• Title/Summary/Keyword: COP1

Search Result 520, Processing Time 0.024 seconds

Evaluation of Operational Performance and Carbon Emissions for the Feasibility of Air Source Heat Pump Application in Residential Buildings (공동주택의 공기열원 히트펌프 적용가능성 검토를 위한 운전성능 및 탄소배출량 평가)

  • Junseok Kim;Jongsoo Kim;Yongseok Jeon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.20 no.2
    • /
    • pp.24-36
    • /
    • 2024
  • This study analyzed the feasibility of the air source heat pump in residential buildings based on operational performance and carbon emissions. The operational performance and carbon emissions were compared between a gas boiler and an air source heat pump by calculating the annual heating and hot water load based on the 21A and 36A models for actual residential buildings. For the operational performance of the air source heat pump, the lowest (2.3) and highest COP (5.9) were attained during the winter and summer seasons, respectively. The carbon emissions depend on the amount of energy consumed during operations. An air source heat pump consumed 65.10% and 65.4% less energy per year in the 21A and 36A models, respectively compared to the existing gas boiler. Consequently, for air source heat pump carbon emissions were also reduced by 13.3% and 15.1% per year for the 21A and 36A models, respectively. It shows the effectiveness of applying an air source heat pump compared to an existing gas boiler.

Analysis on Cooling Effects of the Vertical Type Geothermal Heat Pump System Installed in a Greenhouse for Raising Seedling (수직형 지열히트펌프 시스템의 육묘 온실 냉방 효과 분석)

  • Kang, Youn Ku;Ryou, Young Sun;Kim, Jong Goo;Kim, Young Hwa;Jang, Jae Kyoung
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.19-25
    • /
    • 2013
  • In this study, the cooling experiment was carried out in $1,650m^2$ area of the seedling greenhouse from June 6, 2011 to september 18, 2011 with the vertical type geothermal heat pump system of 350 kW scale (175 kW ${\times}$ 2 units) installed in the greenhouse, cooling effects were analyzed and we tried to find more effective operation methods of the geothermal heat pump system. In case of one unit heat pump (175 kW) operation, when evaporator inlet water temperature changed from $13.0^{\circ}C$ to $15.5^{\circ}C$, cooling COP of the system was in 1.1~1.8 range and in case of two unit heat pump (350 kW) operation, when evaporator inlet water temperature changed from 13.0 to 15.5, cooling COP of the system was in 2.0~2.7 range. The accumulated cooling heat quantity of June, July, August and September was 14,718.6, 26,765.1, 28,437.2 and 10,065.0 kWh, respectively.

Influence on the Ground Reaction Force Parameters According to Wearing Positions of Backpacks During Stair Ascending and Descending (계단 오르기와 내리기 시 가방착용 위치가 지면반력 파라미터에 미치는 영향)

  • Hyun, Seung-Hyun;Ryew, Che-Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.85-94
    • /
    • 2015
  • Purpose : The purpose of this study was to investigate the influence on the ground reaction force parameters according to wearing positions of backpack for during stair ascending and descending. Methods : Participants selected as subject were consisted of young female(n=10) and performed stairs walks(ascending and descending) with 2 types of wearing position(front of trunk[FT], rear of trunk[RT]). Passive(Fz 1) and active(Fz 2) forces of the vertical GRF were determined from time function and frequency domain. Also shear forces(Fx, Fy 1, Fy 2), dynamic postural stability index(MLSI, APSI, VSI, DPSI), loading rate and center of pressure (${\Delta}COPx$, ${\Delta}COPy$, COP area) were calculated from time function and frequency domain. Results : Fx, Fy 1, Fy 2, and Fz 1 in GRF didn't show significant differences statistically according to the wearing positions of backpack(p>.05), but stair descending showed higher forces than that of stair ascending. Particularly, Fz 2 of stair ascending showed higher forces than that of stair descending(p<.001), RT types showed higher than that of FT types(p<.05). MLSI, APSI, VSI, and DPSI of stair descending showed the increased stability index than that of stair ascending(p<.05), MLSI of RT types showed the decreased stability index than that of FT types(p<.05). Loading rate didn't show significant differences statistically according to the wearing positions of backpack(p>.05), but stair descending showed higher loading rate than that of stair ascending(p<.001). Also, ${\Delta}COPx$ in stair descending showed the increased movement than that of stair ascending(p<.05). Conclusions : A backpack of 10 kg(10 kg(ratio of body weights $17.61{\pm}1.17%$) showed significantly change GRF parameters according to wearing positions during stair ascending and descending. If possible, we suggest that the dynamic stability, in case of stairs walking with a smaller weights can be further improved.

