• Title/Summary/Keyword: CO2 Rate

Search Result 5,776, Processing Time 0.037 seconds

Respiration rate of the Fuji apple according to the ULO storage conditions (ULO 저장에서의 사과 Fuji의 호흡속도)

  • Gang, Jun-Su;Lee, Ho-Jae;Choe, Jong-Uk
    • Food Science and Preservation
    • /
    • v.1 no.2
    • /
    • pp.87-92
    • /
    • 1994
  • For the measurement of the change of respiration rate caused by the gas content of storage atmosphere which furnishes important data for the interpretation of ULO storage, GC was used. It has been shown that the respiration rate and respiratory heat generation rate of Fuji apple is more than doubled in normal low temperature storage when compared with ULO storage, and that in ULO storage the respiration rate and respiratory heat generation rate directly proportional to the concentration of O2 in storage atmosphere as well as inversely proportional to that of CO2. It was possible to establish a functional formula for the respiratory heat generation rate of Fuji apple in all the storage conditions in terms of u=-0.7638+0.0003 O2-0.0007 log(CO2)+0.1369 log(Tb) concerning temperature and the concentration of O2 and CO2

  • PDF

A Kinetic Study on the Hydrogen-induced Amorphization in ErCo2 Laves Compound (ErCo2 Laves 화합물에서의 수소유기 비정질화에 관한 속도론적 연구)

  • Yong, Yoon-Joong;Lee, Jai-Young
    • Journal of Hydrogen and New Energy
    • /
    • v.4 no.1
    • /
    • pp.11-19
    • /
    • 1993
  • The kinetic studies of the hydrogen induced amorphization in $ErCo_2$ Laves phase is observed by the internal standard method using X-ray diffraction intensities. The activation energy and rate constant exponent for the amorphization in $ErCo_2$ are found to be 26 kcal/mole and 0.78, respectively. From these results, it is believed that the mechanism of the hydrogen induced amorphization in $ErCo_2$ is related to the motion of Co atoms. Though there are many similar physical properties between $ErCo_2$ and $ErNi_2$, the activation energy for the amorphizatin in $ErCo_2$ is larger than that in $ErNi_2$ and the amorphization rate in $ErCo_2$ is slower. It is suggested that these differences of activation energy for the hydrogen induced amorphization and the amorphization rate between $ErCo_2$ and $ErNi_2$ is due to the occurence of structural change on forming crystalline hydride.

  • PDF

The Aquation of Co(Ⅲ) Complexes in Pure Water and Mixed Water-Organic Solvents With Hg$^{2+}$ (수용액 및 물-유기용매 혼합용매에서의 Hg$^{2+}$ 에 의한 Co(Ⅲ) 착물의 수화반응)

  • Oh Chang Eon;Yoon Doo Cheon;Doh Myung Ki
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.5
    • /
    • pp.438-444
    • /
    • 1990
  • Observed rate constants (k$_{obs.}$) for Hg$^{2+}$-catalysed aquation of cis-[Co(en)$_2$(OH$_2$)Cl]$^{2+}$, [Co(NH$_3$)$_5$Cl]$^{2+}$, cis-[Co(NH$_3$)$_4$(OH$_2$)Cl]$^{2+}$, and [Co(NH$_2$CH$_3$)$_5$Cl]$^{2+}$ were measured at various concentrations of Hg$^{2+}$. The k$_{obs.}$ was increased with increasing the concentrations of Hg$^{2+}$. The k$_{obs.}$ were related to mechanistically derived rate constants by the relationship; Rate = k$_2$K[complex][Hg$^{2+}$]. Various mixed aqueous-organic solvent have been successfully employed for Hg$^{2+}$-catalysed aquation of octahedral myetal complexes. From the slope of the plot of log k againt Y (solvent ionizing power), the mechanism on the aquation of Co(Ⅲ) complexes by Hg$^{2+}$ has been suggested to be I$_d$-mechanism. The change in a rate on aquation of each Co(Ⅲ) complex was related to the ligand field parameters (${\Delta}$), for Co(Ⅲ) complexes.

  • PDF

Growth and Photosynthetic Responses of One C3 and Two C4 Chenopodiaceae Plants to Three CO2 Concentration Conditions

  • Ishikawa, Shin-Ichi
    • Journal of Ecology and Environment
    • /
    • v.31 no.4
    • /
    • pp.261-267
    • /
    • 2008
  • Growth and photosynthetic responses of one $C_3$ and two $C_4$ plants in the family Chenopodiaceae in three $CO_2$ concentration $([CO_2])$ conditions-low (about $243{\mu}mol\;mol^{-1}$, LC), present (about 378, PC), and high (about 465, HC)-were investigated in open top chambers. The relative growth rate (RGR) and net assimilation rate in the $C_3$ plant, Chenopodium album, increased with increasing $[CO_2]$, though the RGR was not enhanced significantly in the HC condition. The leaf area ratio and leaf weight ratio of the $C_3$ plant drastically decreased with increasing $[CO_2]$, suggesting that the $C_3$ plant invests more biomass to leaves in lower $[CO_2]$ conditions. The two $C_4$ plants, Atriplex glauca and A. lentiformis, showed relatively small changes in those growth parameters. These photosynthetic-pathway-dependent responses suggest that growth patterns of $C_3$ and $C_4$ plants have been altered by past increases in atmospheric $[CO_2]$ but that there will be relatively little further alteration in the future high-$CO_2$ world.

