• Title/Summary/Keyword: COD Test

Search Result 297, Processing Time 0.024 seconds

New Engineering Estimation Method of J-Integral and COD for Circumferential Through-Wall Cracked Pipes (원주방향 관통균열이 존재하는 배관의 J-적분 및 COD 계산을 위한 새로운 공학적 계산식)

  • Kim, Yun-Jae;Heo, Nam-Su;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.3
    • /
    • pp.548-553
    • /
    • 2001
  • A new method to estimate the elastic-plastic J-integral and the crack tip opening displacement (COD) for circumferential through-wall cracked pipes under tension and under bending is proposed for Leak-Before-Break (LBB) analysis. Being based on the reference stress method with further modifications, the proposed method is simple to use and easy to be generalised in practice. Comparison of the CODs, predicted using the proposed method with published pipe test data show overall excellent agreement.

An Electrolytic Treatment of Shipboard Sewage by Using DSA Electrode(II) -Continuous Electrolytic Treatment- (DSA 전극에 의한 선박오폐수의 전해처리(II))

  • 김인수;조권희;남청도
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.3 no.2
    • /
    • pp.77-84
    • /
    • 1997
  • For the effective treatment of shipboard sewage continuously, a non-diaphragm electrolytic treatment device using DSA type insoluble electrode, Ti/IrO2, anode and H-C metal cathode, was studied. The most effective electrolytic conditions were obtained when cell clearance, 6mm, pH 5-6 and the concentration of seawater, more than 20% as batch test results. The COD removal rate was varied in logarithmic function, showed as C=Coe-KE and the required current was E = A/QCo [A.min/mgCOD]. When the COD removal effeciency was more than 90%, the electrolytic reaction constant was 0.02.

  • PDF

Respirometry for the Assessment of Organics Biodegradability in Municipal Wastewater: I. Respirometry (호흡률법에 의한 하수의 생분해 특성 평가: I. 호흡률법)

  • Kim, Dong Han;Kim, Hee Jun;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.1
    • /
    • pp.29-36
    • /
    • 2004
  • Organics may be divided into biodegradable and nonbiodegradable fractions on the basis of biodegradability. Biodegradable organics may be subdivided into readily and slowly biodegradable fractions. As this biodegradability of organics in municipal wastewater has a great influence on the efficiency of a biological nutrient removal process, it has been assessed by respirometry. The respirometer, which consisted of a respiration chamber and a respiration cell, was used to measure the respiration rate of biomass utilizing the readily biodegradable organics. The readily biodegradable organics are about 10% of the COD in municipal wastewater. The adequate ratio of wastewater to sludge volume and the concentration of sludge are required in measuring the respiration rate due to the readily biodegradable organics. By using a biochemical oxygen demand test, the slowly biodegradable organics including biomass are estimated about 66% of COD. The soluble inert organics are about 11% of COD. On the basis of mass balance, the particulate inert organics are estimated about 13% of COD.

Fenton난s Reagent Oxidation of Refractory Organics in Petrochemical Plant Effluent (석유화학공장 방류수내 난분해성 유기물의 Fenton 산화처리)

  • Lee, Kyu-Hoon;Jung, Dae-Young;Park, Tae-Joo
    • Journal of Environmental Science International
    • /
    • v.5 no.1
    • /
    • pp.51-59
    • /
    • 1996
  • The purpose of this study was to evaluate the partial oxidation of the biological treatment plant effluents using Fenton's reagent as a pretreatment step prior to a tertiary biological oxidation of these effluents. Fenton's reagent was evaluated as a pretreatment process for inhibitory or refractory organics. Based on the Fenton oxidation system, the petrochemical wastewater treatment plant effluent was shown to have significant improvement in toxicity after oxidation with hydrogen peroxide. For example, at ranee of 42 ∼ 184 mg/L COD of petrochemical plant effluents, the COD removal efficiencies were from 38.2% to 60.1% after reaction with hydrogen peroxide 200 mg/L and Fe2+ 100 mg/L and reaction time was 30 minutes. The total TOC reduction were about 15.8∼22.4% with same test condition and difference between the overall removal rate and BOD/COD ratio after Fenton's oxidation estabilished in the biodegradation and otherwise meets the discharge standard or reuse for cooling tower make-up water.

