• Title/Summary/Keyword: CO2 Rate

Search Result 5,777, Processing Time 0.033 seconds

The Oxidation of Hydrazobenzene by Oxygen Catalysed by Co (3MeOsalen) in Methanol

  • Homer Roger B.;Cannon Roderick D.;Kim Stephen S.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.6 no.2
    • /
    • pp.115-118
    • /
    • 1985
  • The oxidation of hydrazobenzene by oxygen in methanol solution is catalysed by Co(3MeOsalen) which is a synthetic oxygen carrier. The products are trans-azobenzene and water. The rate of the reaction has been studied spectrophotometrically and the rate law established. A mechanism involving a ternary complex of catalyst, hydrazobenzene and oxygen has been proposed.

Shipboard Verification Test of Onboard Carbon Dioxide Capture System (OCCS) Using Sodium Hydroxide(NaOH) Solution (가성소다(NaOH) 용액을 이용한 선상 이산화탄소 포집 장치의 선박 검증시험)

  • Gwang Hyun Lee;Hyung Ju Roh;Min woo Lee;Won Kyeong Son;Jae Yeoul Jeong;Tae-Hong Kim;Byung-Tak NAM;Jae-Ik Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.61 no.1
    • /
    • pp.51-60
    • /
    • 2024
  • Hi Air Korea and Hanwha ocean are currently developing an Onboard Carbon dioxide Capture System (OCCS) to absorb CO2 emitted from ship's engine using a sodium hydroxide(NaOH) solution, and converting the resulting salt into a solid form through a chemical reaction with calcium oxide (CaO). The system process involves the following steps; 1)The reaction of CO2 gas absorption in water, 2)The reaction between carbonic acid (H2CO3) and NaOH solution to produce carbonate or bicarbonate, and 3)The reaction between carbonate or bicarbonate and CaO to form calcium carbonate (CaCO3). And ultimately, the solid material, CaCO3, is separated and discharged using a separator. The OCCS has been installed on an ship and the test results have confirmed significant reduction effects of CO2 in the ship's exhaust gas. A portion of the exhaust gas emitted from the engine was transferred to the OCCS using a blower. The flow rate of the transferred gas ranged from 800 to 1384 m3/hr, and the CO2 concentration in the exhaust gas was 5.1 vol% for VLSFO, 3.7 vol% for LNG and a 12 wt% NaOH solution was used. The results showed a CO2 capture efficiency of approximately 42.5 to 64.1 vol% and the CO2 capture rate approximately 48.4 to 52.2kg/hr. Additionally, to assess the impact of the discharged CaCO3on the marine ecosystem, we conducted "marine ecotoxicity test" and performed Computational Fluid Dynamics (CFD) analysis to evaluate the dispersion and dilution of the discharged effluent.

Performance Evaluation of Ball Media Filter in DABF applied to SWRO pretreatment process (SWRO 전처리 공정에 적용된 DABF 내 Ball Media Filter 성능 평가)

  • Choi, Seokho;Lee, Junghyun;Park, Sungju;Lee, Younggeun;Roh, Hyungkeun;Kim, Yongbeom
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.6
    • /
    • pp.567-573
    • /
    • 2019
  • DABF(Dissolve Air Flotation with Ball Filter) is developed as the DAF with the addition of a fiber ball at the lower part of the DAF. The DABF with a capacity of 4,500 ㎥/h was constructed at Gijang SWRO plant in Busan. Since the ball filter has high filtration rate, the loading rate of DABF was designed from 20 to 42 ㎥/h/㎡. When one DABF basin is in the back washing mode, the loading rate of other two DABF basins is increased to 42 ㎥/h/㎡. Turbidity at the BF outlet in DABF is <2 NTU at turbidity of 5-10 NTU at the BF inlet. If there is no algae bloom and turbidity is low in raw seawater, only BF in DABF is operated and meets <2 NTU at the BF outlet. Even if BF is operated at high hydraulic loading rates, no significant differential pressure increases and reduction in the turbidity removal rate is minimal in a day. Thus, DABF is the pre-treatment technology that provides stable water quality even with BF onlyoperation without DAF operation. Compared with the DAF, DABF requires additional facilities such as valves, piping, and drainage systems for backwashing the BF. But in terms of footprint and operating costs, DABF has more advantages than DAF. With DABF application, the load of the downstream filtration equipment is decreased so that the capacity of the filtration equipment can be reduced. Also, if the downstream filtration equipment is to be maintained the same regardless of DABF, the operating cost of DABF is less than DAF.

