• Title/Summary/Keyword: COPs

Search Result 102, Processing Time 0.025 seconds

The Effect of Age and Dual Task to Human Postural Control (연령와 이중과제 수행이 자세제어에 미치는 영향)

  • Shin, Sunghoon;Jang, Dae-Geun;Jang, Jae-Keun;Park, Seung-Hun
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.2
    • /
    • pp.169-177
    • /
    • 2013
  • The purpose of this study is to investigate the effect of aging and dual tasking to the postural control during quiet standing. It was hypothesized that the center of pressure (COP) dynamics would be differently affected by aging and characteristics of the task. Total 60 adults (35 young adults and 25 older adults) participated in this study. They conducted two different standing tasks (dual vs. Nondual) twice in a random order. Variability, complexity, coupling and symmetric index from the left, right and overall COPs were measured by various parameters in nonlinear, linear and frequency analyses methods. Results demonstrated that older adults had worse performance in postural control with decreased complexity in overall sway movement, and increased coupling between left and right limb COP movement, even though there was no significant difference in symmetric index. These tendencies are generally clearer in nonlinear measures at the dual task condition. Results implied that older adults had compensatory strategy in dual tasking which results in simple and combined postural movement patterns.

Numerical Simulation of a Two-Stage Hybrid Heat Pump (2단 압축 하이브리드 히트펌프의 특성 시뮬레이션)

  • Jeong, Si-Young;Yun, Han-Gu;Park, Ki-Woong;Park, Seong-Ryong;Kim, Min-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.191-196
    • /
    • 2010
  • Hybrid heat pumps, which combine the vapor compression and absorption heat pump cycle, can efficiently produce hot water of $80^{\circ}-90^{\circ}C$ from the low temperature of ${\sim}50^{\circ}C$. In this study, the performance of a two-stage hybrid heat pump (HHP) was compared with a single-stage hybrid heat pump using EES (Engineering Equation Solver). For the same operating conditions, the two-stage HHP showed a slightly higher COP (Coefficient Of Performance) and more stable operating conditions than the single-stage HHP. Moreover, the maximum working fluid temperature of the two-stage HHP was found to be lower than that of the single-stage HHP by about 40 K, which makes the working conditions of the lubricating oil safer. The COPs of both systems decreased with increasing UA-values. However, the heat output of the HHP was increased at the same time.

Effects of Whole Body Fatigue and Limited Visual Field on Postural Stability (전신 피로와 시야 제한이 자세균형 능력에 미치는 영향)

  • Park, Sung Ha
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.3
    • /
    • pp.39-46
    • /
    • 2016
  • Loss of postural stability can possibly lead to slip and fall accidents in the number of workplaces and everyday life. This study was aimed to examine the effects of whole body fatigue and partially limited visual field on the ability of maintaining postural balance during quiet standing. A group of twelve healthy male subjects participated in the experiment. Before and after experiencing the whole body fatigue induced by bicycling exercises, the position coordinates of subject's center of pressure (COP) were obtained under the two levels of visual field condition (i.e., open visual field and limited visual field). Four levels of the whole body fatigue examined were rest, 300watt, 600watt, and 900watt. Position coordinates of COPs measured on a force plate were then converted into the total length of postural sway path in both the medio-lateral (ML) direction and the anterior-posterior (AP) direction. Two-way ANOVA result showed that the length of sway path in the AP direction became significantly larger as the whole body fatigue accumulated. Post-hoc test revealed statistically significant differences between rest and 900watt and between 300watt and 900watt. The significant increase of the sway length was also found when the visual field was partially obstructed by the boxes. In the ML direction, however, there was no statistically significant difference of the postural sway in both the AP and ML directions. The results imply that the ability of maintaining postural stability can be reduced significantly due to such tasks along with whole body fatigue. The postural balance can also be impaired by the limited visual field.

