• Title/Summary/Keyword: CP motion

Search Result 47, Processing Time 0.019 seconds

Torticollis and Atlantoaxial Rotatory Subluxation after Chiropractic Therapy (카이로프랙틱 후 발생한 환축추 아탈구 및 후천성 사경)

  • Kim, Doyoung;Yun, Wang Hyeon;Park, Jinyoung;Park, Jung Hyun
    • Clinical Pain
    • /
    • v.18 no.2
    • /
    • pp.92-96
    • /
    • 2019
  • Torticollis is an abnormal, asymmetric head or neck position which usually caused by imbalance of paracervical muscles. The traumatic torticollis can be caused by following events; atlantoaxial rotatory subluxation, atlantoaxial dislocation, cervical vertebral fractures, and injury to the cervical musculature. Especially, acute traumatic atlantoaxial rotatory subluxation usually presents limitation of cervical range of motion without pain or neurologic deficit. We report a case of a 58 year-old man who developed the acute atlantoaxial rotatory subluxation right after the chiropractic therapy, which induced the limitation of cervical range of motion to 52.5% of normal range. The magnetic resonance image revealed the facture of the odontoid process and the partial injury in transverse ligaments of the atlas. He underwent intramuscular botulinum toxin injection and 10 days of continuous cervical traction 15 hours a day using a 5 kg weight. The range of the cervical motion restored up to 90.2% of normal range.

Molecular Dynamics in Paraelectric Phase of KH2PO4 Crystals Studied by Single Crystal NMR and MAS NMR

  • Paik, Younkee;Chang, Celesta L.
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.17 no.1
    • /
    • pp.19-23
    • /
    • 2013
  • The temperature dependences of the NMR spectrum and the spin-lattice relaxation times in $KH_2PO_4$ were investigated via single-crystal NMR and MAS NMR. The stretched-exponential relaxation that occurred because of the distribution of correlation times was indicative of the degree of the distribution of the double-well potential on the hydrogen bond. The behaviors responsible for the strong temperature dependences of the $^1H$ and $^{31}P$ spin-lattice relaxation times in the rotating frame $T_{1{\rho}}$ in $KH_2PO_4$ are likely related to the reorientational motion of the hydrogen-bond geometry and the $PO_4$ tetrahedral distortion.

Performance based evaluation of RC coupled shear wall system with steel coupling beam

  • Bengar, Habib Akbarzadeh;Aski, Roja Mohammadalipour
    • Steel and Composite Structures
    • /
    • v.20 no.2
    • /
    • pp.337-355
    • /
    • 2016
  • Steel coupling beam in reinforced concrete (RC) coupled shear wall system is a proper substitute for deep concrete coupling beam. Previous studies have shown that RC coupled walls with steel or concrete coupling beam designed with strength-based design approach, may not guarantee a ductile behavior of a coupled shear wall system. Therefore, seismic performance evaluation of RC coupled shear wall with steel or concrete coupling beam designed based on a strength-based design approach is essential. In this paper first, buildings with 7, 14 and 21 stories containing RC coupled shear wall system with concrete and steel coupling beams were designed with strength-based design approach, then performance level of these buildings were evaluated under two spectrum; Design Basis Earthquake (DBE) and Maximum Considered Earthquake (MCE). The performance level of LS and CP of all buildings were satisfied under DBE and MCE respectively. In spite of the steel coupling beam, concrete coupling beam in RC coupled shear wall acts like a fuse under strong ground motion.

Multi-Object Detection and Tracking Using Dual-Layer Particle Sampling (이중계층구조 파티클 샘플링을 사용한 다중객체 검출 및 추적)

  • Jeong, Kyungwon;Kim, Nahyun;Lee, Seoungwon;Paik, Joonki
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.9
    • /
    • pp.139-147
    • /
    • 2014
  • In this paper, we present a novel method for simultaneous detection and tracking of multiple objects using dual-layer particle filtering. The proposed dual-layer particle sampling (DLPS) algorithm consists of parent-particles (PP) in the first layer for detecting multiple objects and child-particles (CP) in the second layer for tracking objects. In the first layer, PPs detect persons using a classifier trained by the intersection kernel support vector machine (IKSVM) at each particle under a randomly selected scale. If a certain PP detects a person, it generates CPs, and makes an object model in the detected object region for tracking the detected object. While PPs that have detected objects generate CPs for tracking, the rest of PPs still move for detecting objects. Experimental results show that the proposed method can automatically detect and track multiple objects, and efficiently reduce the processing time using the sampled particles based on motion distribution in video sequences.

