SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화 (Variation on Estimated Values of Radioactivity Concentration according to the Change of the Acquisition Time of SPECT/CT)

  • 김지현;박훈희;이주영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.645-653
    • /
    • 2021
  • With the recent development of precision medicine(Theranostics), interest and utilization of the quantitative function of SPECT/CT are increasing. This study aims to investigate the effect on the radioactivity concentration estimate by the increase or decrease in the total time of SPECT/CT imaging conditions. A standard image was obtained by the conditions of a total acquisition time of 600 sec(10 sec/f × 120 frames) by diluting 99mTc 91.76 MBq in a cylindrical phantom filled with sterile water, and a comparative image was obtained by increasing the total acquisition time by -90%, -75%, -50%, -25%, +50%, +100%. The CNR, radioactive concentration estimate(cps/ml), and the variation rate(%) of the recovery coefficient(RC) were analyzed by measuring the overall coefficient of interest in each image. The results[CNR, Radiation Concentration, RC] by the change in the number of projections for each increase or decrease rate(-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results[CNR, Radiation Concentration, RC] by the acquisition time change for each increase or decrease rate(-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at -90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Image quality(CNR) showed a pattern of change in proportion to the increase or decrease in the total acquisition time of SPECT/CT, but the result at quantitative evaluation showed a change of less than 5% in all experimental conditions, maintaining quantitative accuracy(RC less than 0.05) without much influence.

Prediction of hub genes of Alzheimer's disease using a protein interaction network and functional enrichment analysis

  • Wee, Jia Jin;Kumar, Suresh
    • Genomics & Informatics
    • /
    • 제18권4호
    • /
    • pp.39.1-39.8
    • /
    • 2020
  • Alzheimer's disease (AD) is a chronic, progressive brain disorder that slowly destroys affected individuals' memory and reasoning faculties, and consequently, their ability to perform the simplest tasks. This study investigated the hub genes of AD. Proteins interact with other proteins and non-protein molecules, and these interactions play an important role in understanding protein function. Computational methods are useful for understanding biological problems, in particular, network analyses of protein-protein interactions. Through a protein network analysis, we identified the following top 10 hub genes associated with AD: PTGER3, C3AR1, NPY, ADCY2, CXCL12, CCR5, MTNR1A, CNR2, GRM2, and CXCL8. Through gene enrichment, it was identified that most gene functions could be classified as integral to the plasma membrane, G-protein coupled receptor activity, and cell communication under gene ontology, as well as involvement in signal transduction pathways. Based on the convergent functional genomics ranking, the prioritized genes were NPY, CXCL12, CCR5, and CNR2.

Chest CT에서 Care Dose 4D+Care kV에 따른 화질과 입사표면선량 비교 (Comparisons of Image Quality and Entrance Surface Doses according to Care Dose 4D + Care kV in Chest CT)

  • 강은보
    • 한국방사선학회논문지
    • /
    • 제16권1호
    • /
    • pp.45-51
    • /
    • 2022
  • 본 연구는 Chest CT에서 Care Dose 4D+Care kV System을 사용하여 촬영할 때와 CARE DOSE 4D 기능만을 사용했을 때, 그리고 Care Dose 4D와 관전압을 각각 80 kVp, 100 kVp, 120 kVp, 140 kVp로 변화를 주고 검사했을 때의 DLP값과 팬텀의 입사표면선량, 화질을 비교하여 최소의 선량으로 가장 최상의 화질을 유지할 수 있는 방법을 찾아보고자 하였다. DLP값은 Chest Care Dose 4D + Care kV semi 100으로 촬영하였을 때 6.727%, Chest Care Dose 4D + Care kV 로 촬영하였을 때 6.481% 감소하는 것으로 나타났다. Chest Non을 기준으로 입사표면선량에서 Chest Care Dose 4D + Care kV semi 100으로 검사하였을 때 16.519%, Chest Care Dose 4D + Care kV 로 검사하였을 때 15.705% 감소하는 것으로 나타났다. 영상의 화질에 대한 비교에서 Chest Non과 비교해서 Care Dose 4D + Care kV를 포함한 모든 촬영조건에서 SNR값과 CNR값을 비교한 결과 P>0.05로 유의한 차이가 없는 것으로 나타났다. Chest CT에서 Chest Care Dose 4D + Care kV를 사용해서 촬영한 결과 수동으로 kV와 mAS를 조정해서 얻은 최상의 조건의 결과 값과 비슷하게 피폭선량이 감소한 것으로 나타났으며, 영상의 SNR과 CNR에서도 유의한 차이가 없는 것으로 나타났다. Chest Care Dose 4D + Care kV 기능을 사용한다면 영상의 화질을 유지하면서 환자피폭을 줄일 수 있는 좋은 방법이라 생각된다.