A QoS Adaption Model on the Policy-Based Network Management in the IMS (IMS에서 정책 기반 네트워크 관리 QoS 적용 모델)

  • Han, Seok-Jun;Lee, Jae-Oh;Kang, Seung-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.3175-3181
    • /
    • 2012
  • The need of multimedia based application service is increasing as the number of smart mobile devices such as smart phone, tablet PC, and netbook is increasing rapidly and the development of application service like IPTV. There are various proposed policies to control the limited network resources. The IMS is used to control wired and wireless aggregation network to support multimedia services that are suitable to the user's need and the policy based models using the PDF of the IMS have emerged. In this paper, we propose the QoS adaption model using various protocols with the PDF of the IMS and the user scenario.

Recognition of Machining Features on Prismatic Components (각주형 부품상의 가공 특징형상 인식)

  • 손영태;박면웅
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1412-1422
    • /
    • 1993
  • As a part of development of process planning system for mold die manufaturing, a software system is developed, which recognizes features and extracts parameters of the shape from design data produced by solid modeller. The recognized feature date is fed to process planning and operation planning system. Low level geometry and topology data from commercial CAD system is transformed to high level machining feature data which used to be done by using a dedicated design system. The recognition algorithm is applied to the design data with boundary representation produced by a core modeller ACIS which has object oriented open architecture and is expected to become a common core modeller of next generation CAD system. The algoritm of recognition has been formulated for 21 features on prismatic components, but the feature set can be expanded by adding rules for the additional features.

An Architecture of ISP-based P2P IPTV Services and Its Characteristics (계층 구조형 ISP 기반 P2P IPTV 서비스 구조 및 특성)

  • Sung, Moo-Kyung;Han, Chi-Moon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.4B
    • /
    • pp.659-669
    • /
    • 2010
  • The P2P IPTV will create a new paradigm for the Internet services. However, it cannot guarantee the reliability of their server and QoS because of using common Internet users(peers) for SIP server or relay server, though the infrastructural cost is low. This paper proposes the ISP-based P2P IPTV architecture which can solute the limitations of conventional P2P-based IPTV. In this model, ISP can build P2P overlay network with ISP servers and directly manage each server needed for session connection. So, the servers have higher performance and better reliability than previous one. Besides, robustness is improved because each sever is set by P2P overlay network. To evaluate the characteristics of the ISP-based P2P IPTV architecture, we simulate it for some parameters which are end-to-end streaming delay time, connection delay time and traffic amount. We compared the proposed architecture with the conventional P2P architecture about video service and confirmed that the performance of ISP-based P2P IPTV is better than conventional P2P based IPTV.

A Study of Iris Van Herpen Fashion from the Perspective of Deleuze's Sensory Theory (들뢰즈의 감각론의 관점으로 본 아이리스 반 헤르펜 패션에 관한 연구)

  • Song, Haein;Kim, Jinyoung
    • Journal of Fashion Business
    • /
    • v.24 no.4
    • /
    • pp.117-129
    • /
    • 2020
  • Just as the name 'aesthetics' implies, the meaning of 'aisthesis' or 'sense' in Greek, is perceived as an important element in modern social design. Gilles Deleuze emphasized sensory expression over the rational side of the body, and argued for sensory theory, which is the theory of how painting produces new senses. The purpose of this study was to theoretically examine the sensory theory of Deleuze, which has given new value to the senses, apply it to analyze the body expression method shown in the Iris van Herpen collection, and derive its aesthetic characteristics. In his sensory theory, Deleuze argued that the senses can be expressed by the embodiment of force and rhythm, and one can only create art through the senses. To develop one's philosophical logic through Bacon's painting, we divided it into Hysteria, Cops sans organs, Diagram, Becoming, and Paired figures. Based on these analyses, the visualization of the senses in Iris van Herpen fashion resulted in hysteria, organ-free body, diagrams, and heterogeneity combinations. Analysis of the method of expression revealed rhythmicity, atypicality, scalability, and reproducibility as expression characteristics. Applying Deleuze's sensory theory to access experimental Iris van Herpen's fashion could confirm that there was an open system's accessibility. Deleuze's sensory theory, which has given a new value to the senses, will further help to understand modern fashion design in a wide and diverse way and discover the intrinsic value within it.