An Experimental Study on the Performance Characteristics of a Multi Type Refrigerator Using R600a (R600a를 이용한 소형 멀티형 냉장고 시스템의 성능특성에 대한 실험적 연구)

  • Ahn, Ji-Hoon;Jang, Yong-Hee;Kim, Yong-Chan;Choi, Won-Seop;Oh, Seung-Whan;Kim, Chang-Nyeun;Lee, Jae-Seung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.4
    • /
    • pp.222-228
    • /
    • 2009
  • Various types of refrigerators become popular in the market such as a common refrigerator, kimchi refrigerator and wine cellar. It is required to develop a multi type refrigerator combining these refrigerators to save space and energy consumption. In this study, the performance of a multi type refrigerator, which consists of one machine room and three evaporators, was measured in a bench type multi refrigerator. The multi type refrigerator was tested by varying the number of refrigerator cabinet, refrigerant charge, and temperature conditions. In addition, the multi type refrigerator with a suction line heat exchanger(SLHX) was tested to improve system performance. Based on the experimental data, the multi type refrigerator showed better performance than the conventional refrigerator(single type system). Besides, the COP of the single system increased from 1.0 to 1.37, and those of the dual and triple system increased from 1.29 to 1.39, and 1.22 to 1.51, respectively, by applying the SLHX.

The Effects of Chronic Ankle Instability on Postural Control during Forward Jump Landing (전방 점프 착지 시 만성 발목 불안정성이 자세 조절에 미치는 영향)

  • Kim, Kew-wan;Jeon, Kyoungkyu;Park, Seokwoo;Ahn, Seji
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.1
    • /
    • pp.9-16
    • /
    • 2022
  • Objective: The purpose of this study was to investigate how the chronic ankle instability affects postural control during forward jump landing. Method: 20 women with chronic ankle instability (age: 21.7 ± 1.6 yrs, height: 162.1 ± 3.7 cm, weight: 52.2 ± 5.8 kg) and 20 healthy adult women (age: 21.8 ± 1.6 yrs, height: 161.9 ± 4.4 cm, weight: 52.9 ± 7.2 kg) participated in this study. For the forward jump participants were instructed to stand on two legs at a distance of 40% of their body height from the center of force plate. Participants were jump forward over a 15 cm hurdle to the force plate and land on their non-dominant or affected leg. Kinetic and kinematic data were obtained using 8 motion capture cameras and 1 force plates and joint angle, vertical ground reaction force and center of pressure. All statistical analyses were using SPSS 25.0 program. The differences in variables between the two groups were compared through an independent sample t-test, and the significance level was to p < .05. Results: In the hip and knee joint angle, the CAI group showed a smaller flexion angle than the control group, and the knee joint valgus angle was significantly larger. In the case of ankle joint, the CAI group showed a large inversion angle at all events. In the kinetic variables, the vGRF was significantly greater in the CAI group than control group at IC and mGRF. In COP Y, the CAI group showed a lateral shifted center of pressure. Conclusion: Our results indicated that chronic ankle instability decreases the flexion angle of the hip and knee joint, increases the valgus angle of the knee joint, and increases the inversion angle of the ankle joint during landing. In addition, an increase in the maximum vertical ground reaction force and a lateral shifted center of pressure were observed. This suggests that chronic ankle instability increases the risk of non-contact knee injury as well as the risk of lateral ankle sprain during forward jump landing.

Analysis of demonstration research on solar heat pump system for room and hot water heating in the southern part of South Korea (남부지역의 태양열이용 열펌프식 온수.난방시스템의 실증연구 분석)

  • Sun, Kyung Ho;Kim, Ki Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.198.1-198.1
    • /
    • 2010
  • The goal of this study is to measure and compare the performance of solar heat pump for room and hot water heating. To accomplish the goal, solar heat pump with alumium roll bond type evaporator and indoor heat exchanger(condenser) was built and fully instrumented with thermocouples and pressure transducers etc. The test results showed that the COP(coefficient of performance) of HFC-134a($CF_3CH_2F$) were higher than those of CFC-12($CF_2Cl_2$). One "stratospherically safe" new refrigerant is 1,1,1,2-tetrafluoroethane(HFC-134a), which is thermodynamically similar to CFC-12 and considered to be a potential direct replacement for CFC-12 in air-conditioning and refrigeration applications. The solar heat pump system for room heating was designed to show the best efficiency that the room temperature make $18{\sim}20^{\circ}C$ and $23{\sim}25^{\circ}C$ in the southern part of South Korea during November, December, and January.