Quantitative Measurement of Carbon Dioxide Consumption of a Whole Paprika Plant (Capsicum annumm L.) Using a Large Sealed Chamber (대형 밀폐 챔버를 이용한 파프리카(Capsicum annumm L.) 개체의 이산화탄소 소비량 측정 및 정량화)

  • Shin, Jong-Hwa;Ahn, Tae-In;Son, Jung-Eek
    • Horticultural Science & Technology
    • /
    • v.29 no.3
    • /
    • pp.211-216
    • /
    • 2011
  • This study was carried out to clarify precise $CO_2$ demands of paprika plants (Capsicum annumm L.) by measuring photosynthesis rates of the leaves in high, low positions, and the $CO_2$ consumption of a whole plant in a large sealed chamber. A photosynthesis measuring system (LI-6400) was used to measure the photosynthetic rates of the leaves located in different positions. A large sealed chamber that can control inside environmental factors was developed for measuring $CO_2$ consumption by a whole paprika plant. With increase of radiation, photosynthetic rates of the leaves in higher position became larger than those in lower position. The $CO_2$ consumption by the plant was estimated by using decrement of $CO_2$ concentration from initial level of 1500 ${\mu}mol{\cdot}mol^{-1}$ in the chamber with increase of integrated radiation. A regression model for estimating $CO_2$ consumption by the plant (leaf area = 7,533.4 $cm^2$) was expressed with integrated radiation (x) and was suggested as $y=-0.06234+3.671^*x/(2.589+x)$ ($R^2=0.9966^{***}$). The photosynthetic rate of the whole plant measured in the chamber was 3.4 ${\mu}mol\;CO_2{\cdot}m^{-2}{\cdot}s^{-1}$ under 300 ${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ light intensity, which is in-between photosynthetic rates of the leaves in high and low positions. For this reason, some differences between required and supplied $CO_2$ amounts in greenhouses might occur when depending too much on photosynthetic rates of leaves. Therefore, we can estimate more accurately $CO_2$ amount required in commercial greenhouses by using $CO_2$ consumption model of a whole plant obtained in this study in addition to leaf photosynthetic rate.

EFFECT OF QUINONES ON $NADPH_2$ OXIDATION AND PHOTOSYNTHETIC $CO_2$ ASSIMILATION IN CHLORELLA PYRENOIDOSA (Chlorella Pyrenoidosa에 있어서 $NADPH_2$의 산화(酸化)와 광합성(光合性)에 의(依)한 $CO_2$ 동화작용(同化作用)에 대(對)한 Quinone의 영향(影響))

  • Cho, Duck-Hiyon
    • Applied Biological Chemistry
    • /
    • v.11
    • /
    • pp.29-33
    • /
    • 1969
  • 1. The oxidizability of $NADPH_2$ by quinones in the presence of $NADPH_2$-diaphorase was tested under aerobic conditions. Also the $^{14}CO_2$-fixation rates were compared when Chlorella suspensions were pretreated with $3{\cdot}10^{-5}M$ cocentration of variou quinones for 10 minutes prior and during the $^{14}CO_2$-fixation period. 2. A close correlation seems to exist between the rate of $NADPH_2$ oxidation by quinones and the $^{14}CO_2$-fixation rate. The effect of quinones on $NADPH_2$ oxidation and $^{14}CO_2$-fixation were in the order of Dichlone>06-K>NQ>BQ. 3. It is postulated that the phytotoxicity of quinones on Chlorella is due to the deprival of $NADPH_2$ consequently inhibiting $^{14}CO_2$-fixation, thus causing death of the cells. 4. The effect of quinones on amino acids biosyn-thesis in Chlorella was one of depressed rates, which was especially noted in the case of dichlone. This would be expected from a consideration of $NADPH_2$ deprival and inhibition of $^{14}CO_2$-fixation. Sucrose synthesis was either not affected or rather stimulated, the reasons of which are not clear at the present time.

  • PDF

Studies on Effect of $CO_2$ Concentration in Air and Pb Concentration in Soil on Pillbug Growth and Bio-accumulation (대기 중 $CO_2$ 및 토양 중 Pb 농도 증가가 공벌레의 성장과 공벌레 체내 Pb 축적에 미치는 영향에 관한 연구)

  • Whang, Hwa-Yeon;Lee, Sang-Don
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.6
    • /
    • pp.539-546
    • /
    • 2010
  • In nature, the overall effect of heavy metals on the biota can be influenced by a number of environmental factors like soil characteristics and air pollution by elevated $CO_2$. Pillbugs(Isopoda, Armadillium vulgare) take up heavy metals with their food and store them mainly in the vesicles of hepatopancreas. They accumulate certain metals, occuring in relatively large numbers, are easily collected and identified. Therefore, it has been suggested that total body concentration of metals in pillbugs could be positively correlated to the levels of environmental exposure and that pillbugs could be used as biological indicators of metal pollution and global change by $CO_2$. The aim of the study is to determine effects of heavy metal concentrations in soil and elevated $CO_2$ on pillbugs'body accumulation of heavy metal and growth rate. In this study, pillbugs were collected at five sites (N=287) May 2006. Cu and Zn concentrations in pillbugs were higher than in soils (1.39-41.70 times) than in control. The high bioconcentration of lead in Sangam may be partly associated with reclaimed land uses. Pillbugs in low $CO_2$ and Pb condition showed higher growth rate than in elevated $CO_2$ and Pb condition.