  • PDF

Trend Analysis of the COD and Nutrients Concentrations in the Yongwon Channel, Chinhae (진해 용원수로의 COD 및 영양염류 농도 추세분석)

  • Cho, Hong-Yeon;Chae, Jang-Won;Park, Joung-Guy;Koo, Myung-Seo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.4
    • /
    • pp.421-428
    • /
    • 2008
  • Youngwon channel located in Chinhae city and formed by the Busan New Port Construction Project has been concerned about the water quality degradation problems because of the flow and pollutants stagnation due to its long-narrow shape. In this study, the water quality(hereafter WQ) variation is analysed by using the monthly WQ data measured in Yongwon channel from 2003 to 2007. The analysis shows that the TN and TP concentration in the inside Yongwon channel is definitely worse than the TN and TP concentration in the entrance of the Yongwon channel based on the 95% confidence level. The COD, TN, and TP concentrations in the Yongwon channel are 1.34, 2.08, and 1.80 times larger than that in the entrance of the Yongwon channel, respectively. It has been found that only the TP concentration in SW-26 station has an increasing trend based on the Mann-Kendall test with respect to 95% confidence level. The other stations and the other WQ constituent changes do not have the any significant trends.

Assessment of Characteristics and Field Applicability with TPA By-Product as Alternative External Carbon Source (대체 외부탄소원으로서의 TPA 생산부산물 특성 및 현장적용성 평가)

  • Jung, In-Chul;Jun, Sung-Gyu;Sung, Nak-Chang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.5
    • /
    • pp.480-486
    • /
    • 2006
  • On account of exchanging main process from chemical precipitation for MLE(Modified Ludzark-Ettinger), an external carbon source was required for supplementation of carbon source shortage that was needed biological denitrification in the S sewage treatment plant(S-STP). In this study, NUR(nitrate uptake rate), OUR(oxygen uptake rate) test and a field application test was conducted for the applicability assessment of Terephtalic acid(TPA) by-product contained about 4.7% acetate as alternative external carbon source. As the results, TPA by-product shows more rapid acclimation than methanol, 8.24 mg ${NO_3}^--N/g$ VSS/hr specific denitrification rate, 3.70 g $COD_{Cr}/g\;NO_3$ C/N ratio and 99.4% readily biodegradable COD contents. In the results of field application, the nutrient removal efficiency was high and effluent T-N concentration is 8.2 mg/L. It is concluded that TPA by-product is the proper alternative external carbon source.

Identification of Critical Source Areas on Water Quality in a Rural Watershed (하천수질자료를 이용한 농촌하천유역 오염원의 규명)

  • Hong, Seong;Kwun, Soon Kuk
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.5
    • /
    • pp.145-152
    • /
    • 2001
  • 농촌유역하천에서 수집된 수질측정자료를 이용하여 주요 오염원을 규명하였다. 분석에 이용된 수질항목은 BOD, COD. EC, pH. TN, TP,$NO_3-N,PO_4-P$ 등으로서 하천 본류내 구간별로 쌍대비교를 통해서 항목별 차이에 대한 유의성 검정을 하였다. 유의성 검정에 이용된 방법은 쌍대비교를 위한 비모수검정법인 Wilcoxon 순위검정법을 이용하였다. 검정결과, 유기성 오염물질의 지표로 이용되는 BOD와 COD가 상승하는 구간은 주로 생활하수가 유입되는 구간으로 나타났다. 인구밀도가 매우 높으나 생활하수가 처리장으로 배제되는 지역의 하천구간에서는 이들 농도변화는 없었다. 유역 내 축산농가가 밀집되어 있는 지역의 하천구간에서도 농도의 변화 또한 존재하지 않았다. 본 연구에서 조사된 유역에서와 같이 축산분뇨를 퇴비화 및 농지환원하는 경우에는 하천수질에 거의 영향을 미치지 않는다는 것을 알 수 있었다. 따라서 농촌지역의 하천 수질을 개선하기 위해서는 생활하수에 대한 처리가 선행되어야 한다.