Effects of 37℃ Carbon Dioxide Pneumoperitoneum on Core Body Temperature, Systolic Blood Pressure, Heart Rate and Acid-Base Balance: A Randomized Double-blind Controlled Trial (복강경 수술에서 기복제 이산화탄소의 37℃ 가온이 수술 중 체온, 수축기압 및 심박동수와 산염기 균형에 미치는 영향)

  • Park, Jin il;Yoon, Haesang
    • Journal of Korean Biological Nursing Science
    • /
    • v.19 no.2
    • /
    • pp.76-85
    • /
    • 2017
  • Purpose: The purpose of this study was to compare the effects of $21^{\circ}C\;CO_2$ and $37^{\circ}C\;CO_2$ pneumoperitoneum on body temperature, blood pressure, heart rate, and acid-base balance. Methods: Data were collected at a 1300-bed university hospital in Incheon, from February through September 2012. A total of 74 patients who underwent laparoscopic colectomy under general anesthesia with desflurane were randomly allocated to either a control group or an experimental group. The control group received $21^{\circ}C\;CO_2$ pneumoperitoneum; the experimental group received $37^{\circ}C\;CO_2$ pneumoperitoneum. The pneumoperitoneum of the two groups was under abdominal pressure 15 mmHg. Body temperature, systolic blood pressure, heart rate and acid-base balance were assessed at 30 minutes and 90 minutes after pneumoperitoneum, and again at 30 minutes after arriving at the Post Anesthesia Care Unit. Results: Body temperature in the $37^{\circ}C\;CO_2$ pneumoperitoneum group was significantly higher (F= 9.43, p< .001) compared to the $21^{\circ}C\;CO_2$ group. However, there were no statistically significant differences in systolic blood pressure (p= .895), heart rate (p= .340), pH (p= .231), PaCO2 (p= .490) and HCO3- (p= .768) between the two groups. Conclusion: Pneumoperitoneum of $37^{\circ}C\;CO_2$ is effective for the increase of body temperature compared to pneumoperitonium of $21^{\circ}C\;CO_2$, and it does not result in a decrease of blood pressure, heart rate or acid-base imbalance.

Analysis of Factors Rerated to Absorption Ability of Foliage Plants Exposed to $O_3$ (관엽식물의 오존($O_3$)흡수능에 관여하는 요인 분석)

  • 박소홍;배공영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.6
    • /
    • pp.537-544
    • /
    • 1998
  • We selected Spathiyhyllum patinii and Pachira aqkatica, since the former has high O3 absorption while the latter low absorption, and analyzed physiological factors such as diffusive coefficient, transpiration rate, photosynthetic rate, and CO2 absorption rate, which affected O3 absorption capacity There was significant relationship between gas absorption capacity and the other factors; photosynthetic rate, diffusive resistance, stomatal resistance and CO2 absorption rate. Therefore model formula for estimation of O3 absorption rate in plant was formulated by making use of these factors. There was difference for the estimation of O3 absorption rate according to plant species. In case of Spathiphyllum patinii, photosynthetic rate is an optimal factor for estimation of O3 absorption capacity. On the other hand, stomatal resistance and diffusive resistance are optimal factors of Pachira aquatica among various physiological ones. And we knew that CO2 absorption rate is a potential factor to evaluate gas absorption capacity regardless of plant species. But considering efficiency and practicality, diffusive resistance was the most effective factor for the estimation of O3 gas absorption.

  • PDF

A Study on Isolation of BTEX Degrading Microorganism and Variation of BTEX Removal Efficiency and Microorganism Growth Rate According to Co-Culture (BTEX 분해미생물의 순수분리와 혼합 배양에 따른 기질 분해율 및 미생물 성장률 변화에 관한 연구)

