• Title/Summary/Keyword: COD 분율화

Search Result 6, Processing Time 0.018 seconds

Evaluation of the COD Fractionation Capability Using Storage Microorganism from EBPR Process (EBPR 공정내 저장 미생물을 이용한 유입수 분율 분석능 평가)

  • Kim, Youn-Kwon;Seo, In-Seok;Kim, Hong-Suck;Kim, Ji-Yeon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.4
    • /
    • pp.25-31
    • /
    • 2004
  • In conventional activated sludge process, COD fractions in wastewater are important parameters, significantly. Depending on characteristics of influent COD fractionation, activated sludge process requires a major change of a process operation to ensure meeting a stricter standards. In order to validate and evaluate the accuracy of the traditional COD fractionation methodologies, readily and slowly biodegradable COD was mixed using glucose and peptone as a sole carbon source in a synthetic wastewater, respectively. In this research, prediction of the COD fraction was made using the OUR(Oxygen Utilization Rate) and the NUR(Nitrate Utilization Rate) experiments. The result showed that COD fractions calculated by OUR experiment were similar to the composition of synthetic wastewater. On the other hand, it was found that an error was generated during the NUR experiment. This error was due to the intracellular storage period for storage microorganisms such as PAOs, and the error in COD fraction was observed about 8-14 % in terms of Total COD.

  • PDF

Evaluation of COD Solubilization and Reduction of Waste Activated Sludge by pH Control (pH 조절을 통한 폐활성 슬러지의 COD 가용화 및 감량화 평가)

  • Kim, Youn Kwon;Moon, Yong Taik;Kim, Ji Yeon;Seo, In Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.551-558
    • /
    • 2007
  • From the view point of biological wastewater treatment, C/N ratio is one of the most important factor in biological nutrient removal process. However, municipal sewage in Korea is characterized by extremely low content of carbon source and relatively higher portion of N source. Accordingly, it is necessary to dose external carbon source in order to obtain higher degree of carbon source within the process. In this study, the effects of pH pretreatment as an alternative plan for increasing carbon source on the cell disruption and COD solubility of waste activated sludge were conducted under well defined experimental conditions. During 5 hours, the value of COD solubilization rate ($S_R$) at pH 11.5 is approximately 4.4 times higher than the value of $S_R$ at pH 9.5. It is expected that the level of SCOD increased due to the result from cell disruption. However, VSS/TSS ratio was not significantly changed after 5 hours. As Alkalinity changes gradually from less than 15, 30 and 60 meq NaOH/L, average RBCOD/SCOD fraction showed 34, 36 and 45%,respectively.

Effect of H2O2 Injection and Temperature Changing on the Organic Carbon Fraction in Chromatogram Dissolved Organic Carbon (CDOC) from Thermal Pretreatment (H2O2 주입과 온도변화가 열적 전처리 후 발생 슬러리의 CDOC 유기탄소분율에 미치는 영향평가)

  • Kim, Hee-Joong;Kim, Tae-Kyoung;Kim, Youn-Kwon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.3
    • /
    • pp.110-116
    • /
    • 2016
  • Biogas yields point of view, the possibility of reusing excess sludge treated by thermal pretreatment for the purpose of improving the efficiency of the anaerobic digestion process has been investigated in recent year. Thermal pretreatment technology was considered as a pretreatment technique to improve excess sludge properties because of the solubilization of particulate organics. As a view point of sludge reduction and recycle, however, many researchers focused on the ability of particulate hydrolysis and COD solubilization under a high temperature, and few reports have addressed on the physical/chemical characteristics changing. This research was performed to evaluate the effects of a various temperature and chemical additives on carbon formation and fractionation in treated slurry from thermal pretreatment. Based on the results, it was revealed that oxidants injection and temperature changing have significantly caused the change of carbon fractions in slurry from thermal pretreament. Especially, it was considered that the efficiencies of particle hydrolysis increased with the increase of the reaction temperature. Low molecular weight(Mw < 350 g/mol) organic carbon formation increased with the increase of oxidants injection. It was expected that results of this research will provide an overview of the characteristics of thermal pretreatement for excess sludge reduction and recycle.

Effects of C/N Ratio on Removal of Organic Matter and Nitrogen in Alternately Intermittently Aerated Nonwoven Fabric Filter Bioreactor (교대로 간헐 포기되는 부직포 여과막 생물반응조에서 C/N비가 유기물 및 질소 제거효율에 미치는 영향)