NECT CT에서 DLIR 재구성기법 적용 시 화질분석 (Image Quality Analysis when applying DLIR Reconstruction Techniques in NECT CT)

  • 윤준;김현주
    • 한국방사선학회논문지
    • /
    • 제16권4호
    • /
    • pp.387-394
    • /
    • 2022
  • 갑상샘이 포함된 인체모형 팬텀을 이용하여 임상에서 많이 적용하는 NECK CT 프로토콜 중 관전압을 변화 적용하여 스캔 후 Raw data를 이용하여 FBP, ASIR-V, DLIR 재구성기법 적용 영상 획득하여 120 kVp FBP 재구성 영상 기준 DLIR 재구성기법의 유용성을 알아보았다. 그 결과 DLIR 재구성기법 적용 시 CTDIvol 이 감소하였으며, 특히 동일 관전압에서 FBP 적용보다 ASIR-V, DLIR 재구성 시 낮은 선량에서도 기준 스캔 조건으로 획득한 화질에 도달하였다. 또한, SNR, CNR 분석결과 DLIR 재구성 영상이 SNR, CNR 값이 높게 분석되었고, SSIM분석결과 100 kVp, DLIR 재구성 영상이 SSIM 지수가 1에 근사하게 측정되어 원본 영상에 대한 재구성 영상의 유사도가 높은 것으로 분석되었다(p>0.05). 본 연구결과를 활용하여 임상 영상 평가를 시행하여 보완하고 다양한 해부학적 구조에 적용 가능한 알고리즘을 추가 개발한다면 검사 선량을 현재 보다 낮추면서 화질을 유지할 수 있어 임상 적용 시 유용할 것으로 생각된다.

뇌종양 확산강조영상에서 High B-value의 유용성 평가 (Usefulness of the High B-value DWI in Brain Tumors)

  • 김진태;변재후;박용성;이래곤;황선광
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.33-41
    • /
    • 2015
  • This study attempts to examine the clinical usefulness of High b-value DWI (diffusion weighted imaging) for brain tumors with an edema. Subjects were seven patients selected from 65 patients who received an MRI scan for suspected encephalopathy and confirmed diagnosis at our hospital from February to July 2015 (male: 7, average age : 66 years old). As test equipment, 3.0T MR System (ACHIEVA Release, Philips, Best, The Netherlands) and 8Channel SENSE Head Coill were used. DWI checks on the use of the variable TR 5460ms, TE 132ms, Slice Thickness 4mm, gap 1mm, Slice number 29 is, 3D T1WI is TR 8.4ms, TE 3.9ms, matrix size $240{\times}240$, Slice can set 180 piecesIt was. b value of 0, 1,000, 2,000 s/mm2 with DWI acquisition and 3D T1WI enhancement five minutes after the Slice Thickness 3mm, gap 0mm to reconstruct the upper face axis (MPR TRA CE) was. As for the experiment, in b-value 1,000 and 2,000 images, SNR and the lesion at the lesion site and CNR in the normal site opposite to the lesion are measured. WW(window width) and WL(window level) are made equal in MRICro software, and the volume of the lesion is measured from each of b-value and MPR TRA CE image. Using SPSS ver. 1.8.0.0 Mann Whitney-test was analyzed for SNR and CNR, while Kruskal-Wallis test was analyzed for volume.

