• Title/Summary/Keyword: CODcr and TOC

Search Result 7, Processing Time 0.025 seconds

Characterization of Humic Acid and its Variation after Ozonation (부식산의 흡광도, COD, TOC, 분자크기분포 및 오존처리에 따른 특성변화)

  • Rhee, Dong-Seok;Kim, Myung-Cheol
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.297-303
    • /
    • 1997
  • This study investigates the characteristics of humic acid before and after ozonation. The results were comapred in such terms as CODCr, CODMn, TOC(total organic carbon) and molecular size distribution. As a result of ozonation (with the dose of 3mgO3/mgHumic Acid), UV NIS absorbance, CODCr, CODMn and TOC were decreased with similar tendency. The mole fraction of high molecular size was rapidly decreased and the fraction ratio of low molecular size was increased through ozone treatment. This fact can be correlated with the change in the difference and the ratio of CODCr and CODMn (the value of CODCr-CODMn and CODMn/CODCr). From this result, it can be inferred that the molecular size and the degree of chemical oxidative degradation of humic acid after ozonation were changed.

  • PDF

Effect of chemical treatment and variations of the physical properties of waste water-soluble cutting oil (폐 수용성 절삭유의 화학처리효과 및 물성변화)

  • Sin, Chun Hwan;Jang, Jeong Guk
    • Journal of Environmental Science International
    • /
    • v.13 no.4
    • /
    • pp.403-412
    • /
    • 2004
  • Waste water-soluble cutting oil was treated with WI type #1 and WI type #2. The properties of the original water-soluble cutting oil were pH=l0.4, viscosity=1.4cP, CODcr=44,750 ppm, and TOC=10,569 ppm. However, the properties of the oil used for more than 3 months were changed to pH=7.82, viscosity=2.1cP, CODcr=151,000 ppm, and TOC=74,556 ppm. It might be attributed to the fact that molecular chains were cut due to thermal oxidation and impurities such as metal chips were incorporated in to the oil during the operation processes. To prevent the putrefaction of oil, the sterilization effect of ozone and UV on the microorganism in the oil was investigated. Ozone treatment showed that 99.99% of the microorganism was annihilated with 30 minutes contact time and 60 minutes were necessary for the same effect when UV was used. Ozone treatment could cut molecular chains of the oil due to strong sterilization power, which was evidenced by the increase of TOC from 25,132 ppm at instantaneous contact to 28,888 ppm at 30 minutes contact time. However, UV treatment didn't show severe changes in TOC values and thus, seemed to cause of severe cut of molecular chains. When the activated carbon was used to treat the waste water-soluble cutting oil, TOC decreased to 25,417 ppm with 0.lg carbon and to 15,946 ppm with 5.0g carbon. This results indicated that the waste oil of small molecular chains could be eliminated by adsorption. From the results, it could be concluded that these treatment techniques could be proposed to remove the waste oil of small molecular chains resulting in the degradation of the oil properties. In addition, these experimental results could be used for the correlation with future works such as investigation of the molecular distribution according to the sizes, lengths, and molecular weight of the chains.

Correlation analysis between TOC and organic matter indices in influent and effluent of public sewage treatment facilities (공공하수처리시설 유입수 및 방류수에서 TOC와 유기물질 관리지표간의 상관성 분석)

  • Son, Dong-Jin;Jeong, Dong-Hwan;Park, Kyoo-Hong
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.4
    • /
    • pp.122-129
    • /
    • 2021
  • As the total organic carbon (TOC) becomes a new water quality standard as an organic matter (OM) index for public sewage treatment facilities (PSTFs) in Korea from 2021, a comparison study needs to be conducted by examining the correlation between TOC and the existing OM indices (DOC, BOD5, CODMn, CODCr). 500 PSTFs were categorized by process configuration and capacity, and correlation between OM indices in influent and effluent was analyzed. The CODMn/TOC showed higher correlation than other OM indices. This results can be used to basic data for various research associated with TOC.

Cleaner Production System in Dyeing & Finishing Its Approaching Mehods (염색가공분야에서 청정생산활동 접금방법)

  • Lee, Hae-Jung;Nam, Chang-Woo;Park, Young-Hwan
    • Clean Technology
    • /
    • v.9 no.2
    • /
    • pp.87-100
    • /
    • 2003
  • The aim of study was to suggest a methodology for applying cleaner production technology in dyeing & finishing process of textile materials. To accomplish cleaner production, we performed consulting activity in dyeing factory, which composed of following different procedures. First, we organized consulting team with specialists for dyeing, energy and chemicals, and visited dyeing companies for the purpose of doing basic investigation such as analysis of process, chemicals & effluents, condition of equipment and process flow of products. Environmental aspect of raw materials (dyestuff, chemicals) was assessed by TOC, COD, BOD, and effluent of that was assessed by TOC, COD, BOD, TDS and pH. Second, We find out the problems in dyeing&finishing process from the view point of dyeing process, energy, raw materials and process management by utilizing MB (material balance), LCA(Life Cycle Assessment), EB(Energy Balance). Third, we generated the solutions to achieve optimal process condition by brain storming method, and then implemented the solutions to each process. Finally, we determined their effectiveness after considering the results of repeating trials for the solutions. Cleaner production could be achieved by keeping optimal process conditions, equipment modification, improved production management, and on-site reuse or recycling.