  • PDF

Test-bed evaluation of developed small constructed wetland for using in urban areas (도시지역에 적용하기 위한 소규모 인공습지 Test-bed 시설 평가)

  • Kang, Chang-Guk;Lee, So-Young;Cho, Hye-Jin;Lee, Yuw-Ha;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.455-463
    • /
    • 2011
  • Conventional construction technologies have been continually applied without consideration of its impact to the environment. This resulted to various problems including the negative responses of local citizens that regarded some constructed facilities as aversive facilities causing environmental and hydraulic problems in the urban area, etc. To prevent these problems, therefore, alternative methods should be undertaken. A new approach termed "Low Impact Development (LID)" technology is currently adapted in developed countries around the world. This study aims to investigate the efficiency of the developed small constructed wetland (SCW) with horizontal subsurface flow as a LID technique applicable in urban areas. Two test-bed facilities were constructed and monitoring had been conducted between July 2010 and June 2011. Based on the findings, the removal efficiencies achieved for TSS, $COD_{Cr}$, TN, TP, Total Fe, Total Pb for the SCW-1 were 66, 53, 46, 55, 67 and 50%, respectively. On the other hand, the SCW-2 attained 82, 62, 51, 48, 74 and 42% efficiency for TSS, $COD_{Cr}$, TN, TP, Total Fe, Total Pb, respectively. The results indicated that the removal of particulate matter and heavy metals which are considered as main pollutants from stormwater runoff in urban areas was satisfactory in the system. Therefore, the test-beds proved to be appropriate for the treatment of pollutants in urban landuses such as road, parking lot, etc. The results of this study can contribute to the conservation of aquatic ecosystems and restoration of natural water cycle in the urban areas.

Evaluation of Pollutant Removal Efficiency through Field Test-Bed Experiment in the Rural Small Stream (저수지 유입하천 현장적용실험을 통한 수질정화효율 평가)

  • Choi, Sun Hwa;Oh, Jong Min;Kim, Tae-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.12
    • /
    • pp.1135-1143
    • /
    • 2014
  • This study was carry out to evaluate of water purification in oxidation pond with filamentous algae mat. It is the water treatment process in the small rural streams to remove the organic materials and nutrients. We used the filamentous algae mat (FAM) which selectively predominate the filamentous algae to prevent the additional contamination by algae outflow, and we conducted a experiment on the water treatment process using the aquatic plants such as Eichhornia crassipes. The removal efficiencies (%) of water quality parameters were SS 80.9%, COD 74.6%, TN 76.8%, TP 84.4%, DTN 93.8% and DTP 98.3%, respectively. Temperature, a effect factor, was $21.8{\pm}5.9^{\circ}C$ during the operating period, according to temperature had no effect on the removal efficiencies of pollutants. Hydraulic retention time (HRT) strongly correlated with removal efficiencies (%) of SS and TP having r=0.414 (p<0.005), r=0.446 (p<0.005), respectively, and when HRT was 5day had highly removal efficiency (%) in SS and TP. TN and TP removal efficiency increased with ratio decreasing in both COD/TN and COD/TP of Influent.

Long-term Changes of Physicochemical Water Quality in Lake Youngrang, Korea

  • Bhattrai, Bal Dev;Kwak, Sungjin;Choi, Kwansoon;Heo, Woomyung
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.1
    • /
    • pp.169-185
    • /
    • 2017
  • Physicochemical properties of water quality were analyzed to understand the long-term variations in Lake Youngrang from 1998 to 2015. Nonparametric statistical methods were applied to deduct correlation among water quality parameters and water quality trend. In total observations(N=64), the Secchi depth (SD) transparency showed significant positive correlation with salinity (r=0.458) and highly significant negative correlation with chlorophyll-a (r= -0.649) for p<0.0001 in two-tailed test of Spearman's rank correlation. Significant negative correlations of SD were observed with chemical oxygen demand (COD), total phosphorus (TP) and total nitrogen (TN). These correlation patterns were very similar in rainy (N=25) and non-rainy (N=39) periods too. Chlorophyll-a (Chl-a) had significant correlation with COD. Sen's slope test was performed along with Mann-Kendall trend test (significance ${\alpha}=0.05$, two-tailed) to find water quality trend. Positive trends were observed for SD and salinity with Sen's slopes 0.012 and 0.385, respectively (p<0.0001). Negative significant trends were observed for total nitrogen (TN) and Chl-a with Sen's slopes -0.02 (p<0.0001) and -0.346 (p=0.0010), respectively. Temperature, COD and phosphorus components had no trends. Carlson's trophic state index (TSI) for SD, TP and Chl-a were obtained in the ranges of 46~80, 37~82 and 39~82, respectively. Trophic index values suggest that Lake Youngrang was mesoeutrophic to eutrophic and there could be possibility of anoxia during the summer and dominance of blue-green algae. Excess nutrient inputs from external and internal sources were the causes of eutrophication in this lake. The findings of this study would be helpful to recognize water quality variables to manage the water body.