  • Chung, Kyung-mi;Lee, Sang-hyup;Lee, Han-woong;Hong, Seok-won;Kim, Young-o;Choi, Yong-su;Yu, Myong-jin
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.347-352
    • /
    • 2005
  • The isolated microorganisms, Pseudomonas stutzeri, Raoultella planticola (Klebsiella), Serratia fonticola from petroleum contaminated soil were enriched on benzene, toluene, ethylbenzene, o-xylene as carbon and energy sources, respectively. And the degradation characteristics of BTEX was observed in the mixed BTEX substrates. We found that the BTEX in mixed substrates were degraded more than 50% by three isolated microorganisms. Among three isolated microorganisms, the highest degradation rate was observed in Pseudomonas stutzeri, but the degradation rate was different according to microorganisms. In order to increase the degradation efficiency, we applied the co-culture of isolated three microorganisms. The mixture rate of pseudomonas stutzeri : Raoultella planticola (Klebsiella) : Serratia fonticola was follows ; 1:2:1, 1:1:2, and 2:1:1, respectively. In two co-culture of 1:2:1 and 1:1:2, degradation rate was lower than isolated microorganisms. However, degradation rate became higher than isolated microorganisms and the degradation rate of benzene, toluene, and ethylene was more than 95% in co-culture of 2:1:1. The degradation rate increased through the co-culture of isolated microorganisms, however, the growth rate decreased. This was resulted from the substrate competition between microorganisms. The co-culture of microorganisms is a effective method to increase the degradation efficiency of BTEX and the co-culture mixing rate is a important factor for determination of degradation efficiency.

Debinding Process Using Supercritical Fluids in Metal Powder Injection Molding (분말사출성형에서 초임계유체를 이용한 탈지공정)

  • 김용호;임종성;이윤우;박종구
    • Journal of Powder Materials
    • /
    • v.10 no.1
    • /
    • pp.6-14
    • /
    • 2003
  • The purpose of the present study is to investigate the method decreasing debinding time as well as lowering operation condition than pure supercritical $CO_2$ debinding by using cosolvent or binary mixture of propane + $CO_2$. First method is to add cosolvent, such as n-hexane, DCM, methanol, 1-butanol, in supercritical $CO_2$. In case of adding cosolvent, we were found the addition of non-polar cosolvent (n-hexane) improves dramatically the binder removal rate (more than 2 times) compared with pure supercritical $CO_2$ debinding, second method is to use mixture of supercritical propane + $CO_2$, as solvent. In case of using mixture of supercritical propane + $CO_2$, the rate of debinding speeded up with increasing of pressure and concentration of propane at 348.15 K. It was found that addition of cosolvent (e.g., n-hexane, DCM) and binary mixture propane + $CO_2$ for supercritical solvent remarkably improved binder removal rate for the paraffin wax-based binder system, in comparison with using pure supercritical $CO_2$.

The Characteristics of Attrition of Absorbents for Pre-combustion CO2 Capture (연소 전 CO2 포집 흡수제들의 마모특성)

  • Ryu, Hojung;Lee, Dongho;Moon, Jongho;Park, Youngcheol;Jo, Sungho
    • Journal of Hydrogen and New Energy
    • /
    • v.24 no.5
    • /
    • pp.428-436
    • /
    • 2013
  • Attrition characteristics of $CO_2$ absorbents for pre-combustion $CO_2$ capture were investigated to check attrition loss of those absorbents and to determine solid circulation direction and the better $CO_2$ absorbent. The cumulative attrition losses of two absorbents increased with increasing time. However, attrition loss under a humidified condition was lower than that under a non-humidified condition case. Between two absorbents, attrition loss of PKM1-SU absorbent was higher than that of P4-600 absorbent. The average particle sizes of the attrited particles were less than $2.5{\mu}m$ for two absorbents under a non-humidified condition case, and therefore, we could conclude that the main mechanism of attrition for two absorbents is not fragmentation but abrasion. Based on the results from the test for the effect of humidity on the attrition loss, we selected solid circulation direction from SEWGS reactor to regeneration reactor because the SEWGS reactor contains more water vapor than regeneration reactor. Attrition loss and make-up rate of two absorbents were compared based on the results from $CO_2$ sorption capacity tests and attrition tests. Required make-up rate of P4-600 absorbent was lower than that of PKM1-SU absorbent. However, more detail investigation on the optimum regeneration temperature, manufacturing cost, solid circulation rate, regeneration rate, and long-term sorption capacity should be considered to select the best $CO_2$ absorbent.

Design and evalution of pulsed $CO_2$ laser system using high repetition ratio and high precision (고반복율 및 고정밀방식을 이용한 펄스형 $CO_2$ Laser 시스템 설계 및 평가)

  • 김흥수;김휘영
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.8
    • /
    • pp.1055-1062
    • /
    • 2001
  • Study, it is the purpose to develope a cheap and compact pulsed $CO_2$ laser with pulse repetition rate range of 1 KHz. We used a IGBT switched power supply as a power supply, which is cheap and simple comparing to others. PIC one-chip microprocessor was used for precise control of a laser power supply on the control part. And the laser cavity was fabricated as an axial and water cooled type. The laser performance characteristics as various parameters, such as pulse repetition rate, gas pressure, and gas mixture rate have been investigated. The experiment was done under the condition of total pressure of $CO_2$$N_2$:He = 1:3:10, 1:1.5:5, 1:9:15 from 6 Torr to 15 Torr and pulse repetition rate from 100 Hz to 900 Hz. As a result, the maximum average outpu was about 20.5 W at the total pressure of 15 Torr, the gas mixture $CO_2$$N_2$:He = 1:9:15 and the pulse repetition rate of 700 Hz.

  • PDF