  • PDF

미세 대조도 영상을 기반한 디지털 방사선 영상 시스템의 자동노출제어 조절인자 간의 상관관계 분석 (Correlation Analysis of Control Factors in Automatic Exposure Control of Digital Radiography System Based on Fine Contrast Images)

  • 임세훈;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.1-8
    • /
    • 2021
  • The purpose of this study was to analyze the effect of automatic exposure control (AEC) control factors in digital radiography systems based on the fine contrast images using coin phantoms. The AEC control factors were targeted at the range of dominent zone, sensitivity, and density. The dominent zone was divided into cases where a single coin was used to cover the field configuration, and cases where seven coins were used to cover the field configuration. The sensitivity was classified into three stages (200, 400, 800) and the density was classified into three stages (2.5, 0, 2.5). Image quality was evaluated by signal to noise ratio (SNR) and contrast to noise ratio (CNR). Then, the automatically exposed tube current was measured. As a result, the X-ray image of seven coins obtained a result value of about 1.2 times higher for SNR and 1.9 times higher for CNR than the X-ray image for one coin. The tube current was also about 1.6 times higher. In conclusion, In AEC, the higher the field configuration and dominent zone are matched and the higher the density, the lower the sensitivity, which increases the tube current and CNR, which increases the image quality. Therefore, it is judged that the appropriate setting of the range of dominent zone, sensitivity, and density of the control, which is the AEC control factor, could improve the fine contrast of images.

국소 간 병변의 발견: 1.5-T 자기공명영상에서의 자유호흡과 호흡유발 확산강조 영상의 비교 (Detection of Hepatic Lesion: Comparison of Free-Breathing and Respiratory-Triggered Diffusion-Weighted MR imaging on 1.5-T MR system)

  • 박혜영;조현제;김은미;허감;김용훈;이병훈
    • Investigative Magnetic Resonance Imaging
    • /
    • 제15권1호
    • /
    • pp.22-31
    • /
    • 2011
  • 목적: 이 연구의 목적은 간 병변 발견에 있어 1.5-T 자기공명영상에서 자유 호흡 확산강조 영상과 호흡 유발 확산강조 영상의 유용성을 비교하는데 있다. 대상 및 방법: 47명의 환자(평균 57.9세, 남성:여성 = 25:22)가 한번의 간 자기공명 영상검사에서 자유호흡 확산 강조 영상과 호흡유발 확산 강조 영상을 동시에 시행하였다. 이를 두 명의 영상의학과 의사가 호흡유발 이미지 세트(B50, B400, B800 확산강조 영상과 ADC map)와 자유호흡 이미지 세트를 2주간의 시간 간격을 두고 무작위로 후향적 분석을 시행하였다. 영상분석을 위하여 특정영역(ROI)를 설정한 후에 간의 신호대 잡음비 (signal-to-noise ratio, SNR)와 대조도(contrast-to-noise ratio, CNR)를 계산하였다. 결과: 32개의 낭종, 13개의 혈관종, 7개의 간세포암, 6국소 호산구성 간질환, 2개의 전이, 1개의 초점성 결절성 과증식과 글리슨막의 가성지방종을 포함하는 총 62개의 병변이 두 명의 평가자에 의하여 분석되었다. 비록 통계적 유의성을 없었으나, 전체적인 병변 발견의 sensitivity는 호흡유발 확산강조 영상이 [평가자 1:평가자 2, 47/62(75.81%):45/62(72.58%)] 자유호흡 확산강조 영상보다 [44/62(70.97%):41/62(66.13%)] 더 높은 수치를 보였다. 특히 1 cm보다 작은 국소 간 병변 발견의 sensitivity는 호흡유발 확산강조 영상이 [24/30(80%): 21/30(70%)] 지유호흡 확산강조 영상보다 [17/30(56.7%):15/30(50%)] 더 우월하였다. 진단적 정확도활 계산하기 위하여 ROC curve (Az value)를 구하였으며 자유호흡 확산강조 영상과 호흡유발 확산강조 영상간에는 통계적 차이는 없었다. 간의 신호대 잡음비 (SNR)와 대조도 (CNR)는 호흡유발 확산강조 영상이 ($87.6{\pm}41.4$, $41.2{\pm}62.5$) 자유호흡확산강조 영상보다 ($38.8:{\pm}13.6$, $24.8{\pm}36.8$) 높았으며 통계적인 유의성이 있었다. (p value < 0.001). 결론: 1.5-T자기공명 시스템서 1 cm보다 작은 간 병변발견에 있어서 호흡유발 확산강조 영상이 자유호흡 확산강조 영상보다 좋으며 이는 호흡유발 확산강조 영상이 높은 신호대 잡음비 (SNR)와 대조도(CNR)를 보이기 때문이다.

