• Title/Summary/Keyword: CO laser

Search Result 1,343, Processing Time 0.026 seconds

Principles of Laser Laryngeal Microsurgery (레이저 후두미세수술의 원칙)

  • Moon, Jeong Hwan;Lee, Sang Joon;Chung, Phil-Sang
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.24 no.1
    • /
    • pp.13-17
    • /
    • 2013
  • Laser laryngeal microsurgery is currently the primary method of treatment of various laryngeal diseases. The development of laryngeal microsurgery came from the introduction of a small spot $CO_2$ laser micromanipulator and more precise microlaryngeal instruments. $CO_2$ laser laryngeal microsurgery has enabled very precise surgery because it has small focus size and hemostatic effect. There are some limitations to the use of the $CO_2$ Laser such as adjacent tissue damage and vocal fold scarring. These problems can be minimized through understanding the mechanisms by which lasers function and correctly manipulating the parameters under a surgeon's control. We should also recognize the safety of $CO_2$ laser for the surgeon to precisely perform the procedure.

  • PDF

Fabrication of Barrier Ribs for PDP by $CO_2$ Laser Scribing Method ($CO_2$ Laser Scribing법을 이용한 PDP용 격벽 제조)

  • 안정식;이석영;김원용;전형조;이용호;김용석
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.1
    • /
    • pp.57-62
    • /
    • 2000
  • In this study, an attempt was made to demonstrate the possibility of using laser scribing method in manufacturing the barrier ribs of plasma display panel. The scribing with a CO2 laser was conducted on the green tape produced by the doctor blade tape casting method. Among the processing parameters, the quenching gas pressure, shape of mask, and laser power were found to affect the depth and angle of the scibed barrier ribs.

  • PDF

The History of CO2 Laser Acupuncture and Moxibustion (CO2 레이저 침구 치료의 역사)

  • Jang, Insoo;Yang, Changsop;Sun, Seungho;Jeong, Minjeong;Han, Changho;Hwang, Eui-Hyoung;Seo, Hyungsik
    • Korean Journal of Acupuncture
    • /
    • v.36 no.1
    • /
    • pp.36-43
    • /
    • 2019
  • Objectives : Carbon dioxide ($CO_2$) laser, a high power laser has been used for pain management, dermatology, and surgery and laser acupuncture and moxibustion as well, since it had been oscillated in 1964 at Bell Telephone Laboratories in the US. The purpose of this study is to investigate the history of $CO_2$ laser acupuncture through reviewing studies published in early stage of laser medicine. Methods : To investigate the early history of $CO_2$ laser acupuncture, studies were searched in the electronic databases, including PubMed, ScienceDirect, CNKI, Wanfang, J-STAGE, CiNii, KTNP, and OASIS, since 1964. Articles in English, Chinese, Japanese and Korean were included, and there were no limitations in literature types such as reviews, essays, clinical trials, animal experiments and veterinary research. Results : We found that the first $CO_2$ laser application to acupoints was done by a research team in Shanghai in 1976. They used $CO_2$ laser for acupuncture treatment and it was also the first laser acupuncture treatment in China. Since the first case report of $CO_2$ laser for leukopenia, it has been applied to various diseases in China, Korea, Japan and other western countries. It has been widely applied in the fields of dentistry and veterinary medicine, as well as clinical applications. Conclusions : Not only $CO_2$ laser can be used as laser acupuncture by stimulating the acupoints and meridians, but also can produce moxibustion effect by using heat stimulus. Therefore, it is expected that it will be used in various clinical fields in the future.

