Experimental Study on the Performance of a CO2 Heat Pump Water Heater under Various Operating Conditions (이산화탄소 급탕 열펌프의 운전조건에 따른 성능 특성에 관한 실험적 연구)

  • Sohn, Dong-Jin;Baek, Chang-Hyun;Heo, Jae-Hyeok;Kang, Hoon;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.273-280
    • /
    • 2011
  • In this study, the steady state performance of a $CO_2$ heat pump water heater was measured with a variation of operating conditions such as refrigerant charge amount, compressor frequency, EEV opening, and water mass flow rate. Transient state performance tests were also conducted to investigate major system effects associated with the interaction between the $CO_2$ heat pump water heater and the water tank. Optimum refrigerant charge amount for the system was 1600 g. At compressor frequencies of 50 Hz and 60 Hz, water mass flow rates of 95 kg/h and 105 kg/h, and EEV opening of 8% and 16%, the water heating temperatures were $65^{\circ}C$ and $68^{\circ}C$ and COPs were 3.0 and 2.8, respectively. In the transient condition, the instantaneous COP decreased with an increase in the inlet water temperature.

The com.mit.ted unit, the strength, The Organization, and The battle formation of the Silla Force During the Silla-Baekche War at 660 A.D (신라가 대백제전시(서기 660년) 투입하였던 부대수, 병력수, 부대편제, 전투대형)

  • Yoon, Il-Young
    • Journal of National Security and Military Science
    • /
    • s.5
    • /
    • pp.393-599
    • /
    • 2007
  • In order to restore the Hwangsanbeol Combat at present, it is necessary to make a close examination on the name of the military cops, the number of units, and the numerical strength, an unit organization, and a combat formation. Based on Samguksagi, Samgukyusa, other historical documents and military history information, I tried to restore the Hwansanbeol Combat as follow. The Shilla, at the 7 year of Mooyeol Dynasty, AD. 660, maintained 35 military units. The Shilla committed18 military units from among 35 units to battle against Baekje at the 7 Year of Mooyeol Danasty. The names ofmilitary units are as follow: 1) Daedang, 2) Sangjoojeong, 3) Hajoojeong, 4) Seodang, 5) Nangdang, 6) Eumlihwajeong, 7) Samryanghwajeong, 8) Sosarnjeong, 9) Namcheonjeong, 10) Leehwahaejeong, 11) Kaegeumdang, 12) Geupdang, 13) Nodang, 14) Woonjaednag, 15) Chungdang, 16) Suktoodang, 17) Gwidang, and 18) Soogun. The numerical strength, which the Shilla maintained at the year of A.D. 660, was total 106,353 persons from 35 military units. Shilla committed 57,433 military personnel to combats against the Great Baekche. Ground Forces from the 57,433 personnel were 58,343 persons, and the naval forces were 9,100 persons. Finally, 2,602 persons from among the 9,100 naval forces were only combating forces, and non-combat forces were 6498 persons.

  • PDF

Cooling and Heating Performance Evaluation of a Ground Source Heat Pump (지열원 열펌프의 냉.난방 성능 평가)

  • Sohn, Byong-Hu;Cho, Chung-Sik;Shin, Hyun-Joon;An, Hyung-Jun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2117-2122
    • /
    • 2004
  • The main objective of the present study is to investigate the performance characteristics of a ground source heat pump (GSHP) system with a 130 m vertical 60.5 mm nominal diameter U-bend ground heat exchanger. In order to evaluate the performance analysis, the GSHP system connected to a test room with 90 $m^2$ floor area in the Korea Institute of Construction Technology ($37^{\circ}39'$ N, $126^{\circ}48'$ E) was designed and constructed. This GSHP system mainly consisted of ground heat exchanger, indoor heat pump and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July to January in cooling and heating season of $2003{\sim}2004$. The cooling and heating performance coefficients of the system were determined from the experimental results. The average cooling and heating COPs for the system were obtained to be 4.82 and 3.02, respectively. The temperature variations in ground and the ground heat exchanger surface at different depths were also measured.