  • Ahn, Yun-Chan;Bae, Min-Su;Lee, Jong-Ho;Cho, Yun-Kyung;Cho, Kwang-Myeung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.5
    • /
    • pp.499-506
    • /
    • 2005
  • This study was performed to investigate the effects of influent C/N ratio on the removal of organic and nitrogenous compounds by two nonwoven fabric filter bioreactors. The reactors were alternately aerated at an aeration/nonaeration period ratio of 60 min/60 min, and fed with wastewater only during nonaeration period. The influent C/N ratio (COD/TKN) was gradually reduced from 10 to 2. The influent was prepared by diluting the leachate from a foodwaste treatment facility in I city so that the COD concentration could be about 2,500 mg/L. The C/N ratio of the wastewater was adjusted by adding ammonium chloride. The results of the experiment showed that the COD and BOD concentration of the effluent was $40{\sim}54\;mg/L$ and $1{\sim}4\;mg/L$, respectively at the C/N ratios of $10{\sim}3$, and the effluent SS concentration was always below 2.0 mg/L. The T-N removal efficiencies were 96% or higher at C/N ratios of $10{\sim}5$, but decreased to 83% and 81%, respectively at the C/N ratios of 3 and 2.8. At the C/N ratios of 2.6 and 2, the effluent quality deteriorated due to ammonia toxicity. The fraction of nitrifying microorganism in the reactors increased from 10% to 20% as the C/N ratio decreased from 5 to 2.6. Alkalinity consumed were $3.12{\sim}3.49\;g$ alkalinity/g T-N removed at the C/N ratios of $10{\sim}5$, which are lower than the theoretical value of 3.57. However, the ratio increased to 4.63 and 4.87 g alkalinity/g T-N removed, respectively at the C/N ratios of 3 and 2.8.

A Use of Heterotrophic Denitrification for the Supply of Alkalinity during Sulfur-utilizing Autotrophic Denitrification (황-이용 독립영양 탈질시 알칼리도 저감을 위한 종속영양 탈질의 이용방안)

  • Lee, Dong-Uk;Park, Jae-Hong;Bae, Jae-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.1995-2005
    • /
    • 2000
  • The use of heterotrophic denitrification as an alternative method for supplying alkalinity during sulfur-utilizing autotrophic denitrification was evaluated by examining the effects of external carbon source (both type and concentration) and HRT on denitrification efficiency. Concentrations of $NO_3{^-}-N$ and $COD_{Cr}$ of nitrified landfill leachate used for experiment were 700-900mg/L and 900-2500mg/L. respectively, All experiment was conducted with sulfur packed bed reactors (SPBRs) which were operated at $35^{\circ}C$. The fraction of $NO_3{^-}-N$ removed by heterotrophic denitrification ($HDNR_{fraction}$) to balance the alkalinity consumption by autotrophic denitrification varied with the type of external carbon source. When methanol and sodium acetate was added at theoretical HDNRfraction value. 100% denitrification was achieved without alkalinity addition. However, glucose and molasses require $HDNR_{fraction}$ value greater than theoretical value for complete denitrification. The EBCT and volumetric loading rate at which 100% denitrification efficiency could be achieved were 6.76 h and $2.84kg-NO_3{^-}-N/m^3{\cdot}d$, respectively, based on the fact that 100% denitrification occurred within the bottom 11.5 cm layer of the SPBR. The maximum nitrogen removal rate occurred with 89% removal efficiency at loading rate of $5.05kg-NO_3{^-}-N/m^3{\cdot}d$. However, at short EBCT, clogging of SPBR was observed with excess growth of heterotrophic denitrifiers. This problem may be eliminated by back washing or by separating of heterotrophic denitrification from sulfur-utilizing denitrification.

  • PDF

Degradation of Polyvinyl Alcohol in Dye-Processing Wastewater by Agar-Acrylamide Microbial Immobilization Method (한천-아크릴아마이드 미생물 고정화법에 의한 폐수 중 폴리비닐알콜의 분해)

  • 김재훈;김정목조무환
    • KSBB Journal
    • /
    • v.10 no.3
    • /
    • pp.241-248
    • /
    • 1995
  • For the treatment of poorly biodegradable polyvinyl alcohol(PVA) in dye-processing wastewater, immobilized microbial beads were prepared by uslng agar-acrylamide method. PVA removal efficiency for the synthetic wastewater was 85% at the PVA volume loading rate of $3.1g/\ell$.day. In case of real desizing wastewater, PVA removal efficiency was 81.3% at the PVA volume loading rate of $3.25g/\ell$.day. In observation of cross section of immobilized bead passed 5 months with diameter of 2.4mm, the growth of cell was limited by the resistance of substrate and oxygen transfer for the inners region of more than 48% of bead radius from the surface. It was estimated that 70% of total removed PVA was degraded by the immobilized cells in the continuous immobilized reactor. Substrate utilization rate in the suspended reactor was decreased with increasing dilution rates above 0.083 hr-1, but that in the immobilized reactor was increased with increasing dilution rates up to 0.125hr-1. The substrate removal efficiency of immobilized reactor was much superior to that of suspended reactor with increasing dilution rates. Saturation constant of substrate utilization rate equation, Ks was $6.6 g PVA/\ell$, and maximum specific substrate utilization. k was 0.175g PVA/g cell.hr

  • PDF