• 제목/요약/키워드: CO removal

검색결과 1,582건 처리시간 0.031초

분산형 빗물관리시설 적용을 위한 수질정화기능 여재 성능 평가 (Performance Evaluation of Soil Media for Water Quality Purification at LID Application)

  • 박찬기;김춘수;김황희;유성열;전지홍
    • 한국농공학회논문집
    • /
    • 제56권6호
    • /
    • pp.85-91
    • /
    • 2014
  • In this study, the water quality purification of new medias which were NPS media, hyugato, mineral stone, charcoal for applying soil media of Integrated Management Practices (IMPs) of Low Impact Development (LID) were evaluated. The influent concentrations of COD, T-N, and T-P were 117.8 mg/L, 17.1 mg/L, and 2.062 mg/L, respectively. The infiltration capacities of NPS media, hyugoto, mineral stone, charcoal, and gravel were $7.1{\times}10m/s$, $7.3{\times}10^{-5}m/s$, $7.9{\times}10^{-5}m/s$, $6.0{\times}10^{-5}m/s$, respectively. All media meet criteria of infiltration capacity as surface soil layer at IMPs which is over $1.0{\times}10^{-5}m/s$. Maximum removal rates of COD, T-N, and T-P occurred at Charcoal with 98 % of COD removal rate, NPS with 78 % of T-N removal rate, and hyugato with 75 % fo T-P removal rate, respectively. For more high removal efficiency of all water quality item, the mixed media which is 4.5(NPS media): 1(charcoal) : 4.5 (hyugato) as volume ratio was evaluated. The infiltration capacity of mixed media was $7.9{\times}10^{-5}m/s$ and met the criteria of infiltration as surface soil layer. The water quality removal efficiencies of mixed media were very high with showing 70 % for COD, 85 % for T-N, and 71 % for T-P. The mixed media could purify the water quality of surface runoff and was recommended to used at the LID site of ground water quality problem.

감의 이용(利用)에 관(關)한 연구(硏究) -제1보(第一報) 탄산(炭酸)가스처리(處理)가 탈삽(脫澁)에 미치는 영향(影響)- (Studies on the Utilization of Persimmons -(Part 1) Effect of Carton Dioxide Treatment on the Removal of Astringency-)

  • 서온수;손태화
    • Applied Biological Chemistry
    • /
    • 제19권2호
    • /
    • pp.93-98
    • /
    • 1976
  • 경북지방(慶北地方)에서 생산(生産)되는 청도반시와 사곡시의 탈삽조건(脫澁條件)을 구명(究明)하고 탈삽중(脫澁中) 전당(全糖), 환원당(還元糖) 및 경도변화(硬度變化)를 조사(詞査)한 과과(果果)과는 다음과 같다. 1) 탈삽경과중(脫澁經過中) tannin변화(變化)는 탄산(炭酸)가스농도(濃度)가 높을수록 감소(減少)가 급격(急激)히 일어났으며 낮을수록 완만하였다. 2) 산소농도(酸素濃度)가 탈삽(脫澁)에 미치는 영향(影響)에 있어서, 청도반시는 탄산(炭酸)가스농도(濃度)가 높을 때는 큰 영향(影響)이 없었으며 저농도(低濃度)일 때는 영향이 있었는데 특(特)히 사곡시에서는 현저(顯著)한 영향이 있었다. 3) 청도반시 및 사곡시의 탈삽(脫澁)에 있어서 적정(適正)가스농도(濃度)는 탄산(炭酸)가스 $60{\sim}70%$, 산소(酸素) $6{\sim}8%$이었으며 탈삽(脫澁) 소요일수(所要日數)가 청도반시 3일 사곡시는 4일이 소요(所要)되었다. 4) 탈삽경과중(脫澁經過中) 전당(全糖)의 변화(變化)는 두 품종(品種) 모두 탄산(炭酸)가스 농도(濃度)에 관계(關係)없이 완만(緩慢)히 감소(減少)하였으며, 산소농도별(酸素濃度別)로는 산소농도(酸素濃度)가 낮을수록 감소(減少)가 심하였다. 5) 탈삽경과중(脫澁經過中) 환원당(還元糖)의 변화(變化)는 품종(品種)에 관계(關係)없이 증가(增加)하였으며 탄산(炭酸)가스농도(濃度)가 높을수록 증가(增加)되었다.