  • PDF

Theoretical and Experimental Evaluation of R502 Alternatives in Low Temperature Applications (저온용 R502 대체 냉매의 이론 및 실험적 평가)

  • Kwon, S.L.;Park, Y.B.;Jung, D.S.;Kim, C.B.;Kang, D.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.4
    • /
    • pp.654-666
    • /
    • 1995
  • R502 has been extensively used as a working fluid in transport refrigerating vehicles and low temperature refrigerating machines but is to be phased out by the end of 1995 due to ozone layer depletion problem. In this study, both theoretical cycle analysis and experiments were carried out to examine the best substitutes for R502. Theoretical results indicate that the alternatives available in the market today may replace R502 without significant changes in the system without suction line heat exchanger(SLHX). When the system contains a SLHX, however, COPs of the alternatives increase up to approximately 15~20% than those without the SLHX. But simultaneously, the discharge temperatures of the compressor also increrease significantly with the SLHX. Actual test results obtained from the experiment with a transport vehicle's refrigerator indicate the similar trend as those of the theoretical results. Especially, HFCs and their mixtures show lower discharge temperature than those of R502, which is one of the desirable features. Further research is needed to study the effect of the SLHX on the performance of the real machine as well as on the oil return for reliability of the system.

  • PDF

An Experimental Study on the Effects of Operating Variables on the Cooling and Heating Performance of Geothermal Heat Pump (지열 히트펌프에서 운전변수가 냉난방 성능에 미치는 영향에 대한 실험연구)

  • Chang, Keun-Sun;Kang, Hee-Jeong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.8
    • /
    • pp.562-570
    • /
    • 2011
  • In this research, an experimental study is performed to investigate the effects of system operating variables on the cooling and heating characteristics of heat pump system using geothermal heat source and carbon dioxide as a refrigerant. System variables analyzed include compressor frequency, electronic expansion valve opening, refrigerant charge, secondary fluid temperature and flow rate. Results show that optimum refrigerant charge and electronic expansion valve opening position exist at the maximum point of COP curve, and both cooling and heating capacity increase but COPs decrease with the increase of compressor frequency. The change of a secondary fluid temperature leads to variation of overheat area and enthalpy difference in the evaporator and gas cooler. which again results in considerable variations of cooling and heating capacity and COP. In the case of effects of secondary water fluid flow rate, both cooling capacity and COP increase with the increase of secondary flow in evaporator or gas cooler, whereas heating capacity and COP decrease with the increase of flow rate in gas cooler.

Experimental Study on Cooling and Heating Operation Characteristics of Inverter type Multi-Heat Pump (인버터형 멀티 히트펌프의 냉난방 운전특성에 대한 실험연구)

  • Park, B.K.;Seo, D.N.;Um, Y.S.;Kwon, Y.C.;Ko, K.W.
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.618-622
    • /
    • 2007
  • In the present study, the cooling and heating operation characteristics of a multi-heat pump have been experimentally investigated for the number of the indoor units(A, B, C) and the operating conditions. The heat pump was controlled by an inverter scroll compressor. The performance of the heat pump was measured by the multi-calorimeter of an air enthalpy method. Cooling and heating capacities and COPs were obtained at the cooling and heating temperature conditions and the setting temperatures of an indoor unit. With increasing the operation frequency of the compressor, the cooling and heating capacities of the heat pump increased linearly. The operation frequency region of the compressor was different as the combination of the indoor unit and the cooling/ heating condition.

  • PDF

Compute simulation of a three-stage condensation heat pump (3단 응축 고온/고효율 열펌프의 전산해석)

  • 이윤학;정동수;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.3
    • /
    • pp.303-314
    • /
    • 1998
  • In this study, the performance of a multi-stage condensation heat pump was examined. Computer simulation programs were developed for 1-stage, 2-stage, and 3-stage heat pumps and R11, R123, R141b were tested as working fluids. The results showed that coefficients of performance(COPs) of an optimized 3-stage condensation heat pump are 25∼40% higher than those of a conventional 1-stage heat pump. The increase in COP, however, differed among the fluids tested. The improvement in COP largely stems from the decrease in average LMTD values in the condensers of the multi-stage system. For the 3-stage condensation heat pumps, optimized UA values of three condensers were determined to be 30∼40% of the UA value of the total condenser regardless of the working fluid. When the amount of cooling water entering into the intermediate and high-stage subcoolers is roughly 10% of the total condenser cooling water respectively, the optimum performance was achieved for the 3-stage condensation heat pump.

