• Title/Summary/Keyword: CNR1

Search Result 312, Processing Time 0.027 seconds

Association Analysis between (AAT)n Repeats in the Cannabinoid Receptor 1 Gene and Schizophrenia in a Korean Population (한국인에서 조현병과 Cannabinoid Receptor 1 유전자의 삼핵산 반복서열의 연합에 대한 연구)

  • Kim, Ji-Won;Roh, Yang-Ho;Kim, Min-Jea;Kim, Chea-Ri;Park, Byung-Lae;Bae, Joon Seol;Shin, Hyoung Doo;Choi, Ihn-Geun;Han, Sang-Woo;Hwang, Jaeuk;Woo, Sung-Il
    • Korean Journal of Biological Psychiatry
    • /
    • v.21 no.3
    • /
    • pp.99-106
    • /
    • 2014
  • Objectives Previous studies suggest that the cannabinoid receptor 1 (CNR1) gene could be an important candidate gene for schizophrenia. According to linkage studies, this gene is located on chromosome 6q14-q15, which is known to harbor the schizophrenia susceptibility locus (locus 5, SCZ5, OMIM 803175). The pharmacological agent delta-9-tetrahydrocannabinol (${\Delta}$-9-THC) seems to elicit the symptoms of schizophrenia. The association between CNR1 polymorphisms and schizophrenia is actively being investigated, and some studies have linked the AAT-trinucleotide repeats in CNR1 to the onset of schizophrenia. In this study, we have investigated the association between the AAT-trinucleotide repeats in CNR1 and schizophrenia by studying schizophrenia patients and healthy individuals from Korea. Methods DNA was extracted from the blood samples of 394 control subjects and 337 patients diagnosed with schizophrenia (as per the Diagnostic and Statistical Manual of Mental Disorders, fourth edition criteria). After polymerase chain reaction amplification, a logistic regression analysis, with age and gender as the covariates, was performed to study the variations in the AAT-repeat polymorphisms between the two groups. Results In total, 8 types of trinucleotide repeats were identified, each containing 7, 8, 10, 11, 12, 13, 14, and 15 repeats, respectively. $(AAT)_{13}$ allele was most frequently observed, with a frequency of 33.6% and 31.6% in the patient and control groups, respectively. The frequency of the other repeat alleles in the patient group (in the decreasing order) was as follows : $(AAT)_{13}$ 33.6%, $(AAT)_{14}$ 21.6%, $(AAT)_{12}$ 18.5%, and $(AAT)_{7}$ 11.1%. The frequency of the repeat alleles in the control group (in the decreasing order) was as follows : $(AAT)_{13}$ 31.6%, $(AAT)_{14}$ 24.5%, $(AAT)_{12}$ 17.2%, and $(AAT)_{7}$ 11.6%. However, there were no significant differences in the AAT-repeat polymorphisms of the CNR1 gene between the patient group and the control group. Conclusions Although our study revealed no significant association of the AAT-repeat polymorphism of the CNR1 gene with schizophrenia, it will serve as a good reference for future studies designed to examine the cannabinoid hypothesis of schizophrenia.

An effectiveness of multitransmit parallel technique on scan time reduction in hip joint MRI (고관절 자기공명영상 검사 시 multitransmit 기법의 적용에 따른 검사시간 단축의 유용성)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.103-108
    • /
    • 2016
  • This study examined the effectiveness of the multitransmit parallel technique on the MRI scan time reduction by removing the dielectric effect. The T1 and T2 weighted images of the patients' hip joint were acquired with and without a multitransmit technique. The ROIs were located in the head of femur and iliopsoas muscle. The SNR, CNR and scan time were measured and compared. There was no difference in the images with and without multitransmit. In contrast, the acquisition time was decreased by 42.8% in T1WI and 49.7% in T2WI. In conclusion, this study demonstrated that significant scan time reductions can be accomplished without any differences in the image quality in hip joint MRI by applying the multitransmit parallel technique. Furthermore, the multitranstmit technique is useful in other body parts to resolve the long scan time of an MRI examination.