Comparison of Exergy in a Refrigerating System using R404A and R134a for a Refrigeration Truck with Operating Conditions (운전조건에 따른 R404A와 R134a를 적용한 냉동탑차용 냉장시스템의 엑서지 비교)

  • Shin, Yunchan;Kim, Taejung;Cho, Honghyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.11
    • /
    • pp.497-503
    • /
    • 2014
  • The performances of refrigeration truck systems using R404A and R134a were investigated by experimental testing, and compared. The optimal COPs of the R404A and R134a systems were 2.96 and 3.42, when the refrigerant charge amount was 1.3 kg and 1.4 kg, respectively. When the indoor side air temperature increased from $5^{\circ}C$ to $9^{\circ}C$, the total exergy destruction rate of the R404A system was on average 39.1% higher than that of the R134a system. In addition, the exergy efficiency of the R404A system was 12.9% higher than that of R134a system, for various indoor air temperatures. When the outdoor side air temperature increased from $25^{\circ}C$ to $35^{\circ}C$, the total exergy destruction rate of the R404A and R134a systems decreased by 18.9% and 19.5%, respectively. In addition, the exergy efficiency of the R404A and R134a systems increased by 25.2% and 30.7%, respectively. As the compressor rotating speed increased, the COP of the R404A and R134a systems decreased by 23.6% and 18.4%. The total exergy destruction rate and exergy efficiency of the R404A system were 27.2% and 15.7% higher than those of R134a system, respectively. Compared to the R404A system, the R134a system showed a higher COP and a lower exergy destruction rate; thus it can be concluded that the R134a system has the better performance.

Experimental Study on the Performance of a $CO_2$ Heat Pump Water Heater ($CO_2$ 급탕 열펌프의 성능 특성에 관한 실험적 연구)

  • Lee, Eung-Chan;Baek, Chang-Hyun;Kang, Hoon;Kim, Yong-Chan;Cho, Hong-Hyun;Cho, Sung-Wook
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.6
    • /
    • pp.367-372
    • /
    • 2009
  • The performance of a $CO_2$ heat pump water heater was measured with a variation of operating conditions such as refrigerant charge amount, outdoor temperature, compressor frequency, EEV opening, and water mass flow rate. The optimum refrigerant charge amount of the $CO_2$ system was 1800 g. At water mass flow rates of 75, 85, and 95 kg/h, the water heating temperatures were 74, 67, and $62^{\circ}C$ and COPs were 2.6, 2.8, and 3.0, respectively. Besides, the compressor frequency and water mass flow rate were adjusted to maintain the water heating temperature at $60^{\circ}C$ with the decrease of outdoor temperature. As the outdoor temperature decreased by $5^{\circ}C$, the compressor frequency increased beyond 60 Hz and the water mass flow rate decreased by 16.7%.

Drop-In Evaluation of Thermodynamic Performance of R-22 Alternative Refrigerant Mixtures (R-22 대체용 혼합냉매의 Drop-In 열역학적 성능 계산)

  • Ju, J.M.;Kim, C.N.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.423-436
    • /
    • 1996
  • Thermodynamic performance of eight zeotropic R-22 alternative refrigerant mixtures selected by AREP(R-22 Alternative Refrigerants Evaluation Program) and R-32/R-125/R-134a(23%/25%/52%), namely R-407C were evaluated by the "drop-in" simulation method. An existing air conditioner was selected and its design data were used for the simulation. "ARI Test A" air conditions were applied. The degree of vapor superheat at the compressor inlet fixed at $5^{\circ}C$ for all the mixtures. The results of the simulation were compared with those of R-22. COPs of all mixtures except for R-32/R-227ea(35%/65%) and R-32/R-125/R-134a(10%/70%/20%), were higher than that of R-22 by 2%~8%, while the capacities were all lower than that of R-22 by 13%~27%. COP of R-32/R-134a(40%/60%) was 2.4% higher but the capacity was 15% lower than those of R-22. In the case of R-32/R-134a(30%/70%), COP and capacity were 5.5% higher and 15% lower than those of R-22, respectively. Among the ternary mixtures, R-407C and R-32/R-125/R-134a(30%/10%/60%) showed the best performance. COP of R-407C was 2.4% higher than those of R-22 but the capacity was 15% lower.

  • PDF