• Title/Summary/Keyword: CLEARANCE

Search Result 2,376, Processing Time 0.036 seconds

Pharmacokinetic-Pharmacodynamic Modeling for the Relationship between Glucose-Lowering Effect and Plasma Concentration of Metformin in Volunteers

  • Lee, Shin-Hwa;Kwon, Kwang-il
    • Archives of Pharmacal Research
    • /
    • v.27 no.7
    • /
    • pp.806-810
    • /
    • 2004
  • Metformin is a biguanide antihyperglycemic agent often used for the treatment of non-insulin dependent diabetics (NIDDM). In this study, the pharmacokinetics and pharmacodynamics of metformin were investigated in Korean healthy volunteers during a fasting state for over 10 h. In order to evaluate the amount of glucose-lowering effect of metformin, the plasma concentrations of glucose were measured for a period of 10 h followed by the administration of metformin (oral 500 mg) or placebo. In addition, the concentration of metformin in blood samples was determined by HPLC assay for the drug. All volunteers were consumed with 12 g of white sugar 10 minutes after drug intake to maintain initial plasma glucose concentration. The time courses of the plasma concentration of metformin and the glucose-lowering effect were analyzed by nonlinear regression analysis. The estimated $C_{max}$, $T_{max}$, $CL_{t}$/F (apparent clearance), V/F(apparent volume of distribution), and half-life of metformin were 1.42$\{pm}$0.07 $\mu\textrm{g}$/mL, 2.59$\{pm}$0.18h, 66.12$\{pm}$4.6 L/h, 26.63 L, and 1.54 h respectively. Since a significant counterclock-wise hysteresis was found for the metformin concentration in the plasma-effect relationship, indirect response model was used to evaluate pharmacodynamic parameters for metformin. The mean concentration at half-maximum inhibition $IC_{50}$, $k_{in}$, $k_{out}$ were 2.26 $\mu\textrm{g}$/mL, 83.26 $H^{-1}$, and 0.68 $H^{-1}$, respectively. Therefore, the pharmacokinetic-pharmacodynamic model may be useful in the description for the relationship between plasma concentration of metformin and its glucose-lowering effect.

Effect of the Pocket Depth on the Hammering Behavior of an Air Bearing Stage (포켓의 깊이가 공기 베어링 스테이지의 햄머링 현상에 미치는 영향)

  • Lee, Chun Moo;Kim, Gyu Ha;Park, Sang Joon;Hwang, Gyu-Jin;Park, Sang-Shin
    • Tribology and Lubricants
    • /
    • v.37 no.4
    • /
    • pp.129-135
    • /
    • 2021
  • An air-bearing stage uses externally pressurized air as the lubricant between the stage and the rail. The supporting force generated by the supplied air makes the stage rise and move smoothly with extremely low friction. Mechanical contacts rarely happen, the bearing surfaces do not produce wear particles, and dust is not generated. It also has the advantage of having low energy loss and high precision. Because of its advantages, an air-bearing stage is used in several types of machines that require high precision. In this article, the effect of the pocket depth on the hammering phenomena of the air bearing is studied. An analysis program is developed to calculate the dynamic behavior of the stage by solving the Reynolds equation between the stage and the guideway and the equations of motion on the stage. The acceleration, constant movement, and deceleration are applied to the stage. The stage is modeled as a five-degree-of-freedom system. In the course of the dynamic behavior, the hammering phenomena occur under some special conditions. The deeper the pocket, the more unstable the behavior of the stage, and air hammering occurs when it exceeds a certain depth. In addition, the higher the supply pressure, the more unstable the behavior of the stage. However, hammering occurs even with a shallow pocket depth. Other conditions that affect the hammering phenomena are calculated and discussed.

Liquid chromatography-tandem mass spectrometric analysis of oleracone D and its application to pharmacokinetic study in mice

  • Lim, Dong Yu;Lee, Tae Yeon;Lee, Jaehyeok;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Analytical Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.193-201
    • /
    • 2021
  • We have demonstrated a sensitive analytical method of measuring oleracone D in mouse plasma using a liquid chromatography-tandem mass spectrometry (LC-MS/MS). Oleracone D and oleracone F (internal standard) in mouse plasma samples were processed using a liquid-liquid extraction method with methyl tertbutyl ether, resulting in high and reproducible extraction recovery (80.19-82.49 %). No interfering peaks around the peak elution time of oleracone D and oleracone F were observed. The standard calibration curves for oleracone D ranged from 0.5 to 100 ng/mL and were linear with r2 of 0.992. The inter- and intra-day accuracy and precision and the stability fell within the acceptance criteria. The pharmacokinetics of oleracone D following intravenous and oral administration of oleracone D at doses of 5 mg/kg and 30 mg/kg, respectively, were investigated. When oleracone D was intravenously injected, it had first-order elimination kinetics with high clearance and volume of distribution values. The absolute oral bioavailability of this compound was calculated as 0.95 %, with multi-exponential kinetics. The low aqueous solubility and a high oral dose of oleracone D may explain the different elimination kinetics of oleracone D between intravenous and oral administration. Collectively, this newly developed sensitive LC-MS/MS method of oleracone D could be successfully utilized for investigating the pharmacokinetic properties of this compound and could be used in future studies for the lead optimization and biopharmaceutic investigation of oleracone D.