Effects of 3D Compression Pants and Kinesio Taping on Isokinetic Muscular Function of Leg During Knee Joint Flexion Motion (3D 밀착형 팬츠와 키네시오 테이핑이 무릎관절의 등속성 굴곡 운동 시 하지의 근기능에 미치는 영향)

  • Choi, Jiyoung;Park, Heegeun;Lee, Wanglok;Hong, Kyunghi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.2
    • /
    • pp.240-257
    • /
    • 2016
  • This study determines the effect of 3D compression pants and Kinesio taping on muscular function of the leg during knee joint flexion and extension. Eight males participated in the experiment, wearing basic pants (BP), Kinesio taping on bare skin (KT), 3D compression pants with (KTP) and without Kinesio taping (CP). The test protocol for isokinetic muscular function was composed of four sets at three angular velocities (60, 180, $240^{\circ}/sec$) using Cybex 660. Peak torque and work per repetition of the lower limbs of eight males were analyzed from the result of Cybex. Agility and power of the subjects were examined from side step and sergeant jump. Peak torque, average power, work per repetition, force decay time of subjects wearing CP and KTP were significantly better than BP or KT, especially at low angular velocity of $60^{\circ}/sec$. The time to generate peak torque of subjects wearing BP was the longest, while the force-decay time of BP was the shortest. The application of Kinesio tape on skin did not increase muscle peak torque, work and power, but did shorten the time to generate peak torque.

A Study on the Quantitative Characteristics of Needle Force on the Acupuncture Practical Model (침자 술기 실습 모델에서 침감의 정량적 특성에 관한 연구)

  • Lee, Yeon Sun;Kim, Seon Hye;Kim, Eun Jung;Lee, Seung Deok;Kim, Kyung Ho;Kim, Kap Sung;Jung, Chan Yung
    • Korean Journal of Acupuncture
    • /
    • v.35 no.3
    • /
    • pp.149-158
    • /
    • 2018
  • Objectives : In this study, we quantitatively evaluated the needle forces using needle insertion-measurement system and compared the needle sensation of each acupuncture practical model. Methods : After inserting acupuncture with a sensor to six models, a lifting-thrusting motion was implemented using the needle insertion-measurement system. The needle force was measured repeatedly, and the measurement was analyzed based on the modified Karnopp friction model for a comparison of friction coefficients. After the insertion, practitioners did lifting-thrusting manipulations. They quantified the similarity of needle sensation with VAS (Visual Analogue Scale). Results : When friction force and coefficients of friction in five different models were compared with a porcine shank model, all five models were significantly different from a porcine shank model, cotton and apple showing the closest frictional values to that of a porcine shank model. In the Cp and Cn values of cotton and in the Cp values of IM injection pad, there was no statistically significant difference. The similarity of the needle sensation between the porcine shank and five models was the highest in the apple, and overlapping papers was the lowest. Conclusions : This study quantitatively compared the physical forces in the practical model when implementing lifting-thrusting manipulations, using a needle insertion-measurement system. We suggest that a reproducible exercise model that reflects the characteristics of various human tissues, such as viscoelasticity or strength, needs to be further developed. This will contribute to establishing standardized acupuncture practice training.

Effects of Cervical Instability on Function of Deep Neck Flexor Muscle and Muscle Tonus of Neck Muscles (목 불안정성이 깊은목굽힘근의 기능과 목 근육들의 긴장도에 미치는 영향)

  • Lee, Sung-Hyun;Seo, Dong-Kwon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.1
    • /
    • pp.123-131
    • /
    • 2021
  • Purpose : The time spent using smart devices is constantly increasing, particularly in recent times. Using smart devices for a long time with an incorrect posture may lead to cerebral palsy (CP), instability, and abnormal muscle tone. Therefore, we aimed to investigate the relationships among cervical instability, deep neck flexor (DNF) activity, range of motion (ROM), and muscle tonus. Methods : Fifty subjects with CP participated in this study, and they were physiotherapists at W Hospital in Daejeon. Those who voluntarily participated in the research were selected as candidates who fulfilled the selection criteria. According to an instability test, 25 subjects were assigned to the instability and control groups. All subjects first underwent the instability test to be allocated to the appropriate group. Those in the instability group tested positive on the instability test. The Neck Disability Index (NDI), ROM, muscle tone, and DNF activity were measured to evaluate their relationships. The DNF strength and endurance were measured using a cranio-cervical flexion test. The upper trapezius (UT), sternocleidomastoid (SCM), and suboccipital (SO) muscle tones were measured using a contact soft tissue tone measuring instrument. The statistical significance level was set to .05. Results : There were significant differences in the flexion, extension, and rotation of the cervical ROM (CROM) between the two groups (p<.05). The SCM, UT, and SO muscle tones were significantly different between the two groups (p<.05). The DNF strength and endurance showed a significant difference between the two groups (p<.05). Conclusion : We found that there were significant increases in the CROM and muscle tone and decrease in the DNF strength and endurance in the instability group. This indicated that cervical instability is affected by the DNF strength and endurance. We may recommend DNF exercises in cases of cervical instability in clinical environments.