An Experimental Study on the Effect of Laser to Bond Strength between Composite Resin and Bovine Teeth (우치치질에 레이저조사시 레진과의 결합강도에 관한 연구)

  • Cho, Ju-On;Song, Kwang-Yeob;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.155-172
    • /
    • 1989
  • The purpose of this study is to measure the bonding strength at the enamel and dentin of extracted bovine incisors when they are irradiated by W Nd: YAG, EoQ Nd: YAG, and CW $CO_2$ laser, etched and then attached by composite resin. The laser-irradiated surface, the etched surface after the laser-irradiation and the interface of the treated surface and resin are observed by using scanning electron microscope. The NP Nd:YAG laser is used at the peam power of 207 KW. The EOQ Nd: YAG laser is used at the peak power of 1.15Mk. The CW $CO_2$ laser is used at the energy output of 5W and 10W in enamel; in dentin, at the energy output of 2W. The obtained results were as follows: 1. The shear bond strength of enamel decreased in the following order: EOQ Nd:YAG laser group, NP Nd:YAG laser group, CW $CO_2$ laser groups, unlased group. The unlased group showed a significant difference from EOQ Nd:YAG laser group (P<0.01), NP Nd:YAG laser group (P<0.05), but no significant difference from CW $CO_2$ laser group (P>0.05). 2. The shear bond strength of dentin decreased in the following order: CW $CO_2$ laser group, NP Nd:YAG laser group, unlased group, EOQ Nd:YAG laser group. The unlased group showed a significant difference from CW $CO_2$ laser group (P<0.01), but no significant difference from Nd:YAG laser groups (P>0.05). 3. The scanning electron microscope of enamel revealed irregular microcrack and pore at the surface in the NP Nd:YAG laser group and CW $CO_2$ laser group, but the crackless flat surface in the EOQ Nd:YAG laser group. 4. The scanning electron microscope of dentin revealed obstruction of in most of dentinal tubule and decrease of diameter. 5. The scanning electron microscope of the interface of resin and enamel revealed prominent penetration of resin tag in the EOQ Nd:YAG laser group.

  • PDF

THE USE OF DENTAL LASER IN ORAL AND MAXILLOFACIAL FIELD (구강악안면외과 영역에서 레이저의 이용)

  • Kim, Young-Kyun;Kim, Hyoun-Tae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.3
    • /
    • pp.298-302
    • /
    • 1999
  • Currently dental laser is used at a variety of dental treatment and many favorable clinical case reports are presented. We performed this study for the presentation of the validity of dental laser which are available and supportable in the oral and maxillofacial surgery. From October, 1998 to March, 1999, dental laser was used in 70 cases. Male patients were 38, female 32. The age ranged from 5 to 77, with a mean of 45.4. Indicated cases were 18 chronic periodontitis, 11 infections, 6 atypical pain, malignant or benign tumor, precancerous lesion, abnormal frenum, TMJ disorder, mucocele, and so forth. $CO_2$ laser(Sharplan 15F, Sharplan Co.) was used in 40 cases, Ho-YAG laser(Duopulse 2000, Excel Co.) 11, Nd-YAG(Duopulse 2000, Excel Co.) 18. We present and discuss about the objectiveness, availability, and future application of laser with case reports.

  • PDF

Study on microstructure of sensitized Alloy 600 rapidly solidified by a $CO_2$ laser beam ($CO_2$ 레이저빔을 이용한 예민화된 Alloy 600의 급속응고 미세구조 연구)

  • 임연수;서정훈;국일현;김정수
    • Laser Solutions
    • /
    • v.1 no.1
    • /
    • pp.18-23
    • /
    • 1998
  • A Study on microstructural changes of sensitized Alloy 600 which was rapidly solidified by a $CO_2$ laser beam was conducted using microscopic equipments such as SEM and TEM. Dissolution of Cr-rich carbides and resultant Cr recovery on the grain boundaries occurred in the heat affected zone (HZA). The microstructure of the laser melted zone (LMZ) having epitaxially solidified from the HAZ was mainly celluar-dendritic with the 〈100〉 crystallographic direction of growth. The Cr concentration was observed to increase along the cell bondaries, and tiny particles were distributed along the cell walls with tangled dislocations around them. Cr-rich carbides had been completely melted by the high density of a laser beam, and were not re-precipitated during the matrix solidification due to a fast cooling rate in the LMZ.

