• 제목/요약/키워드: COD Test

검색결과 297건 처리시간 0.028초

온천천 하류 적조 원인생물의 동정 및 발생 특성 (Identification of Red Tide-causing Organism and Characteristics of Red Tide Occurrence in the Oncheon Down Stream, Busan)

  • 김미희;지화성;조정구;조순자
    • 한국물환경학회지
    • /
    • 제34권3호
    • /
    • pp.285-292
    • /
    • 2018
  • This study was performed in order to identify the red tide-causing organism and to understand the characteristics of the water quality during the winter of 2015 and 2016 in the Oncheon stream, a tidal river in Busan, where red tide often occurs in the wintertime. Two sites were selected on the stream and the surface water was sampled a total of 28 times during the experimental period. Twelve water quality characteristics, including water temperature, pH, DO, COD, total-N (T-N), total-P (T-P), and salinity were analyzed in order to test water quality. The cell numbers of cryptomonads were counted directly by microscopic observation. The nucleotide sequences of the partial 28S rRNA gene and psbA gene from metagenomic DNA, derived from each sampling site, were analyzed. According to the results, the alga most responsible for the bloom was identified as Teleaulax OC1 sp., which belongs to the cryptomonads. Three items of chl-a, pH, and DO were positively correlated with the cell numbers of the cryptomonads counted at the upper stream of the tidal area (St 1) while eight items of chl-a, TOC, BOD, total-N, COD, SS, pH, and DO were positively correlated with the cells located at the junction between the stream and Su-young river (St 2) in the order.

박테리아를 흡착한 팽창질석 기반의 친생태 모르타르 개발 (Compressive Strength and Ecological Characteristics of Mortars Using Expanded Vermiculite Absorbing Bacteria)

  • 윤현섭;정승배;양근혁;이상섭;이재영
    • 한국건설순환자원학회논문집
    • /
    • 제4권2호
    • /
    • pp.165-171
    • /
    • 2016
  • 본 연구에서는 에코 프리캐스트 콘크리트 제품 개발을 위한 기초 연구로서 박테리아를 흡착한 팽창질석 기반의 친생태 모르타르를 개발하였으며, 압축강도 발현 및 생태환경영향 평가를 실시하였다. 경화된 모르타르의 극건조 환경 및 강알칼리성 환경에서 생장이 가능하며, 식물생장성 증대 효과를 갖는 Bacillus alcalophilus와 Rhodoblastus acidophilus를 분리 및 배양하였다. 배양이 완료된 박테리아는 생장처 제공을 위한 재료로서 선택된 팽창질석에 흡착하였으며, 이를 배합시 골재의 체적 대비 혼입하여 모르타르를 제작하였다. 평가 결과 친생태 모르타르는 COD 및 T-N 수질정화능력 및 식물생장증대에 효과를 보였다. 모르타르의 압축강도 발현 및 비용적 측면을 고려했을 때, 박테리아 기반 팽창질석의 최적 치환율은 최대 10% 이하가 추천될 수 있었다.

유용미생물을 이용한 콘크리트의 수질정화특성에 관한 실험적 연구 (An Experimental Study on Water-Purification Properties of Concrete Using Effective Micro-Organisms)

  • 서대석;전진용;김정환;권혁준;박승범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.757-760
    • /
    • 2008
  • 오늘날 산업의 발달과 함께 생활수준이 향상됨에 따라 삶의 질을 향상시키기 위한 안락하고 편안한 주거환경의 확보와 함께 주거환경주변에서 발생하는 각종오염문제의 해결에 관해서도 그 관심이 집중되고 있다. 그러나 최근 새집증후군 등 콘크리트제품에 대한 환경적인 안정성에 대한 논란이 심화되면서 콘크리트 경화시 발생하는 각종 물질들의 처리에 대하여 본 연구에서는 오염된물의 처리, 하수슬러지 및 오염된 토양의 중금속 및 악취제거에 사용되는 유용미생물을 콘크리트에 적용을 통하여 하천, 호수 등 각종 수변부에 적용되는 구조물에의 적용 가능성을 알아보기 위하여 유용미생물의 사용 유무에 따른 콘크리트의 수질정화성능(SS, BOD, COD, T-P, T-N)을 측정하였다. 유용미생물을 이용한 콘크리트의 수질정화 시험결과 각각의 제거율은 유용미생물이 함유된 콘크리트 블록의 경우가 일반콘크리트 블록에 비해 오염물질 제거율이 전체적으로 약 10% 정도 높게 나타나 유용미생물의 작용에 의하여 수질정화에 효과가 있는 것으로 사료된다.