Effect of Electron Accepters on Step-up Photophobic Responses of Blephalisma japonicum

  • Youssef, Tareq;Angelini, Nicola;Gioffre, Domenico;Sgarbossa, Antonella;Lenci, Francesco
    • Journal of Photoscience
    • /
    • v.7 no.1
    • /
    • pp.1-4
    • /
    • 2000
  • The photosensory ciliates Blepharisma japonicum and Stentor coeruleus use the hypericin-derived pigments blepharismin and stentorin, respectively, as photoreceptor chromophores. Fluorescence quenching studies have shown that the first excited singlet state of hypericin and the purified chromophores blepharismin and stentorin can be deactivated by electron transfer to an acceptor molecule with a suitable reducing potential [1,2]. This paper reports the result of a series of photobehavioral experiments performed with the aim to ascertain if the same electron accepters which quench the photoreceptor pigment fluorescence in vitro may also compete with the native acceptor molecule in its natural physiological environment. Individual cell trajectories were examined before and after light stimulation, in the presence and in the absence of potential "in vivo" electron accepters, with a microvideo-recording apparatus. Our data, on Blepharisma cells, showed that as the negative reduction potential of the electron acceptor increases, a pronounced decrease in cell photoresponsiveness was detected. A dramatic effect on cell photoresponsiveness was noticed in the presence of 1,4-benzoquinone that has the lowest negative reduction potential. Such an effect on the percentage of photoreacting cells was moderate in the case of 1,4-naphthoquinone, with a relatively higher negative reduction potential. In the presence of benzophenone, which has the highest negative reduction potential, no significant effect on photoreacting cells was noticed. Our results can support the hypothesis that in the pigment granules such a light-induced charge transfer from excited blepharismin to a suitable electron acceptor triggers sensory transduction processes in B. japonicum.

  • PDF

Evaluation of Usefulness of IDEAL(Iterative decomposition of water and fat with echo asymmetry and least squares estimation) Technique in 3.0T Breast MRI (3.0T 자기공명영상을 이용한 유방 검사시 IDEAL기법의 유용성 평가)

  • Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.2
    • /
    • pp.217-224
    • /
    • 2010
  • The purpose of this study was to examine the usefulness of IDEAL technique in breast MRI by performing a quantitative comparative analysis in patients diagnosed with DCIS. On a 3.0T MR scanner, fat-suppressed T2-weighted images and T1-weighted images before and after contrast enhancement were obtained from 20 patients histologically diagnosed with ductal carcinoma in situ (DCIS). The findings from the quantitative image analysis are the following: 1) On T2-weighted images, SNR were not significantly different in the lesion area itself between the CHESS and IDEAL groups, while the IDEAL group showed higher SNR at the ductal area and fat area than the CHESS group. In addition, the CNR were higher for the IDEAL group in those regions. 2) On T1-weighted images before enhancement, SNR were not significantly different in the lesion area itself between the CHESS and IDEAL groups, while the IDEAL group showed higher SNR at the ductal area and fat area than the CHESS group. In addition, the CNR were higher for the IDEAL group in those regions. 3) On T1-weighted images after enhancement, SNR were not significantly different in the lesion area itself between the CHESS and IDEAL groups, while the IDEAL group showed higher SNR at the ductal area and fat area than the CHESS group.

Optimizations of 3D MRI Techniques in Brain by Evaluating SENSE Factors (삼차원 자기공명영상법의 뇌 구조 영상을 위한 최적화 연구: 센스인자 변화에 따른 신호변화 평가)

  • Park, Myung-Hwan;Lee, Jin-Wan;Lee, Kang-Won;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.161-170
    • /
    • 2009
  • Purpose : A parallel imaging method provides us to improve temporal resolution to obtain three-dimensional (3D) MR images. The objective of this study was to optimize three 3D MRI techniques by adjusting 2D SESNE factors of the parallel imaging method in phantom and human brain. Materials and Methods : With a 3 Tesla MRI system and an 8-channel phase-array sensitivity-encoding (SENSE) coil, three 3D MRI techniques of 3D T1-weighted imaging (3D T1WI), 3D T2-weighted imaging (3D T2WI) and 3D fluid attenuated inversion recovery (3D FLAIR) imaging were optimized with adjusting SESNE factors in a water phantom and three human brains. The 2D SENSE factor was applied on the phase-encoding and the slice-encoding directions. Signal-to-noise ratio(SNR), percent signal reduction rate(%R), and contrast-to-noise ratio(CNR) were calculated by using signal intensities obtained in specific regions-of-interest (ROI). Results : In the phantom study, SENSE factor = 3 was provided in 0.2% reduction of signals against without using SENSE with imaging within 5 minutes for 3D T1WI. SENSE factor = 2 was provided in 0.98% signal reduction against without using SENSE with imaging within 5 minutes for 3D T2WI. SENSE factor = 4 was provided in 0.2% signal reduction against without using SENSE with imaging around 6 minutes for 3D FLAIR. In the human brain study, SNR and CNR were higher with SENSE factors = 3 than 4 for all three imaging techniques. Conclusion : This study was performed to optimize 2D SENSE factors in the three 3D MRI techniques that can be scanned in clinical time limitations with minimizing SNR reductions. Without compromising SNR and CNR, the optimum 2D SENSE factors were 3 and 4, yielding the scan time of about 5 to 6 minutes. Further studies are necessary to optimize 3D MRI techniques in other areas in human body.