호흡정지 T1 강조 간 자기공명영상에서 동위상 역위상 FMPSPGR 영상의 비교 (Comparison of In-Phase and Opposed-Phase FMPSPGR Images in Breath-hold T1-weighted MR IMaging of Liver)

  • 김명진;김만득;정재준;이종태;유형식
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.142-147
    • /
    • 1997
  • 목적: 호흡정지 간 자기공영상에서 국소 간 병변을 발견함에 있어 동위상(inphase) 방식과 역위상(opposed-phase) 방식의 fast multiplanar spoiled gradient recalled(FMPSPGR) 영상간의 효율성을 비교하고자 하였다. 대상 및 방법: 다른 검사를 통해 국소 간 병변이 발견되었거나 의심되었던 45명의 환자의 78개의 병변에 대한 고속경사에코대열의 동위상과 역위상 영상을 비교하였다. 병변 발견률을 평가하기 위해 세 명의 사전 정보 없는 판독의가 독립적으로 영상을 검토하였다. 간의 신호대잡음비, 병변과 간의 대조대잡음비 및 간과 비장 간 대조대잡음비를 비교하였다. 세 명의 동의에 의해 어느 대열에서 영상의 질이 더 나은지 결정하였다. 결과: 역위상 영상에서 판독의 1, 2, 3이 각각 61(78%), 61(78%), 및 63(89%)개의 병변을 정확히 발견하였다. 동위상 영상에서 각 판독의가 66(85%), 65(83%) 및 65(93%)개의 병변을 발견하였다. 두 영상을 조합하였을 때, 71(91%), 69(88%) 및 76(97%)개의 병변이 각각 발견되었다. 간세포암이 증례에서 간-병변간 대조대잡음비는 역위상 영상에서 더 컸으나(p<0.05), 다른 병변에서의 의미 있는 차이는 보이지 않았다. 간-비장간 대조잡음비는 역위상 영상에서 높았으나(p<0.1), 간의 신호대잡음비는 동위상 영상에서 더 높았다. 결론: 국소적 간 병변을 놓치지 않고 발견 하기 위새서는 동위상 영상과 역위상 영상을 모두 이용하는 것이 바람직하다.

  • PDF

조영제 주입 전 1.5T 와 3.0T를 이용한 복부장기 자기공명영상에서 영상의 질 비교 (Comparison of Image Quality in Magnetic Resonance Imaging of the Abdominal Organ at 1.5T and 3.0T before the Gadolinium Injection)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.619-625
    • /
    • 2017
  • 본 연구는 조영제 주입 전 복부 검사 시 필수적으로 적용되고 있는 HASTE, HASTE(f/s), FFE(in, out)를 중심으로 두 기기에 대한 복부장기의 신호 대 잡음비(SNR; Signal to Noise Ratio)와 대조도 대 잡음비(CNR; Contrast to Noise Ratio)를 정량적으로 평가함으로서 최적의 장비선택을 알아보고자 하였다. 데이터분석은 1.5T 와 3.0T 자기공명영상기기(Philips medical system, Netherland)를 이용하여 검사한 복부영상을 무작위로 선정하여 분석을 하였다. 정량적 분석결과 간(Liver), 신장(Kidney), 비장(Spleen)에서는 1.5와 비교했을 때 3.0T가 SNR, CNR 값이 높게 나타났고(p<0.05), 위(Stomach), 복부지방(Abdominal Fat), 췌장(Pancreas)에서는 1.5T 가 높은 결과를 얻었다(p<0.05). 결론적으로 두기기별 장기에 대한 정량적 평가를 했을 때 인체의 바같 부분 조직은 전반적으로 3.0T 가 높게 나타났고 가스를 포함하여 자화율의 차이를 많이 발생시키는 안쪽부분의 장기는 1.5T 가 높은 결과를 얻었다. 이러한 결과는 환자상태에 따라 조영제를 사용하지 못하고 MRI 검사를 하는 경우 정확한 진단학적 정보를 제공하는데 가이드라인이 될 것이다.