  • PDF

Degradation of toxic azo dye (AO7) using Fenton's process

  • Sharma, Ashish;Verma, Manisha;Haritash, A.K.
    • Advances in environmental research
    • /
    • 제5권3호
    • /
    • pp.189-200
    • /
    • 2016
  • This study aimed at advanced oxidation of hetero tri-functional reactive dye Acid orange 7 using photo-Fenton conditions in a lab-scale experiment. Decolourisation of Acid Orange 7 dye by Fenton's process was dependent on concentration of Hydrogen peroxide, Ferrous sulphate, pH, and contact time. A $2^3$ factorial design was used to evaluate the effects of these key factors: pH, Fe(II), and $H_2O_2$ concentration, for a dye concentration of 50 mg/L with COD of 340 mg/L at pH 3.0. The response function was removal of colour under optimised conditions; pH 3.0, [Fe(II)] 40.83 mg/L, [$H_2O_2$] 4.97 mmol/L; 13.6 min. of treatment resulting in 100% colour removal. The final COD of treated wastewater was nil suggesting that AOP is a potentially useful process of color removal and dye degradation/mineralisation of effluent having AO7. Minimum contact time for complete decolourisation was at 5 mmol/l $H_2O_2$ concentration. Increase in $FeSO_4$ (mg/l) concentration resulted in decrease of time for complete decolourisation. Box-Behnken Design was used to optimize the process variables. Maximum and minimum levels of pH (3-5), $H_2O_2$ (4-6 mmol/l), $FeSO_4$ (30-46 mg/l) and contact time (5-15 minutes) were used. The statistical analysis revealed a value of 0.88 for coefficient of regression ($R^2$) indicating a good fit of model. Calculated F-value was found higher than the tabulated value confirming to significance of the model. Based on student's t-test, Ferrous sulphate, pH, and contact time have a positive effect on the percent decolourisation of Acid Orange 7.

침지형 막분리 활성 슬러지법에 따른 막 오염 특성 (Characteristics of Fouling in a Submerged Membrane Bioreactor Activated Sludge Process)

  • 김대식;강종석;김기연;이영무
    • 멤브레인
    • /
    • 제11권4호
    • /
    • pp.170-178
    • /
    • 2001
  • 상전환 방법에 의해 PVC계 MF막을 제조하여 환성슬러지가 포함된 폐수 처리용 MBR (Membrane bioreactor)에 적용하였다. 막 제조시 첨가제의 농도에 따른 막 특성을 확인한 결과 첨가제의 농도가 증가할수록 기공 크기가 증가하였으며 친수화도 역시 향상되었다. MBR의 내부 환경변화에 따른 실험을 통해 제조한 막의 투과 성능 및 막에 발생하는 막 오염 거동을 조사하였다. 사상균의 생성으로 인한 Sludge bulking 시 막 오염 현상이 가속화되었으며, 이 때 각 시료의 Rc을 조사한 결과 CP-0 > CP-1.0 > CP-1.5의 순으로 나타났고, 정상상태와 비교하여 sludge busking시 Rc값은 3.5~7배가지 증가하였다. 표면 특성이나 투과 유속면에서 PVP 1.5 wt% (CP-1.5)를 첨가하였을 때가 가장 적합하였다. 평균 투과 유속은 시료 모두에서 12(${\pm}$2) L/$m^2$hr 정도였으며, 평균 COD 제거율은 98.8% 정도를 나타내었다 MBR 운전에 있어 sludge bulking시 사상균이 차지하는 비율과 미생물의 모양과 크기에 따라 막 오염은 가속화 되었고, 투과 유속 감소를 보였다. 따라서 막 여과 특성은 막의 친수화 정도와 MBR 내부 미생물의 성장 조건과 환경에 의해 결정되는 것을 알 수 있었다.