  • PDF

Characteristics of distribution and decomposition of organic matters in stream water and sewage effluent (하천수와 하수처리장 방류수의 유기물 분포 및 분해 특성)

  • Seo, Hee-Jeong;Kang, Yeoung-Ju;Min, Kyoung-Woo;Lee, Kyoung-Seog;Seo, Gwang-Yeob;Kim, Seung-Ho;Paik, Kye-Jin;Kim, Seong-Jun
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.36-44
    • /
    • 2010
  • This study was performed to investigate the distribution and decomposition characteristics of organic matter in stream water and sewage effluent located in Gwangju. Average of dissolved organic carbon (DOC) to total organic carbon (TOC) ratio was approximately 73.9% in the Youngsan river system. The concentration of refractory dossolved carbon (RDOC) was 3.7 mg/L corresponding to 80.9% of the DOC. The ratio of recalcitrant organic carbon was relatively higher than that of biodegradable organic carbon in stream. Oxidation efficiencies in the stream were 45.0% for BOD, 63.0% for $COD_{Mn}$ and 106.5% for CODcr. In case of sewage effluent was 33.6%, 65.7% and 136.1% respectively. Mean decomposition rate ($K_d$) of Youngsan river mainstream, its tributary sites and sewage effluent were about $0.042\;day^{-1}$, $0.043\;day^{-1}$ and $0.028\;day^{-1}$, respectively and the difference was not significant between the mainstream and its tributary sites (t-test, p>0.05). $K_d$ of the sewage effluent was lower than that of stream water.

A Study on the Effects of Retardation with Pb in the Biofilter (생물여과층에 의한 납의 이동억제효과에 관한 연구)

  • 이문현;이재영;최상일
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.2
    • /
    • pp.99-105
    • /
    • 2000
  • The purpose of this study was to show the application of the Biofilter for treatment of the soil contaminated by lead and to investigates the effect of the biofilter on the retardation of lead with pilotplants that were simulated with different media and the number of bed. and to testify the inoculation by seeding microbes. The ratio of the degradation of soil contaminant was verified as CODcr/TOC in order to find a variation of the stabilization index in soil. The Biofiltration was one of biological processing methods for treatment. The contaminants were transported through the biofilter that was filled with the media. The surface of media formed biofilm which was surrounded by microbes and through its boundary, some materials were exchanged and migrated into the cell of microbes in an orderly manner. To investigate the effect of the Biofiltration, contaminated soil with lead nitrate of 1000mg/kg in dry was made artificially. The tests were simulated such as compost, Bioceramic and compost with bioceramic by 7:3 in weight. The bed consisted of three layers in order to find effect of the number of bed. Aspergillus niger was used as a biosorbent could probe the effect on the retardation of lead.

  • PDF

A Study on the Pretreatment Process for Sewage Reuse by Microfiltration Process (정밀여과에 의한 하수고도처리수의 재이용을 위한 전처리법에 관한 연구)

  • Kuk, Young-Long;Joo, Jae-Young;Bae, Yoon-Sun;Lee, Hye-In;Jung, In-Ho;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.595-601
    • /
    • 2010
  • It is evident that Korea will continue its battle with water shortage and alternative program are being taken into action. One of the main actions is reusing 1,800 tons of effluent of 357 sewage treatment plant located nationwide. Therefore this study supplemented ozone oxidation methods that would increase the efficiency of organic oxidation and coagulation. Through this method, fouling will be controled sufficiently by preventing membrane process in the system for advanced sewage treatment. In this study, ozone-coagulation-microfiltration membrane were used. The final removal efficiency of the pretreated water from the result of the ozone-coagulation were 50% of CODcr, 38% of TP and 11% of TOC respectively. Water quality treatment has decreased about 80% for TP. Ozone-coagulation-microfiltration membrane maintains the high flux while decreasing the number of organic matter and the membrane fouling, and reducing the TP. As a result, in order to reuse the water from the sewage, the ozone-coagulation-microfiltration membrane type must be considered in order to achieve the best efficiency.