  • PDF

An Assessment of the Usefulness of Time of Flight in Magnetic Resonance Angiography Covering the Aortic Arch

  • Yoo, Yeong-Jun;Choi, Sung-Hyun;Dong, Kyung-Rae;Ji, Yun-Sang;Choi, Ji-Won;Ryu, Jae-Kwang
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.325-332
    • /
    • 2018
  • Carotid angiography covering the aortic arch includes contrast-enhanced magnetic resonance angiography (CEA), which is applied to a large region and usually employs contrast media. However, the use of contrast media can be dangerous in infants, pregnant women, and patients with chronic renal failure (CRF). Follow-up patients informed of a lesion may also want to avoid constant exposure to contrast media. We aimed to apply time-of-flight (TOF) angiography to a large region and compare its usefulness with that of CEA. Ten patients (mean age, 58 years; range, 45~75 years) who visited our hospital for magnetic resonance angiography (MRA) participated in this study. A 3.0 Tesla Achieva magnetic resonance imaging (MRI) system (Philips, Netherland) and the SENSE NeuroVascular 16-channel coil were employed for both methods. Both methods were applied simultaneously to the same patient. Three TOF stacks were connected to cover the aortic arch through the circle of Willis, and CEA was applied in the same manner. For the quantitative assessment, the acquired images were used to set the regions of interest (ROIs) in the common carotid artery (CCA) bifurcation, internal carotid artery, external carotid artery, middle cerebral artery, and vertebral artery, and to obtain the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) for the soft tissues. Three radiologists and one radiological resident performed the qualitative assessment on a 5-point scale - 1 point, "very bad"; 2 points, "bad"; 3 points, "average"; 4 points, "good"; and 5 points, "very good" - with regard to 4 items: (1) sharpness, (2) distortion, (3) vein contamination, and (4) expression of peripheral vessels. For the quantitative assessment, we estimated the mean SNR and CNR in each of the 5 ROIs. In general, the mean SNR was higher in TOF angiography (166.1, 205.2, 154.39, 172.23, and 161.95) than in CEA(92.05, 95.43, 84.76, 73.69, and 88.3). Both methods had a similar mean CNR: 67.62, 106.71, 55.9, 73.74, and 63.46 for TOF angiography, and 67.82, 71.19, 60.52, 49.45, and 64.07 for CEA. In all ROIs, the mean SNR was statistically significant (p<0.05), whereas the mean CNR was insignificant (p>0.05). The mean values of TOF angiography and CEA for each item in the qualitative assessment were 4.2 and 4.28, respectively for item 1; 2.93 and 4.55, respectively, for item 2; 4.6 and 3.13, respectively, for item 3; and 2.88 and 4.65, respectively, for item 4. Therefore, TOF angiography had a higher mean for item 3, and CEA had a higher mean for items 2 and 4; there was no significant difference between the two methods for item 1. The results for item 1 were statistically insignificant (p>0.05), whereas the results for items 2~4 were statistically significant (p<0.05). Both methods have advantages and disadvantages and they complement each other. However, CEA is usually applied to a large region covering the aortic arch. Time-of-flight angiography may be useful for people such as infants, pregnant women, CRF patients, and followup patients for whom the use of contrast media can be dangerous or unnecessary, depending on the circumstance.

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

Evaluation of Image Quality according to Insert Position and Thickness Change by Fabricating Modified ACR Phantom in Mammography (유방엑스선검사에서의 변형된 ACR 팬텀 제작을 통한 모조병소의 위치와 두께 변화에 따른 영상의 품질 평가)

  • Uhm, Hyon-Ja;Park, Chanrok
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.103-109
    • /
    • 2022
  • To maintain improved image quality in mammography, the quality control process is performed using the ACR (American college of radiology) phantom. In addition, many studied were performed by fabricating the customized breast phantom to provide more information in mammography. Thus, the purpose of this study was to evaluate the image quality by designing the modified ACR phantoms. The five modified acrlylic ACR phantoms were designed by considering insert position and phantom thickness. The phantoms were consisted of 4.5, 3.0, and 1.5 cm in terms of phantom thickness, and 3.0, 2.0, and 0.5 cm in terms of insert position, respectively. The acquired images were evaluated by PSNR (peak signal to noise ratio), RMSE (root mean square error), CC (correlation coefficient), CNR (contrast to noise ratio), and COV (coefficient of variation). Based on the similarity analysis, the result is suitable between conventional and new designed phantoms. In addition, the CNR and COV results in terms of insert position showed that image quality for 0.5 cm was 2.3 and 27.4% improved compared with 2 and 3 cm, respectively. According to phantom thickness results, the CNR result for 1.5 cm and COV result for 4.5 cm were 50.1 and 62.7% improved compared with that those conditions. In conclusion, we confirmed that the image quality depends on the breast size and thickness through modified ACR phantom study.

