• Title/Summary/Keyword: CORONA

Search Result 1,319, Processing Time 0.023 seconds

Second harmonic generation of pulsed corona - poled nonlinear optical polymer films (펄스 corona 배향된 비선형광학 고분자박막의 제2 고조파발생)

  • Kim, Jun-Soo;Lee, Jong-Ha;Lee, Hwang-Un;Kim, Sang-Youl;Won, Young-Hee
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.4
    • /
    • pp.356-362
    • /
    • 2002
  • The molecular orientational dynamics of the nonlinear optical(NLO) side-chain polymer N-(4-nitrophenyl)-(L)-prolinol-poly (pphenylene terephthalates) have been studied using nonlinear optical responses as measured by second harmonic generation (SHG). A new pulsed corona poling is used to orient the NLO chromophores and the polymer segments into the noncentrosymmetric structure required to obtain the SHG signal. By corona poling of negative high voltage pulses with variable repetition rates (between 0.5 and 10 ㎑) at temperature between 25$^{\circ}C$ and 80$^{\circ}C$, well below and about the glass transition temperature 70$^{\circ}C$, the side-chain chromophores and the polymer chain contour rearrange themselves and create the domain structure observed by atomic force microscopy(AFM). The pulsed corona voltage enhances the orientational ordering of the NLO chromophores and also significantly influences the growth of SHG signal and the improved relaxation behavior after the poling field is removed, reducing the visible damage to the polymer film dramatically. This new pulsed corona poling experiment gave direct in situ evidence that the NLO chromophore and the polymer backbone undergo anisotropic rearrangement during the poling process.

Corona Discharge Characteristics and Particle Losses in a Unipolar Corona-needle Charger Obtained through Numerical and Experimental Studies

  • Intra, Panich;Yawootti, Artit;Rattanadecho, Phadungsak
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.2021-2030
    • /
    • 2017
  • In this paper, the unipolar corona-needle charger was developed and its capabilities were both numerically and experimentally investigated. The experimental corona discharges and particle losses in the charger were obtained at different corona voltage, aerosol flow rate and particle diameter for positive and negative coronas. Inside the charger, the electric field and charge distribution and the transport behavior of the charged particle were predicted by a numerical simulation. The experimental results yielded the highest ion number concentrations of about $1.087{\times}10^{15}ions/m^3$ for a positive corona voltage of about 3.2 kV, and $1.247{\times}10^{16}ions/m^3$ for a negative corona voltage of about 2.9 kV, and the highest $N_it$ product for positive and negative coronas was found to about $7.53{\times}10^{13}$ and $8.65{\times}10^{14}ions/m^3$ s was occurred at the positive and negative corona voltages of about 3.2 and 2.9 kV, respectively, and the flow rate of 0.3 L/min. The highest diffusion loss was found to occur at particles with diameter of 30 nm to be about 62.50 and 19.33 % for the aerosol flow rate of 0.3 and 1.5 L/min, respectively, and the highest electrostatic loss was found to occur at particles with diameters of 75 and 50 nm to be about 86.29 and 72.92 % for positive and negative corona voltages of about 2.9 and 2.5 kV, respectively. The numerical results for the electric field distribution and the charged particles migration inside the charger were used to guide the description of the electric field and the behavior of charged particle trajectories to improve the design and refinement of a unipolar corona-needle charger that otherwise could not be seen from the experimental data.

Coastline Change Detection Using CORONA Imagery (CORONA 위성영상을 이용한 동해안 해안선 변화탐지)

  • Kim Gi Hong;Choi Seung Pil;Yook Woon Soo;Song Yeong Sun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.4
    • /
    • pp.419-426
    • /
    • 2005
  • Recently the interest in coast area has been increased in the view of management and usage of national territory. Rapid coastal development has caused directly or indirectly coastline changes which may make environmental problems or threaten the nearby residents' livelihood. CORONA was one of the US satellite reconnaissance programs, and it's imagery provides informations about past coastline with high resolution. In this study, we applied rigorous geo-referencing algorithm to CORONA imagery in order to generate the mosaic image of the East coast area of 1969 with 20m accuracy. This old era CORONA mosaic image was compared with SPOT image of 2005, and the coastline changes were analyzed. We were able to ascertain considerable erosion and accumulation in some parts of study area. erosion area which is calculated from imagery is $0.32\;km^2$ from Kosung to Kangnung. Results of coastline change detection can provide useful information for related studies.