A Study on Magnetic Field Reduction Design Technique around 345 kV Transmission Line with 2-wire Set Passive Loop (2선식 수동루프를 이용한 345[kV] 송전선 주변의 자계저감 설계기법 연구)

  • Kim, Eung Sik
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.5
    • /
    • pp.10-17
    • /
    • 2021
  • The controversy over the risk of the human body being affected by electromagnetic fields emitted from 60 Hz power lines continues without end. There are currently no new studies or research progress being made in this direction that is notable, and the number of civil complaints is gradually increasing. The problem is that each study produces different results, among which the effect of exposure to magnetic fields on childhood leukemia is a major one. In Korea, an electrician who was maintaining a 22.9 kV power line died of leukemia, which has recently been recognized as an occupational disease. Methods to reduce magnetic fields from power lines include shielding with wire loops, incorporating split phases and compaction techniques, installing underground power lines, converting to high-voltage direct current (HVDC), and increasing the ground clearance of transmission towers. Depending on whether a separate power supply is needed or not, there are two types of wire loops: passive loop and active loop. Magnetic field reduction is currently done through underground power lines; however, the disadvantage of this process is high construction costs. Installing passive loops, with relatively low construction costs, leads to lower magnetic field reduction rates than installing underground cables and a weakness to not solving the landscape problem. This methodological study aims at designing methods and reducing the effects of 2-wire set loops-the simplest and most practical. Since the method proposed in this study has been designed after analyzing the distribution of complex electromagnetic fields near the expected loop installation location, a practical design can be implemented without the need for any difficult optimization programming.

Nucleotide-binding oligomerization domain 1 is dispensable for host immune responses against pulmonary infection of Acinetobacter baumannii in mice

  • Kang, Min-Jung;Choi, Jin-A;Choi, Joo-Hee;Jang, Ah-Ra;Park, Ji-Yeon;Ahn, Jae-Hun;Lee, Tae-Sung;Kim, Dong-Yeon;Park, Jong-Hwan
    • Laboraroty Animal Research
    • /
    • v.34 no.4
    • /
    • pp.295-301
    • /
    • 2018
  • Nucleotide-binding domain 1 (Nod1) is a cytosolic receptor that is responsible for the recognition of a bacterial peptidoglycan motif containing meso-diaminophimelic acid. In this study, we sought to identify the role of Nod1 in host defense in vivo against pulmonary infection by multidrug resistant Acinetobacter baumannii. Wildtype (WT) and Nod1-deficient mice were intranasally infected with $3{\times}10^7CFU$ of A. baumannii and sacrificed at 1 and 3 days post-infection (dpi). Bacterial CFUs, cytokines production, histopathology, and mouse ${\beta}$-defensins (mBD) in the lungs of infected mice were evaluated. The production of cytokines in response to A. baumannii was also measured in WT and Nod1-deficient macrophages. The bacterial clearance in the lungs was not affected by Nod1 deficiency. Levels of IL-6, $TNF-{\alpha}$, and $IL-1{\beta}$ in the lung homogenates were comparable at days 1 and 3 between WT and Nod1-deficient mice, except the $TNF-{\alpha}$ level at day 3, which was higher in Nod1-deficient mice. There was no significant difference in lung pathology and expression of mBDs (mBD1, 2, 3, and 4) between WT and Nod1-deficient mice infected with A. baumannii. The production of IL-6, $TNF-{\alpha}$, and NO by macrophages in response to A. baumannii was also comparable in WT and Nod1-deficient mice. Our results indicated that Nod1 does not play an important role in host immune responses against A. baumannii infection.

Analysis of Integration Factor Effect in Dynamic-Structure-Fluid-Heat Coupled Time Transient Staggered Integration Scheme for Morton Effect Analysis (모튼이펙트 해석을 위한 동역학-구조-유체-열전달 시간과도응답 연성해석 시차적분법에서 시상수 효과 분석)

  • Suh, Junho;Jeung, Sung-Hwa
    • Tribology and Lubricants
    • /
    • v.35 no.1
    • /
    • pp.77-86
    • /
    • 2019
  • The present study focuses on the effect of staggered integration factor (SIF) on Morton effect simulation results. The Morton effect is a synchronous rotordynamic instability problem caused by the temperature differential across the journal in fluid film bearings. Convection and conduction of heat in the thin film displaces the hot spot, which is the hottest circumferential position in the thin film, from -20 to 40 degrees ahead of the high spot, where the minimum film clearance is experienced. The temperature differential across the journal causes a bending moment and the corresponding thermal bow in the rotating frame acts like a distributed synchronous excitation in the fixed frame. This thermal bow may cause increased vibrations and continued growth of the synchronous orbit into a limit cycle. The SIF is developed assuming that the response of the rotor-lubricant-bearing dynamic system is much quicker than that of the bearing-journal thermal system, and it is defined as the ratio between the simulation time of the thermal system and the rotor-spinning period. The use of the SIF is unavoidable for efficient computing. The value of the SIF is chosen empirically by the software users as a value between 100 and 400. However, the effect of the SIF on Morton effect simulation results has not been investigated. This research produces simulation results with different values of SIF.