Study on CO2 Decomposition using Ar/CO2 Inductively Coupled Plasma (아르곤/이산화탄소 혼합가스의 유도 결합 플라즈마를 이용한 이산화탄소 분해 연구)

  • Kim, Kyung-Hyun;Kim, Kwan-Yong;Lee, Hyo-Chang;Chung, Chin-Wook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.135-140
    • /
    • 2015
  • Decomposition of carbon dioxide is studied using $Ar/CO_2$ mixture inductively coupled plasmas (ICP). Argon gas was added to generate plasma which has high electron density. To measure decomposition rate of $CO_2$, optical emission actinometry is used. Changing input power, pressure and mixture ratio, the plasma parameters and the spectrum intensity were measured using single Langmuir probe and spectroscope. The source characteristic of Carbon dioxide ICP observed from the obtained plasma parameters. The decomposition rate is evolved depending on the reaction and discharge mode. This result is analyzed with both the measurement of the plasma parameters and the dissociation mechanism of $CO_2$.

Highly stabilized microstructure and excellent electrochemical performances of Ni-rich LiNi0.9Co0.05Mn0.05O2 cathode via La modification (La 개질을 통한 Ni-rich LiNi0.9Co0.05Mn0.05O2 양극재의 고도로 안정화된 미세구조 및 우수한 전기화학적 성능)

  • Seung-Hwan, Lee
    • Journal of Industrial Technology
    • /
    • v.42 no.1
    • /
    • pp.1-5
    • /
    • 2022
  • Although the mileage of electric vehicles can be increased based on the excellent energy density of the LiNi0.9Co0.05Mn0.05O2, it is known that the reason for limiting its use is the low lifespan and poor surface stability due to the structural deformation of the LiNi0.9Co0.05Mn0.05O2. To improve the structural stability of LiNi0.9Co0.05Mn0.05O2, electrochemical performance is improved by La coating on the surface. La-modified LiNi0.9Co0.05Mn0.05O2 shows an initial capacity of 210.6 mAh/g, a capacity retention rate of 89.9 % after 50 cycles, and a retention rate of 52.5% at 6.0 C. These are superior performances than the pristine sample, because the structural stability of the LiNi0.9Co0.05Mn0.05O2 cathode is improved by the La coating.

Reactivity of Coal Char Gasification with $CO_2$ at Elevated Pressure (가압하 석탄 촤의 $CO_2$ 가스화 반응성 연구)

  • 박호영;안달홍;김시문;김종진
    • Journal of Energy Engineering
    • /
    • v.12 no.3
    • /
    • pp.231-240
    • /
    • 2003
  • Reactivity of Char-CO$_2$ gasification of five coals for power generation was investigated with PTGA in the temperature range 850∼1000$^{\circ}C$ and the pressure range 0.5∼2.0 MPa. The effect of coal rank, initial char characteristics and pressure on the reaction rate was evaluated for five chars. The reactivity of low lank coal char was better than that of high rank coal char, and this could be explained with the initial pore structure and surface area of char. Meso/macro-pores of char seems to markedly affect char reactivity by way of providing channels for diffusion of reactant gas into the reactive surface area. For the range of tested pressure, the reaction rate is proportional to CO$_2$ partial pressure and the reaction order ranges from 0.4 to 0.7 for five chars. The effect of total pressure on the reaction rate was small, and kinetic parameters, based on the unreacted core model, were obtained for five chars.

Operational Characteristics of a Dry Electrostatic Precipitator for Removal of Particles from Oxy Fuel Combustion (순산소 연소 배출 입자 제거용 건식 전기집진장치 운전 특성)

  • Kim, Hak-Joon;Han, Bang-Woo;Oh, Won-Seok;Hwang, Gyu-Dong;Kim, Yong-Jin;Hong, Jeong-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.27-34
    • /
    • 2010
  • In a test duct with closed configuration, particle removal performance of an edge-plate type electrostatic precipitator (ESP) was evaluated at a high flow rate in $CO_2$ rich environments by changing gap distances between collection plates, concentrations of $CO_2$, particle sizes, types of electrodes, and types of power supplies. At the same experimental conditions, collection efficiency of particles with the mean particle size, 300 nm, decreased as the gap distance and $CO_2$ concentration increased because of low electrostatic force and low discharged current. In addition, as the particle size increased, the efficiency increased because of high charging rate of the large particles. With the electrode type which has higher surface area of a discharging plate and with the power supply which applied 25 kHz-pulsed DC voltages, the removal efficiency was high even in rich $CO_2$ condition due to high electrostatic force at the same power consumption.