• 제목/요약/키워드: CM산업

검색결과 787건 처리시간 0.025초

슬랙스의 무릎절개선 활용에 따른 의복압 및 착용감 (Clothing Pressure and Subjective Sensations in Slacks using the Cutting Lines of the Knee Parts)

  • 이정숙;성수광
    • 한국의류산업학회지
    • /
    • 제6권1호
    • /
    • pp.109-113
    • /
    • 2004
  • The present study attempted to consider the effects of cutting lines in the knee parts of slacks on the clothing pressure and comfort. The study compared and analyzed the pressure imposed to the body in a stooping position and the consequent sensations felt by the wearer according to the slack shapes. The conclusion was drawn as follows: The pressure imposed by the slacks to the body is greater on the two points slightly upper and lower from the knee point than on the knee point itself, regardless of the slack shapes. Clothing pressure was lower in the slacks with 10 cm-wide and 14 cm-wide cutting lines in the knee parts than those with 18 cm-wide cutting lines. Subjective sensations felt in the knee parts were analyzed according to slacks shapes. As a result, it was found that slacks without cutting lines on the knee parts or with sewing lines far from the knee points were more comfortable. In slacks construction, the use of cutting lines in the knee parts can decrease pressure imposed to the knee area or improve the comfort of the slacks. When designing slacks, however, overall appearance should be considered and the weakness of cutting line that makes legs look shorter should also be complemented.

요인 실험분석에 의한 SB 라텍스 개질 콘크리트의 강도예측 (Strength Estimation of Stylene-Butadien Latex Modified Concrete by Factorial Experimental Design)

  • 윤경구;이주형;홍창우
    • 산업기술연구
    • /
    • 제21권B호
    • /
    • pp.307-315
    • /
    • 2001
  • The purpose of this study was to provide the evaluation and prediction of strengths of SB latex modified concrete(LMC) using a statistical method and factorial experimental design method. The main experimental variables were as follows ; W/C ( 4 levels ; 31, 33, 35, 42%), S/a( 2 levels ; 55, 58%) and L/C(2 levels ; 5, 15%). The compressive strength and flexural strength of LMC were selected as a factor of response. The statistical method was carried out to analyze the results, together with factorial experimental design method and response surface method. The analysis showed that if L/C had been 15%, W/C appeared to be around 33% to achieve the design strength of $350kgf/cm^2$. In this case, the flexural strength and the slump came to around $68kgf/cm^2$ and 18cm, respectively. Eventhough the L/C varied, the design strength and W/C could be predictable together with slump value and flexural strength. As a result of series of experiments in this study, W/C and L/C were proved to be the main factors influencing on the compressive and flexural strength of LMC. Both of strength and slump values could be predictable from the mixing proportion of LMC.

  • PDF

발파진동 제어에 의한 특수구간 터널굴착에 관한 연구 (A Study on Tunnel Excavation by Controlled Blast Vibration at Particular Environment Conditions)

  • 최형빈;임한욱
    • 산업기술연구
    • /
    • 제20권A호
    • /
    • pp.257-267
    • /
    • 2000
  • It was difficult to apply conventional excavation methods in some sections from Seoul to Pusan high speed rail road construction of 1 lot 2, due to highway concrete road, gas pipe, water pipe and nearby factories with automatic control system machine. To excavate safely and efficiently in these sections new blast patterns were employed within allowable blast vibration level, by test blast and controlled vibration by sequential blast. Behaviors of the rock mass including convergence and displacement around tunnel were measured with construction works and the crack width in concrete wall was also monitored for controlling allowable limits. The results can be summarized as follow : 1. The allowable blast vibration level in structure site is less 1.0cm/sec for highway concrete, 0.5 cm/sec for gas pipe, water pipe and building housing and 0.3 cm/sec for automatic control system machine. 2. The convergence displacement, single rod extensometer and multi rod extensometer around tunnel and cracks in concrete wall were measured, it was confirmed that the measured values were converged within allowable level. 3. The empirical formular of ground vibrations with 90% confidence lines for PD-3 was given as follow. $$V_{90%}=45.549({\frac{D}{\sqrt{W}}})^{-1.353}$$

  • PDF

VDT 모니터링 작업에서 근골격계 부담도 및 선호도에 근거한 모니터 높이 결정 (Determination of Proper Monitor Height based on the Musculoskeletal Load and Preference during VDT Monitoring Tasks)