  • PDF

하수 일차슬러지의 세정산발효 특성에 대한 Microwave 전처리의 영향 (Effects of Microwave Irradiation for Elutriated Acid Fermentation of Sewage Primary Sludge)

  • 권구호;이원식;민경석
    • 한국물환경학회지
    • /
    • 제23권4호
    • /
    • pp.498-503
    • /
    • 2007
  • The performance of elutriated acid fermentation to evaluate the effects of microwave irradiation and pH control as pretreatment was investigated. The MW pH 7 reactor which was used the pretreated primary sludge as microwave irradiation was operated at pH 7 and $35^{\circ}C$. The EAF pH 9 reactor was operated at pH 9 and $35^{\circ}C$ without pretreatment. The SCOD and VFAs production rate were 0.17 gSeOD/gVSrem. and 0.27 gVFAs as COD/gVSrem. in MW pH 7 reactor, 0.16 gSCOD/gVSrem. and 0.24 gVFAs as COD/gVSrem. in EAF pH 9 reactor, respectively. VS and Volume reduction were 54% and 48% in MW pH 7 reactor, 54.6% and 36% in EAF pH 9 reactor, respectively. A comparison of the microwave irradiation and controlled pH in elutriated acid fermentation showed that the former is more efficient in SCOD and VFAs production and it rises to slightly higher reduction in the volume of the sludge. In addition, E. coli. was not detected in the wasting sludge of MW pH 7 reactor. Based on the results, microwave irradiation appeared to be one of the viable options for generating class A sludge. According to the batch tests, sequencing batch test which was used the pretreated primary sludge as microwave was performed at pH 7 and $35^{\circ}C$, SCOD production was 0.16 gSCOD/gVSrem., VS reduction and volume reduction were 64% and 63%, respectively.

Cr-Mo 鋼 溶接熱影響部의 溶接後熱處理 脆化에 관한 硏究 (Study on PWHT embrittlement of weld HAZ in Cr-Mo steel)

  • 임재규;정세희
    • 대한기계학회논문집
    • /
    • 제11권2호
    • /
    • pp.314-321
    • /
    • 1987
  • 본 논문에서는 용접열영향부(heat affected zone: HAZ)의 인성에 영향을 미치 는 인자중에서 잔유응력의 영향은 중대한 문제로 주목되고 있으며, 이로 인한 용접재 의 기계적 성질의 저하를 경함하기 위한 방법으로 용접후열처리(post weld heat trea- tment: PWHT)에 의한 제거방법을 이용하고 있다.그러나 이 열처리는 보톤 600.deg. C 이 상의 고온에서 실현되기 때문에 열처리과정에서 템퍼링(tempering)효과로 인한 HAZ의 열화가 때때로 발생하고 있어서 용접 시공상 문제로 되고 있다. 또한 PWHT시에는 가 열중이나 냉각중에도 열처리효과가 진행되고 있다고 볼 수 있으므로, PWHT가열속도는 기계적 성질의 개선이라는 이유외에 경제적 측면에서도 중요시 된다. 특히 용접조직 의 포화는 파괴의 양식에 직접반영되어, 파면형태의 차로 나타나므로, 본 조직의 포화 와 관련시켜 검토하기 위하여 열처리된 HAZ를 대상으로 작용된 응력의 크기와 가열속 도가 HAZ의 파괴인성에 어떠한 영향을 미치는지를 COD파괴인성시험과 미소경도측정, 그리고 주사전자현미경관찰을 통하여 고찰하였다.

상하식과 그리드식 새우조망 어구의 전개성능과 선택성 (Opening efficiency and selectivity of Double-level type and Grid type in the shrimp beam trawl net)