  • PDF

Pre-Analysis Study on Ground Source Heat Pump System in Building with RETScreen (RETScreen을 활용한 건물에서의 지열 히트펌프 시스템 적용 사전 분석연구)

  • Kim, Yu Jin;Lee, Kwang-Seob;Lee, Euy-Joon;Kang, Eun-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.2
    • /
    • pp.1-10
    • /
    • 2020
  • Korea government published renewable energy obligation policy that public building must be supplied some part of total consumption energy (2019: 27%, 2020: 30%). RETScreen is freely available global energy tool that developed by Canadian National Energy Laboratory to quantify energy saving to compare conventional system. This program can be performed energy modeling, cost analysis, greenhouse gas emission analysis and financial analysis. In this study, GSHP (Ground source heat pump) heating and cooling system were studied for the energy deliverly and ROI (Return On Investment) in an office building. Three cases were studied according to the number of HP (Heat pump) units for the 1,000㎡ office building located in Daejeon. Results indicated that the energy delivery of the case 1 (1 HP unit) covered 57% of the office building heating and cooling energy consumption. The case 2 (2 HP units) covered 87.8% and the case 3 (3 HP units) covered 96.8% of the office building energy consumption. The ROI of the case 1 indicated 7.9 years. While 8.2 years for the case 2 and 9.7 years for the case 3.

Heat Exchanger Design of a Heat Pump System Using the Heated Effluent of Thermal Power Generation Plant as a Heat Source for Greenhouse Heating (화력발전소의 온배수를 열원으로 이용하는 시설원예 난방용 히트펌프 시스템의 열교환기 설계기준 설정)

  • Ryou, Young Sun;Kang, Youn Ku;Jang, Jae Kyung;Kim, Young Hwa;Kim, Jong Goo;Kang, Geum Chun
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.372-378
    • /
    • 2012
  • This study was carried out in order to determine the optimum length of a roll type PE pipe heat exchanger employed in the water-to-water heat pump system using the waste heat of the heated effluent flowed out from thermal power generation plants as a heat source. And the heat pump system of 30 RT for an experimental test was designed and manufactured. And also PE pipes were employed to recover the waste heat from the heated effluent. The inside diameter of PE pipe heat exchanger was 20 mm, the thickness was 2 mm and the diameter of a roll was 1,000 mm. And from the results of this study, we found that the optimum length of PE pipe heat exchanger was 75 m per the heat pump capacity of 1.0 RT (3.51 kW) and then the heating COP of heat pump system was 3.8.

Effect of Treadmill Training with Ankle Joint Taping on Gait Function and Balance Ability in Patients with Subacute Stroke: A Randomized, Controlled, Preliminary Trial

  • Gill, Yeong-Jin;Oh, Se-Jung;Cha, Yong-Jun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.1
    • /
    • pp.21-30
    • /
    • 2022
  • PURPOSE: This study examined the effects of treadmill training with taping on the affected ankle joint on the gait and balancing ability in patients with sub-acute stroke. METHODS: Nineteen patients with sub-acute hemiplegic stroke in a rehabilitation hospital were assigned randomly to either the experimental group (n = 10), who received treadmill training with taping on the affected ankle joint or the control group (n = 9), who received general treadmill training. All participants performed 60 min of comprehensive rehabilitation therapy (five sessions per week for four weeks). Each group received treadmill training with or without taping on the affected ankle joint for 20 min (three sessions per week for four weeks). The gait and balancing ability were measured before and after the four-week training. RESULTS: Post-training scores of 10-meter walk test (10 MWT), timed up and go (TUG) test, and center of pressure (COP) path length and velocity for the experimental group increased significantly compared to that pre-training (p < .05). The experimental group showed a larger decrease in the 10 MWT and TUG test than the control group (-3.5 s vs. -1.01 s, p < .05; -4.9 s vs. -1.7 s, p < .05; respectively) CONCLUSION: Treadmill training with taping on the affected ankle joint might improve the gait and balancing ability of stroke patients and is considered a more effective method for improving gait and balancing ability than the method of general treadmill training.

Analyses of Patterns of Spins with Insole Foot-Pressure Distribution during a Figure Skating (Flying Sit Spin과 Flying Camel Spin 시 규정자세에 따른 족저압력패턴의 연구)

  • Yoo, Kyoung-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.159-168
    • /
    • 2008
  • The purpose of this study was to analyze the variables of plantar pressure distribution, the COG between Flying Sit Spin(FSS) and Flying Camel Spin(FCS) during a Figure Skating. In order to investigate the two types of spin mechanism in the Korea national of elite women Figure skaters(N=4), this study investigated the phase time, CA(contact area), MF(maximum force) Mean Force, and PP(peak pressure) Mean Force. The data was collected using PEDAR Mobile System which is the pressure distribution measuring devices. The obtained conclusions were as follow: During the two types of spins(FSS and FCS), the FCS is higher than the FSS on the MF(20%BW), PP(20%BW) variables during P4 phase, but the FSS is larger than the FCS in the CA, MF, and PP during P1, P2, P3 phase. Consequently, depend on the COP and the COG locations about the vertical ground reaction vector, the FCS comparatively excelled control of speed feedback than the FSS in the P4 phase.