  • 이중호;송영웅;나석희;정민근
    • 대한산업공학회지
    • /
    • 제32권3호
    • /
    • pp.236-241
    • /
    • 2006
  • Monitor height is one of the key factors in the VDT workstation design. Most of the previous studies have focused on traditional VDT workplace where the operators performed data entry or word processing tasks using single monitor. This study aimed to suggest proper monitor height when the main task was monitoring information from different number of information sources. Twelve male students participated in three experiments: single information source (one monitor), two information sources (one monitor and one CCTV), and three information sources (one monitor, one CCTV and a window). Subjects performed monitoring tasks for 10 minutes with 3 different monitor center heights : 89.0 cm (Low), 111.3 cm (Middle), and 124.8 cm (High). Surface EMG signals of five neck muscles, subjective discomfort ratings, preference, and working postures were recorded. Results indicated that the middle height was proper for one monitor condition, but the low monitor height was recommended for more than two information sources.

비대칭무게중심을 지닌 물체 들기 작업시 허리부위 등근육 부하 및 피로 분석 (The Analysis of Low Back Loading and Muscle Fatigue while Lifting an Asymmetric Load)

  • 한승조;김선욱
    • 산업경영시스템학회지
    • /
    • 제35권2호
    • /
    • pp.30-36
    • /
    • 2012
  • This study is aimed to show that an asymmetric load in the frontal plane leads to an increase in low back loading and fatigue in comparison with a symmetric load when workers lift an external weight by investigating previous studies and verifying the phenomenon with an experiment. Ten male subjects are required to lift and hold an given external load at 70cm height during 50sec, then the EMG amplitude and median frequency on bilateral low back muscle groups (Longissimus, Iliocostalis, and Multifidus) are recorded and analyzed. Independent variables are two-level load weight (13kg, 20kg) and three-level LCG (Center, 6.5cm to the right, and 13cm to the right), and dependent variables are EMG amplitude average, difference, and Fatigue Index (FI). Results show that load weight increases significantly amplitude average and FI, but LCG does significantly amplitude difference and FI significantly (P-value < 0.05). Also the correlation coefficient between amplitude difference and FI is over 0.99. These implies that trunk loading should be explained by not EMG amplitude but muscle fatigue aspect since the association between an external load and amplitude is linear, but the relationship between an external load and median frequency as muscle fatigue index is almost exponential.

상원사목조문수동자좌상 복장 명주홑저고리의 보존처리 (The Preservation Treatment of Unlined Silk Jeogori Found at the Wooden Munsudongja Buddha Statue in the Sangwon Temple)

  • 권영숙;백영미
    • 한국의류산업학회지
    • /
    • 제8권6호
    • /
    • pp.634-638
    • /
    • 2006
  • The significance of this study is the demonstration of a new method of preservation procedure for national-treasure-class cultural-assets by examining the characteristics of the Jeogori relic, presumed to be that of King SeJo, and validating the preservation process. This Jergori as well as the wooden Munsu-donja Buddha statue from which they were found are designated as national treasure. The Jeogori relic is made of light silk and dimensions mark 77 cm in length, 67 cm in width, and 94 cm in sleeve length. It is a typical Jeogori worn in the Chosun Dynasty. Preservation procedure was in the following order: Removing dust and pollutants by vacuum, washing, removing creases, reinforcing the clothes, settling at paulownia backboard, and packing. Storage and exhibition of remains was executed with as minimal folding as possible, and microbiological damage prevention was performed by dyeing antibacterial treatment with eugenol onto supporting cloth. The relic, conservatively treated in accordance with the above procedure, is currently kept at the storage facility of the citadel Museum in the Woljeong Temple. It is displayed annually to the general public for approximately two weeks.