  • 장충식;조윤형;안영수
    • 수산해양기술연구
    • /
    • 제50권3호
    • /
    • pp.351-360
    • /
    • 2014
  • The experiments were carried out to decide the selective fishing gear of the shrimp beam trawl fishery. The model nets were made of General type, Double-level type and Grid type. The model experiments were carried out to test opening efficiency and towing tension. The experimental tanks were the flume tank [$8.0L{\times}2.8W{\times}1.4H(m)$] and the towing tank [$85L{\times}10W{\times}3.5H(m)$] in National Fisheries Research and Development Institute. The full scale experiments were carried out to compare the selectivity of General type net, Double-level type net and Grid type net in the southern sea of korea. The vertical opening (net height) of the model nets can be expressed as a function of the towing velocity as the straight line. The towing tension of the model nets can be expressed as a function of the towing velocity as the parabola. The shrimp catching rates of upper cod end in Boryeong and tongyeong were 78%, 9% respectively, but the rates of lower cod end were 23%, 91% respectively. The number bycatch rates of General type and Grid type were 23%, 11% respectively, and the weight bycatch rates were 34%, 31% respectively. A selective shrimp beam trawl net is Grid type in korea coastal sea.

통계분석 및 수질지수를 이용한 남한강 하류 유역의 수질 평가 (Assessment of Water Quality in the Lower Reaches Namhan River by using Statistical Analysis and Water Quality Index (WQI))

  • 조용철;최현미;류인구;김상훈;신동석;유순주
    • 한국물환경학회지
    • /
    • 제37권2호
    • /
    • pp.114-127
    • /
    • 2021
  • Water pollution in the lower reaches of the Namhan River is getting worse due to drought and a decrease in water quantity due to climatic changes and hence is affecting the water quality of Paldang Lake. Accordingly, we have used a water quality index (WQI) and statistical analysis in this study to identify the characteristics of the water quality in the lower reaches of the Namhan River, the main causes of water pollution, and tributaries that need priority management. Typically, 10 items (WT, pH, EC, DO, BOD, COD, SS, T-N, T-P, and TOC) were used as the water quality factors for the statistical analysis, and the matrix of data was set as 324 × 10·1. The correlation analysis demonstrated a strong correlation between Chemical Oxygen Demand (COD) and T-P with a high statistical significance (r=0.700, p<0.01). Furthermore, the result of principal component analysis (PCA) revealed that the main factors affecting the change in water quality were T-P and organic substances introduced into the water by rainfall. Based on the Mann-Kendall test, a statistically significant increase in pH was observed in SH-1, DL, SH-2, CM, and BH, along with an increase in WQI in SH-2 and SM. BH was identified as a tributary that needs priority management in the lower reaches of the Namhan River, with a "Somewhat poor" (IV) grade in T-P, "Fair" grade in WQI, and "Marginal" grade in summer.

하수슬러지를 이용한 Bio-block의 비점오염물질 제거 가능성 평가 (Evaluation of the Feasibility of Eliminating Non-point Source Pollution Using Waste Sewage Sludge Bio-blocks)

  • 한상무;김도형;정병곤
    • 한국물환경학회지
    • /
    • 제37권5호
    • /
    • pp.363-368
    • /
    • 2021
  • On the assessment results of the non-point source pollutant removability of bio-block using waste sewage sludge, at the reactor's initial operation stage, the removal efficiency of COD was slightly unstable. However, after the reactor was stabilized, the COD removal efficiency was higher in the reactor filled with bio-blocks compared to the reactor filled with broken stones. In terms of nitrogen and phosphorus, their removal efficiency was unstable at the initial stage of the reactor operation. This phenomenon was investigated through the bio-block elution experiments. Results indicated that nitrogen and phosphorus were eluted from the bio-blocks affecting their removal at the initial operation. Furthermore, based on elution tests conducted after the dry ashing of the waste sewage sludge, part of the nitrogen and phosphorus was eluted similar to the bio-block elution test results, although considerable amounts of nitrogen and phosphorus were reduced compared to the sludge cake. Prior to the use of the waste sewage sludge bio-blocks as a filter medium to remove non-point source pollutants, a stabilization period of 10 days was required. After the stabilization process, results showed similar characteristics as general aggregates. Moreover, to use the bio-block as a filter medium for the non-point pollutant removal, the filling ratio of 75% was the most suitable as it resulted in the highest nitrogen removal efficiency after the stabilization. The results of this study suggested that waste sewage sludge can be suitably recycled as a mixed raw material for the bio-blocks, with satisfactory application as a filter medium in artificial wetlands, stormwater runoff problems, stream water pollutants to eliminate non-point source pollutants.