Aortic arch를 포함한 Carotid angio 검사 시 Time of flight(TOF)의 유용성 평가 (Usefulness estimating of Time of flight(TOF) during Carotid angio inspection including Aortic arch)

  • 유영준
    • 대한디지털의료영상학회논문지
    • /
    • 제15권1호
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose : The Carotid Angio inspection including Aortic arch applied to wide area is conducted as the Contrast Enhance MR Angiography(CEA) which is using a contrast medium. However it is a burden not only for someone such as infants, pregnant women and patients suffering from kidney failure but continuous use of contrast medium also can be a burden for patients who has been taken follow up inspection since diagnose lesion already. The purpose of this study is to estimate a usefulness of the Time of Flight (TOF) by comparing with CEA. Materials and methods : 10 patients with an average age of 58 (from 45 to 75) who had MRA inspection in our hospital were studied using 3.0 Tesla Aachieva (Philips, Netherland) MRI system and Sense Neuro-Vascular 16 Channels Coil. The same patient was inspected both TOF and CEA simultaneously. The TOF inspection included from Aortic arch to Willis Circle by connecting 3 TOF stacks and so did CEA inspection. The quantitative analysis was conducted through signal to noise ratio(SNR) and contrast to noise ratio(CNR) with soft tissue by setting up an area of interest on CCA bifurcatoin, ICA, ECA, MCA and VA concerning obtained image. In case of qualitative analysis, 3 radiological technologists and 1 radiologist evaluated 4 items (1: Visibility of the blood vessel, 2: Image distortion measure, 3: Overlapping measure with vein, 4: Peripheral blood vessel description measure) into five points scale (1: Very bad, 2: Bad, 3: Normal 4: Good, 5: Very good). Results : Results for the quantitative analysis was obtained by calculating the average of 5 ROIs in case of SNR and CNR separately. Results of SNR, TOF were generally measured higher than CEA (In case of TOF were 166.1, 205.2, 154.39, 172.23, 161.95, and CEA were 92.05, 95.43, 84.76, 73.69, 88.3). But according to the result of CNR, both TOF and CEA were measured similarly as 67.62, 106.71, 55.9, 73.74, 63.46 for TOF and 67.82, 71.19, 60.52, 49.45, 64.07 for CEA. Throughout every results of each ROI, SNR showed statistically meaningful consequence (0.050.05). In case of qualitative analysis the average of each evaluated item was 4.2points and 4.28points in the item1, 2.93points and 4.55points in the item2, 4.6points and 3.13points in the item3, 2.88points and 4.6points in the item4. According to the results TOF was measured higher in the item3 while in the item2 and item4 CEA was higher and in case of the item1, both CEA and TOF were similar. To sum up statistically meaningful results (p<0.05) were shown in the item2, item3 and item4 but not in the item1 (p>0.05). Conclusions : Both TOF and CEA are complementary because each inspection has pros and cons, but when inspect wide area including Aortic arch normally CEA is conducted. But TOF inspection also can be considered as alternative in terms of patients who has difficulty in the contrast medium such as infants, pregnant women and patients suffering from kidney failure and patients during follow up.

  • PDF