혼화재를 사용한 고강도 경량콘크리트에 관한 실험적 연구 (An Experimental Study on High Strength Lightweight Concrete Using Compound Materials)

  • 김종인;최영화;김정훈
    • 한국산업융합학회 논문집
    • /
    • 제6권2호
    • /
    • pp.115-122
    • /
    • 2003
  • This experimental study on high strength lightweight concrete using compound materials has been performed. In which, expanded clay was used as coarse aggregate, and silica fume and fly ash as admixtures varying by 0, 10% and 0, 5, 10, 15, 20% of cement amount respectively were added. Thus, the properties of fresh and hardened concrete have been investigated. The results of this study can be summarized as follows ; Each slump loss of mixtures replaced fly ash has been decreased by increasing replacement rate. The compressive strength have shown 465, 428 and $401kgf/cm^2$ at 30, 40 and 50% of W/B in 28days respectively, all of which have satisfied the criterion $270kgf/cm^2$ of high strength lightweight concrete. The unit volume weight of hardened concrete has been decreased by increasing replacement rate of silica fume and fly ash, values of which have satisfied the criterion $2000kgf/cm^3$of light weight concrete.

  • PDF

Development of a miniaturized FM transmitter with low power

  • 류정탁;김인경;김연보;김종필
    • 한국산업정보학회:학술대회논문집
    • /
    • 한국산업정보학회 2008년도 추계 공동 국제학술대회
    • /
    • pp.629-633
    • /
    • 2008
  • Recently, there has been great interest in the application of short-range wireless communication system. In this paper, the miniaturized FM transmitter with low power is developed, and laboratory tests have been carried out. The FM transmitter uses FM radio waves to send sound from any system (MP3, PMP, PDA, MP3 Phone et.) to any nearby radio or stereo system. The transmitter is designed with $2.6cm{\times}2.6cm{\times}2.6cm$ system size. The operating voltage is 3.7 V and used the built-in storage battery. The system can use continuously during 7 hour with once charging. The transmission frequency can select one of 88.1 MHz, 88.3 MHz, or 88.5 MHz in compliance with utility condition. The channel separation ability is 40 dB. The operating temperature is $-10{\sim}+85^{\circ}C$, which use in the industry environment. Consequently, this system sis used conveniently with short distance information transmitter system at the industry field.

  • PDF

용접 및 연마에서 발생되는 나노입자 특성 평가 : 수농도 및 입경분포 분석 (Characterization of Nanoparticles from Welding and Grinding Processes: Evaluation of Number Concentration and Size Distribution)

  • 김부욱;김현욱
    • 한국산업보건학회지
    • /
    • 제22권3호
    • /
    • pp.184-190
    • /
    • 2012
  • Objectives: This study aimed to characterize the nanoparticles produced by welding and grinding processes. Methods: The number concentrations of particles were mapped to determine the distribution of welding fumes in a workplace atmosphere using a hand-held condensation particle counter. An electrical low-pressure impactor was used for measuring the number concentration and particle size distribution. Results: High number concentrations were found around arc cutting and welding (grinding) processes. In the worker's breathing zone, the mean number concentration was 655,000 particles/cm3 and the count median diameter (CMD) was 84 nm with several multi peak distributions (~20, 70, 300 nm). However, at a distance of 3 m from the welding position, the number concentration decreased to 153,000 particles/cm3 with a 70 nm single peak size distribution. During a grinding process, peaks with high concentrations of nanoparticles were temporarily observed. The mean number concentration was 1,520,000 particles/cm3, and the CMD was 30 nm. Nanoparticles (<100 nm) made up 58% and 92% of the aerosols produced by welding and grinding processes, respectively.

SOC민간투자사업의 CM 운영체계 개발에 관한 연구 (A Study on Development for Construction Management System of Private Infrastructure Project)

  • 박영민;김수용;김대영;조훈희
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2004년도 제5회 정기학술발표대회 논문집
    • /
    • pp.404-407
    • /
    • 2004
  • 본 연구에서는 국내의 CM 조기정착을 유도하고 CM 활용에 대한 성공적인 모델을 제시하기 위하여, 향후 지속적으로 성장할 것으로 판단되는 SOC민간투자사업의 CM 운영체계 개발의 필요성 및 여건을 분석하고 개발 방향을 제시하였다. 본 연구에서 제안한 개발의 방향은 크게 (1)SOC민간투자사업 CM업무 표준 프로세스 가이드 개발, (2)SOC민간투자사업 타당성분석 수행 표준 개발, (3)SOC민간투자사업의 단계별 $\cdot$ 기능별 리스크 Check List의 세 가지 이며, 이와 같은 개발을 통하여 추후 CM 제도의 활성화를 위한 모범사례의 제공 뿐 아니라, 국내 건설산업의 효율성제고 등의 효과를 기대할 수 있을 것으로 판단된다.

  • PDF