Fabrication of Ultra Small Size Hole Array on Thin Metal Foil)

  • 임성한;손영기;오수익
    • 소성∙가공
    • /
    • 제15권1호
    • /
    • pp.9-14
    • /
    • 2006
  • In the present research, the simultaneous punching of ultra small size hole of $2\~10\;{\mu}m$ in diameter on flat rolled thin metal foils was conducted with elastic polymer punch. Workpiece used in the present investigation were the rolled pure copper of $3{\mu}m$ in thickness and CP titanium of 1.5fm in thickness. The metal foils were punched with the dies and arrays of circular and rectangular holes were made. The process set-up is similar to that of the flexible rubber pad farming or Guerin process. Arrays of holes were punched successfully in one step forming. The punched holes were examined in terms of their dimensions. The effects of the wafer die hole dimension and heat treatment of the workpiece on ultra small size hole formation of the thin foil were discussed. The process condition such as proper die shape, pressure, pressure rate and diameter-thickness ratio (d/t) were also discussed. The results in this paper show that the present method can be successfully applied to the fabrication of ultra small size hole away in a one step operation.

치과주조용 Ti-X%Cu(X=2,5,10)합금의 미세조직 및 경도 (Microstructure and Hardness of Ti-X%Cu(X=2,5,10) Alloys for Dental Castings)

  • 정종현
    • 대한치과기공학회지
    • /
    • 제31권3호
    • /
    • pp.9-14
    • /
    • 2009
  • This study evaluated the mechanical properties of Ti-Cu alloys with the hope of developing an alloy for dental casting with better mechanical properties than unalloyed titanium. Ti-Cu alloys with four concentrations of Cu(2,5,10wt%) were made in an argon-arc melting furnace. The microstructure and micro-Vickers hardness were determined. X-ray diffraction pattern test was performed on the polished specimens. The microstructure of 2%Cu and 5%Cu alloys are shown acicular ${\alpha}Ti$ phase formed on the surfaces of previously formed $\beta$grains. The 10%Cu alloys has essentially a eutectoid structure; this structure includes lamella of ${\alpha}Ti$ and $Ti_2Cu$ phase that transformed from ${\alpha}Ti$ at the eutectoid temperature. The micro-Vickers hardness of CP Ti specimens was significantly(p<0.05) lower than that of any of the other alloys. Among the Ti-Cu alloys, the 10%Cu alloys exhibited a significantly(p<0.05) higher hardness value. but lower than that of Ti-6%Al-4%V alloy. From these results, it was concluded that new alloys for dental castings should be designed as Ti-Cu based alloys if other properties necessary for dental castings were obtained.

  • PDF

Electrochemical Behaviors of PEO-treated Ti-6Al-4V Alloy in Solution Containing Zn and Si Ions

  • Hwang, In-Jo;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.160-160
    • /
    • 2017
  • Commercially pure titanium (Cp-Ti) and Ti alloys (typically Ti-6Al-4V) display excellent corrosion resistance and biocompatibility. Although the chemical composition and topography are considered important, the mechanical properties of the material and the loading conditions in the host have, conventionally. Ti and its alloys are not bioactive. Therefore, they do not chemically bond to the bone, whereas they physically bond with bone tissue. The electrochemical deposition process provides an effective surface for biocompatibility because large surface area can be served to cell proliferation. Plasma electrolyte oxidation (PEO) enables control in the chemical composition, porous structure, and thickness of the TiO2 layer on Ti surface. Silicon (Si) in particular has been found to be essential for normal bone and cartilage growth and development. Zinc (Zn) plays very important roles in bone formation and immune system regulation, and is also the most abundant trace element in bone. The objective of this work was to study on electrochemical behaviors of PEO-treated Ti-6Al-4V Alloy in solution containing Zn and Si ions. The morphology, the chemical composition, and the microstructure analysis of the sample were examined using FE-SEM, EDS, and XRD. The potentiodynamic polarization and AC impedance tests for corrosion behaviors were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat. The promising results successfully demonstrated the immense potential of Si/Zn-TiO2 coatings in dental and biomaterials applications.

  • PDF

금속기질에 앓은 마이크로 다공질 스케폴드 코팅에 관한 연구 (Thin Micro-Porous Scaffold Layer on Metallic Substrate)

  • 신동춘;자이젱 미아오;김원철
    • 동력기계공학회지
    • /
    • 제14권5호
    • /
    • pp.41-47
    • /
    • 2010
  • 티타늄과 티타늄 합금은 재료적 특이성 때문에 심장 혈관 임플란트에서 일반적으로 사용되어 왔다. 일찍이 적용된 예로는 인공심장판막, 심박조율기의 보호케이스, 혈액 순환 장치 등이 있다. 하지만 물질유도혈전증(Material-induced thrombosis)은 혈전폐색에 의해 기인한 기능 손실로 심장혈관 임플란트 장치의 주된 합병증으로 존재하고 있으며, 심장혈관 임플란트의 혈전유전자는 심장혈관장치의 발달에 주된 난관 중 하나로 남아있다. 그리고 텍스처 혈액 접합 물질(Textured blood-contacting material)은 1960년대 초반 이후부터 혈액순환 보조 장치의 임상실험에 사용되고 있다. 접합 물질에 내장된 텍스처 섬유조직 표면은 형성, 성장, 안정적 부착, 생물학적 내벽(neointimal layer) 등 유도 혈액(entrapping blood) 성분에 의해 형성된다. 공동(cavity) 형상의 용해 가능한 미립자를 사용하는 SCPL법(Solvent casting/particulate leaching method)은 티타늄 기질 이전에 형성된 폴리우레탄 위에 텍스처(texture)를 생성하기 위해 사용되었다. 또한 콜라겐의 부동화(不動化)에 의한 공동(cavity)은 혈액 접합면에 잔존하기 위한 내피세포를 고정할 수 있는 효과가 있다. cpTi로 층화된 PU 기소공성(microporous)은 구조적 특성과 혈전증 감소를 위한 생물학적 내벽 사용의 잠재성을 평가하기 위한 세포 공동체 실험을 통해서 평가되었다.

미세 홀 어레이 펀칭 가공 (Punching of Micro-Hole Array)

  • 손영기;오수익;임성한
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 금형가공,미세가공,플라스틱가공 공동 심포지엄
    • /
    • pp.193-197
    • /
    • 2005
  • This paper presents a method by which multiple holes of ultra small size can be punched simultaneously. Silicon wafers were used to fabricate punching die. Workpiece used in the present investigation were the rolled pure copper of $3{\mu}m$ in thickness and CP titanium of $1.5{\mu}m$ in thickness. The metal foils were punched with the dies and arrays of circular and rectangular holes were made. The diameter of holes ranges from $2-10{\mu}m$. The process set-up is similar to that of the flexible rubber pad forming or Guerin process. Arrays of holes were punched successfully in one step forming. The punched holes were examined in terms of their dimensions, surface qualities, and potential defect. The effects of the die hole dimension on ultra small size hole formation of the thin foil were discussed. The optimum process condition such as proper die shape and diameter-thickness ratio (d/t) were also discussed. The results in this paper show that the present method can be successfully applied to the fabrication of ultra small size hole array in a one step operation.

  • PDF