A Study on the Effects of I&C Systems by EMI Generating from Corona Discharge at Transformer Area (변압기 지역 코로나 전자파 간섭에 의한 계측제어설비 영향에 관한 연구)

  • Min, Moon-Gi;Lee, Jae-Ki;Park, Jin-Yeub;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.266-271
    • /
    • 2014
  • The Electromagnetic Interference(EMI) generating from corona discharge of transformer area can interference the digital Instrument and Control(I&C) systems located nearby transformers. When the potential gradient of the electric field around the conductor is high enough to form a conductive region but not high enough to cause electrical breakdown to nearby objects, the EMI of corona discharge emits with the conducted and radiated noise and it interferences the signals of the I&C systems. Since digital I&C systems have an efficiency and competitive price, the analog I&C systems have been upgraded and displaced with the digital I&C systems but which have less EMI Immunity. There was no assessment to I&C systems by EMI generating corona discharge nearby transformers. When the safety-related I&C systems are installed in plants, the verification of equipment EMI should be done not in site-specific test but in test facilities. There are the need to do the site-specific EMI evaluation of corona discharge nearby transformers. This paper assesses the margin between plant emission limits and the highest composite plant emission of corona. When the non safety-related I&C systems are placed in transformer area, it suggests the appropriate radiated susceptibility level to EMI of corona discharge.

An Automatic Corona-discharge Detection System for Railways Based on Solar-blind Ultraviolet Detection

  • Li, Jiaqi;Zhou, Yue;Yi, Xiangyu;Zhang, Mingchao;Chen, Xue;Cui, Muhan;Yan, Feng
    • Current Optics and Photonics
    • /
    • v.1 no.3
    • /
    • pp.196-202
    • /
    • 2017
  • Corona discharge is always a sign of failure processes of high-voltage electrical apparatus, including those utilized in electric railway systems. Solar-blind ultraviolet (UV) cameras are effective tools for corona inspection. In this work, we present an automatic railway corona-discharge detection system based on solar-blind ultraviolet detection. The UV camera, mounted on top of a train, inspects the electrical apparatus, including transmission lines and insulators, along the railway during fast cruising of the train. An algorithm based on the Hough transform is proposed for distinguishing the emitting objects (corona discharge) from the noise. The detection system can report the suspected corona discharge in real time during fast cruises. An experiment was carried out during a routine inspection of railway apparatus in Xinjiang Province, China. Several corona-discharge points were found along the railway. The false-alarm rate was controlled to less than one time per hour during this inspection.

Surface Safety Characteristics of Polypropylene Surface Treatment by Variation of Rolling Speed and The Electric Power of Corona Discharge (코로나방전 표면 처리시 이동속도 및 공급전력 변화에 따른 폴리프로필렌 표면 안전성 특성)

  • Lee, Su Hwan;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.41-46
    • /
    • 2018
  • Experiments were carried out the phenomenal observation on effect of corona treated hotmelt laminating film in process of manufacture by 2 kinds of rolling speed and electric power variatons. Surface treatment by corona which is exposure of film surface to electron of ion bombardment, rather than mere exposure to active species, like atomic oxygen or ozone, can enhance adhesion by removing contaminant, electret, roughening surface, and introducing reactive chemical group. Reactive neutrals, ions, electron and photons generated during the corona treatment interact simultaneously with polymers to alter surface chemical composition, wettability, and thus film adhesion. However, it is highly recommended that extensive chains scission is avoided because it can lead to side-effect by forming sticky matter, resulting in dropouts. This paper reviews principles of surface preparation of polypropylene substrate by corona discharging. In addition, the experimental section provides a description of parameter optimization on corona discharging treatment and its side-effect. Experimental results are discussed in terms of surface wetting as determined by contact angle and SEM measurements. When the rolling speed of the film decreased from 1.666 [m / sec] to 0.083 [m / sec], contact angle decreased from $80[^{\circ}]$ to $64[^{\circ}]$, and the wettability was greatly improved. As the supply power increased from 0.4 [kVA] to 2 [kVA] at the corona discharge surface treatment, the contact angle decreased from $77[^{\circ}]$ to $65[^{\circ}]$, and the wettability was greatly improved.