Bolt Loosening Analysis under Transverse Vibration for Design of Reliable Pyrotechnic Separation Nut (신뢰성 있는 파이로테크닉 분리 너트 설계를 위한 진동 시 볼트 풀림 해석)

  • Choi, Jae Young;Woo, Jeongmin;Kang, Dahoon;Kim, Jeong Ho;Cho, Jin Yeon;Jang, Seung-gyo;Yang, Hee Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.12
    • /
    • pp.1004-1011
    • /
    • 2018
  • Recently, pyrotechnic separation nut has attracted a considerable attention because of its shock reduction effect among various pyrotechnic mechanical devices. However, its bolt loosening behavior under transverse vibration has not been studied sufficiently, since segmented nuts are utilized instead of conventional nut in pyrotechnic separation nut. With the background, bolt loosening analyses are carried out referring to Junker vibration test. The analysis procedure consists of two steps. The first step is the bolt fastening step, screwing the bolt by fastening torque. The second step is the bolt loosening step under transverse vibration. Through the procedure, bolt loosening behaviors are obtained, and the effect of clearance on loosening behavior is closely investigated for reliable design of pyrotechnic separation nut.

Daily Quest Design for Mobile Arcade Games -The Effect of Player's Tendency on Motivation- (모바일 아케이드 게임의 일일 퀘스트 디자인 연구 -플레이어의 성향과 동기를 중심으로-)

  • Ahn, Sihyeong;Lee, Sangwon
    • Journal of the HCI Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.83-91
    • /
    • 2019
  • These days, virtually every mobile game has a daily quest system. Daily quest is a great tool that can attract game players by providing daily rewards as the player conducts designated missions. However, conducting similar tasks repeatedly has a risk of becoming tedious duties, and maintaining an enjoyable daily quest is critical in enhancing the overall experience of a game. Based on the awareness on the need for academic research on daily quest systems, this study categorized the types of quests systems implemented in the current mobile games, observed how preferred type differs by player's propensity, and analyzed how motivation of a player can be improved using quest types. The results are (1) the staged rewards after each clearance of a task improve a player's motivation, (2) players with high autonomy should be given a freedom to choose their own quests, and (3) players who values their playing skills higher are motivated by providing a feedback on the completion of a task.

A study on speed-sensitive vehicle brake light system using LED (LED를 이용한 속도 감응형 차량용 브레이크등 시스템)

  • Kim, Tae-Jin;Kim, Hyung-Jun;Park, Seong-Jun;Park, In-Soo;Park, Sung-Won;Kim, Sung-Chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.809-810
    • /
    • 2016
  • In this study, Speed-sensitive vehicle brake using the LED, When the driver presses the brake pedal, range step while being turned in connection taillights brake of the vehicle, such as speed-sensitive vehicle brake using the LED, It is turned on according to the deceleration of the vehicle to be series of points are displayed. The rear vehicle can prevent collision about an abrupt stop of preceding vehicle by perceiving deceleration state of preceding vehicle easier and faster. Also, if the inter-vehicle distance by using an ultrasonic sensor is closer than a certain distance, the emergency light turns on to convey the situation to the driver of the rear vehicle with a buzzer.

  • PDF

Evaluation of Quality Management of Domestic Asbestos Survey and Monitoring Service Providers (국내 석면조사기관의 품질관리 수준에 대한 평가)

  • Kwon, Jiwoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.2
    • /
    • pp.217-225
    • /
    • 2019
  • Objectives: The aim of this study is to evaluate the quality management systems of domestic asbestos survey and monitoring service providers and the relationships with the number of licenses or designations and sales performances. Methods: Data on quality management systems were collected by assessors who were assigned by the Korea Occupational Safety and Health Agency(KOSHA) during a pilot evaluation program for designated asbestos survey and monitoring service providers in 2016 using evaluation criteria developed by KOSHA. Basic characteristics, evaluated scores, and sales performance were gathered and statistically analyzed. Results: The median and arithmetic mean of the total scores were 0.64 and 0.66. Evaluation fields that scored highly with the highest percentages were sales performance, installation and availability of equipment, compliance with the mandatory minimum number of airborne samples, laboratory independence, and results of proficiency analytical testing, in that order. Evaluation fields that received low marks with the highest percentages were the training of personnel, blank field samples, calibration of flow rates, preliminary check and visual inspection of the work area prior to the clearance test, and review and approval of final reports, in that order. Comparison of normalized scores between service providers registered for asbestos and other tasks and those designated for only asbestos showed significant differences in their evaluated scores. Sales performance did not show a positive correlation with evaluated scores. Conclusions: The quality management systems of domestic asbestos survey and monitoring service providers were poor. High scores were recorded mostly in evaluation fields related to regulatory requirements. Low scores were recorded mostly in evaluation fields related to documentation and recordkeeping. Considering the low influence of quality on sales performance, the government needs to evaluate the quality management of asbestos survey and monitoring service providers and provide the results to public in order to address their low levels of quality management.