A Study on the Measurement of Back Muscle Fatigue During Dynamic Contraction Using Multiple Parameters (다중 파라메터를 이용한 동적 수축시 허리 근육 피로 측정에 관한 연구)

  • Yoon, Jung-Gun;Jung, Chul-Ki;Yeo, Song-Phil;Kim, Sung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.7
    • /
    • pp.344-351
    • /
    • 2006
  • The fatigue of back muscle in the repetitive lifting motion was studied using multiple parameters(FFT_MDF, RMS, 2C, NT) in this study. Recent developments in the time-frequency analysis procedures to compute the IMDF(instantaneous median frequency) were utilized to overcome the nonstationarity of EMG signal using Cohen-Posch distribution. But the above method has a lot of computation time because of its complexity. So, in this study, FFT_MDF(median frequency estimation based on FFT) algorithm was used for median frequency estimation of back muscle EMG signal during muscle work in uniform velocity portion of lumbar movement. The analysis period of EMG signal was determined by using the run test and lumbar movement angle in dynamic task, such as lifting. Results showed that FFT_MDF algorithm is well suited for the estimation of back muscle fatigue from the view point of computation time. The negative slope of a regression line fitted to the median frequency values of back muscle EMG signal was taken as an indication of muscle fatigue. The slope of muscle fatigueness with FFT_MDF method shows the similarity of 77.8% comparing with CP_MDF(median frequency estimation based on Cohen Posch distribution) method.

Rapid Functional Enhancement of Ankylosing Spondylitis with Severe Hip Joint Arthritis and Muscle Strain (고관절염과 근 긴장을 동반한 강직성 척추염의 빠른 기능 회복)

  • Hwang, Sangwon;Im, Sang Hee;Shin, Ji Cheol;Park, Jinyoung
    • Clinical Pain
    • /
    • v.18 no.2
    • /
    • pp.121-125
    • /
    • 2019
  • Arthritis of hip joints deteriorates the quality of life in ankylosing spondylitis (AS) patients. Secondary to the articular inflammatory process, the shortened hip-girdle muscles contribute to the decreased joint mobility which may lead to the functional impairment. As the limitation of range of motion (ROM) usually progress slowly, clinicians regard it as a chronic condition and prescribe long-term therapy. However, by short-term intensive multimodal treatment, a 20-year-old man diagnosed as AS with severely limited hip joint ROM who relied on crutches doubled the joint angle and could walk independently only within 2 weeks. The combination included intra-articular steroid injection, electrical twitch obtaining intramuscular stimulation, extracorporeal shock wave therapy, heat, manual therapy, and stretching exercises. The management focused on the relaxation of hip-girdle muscles as well as the direct control of intra-articular inflammation. Hereby, we emphasize the effectiveness of intensive multimodal treatment in improving the function even within a short period.

Bilateral Stress Fracture of Femur Neck, Fatigue Type of Non-Athlete Young Adult (젊은 비운동선수인 성인에서 발생한 양측 대퇴 목의 피로골절)

  • Yun, Yeo Joon;Na, Yong Jae;Jung, Ji Won;Lee, Kyu Hoon
    • Clinical Pain
    • /
    • v.18 no.2
    • /
    • pp.126-129
    • /
    • 2019
  • Bilateral femoral neck stress fractures have been rarely reported. When diagnosed, they are usually limited to athletes or military personnel. A 35-year-old man, previously healthy, visited the emergency department for right inguinal pain. On physical examination, no external wound, tenderness or limitation of motion were found in either lower extremity. Plain radiography showed normal findings but an magnetic resonance image showed a linear fracture in the femoral neck. In this case, bilateral femoral neck stress fractures were found in a young non-athlete adult with no prior medical history of related injuries. Surgery is generally not performed for stress fractures but considering the patient's early mobilization and the need for quick reintegration into society, surgery was done in this case.