Corona generated Radio Interference of the 750 kV AC Bundle Conductors in Sandy and Dusty Weather Condition in the High Altitude Area

  • Liu, Yun-Peng;Zhu, Lei;Lv, Fang-Cheng;Wan, Bao-Quan;Pei, Chun-Ming
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1704-1711
    • /
    • 2014
  • Sandy and dusty weather condition often occurs in the high altitude areas of China, which may greatly influence the corona generated radio interference (RI) characteristics of the bundle conductors of 750 kV AC power transmission lines. Corona generated RI of the conductors of the 750 kV AC power transmission lines used in practice is measured by EMI receiver with a coupling circuit and a coupling capacitor connected between the high voltage side and the earth side in fine and sandy and dusty condition. The measuring frequency is 0.5 MHz, and the quasi-peak detection is used. RI excitation function is calculated based on the corona RI current measured by the EMI receiver. Corona generated RI characteristics were analyzed from sand concentration and sand particle size. The test result shows that the corona generated RI excitation function is influenced by the sandy and dusty condition. Corona discharge of the conductors is more serious in sandy and dusty condition with an ultraviolet (UV) detector. Corona generated RI excitation function increases with the increase of sand concentration and also increases with the increase of particle size.

A Trial for Improvement of Energy Efficiency of Plasma Reactor by Superposing Two Heterogeneous Discharges - Characteristics of Surface and Corona Discharge Combined Plasma Reactor - (이종방전 중첩에 의한 방전 플라스마반응기의 효율개선의 시도 - 연면.직류코로나 방전 중첩형 반응기의 특성 -)

  • ;Mizuki Yamaguma
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.66-70
    • /
    • 2000
  • In order to cope with environmental problems caused by harmful gases emitted from various industrial sources, a new technology which employs discharge plasma formed in ordinary atmospheric pressure has been intensively investigated in many industrialized nations. Although a plenty of useful outcomes and suggestions have been made public by scientists in this field, few commercial products which effectively decompose pollutant gases have appeared as yet. This is partly because that the energy efficiency of a most effective plasma reactor has not reached a satisfactory level in comparison with those of devices using conventional technologies. In an attempt to solve the problem mentioned above, we noticed to combine heterogeneous electrical discharges. This concepts is based on that each plasma reactor has its specific spatial region in which chemical reaction are active and by electrically affected with another reactor of different type, the activated region would increase - which may lead to cutting down the energy consumption. To prove this concept experimentally, two different discharge equipments, a plane ceramic-based surface discharge electrode and a corona electrode with tungsten needle may, are selected and combined to fabricate a hybrid plasma reactor. The results are summarized as follows; (1) Ozone concentration generated in the plasma region drastically increases when the positive corona discharge is added to the surface discharge. The rate of increase of ozone depends on the frequency of the surface discharge. The negative corona, however, does not contribute to the improvement of the ozone generation. (2) NO(nitrogen monoxide) decomposition rate also improves by simultaneously applying the surface and the positive corona discharges. The effect of the corona superposition is more evident when the level of the surface discharge is moderate. (3) By adjusting the corona level, the net energy efficiency during NO decomposition improves in comparison with the simple surface discharge reactor.

  • PDF

THE CORONA THEOREM FOR BOUNDED FUNCTIONS IN DIRICHLET SPACE

  • Nah, Young-Chae
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.10 no.1
    • /
    • pp.141-146
    • /
    • 1997
  • In this paper we prove that the corona theorem for the algebra $H^{\infty}(D){\cap}D(D)$. That is, we prove that $\mathcal{M}{\setminus}{\overline{D}}$ is an empty set where $\mathcal{M}$ is the maximal ideal space of the given algebra.

  • PDF

Multiple-Wire Corona Discharge TEA-$CO_2$ Laser의 설계 및 제작

  • 김기호;오차환;이상수
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1988.06a
    • /
    • pp.41-46
    • /
    • 1988
  • 본 논문에서는 wire discharge 방법의 응용인 Multiple-wire corona discharge (NW CD)의 preionization field를 계산하였고, 동일한 조건하에서 Surface corona discharge (SCD) 와 Wide discharge(WD) 의 preionization filed와 비교하여보았다. 그에 따른 결과로써 NWCD가 고출력 TEA-CO2 레이저에 가장 좋은 선전리 방법임을 알 수 있었다.

  • PDF