  • PDF

An Experimental Study on the Performance Characteristics of a Single-Circuit Multi Cycle and a Bypass Two-Circuit Multi Cycle (단일유로 멀티사이클 및 바이패스유로 멀티사이클 적용 냉동시스템의 성능특성에 관한 실험적 연구)

  • Song, Young-Seung;Jung, Hae-Won;Yoon, Won-Jae;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.7
    • /
    • pp.513-519
    • /
    • 2011
  • The object of this study is to investigate the performance characteristics of refrigerators using a single-circuit multi cycle and a bypass two-circuit multi cycle. Each refrigeration cycle was tested by varying secondary fluid mass flow rate and temperature. Based on the experimental data, the optimum refrigerant charge was 48 g and the COP at the optimum secondary fluid mass flow rate was 1.53 for the single-circuit multi cycle. For freezer(F)-only mode, both the single-circuit multi cycle and the bypass two-circuit multi cycle were operated at overcharge conditions, resulting in an increase of the secondary fluid mass flow rate. The maximum COPs of the single-circuit multi cycle and the bypass two-circuit multi cycle were 1.22 and 1.35, respectively. The COP increased by 10.7% with the application of the bypass two-circuit multi cycle.

Ability to Maintain Postural Control while Standing on Perturbed Surfaces (바닥면의 교란에 따른 자세균형능력의 변화)

  • Park, Sung-Ha;Lee, Seung-Won
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.31 no.4
    • /
    • pp.146-152
    • /
    • 2008
  • This study was aimed to understand the effects of perturbed floor surface on human postural stability while standing. Ten subjects were asked to stand quietly on the surface with two angles of inclination ($0^{\circ}$ and $5^{\circ}$), two contamination conditions (dry and oil-contaminated), and three commercial floor materials (ceramic tile, coated wood, and vinyl tile). During each trial, a force plate with data acquisition systems was used to collect subject's center of pressure (COP) position. Measured COPs were then converted into the length of postural sway path in both subject's anterior-posterior (AP) and medio-lateral (ML) axis. Results showed that the length of sway path in ML axis was significantly affected by the angle of inclination and the type of floor material. The sway length was increased significantly at the inclination angle of $5^{\circ}$ and on the vinyl tile, respectively. The contamination condition, however, did not significantly affect the postural sway length in both AP and ML axis. The results imply that a proper treatment of floor surface and material is critical to preserving postural balance while standing.

Effects of Footwear and Workload on Static Body Balance of Farmers (농업인의 작업화 유형과 작업 부하가 정적 자세균형에 미치는 영향)

  • Park, Sung Ha
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.2
    • /
    • pp.39-47
    • /
    • 2020
  • Postural stability can reduce the likelihood of critical slip and fall accidents in workplaces. The present study aimed to analyze the effect of shoes type on the ability of postural control during quiet standing. The effect of workload on the body balance was also of primary concern. Thirteen healthy male undergraduate students participated voluntarily in the experimental study. Standing on a force plate with wearing slippers, sports shoes, or safety shoes, two-axis coordinate on subjects' center of pressures (COP) was obtained in the two levels, rest and workload. For the workload level, subjects performed treadmill exercise to reach the predetermined level of physical workload. By converting the position coordinates of COPs, the postural sway length in both anterior-posterior (AP) axis and medio-lateral (ML) axis was assessed. ANOVA results showed that, in AP direction, wearing slippers significantly increased the postural sway length compared to wearing sports shoes or safety shoes. No significant difference in the mean sway length in AP axis was observed between sports shoes and safety shoes. In ML direction, both the workload and the shoes type did not significantly affect the mean length of postural sway. However, the postural sway length increased marginally with the slippers especially during the workload condition. This study explains wearing slippers may interfere with the ability of postural control during quiet standing. Physical workload decreases the ability of postural stability further.