  • PDF

Study on the Mechanical Properties of Laser Welded AZ31 Magnesium Alloy (AZ31 마그네슘 합금 레이저 용접부의 기계적 성질에 관한 연구)

  • Lee, M.Y.;Jeong, B.H.;Jeong, S.M.;Park, H.J.
    • Laser Solutions
    • /
    • v.9 no.1
    • /
    • pp.25-29
    • /
    • 2006
  • This study aimed to investigate the change of mechanical properties with the rolling direction and shielding condition during laser welding of AZ31 magnesium alloy. AZ31 magnesium alloy sheets of 1mm thickness were welded using a continuous wave Nd:YAG laser with and without Ar shielding gas. The effect of Ar shielding gas and rolling direction on the mechanical properties were investigated using Vickers hardness, transverse-weld tensile. Porosity in the weld metals was investigated using an optical microscope. The experimental results showed that mechanical properties of AZ31 magnesium alloy laser welds were upgraded compared to those of base metal. Mechanical properties of AZ31 magnesium alloy laser welds were not substantially changed when Ar shielding gas was supplied.

  • PDF

The local polishing of material surface using the $CO_2$ laser ($CO_2$ 레이저를 이용한 시료 표면의 국부 폴리싱)

  • Kim, Young-Seop;Shon, Ik-Bu;Noh, Young-Chul
    • Laser Solutions
    • /
    • v.12 no.2
    • /
    • pp.7-10
    • /
    • 2009
  • In this paper, we study experimentally the local polishing of $SiO_2$ surface using the $CO_2$ laser. For laser local polishing, we polished to remove the grooves or to be reformed the surface of grooves after forming the grooves on the material surface. We measured the reflectance, transmittance, and beam profile in order to measure the roughness of polished surface. The Atom Force Microscope (AFM) is used to measure roughness of local polishing surface. We can predict that the laser polishing contribute to the removal of generated debris and surface roughness on the micro processing.

  • PDF

Weld Quality Monitoring and Seam Tracking in Making of Welded Tube using $CO_2$ Laser ($CO_2$ 레이저를 이용한 용접튜브 제조공정에서의 용접선 추적 및 용접품질 모니터링)

  • Suh, Jeong;Lee, Jae-Hoon;Kim, Jeng-O;Kang, Hee-Shin;Lee, Moon-Yong;Jung, Byung-Hun
    • Journal of Welding and Joining
    • /
    • v.21 no.7
    • /
    • pp.34-41
    • /
    • 2003
  • Weld quality monitoring and seam tracking along the butt-joint lengthwise to the tube axis are studied. The material of tube is 60kg/$\textrm{mm}^2$ grade steel sheet, and the longitudinal butt-joint is shaped by 2 roll bending machine. The tube with a thickness of 1.5mm, diameter of 105.4mm and length of 2000mm is successfully obtained by the $CO_2$ laser welding system equipped with a seam tracker and plasma sensor. Experimental results show that the developed welding system can be used for the precision seam tracking and the real-time monitoring of weld quality, and the laser welded tube can be used for car body md component after tubular hydroforming.

Minimization of Welding Defect in $CO_2$ Laser Welded Tube

  • Suh Jeong;Kang Hee-Shin;Lee Jae-Hoon;Park Kyoung-Taik;Lee Moon-Yong;Jung Byung-Hun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.3
    • /
    • pp.19-23
    • /
    • 2005
  • To minimize the weld defect in manufacturing of the welded tube by using $CO_2$ laser, the monitoring of the welding quality and the seam tracking along the butt-joint lengthwise to the tube axis are studied. The longitudinal butt-joint is shaped from $60kgf/mm^2$ grade steel sheet by 2 roll bending method, and welded by the $CO_2$ laser welding system equipped with the seam tracker and plasma sensor. The laser welded tube has the thickness of 1.5mm, diameter of 105.4mm and length of 2000mm. The precise positioning of the laser beam on the butt-joint to be assembled is obtained within $200{\mu}m$ by the laser vision sensor. The artificial defects in the butt-joint are well observed by the signal of plasma intensity measured from the plasma sensor of UV wavelength range within 400nm. The developed $CO_2$ laser tube welding system has the function of the precision seam tracking and the real-time monitoring of the welding quality. In conclusion, the laser welded tube can be used for manufacturing of automobile chassis and components after hydro-forming.