  • PDF

연속흐름형 Jet loop reactor에서 CO2를 이용한 알칼리폐수의 중화 (Neutralization of Alkaline Wastewater with CO2 in a Continuous Flow Jet Loop Reactor)

  • 강대엽;김미란;임준혁;이태윤;이제근
    • Korean Chemical Engineering Research
    • /
    • 제54권1호
    • /
    • pp.101-107
    • /
    • 2016
  • 본 연구에서는 $CO_2$를 이용한 알칼리폐수의 중화처리 시 jet loop reactor의 적용가능성을 검토하고자 하였다. 이를 위해 연속식 jet loop reactor에서 pH=10.1인 알칼리 폐수의 유입유량($Q_{L,in}=0.9{\sim}6.6L/min$)과 유입가스유량($Q_{G,in}=1{\sim}6L/min$)을 변화시키면서 유출수의 pH 변화 및 $CO_2$ 제거특성을 살펴보았다. 중화반응 후 유출수의 pH는 $Q_{L,in}/Q_{G,in}$ 비가 1.1일 때는 $Q_{G,in}$$Q_{L,in}$이 증가하여도 pH가 7.2 정도로 일정하게 유지되었다. 그러나 $Q_{L,in}/Q_{G,in}$ 비가 1.1 이상에서는 $Q_{L,in}/Q_{G,in}$ 비가 증가할수록 $CO_2$ 제거효율 및 배출수의 pH가 증가하는 경향을 보였다. 본 연구범위에서 얻어진 최대 $CO_2$ 제거효율은 98.06%로 $Q_{G,in}=2L/min$, $Q_{L,in}=4L/min$인 조건이었으며, 이때의 유출수 pH는 8.43 이었다.

AMP + AEPD와 AMP + TIPA 수용액을 이용한 이산화탄소의 흡수 및 재생 (Absorption and Regeneration of Carbon Dioxide in Aqueous AMP + AEPD and AMP + TIPA Solutions)

  • 김미숙;최원준;서종범;조기철;김수곤;오광중
    • 한국대기환경학회지
    • /
    • 제23권5호
    • /
    • pp.539-546
    • /
    • 2007
  • Increasing emission of $CO_2$ significantly effects the global warming. Chemical absorption is one of separation methods of $CO_2$ from the industrial flue gases. In this study, the $CO_2$ removal efficiency as well as the $CO_2$ absorption amount of aqueous AMP (2-amino-2-methyl-1-propanol) solutions were measured using the continuous absorption and regeneration apparatus. We investigated the effect of aqueous AMP+AEPD(2-amino-2-ethyl-1, 3-propanediol) and AMP+TIPA (triisopropanolamine) solutions to enhance absorption characteristics of AMP. As a result of this study, the absorption amount and $CO_2$ removal efficiency were increased with adding TIPA into 30 wt.% AMP. The absorption amount and $CO_2$ removal efficiency of aqueous 30 wt.% AMP+5 wt.% TIPA solution were $1.70\;kg-CO_2/kg-absorbent$ and 91.1%, while those of aqueous 30 wt.% AMP solution were $1.58\;kg-CO_2/kg-absorbent$ and 89.3%. In addition, aqueous 30 wt.% AMP+5 wt.% TIPA solution used in the study revealed the high stripping efficiency, which was almost 98%, at the temperature of $110^{\circ}C$. Thus, the temperature of regenerator should be operated at $110^{\circ}C$.

스크러버를 이용한 주류공정 내 고농도 이산화탄소 제거효율 평가 (Evaluation of CO2 Removal Efficiency in Liquor plant by scrubber)

  • 박일건;박영식
    • 한국응용과학기술학회지
    • /
    • 제34권4호
    • /
    • pp.986-994
    • /
    • 2017
  • 본 논문에서는 주류공정의 고농도 $CO_2$ 제거를 위한 스크러버의 $CO_2$ 흡수 성능평가를 진행하였다. Lab-scale 실험을 통해서 설계인자인 액가스비($18L/m^3$), 공탑속도(0.14 m/s)를 산정하였다. 설계인자를 기반으로 제작한 $5m^3/min$$CO_2$ 흡수 반응기로 실험한 결과, 풍량이 1, 2, 3, 4, $5m^3/min$ 증가시 $CO_2$ 제거율은 98.47%, 96.46%, 92.95%, 89.71%, 85.49%로 감소하는 경향을 보였다. 또한 스크러버를 사용하기 전 후의 에너지 개선율(5.4%) 평가 및 에너지 절감량(11.5 TOE/year), 온실 가스 감축량(6.5 TC/year)를 산정하였다.