A Study on the Change of Image Quality According to the Change of Tube Voltage in Computed Tomography Pediatric Chest Examination (전산화단층촬영 소아 흉부검사에서 관전압의 변화에 따른 화질변화에 관한 연구)

  • Kim, Gu;Kim, Gyeong Rip;Sung, Soon Ki;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.503-508
    • /
    • 2019
  • In short a binary value according to a change in the tube voltage by using one of VOLUME AXIAL MODE of scanning techniques of chest CT image quality evaluation in order to obtain high image and to present the appropriate tube voltage. CT instruments were GE Revolution (GE Healthcare, Wisconsin USA) model and Phantom used Pediatric Whole Body Phantom PBU-70. The test method was examined in Volume Axial mode using the pediatric protocol used in the Y university hospital of mass-produced material. The tube voltage was set to 70kvp, 80kvp, 100kvp, and mAs was set to smart mA-ODM. The mean SNR difference of the heart was $-4.53{\pm}0.26$ at 70 kvp, $-3.34{\pm}0.18$ at 80 kvp, $-1.87{\pm}0.15$ at 100 kvp, and SNR at 70 kvp was about -2.66 higher than 100 kvp and statistically significant (p<0.05) In the Lung SNR mean difference analysis, $-78.20{\pm}4.16$ at 70 kvp, $-79.10{\pm}4.39$ at 80 kvp, $-77.43{\pm}4.72$ at 100 kvp, and SNR at 70 kvp at about -0.77 higher than 100 kvp were statistically significant. (p<0.05). Lung CNR mean difference was $73.67{\pm}3.95$ at 70 kvp, $75.76{\pm}4.25$ at 80 kvp, $75.57{\pm}4.62$ at 100 kvp and 20.9 CNR at 80 kvp higher than 70 kvp and statistically significant (p<0.05) At 100 kvp of tube voltage, the SNR was close to 1 while maintaining the quality of the heart image when 70 kvp and 80 kvp were compared. However, there is no difference in SNR between 70 kvp and 80 kvp, and 70 kvp can be used to reduce the radiation dose. On the other and, CNR showed an approximate value of 1 at 70 kvp. There is no difference between 80 kvp and 100 kvp. Therefore, 80 kvp can reduce the radiation dose by pediatric chest CT. In addition, it is possible to perform a scan with a short scan time of 0.3 seconds in the volume axial mode test, which is useful for pediatric patients who need to move or relax.

Comparison of Exposure Dose by Using AEC Mode of Abdomen AP Study in Radiography (복부 전후 방향 검사의 자동노출제어 사용 시 선량 비교 연구)

  • Kim, Ki-Won;Kwon, Yong-Rak;Seo, Seong-Won;Kwon, Kyung-Tae;Oh, Joo-Young;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.205-211
    • /
    • 2015
  • We evaluated the effectiveness of TL (Time Limit) method by comparing with NTL (Non-time limit) method when it is used for examinations for abdomen Anterior Posterior (AP) in this paper. The evaluation was conducted based on the comparison of dose, and of signal to noise ratio (SNR) and contrast to ratio (CNR) on both methods. The experiments were conducted with XGEO GC 80 (Samsung, Korea), Unfors ThinX RAD (Unfors, Sweden) and Rando Phantom (Alderson research laboratories, USA) and shielding material with the size of $5.5{\times}9{\times}0.1cm^3$. It was set to activate only two upper ionization chambers in automatic exposure control(AEC) mode and the tube-voltage was set to 80kVp. When the exposure time was limited, it is limited to 51 msec. The images both by NTL AEC method and TL AEC method were acquired when with and without attachment of shielding material on the upper ionization chambers. The images were evaluated by SNR and CNR which are the image evaluation methods using 'Image J'. The NTL AEC method showed increases in dose as much as 130.7% at maximum and 80% at minimum than other methods. The TL AEC method showed decreases in mAs and exposure dose than the NTL AEC method as much as 43.8% and 44.4% respectively. There were no significant differences in SNR or CNR for the experiments (($p{\geq}0.05$). Therefore, it is suggested that the TLAEC mode is more effective when examining patients who have high BMI index or a patient with a metallic substance in the body after surgery.