Analysis of black 'mura' in prism light guide plate for high brightness LCD's

  • Oh, Young-Sik;Yoon, Dae-Gun;Bae, Kyung-Woon;Kim, Youn-Ho;Lim, Young-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.1062-1065
    • /
    • 2004
  • We have analyzed the cause of black "mura" and measured it in prism light guide plate(LGP). Properties of components used in a backlight uint(BLU) have changed by simulation tool. We get major factor of black "mura" for improvement in prism LGP. For the improvement of black "mura", removal of brightness "mura" at input light part must precede preferentially because of reflection characteristic of the prism LGP. Removal of brightness "mura" is improved by hanging of input light part in LGP and dispersion treatment.

  • PDF

고휘도용 프리즘 도광판의 암선연구 (Analysis of back "mura" in prism light guide plate for high brightness LCD's)

  • 오영식;윤대근;배경운;김연호;임영진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.165-168
    • /
    • 2004
  • We have analyzed the cause of black "mura" and measured it in prism light-guide plate (LGP). Properties of components used in a back light. unit (BLU) have changed by Simulation Tool. We get major factor of black "mura" for improvement in prism LGP. For the improvement of black "mura", removal of brightness "mura" at input light part must precede preferentially because of reflection characteristics of the prism LGP. Removal of brightness "mura" is improved by changing of input light part in LGP and dispersion treatment.

  • PDF

화학처리와 한외여과막의 결합공정에 의한 Cs 및 Co의 제거특성 (II) (The Removal Characteristics of Cs$^{+}$ and Co$^{++}$ from Aqueous Wastes by Ultrafiltration in Combination with Chemical Treatment Techniques(II))

  • 이근우;정경환;김길청;김준형
    • 에너지공학
    • /
    • 제5권1호
    • /
    • pp.56-64
    • /
    • 1996
  • 본 연구는 방사성 폐액의 처리를 목적으로 화학처리와 한외여과막의 결합공정에 의해서 Cs과 Co이온의 제거 특성을 조사하였다. 실험은 회분식 UF Stirred Cell을 이용하였고, 화학결합제로서 Cs에 대해서는 시안화철구리화합물, 그리고 Co에 대해서는 Polyacrylic Acid(PAA)를 주입하여 Cs이온과 Co이온의 제거 거동을 조사하였다. Cs의 결합특성은 Langmuir Isotherm형태의 식으로 나타내어 평가하였으며, Cs/K$_2$Cu$_3$(Fe(CN)$_{6}$)$_2$의 몰비가 1.5에서 효율적인 조건임을 알 수 있었다. Co의 제거효율은 용액의 pH, PAA및 Co이온의 몰비에 의해서 결정되었다. Co의 제거거동은 리간드와 Co와의 결합,용액의 pH및 Co농도와의 상호작용에 의한 평형관계식에 의해서 평가하였으며, 이때 90%의 제거율을 얻기 위한 조건은 몰비가 2($\beta$=2)이고 pH가 5.6이었다. 이의 결과로부터 Cs과 Co의 동시제거을 위한 화학첨가제의 주입방법에 대한 제거성능을 평가하였다.

  • PDF

DME 생산공정에서 복합막을 이용한 이산화탄소 제거공정 전산모사 (A Study on Carbon Dioxide Removal Process Using Composite Membrane in DME Production Process)

  • 노상균
    • 한국산학기술학회논문지
    • /
    • 제15권7호
    • /
    • pp.4698-4706
    • /
    • 2014
  • 본 연구에서는 디메틸에테르(dimethyl ether) 생산 공정에 포함된 이산화탄소 제거공정에서 이산화탄소 제거 방법으로 복합막(composite membrane)을 사용하는 공정에 대해 공정구성과 모사를 수행하였다. 복합막은 (주)에어레인에서 제조한 PEI-PDMS(polyetherimide-polydimethyl siloxane) 복합막을 대상으로 하였으며 복합막 공정을 모델링하기 위해서 상용성 화학공정 모사기인 Invensys 사의 PRO/II with PROVISION 9.2를 사용하였다. 그리고 복합막 공정을 모사하기 위해 필요한 각 순수성분들의 투과도 상수는 (주)에어레인에서 수행한 실험 데이터를 회귀분석 하여 새롭게 결정 하였다. 결국 실험을 통해 얻은 투과도 상수와 상용성 화학공정 모사기를 활용하여 이산화탄소를 제거하기 위한 복합막 공정을 구성하고 제거에 필요한 분리막 면적과 Utility 비용을 도출하였다.