• Title/Summary/Keyword: CLEARANCE

Search Result 2,376, Processing Time 0.031 seconds

Variable Passive Compliance Device for Robotic Assembly (조립 로봇용 가변 수동 강성 장치의 설계)

  • Kim, Hwi Su;Park, Dong Il;Park, Chan Hun;Kim, Byung In;Do, Hyun Min;Choi, Tae Yong;Kim, Doo Hyung;Kyung, Jin Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.6
    • /
    • pp.517-521
    • /
    • 2016
  • General industrial robots are difficult to use for precision assembly because they are operated based on position control. Their position accuracy is also usually higher than the assembly clearance (several tens of ${\mu}m$). In previous researches, force control was suggested as a robotic assembly solution. However, this method is difficult to apply in reality because of speed and cost problems. The RCC provides high speed, but applications are limited because the compliance is fixed, and it cannot detect an assembly condition during a task. A variable passive compliance device (VPCD) was developed herein. The VPCD can detect the assembly condition during tasks. This device can provide proper compliance for successful assembly tasks. The pneumatic system and the Stewart platform with an LVDT sensor were applied for measuring the displacement and variable compliance, respectively. The concept design and analysis were conducted to prove the effectiveness of the developed VPCD.

Evaluation of Post-Operative Residual Tumors Using $^{67}Ga$ Scintigram 1. Is the Blood Gallium Redistributed into the Surgical Wound? ($^{67}Ga$ 신티그램을 이용한 술후잔여종양의 평가 1. 혈중 $^{67}Ga$은 수술창상에 재분포하는가?)

  • Moon, Tae-Yong;Sol, Chang-Hyo;Kim, Yong-Ki;Wang, Soo-Geun;Han, Kook-Sang;Choi, Chang-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.355-359
    • /
    • 1992
  • The $^{67}Ga$ has somewhat long physical and biological half livies with 78 hours and 600 hours respectively, so we can get $^{67}Ga-scan$ images for 3 or more days after once injection of $^{67}Ga$. Furthermore $^{67}Ga$ scan would be useful to search some residual tumors after surgical removal of the tumors trapped with $^{67}Ga$. However $^{67}Ga$ bound with plasma proteins would be delayed in plasma clearance as approximately 10% of the dose remains in the plasma at 24 hours. If the remained $^{67}Ga$ in the plasma is redistributed into the surgical wound, we wouldn't evaluate the degree of the tumor remained after surgery. So the authors examined the amounts of the remained blood $^{67}Ga$ and the redistribution of the blood $^{67}Ga$ into the artificial wound with S or more centimeters in the diameter at the neck and chest of the rabbits. The results were as follows; 1) The $^{67}Ga$ remained in the plasma were 12%, 5.7%, 4.2% at 24, 48 and 72 hours after $^{67}Ga$ injection respectively. 2) The blood $^{67}Ga$ were redistributed into the artificial wound with 5.9% at 48 hours and 6.9% at 72 hours after $^{67}Ga$ injection.

  • PDF

Antitumor and Immunostimulating Activities of Acanthopanax sessiliflorus Fruits

  • Lee, Sang-Hyun;Lee, Yeon-Sil;Jung, Sang-Hoon;Ji, Jun;Shin, Kuk-Hyun;Kim, Bak-Kwang;Kang, Sam-Sik
    • Natural Product Sciences
    • /
    • v.9 no.2
    • /
    • pp.112-116
    • /
    • 2003
  • The antitumor and immunostimulating activities of Acanthopanax sessiliflorus fruits were investigated. Polysaccharide isolated from this plant, when administered consecutively for 9 days at 50 and 100 mg/kg i.p. in mice, caused a significant increase in the life span and a significant decrease in the tumor weight and volume in mice inoculated with Sarcoma-180 tumor cells. Polysaccharide was also demonstrated to exhibit phagocytosis-enhancing activity as measured by the carbon clearance in mice. Polysaccharide, when administered i.p. at 50 and 100 mg/kg/day for 3 consecutive days, exhibited a significant RCtr/RCc [the rate of regression coefficient of the animals teated (RCtr) to that of the control (RCc)], being 1.44 (PI = 1), 1.52 (PI = 2) which was approximately the same with that of enhancement of phagocytosis, its potency as expressed by the regression coefficient ratio of zymosan (RCtr/RCc = 1.55, PI = 2), a typical phagocytosis enhancer. Polysaccharide also caused a significant increase in the acid phosphatase activity representing lysosomal enzymes in macrophages at 1-100 ig/ml in vitro in compliance with in vivo results. These results suggest that the antitumor activity of polysaccharide might be related to the immunostimulating function.

Kinematic Analysis of Hurdling of Elite 110-m Hurdlers (엘리트 110m 허들선수의 세 번째 허들 넘기 동작에 대한 자세 분석)

  • Lee, Jin-Taek
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.761-770
    • /
    • 2009
  • The purpose of this study was to observe the kinematic patterns of hurdling by domestic hurdlers and elite hurdlers from other countries in particular, we studied the hurdling motion and joint angles at the third hurdle in 110-m hurdle races. There were slight differences in the following variables at takeoff and landing: angle of the center of gravity(elite hurdler, $34.14^{\circ}$ domestic hurdler, $24.89^{\circ}$), angle variables the body angle(elite hurdler, $4.27^{\circ}$ domestic hurdler, $6.37^{\circ}$), the angle of trunk inclination(elite hurdler, $3.18^{\circ}$ domestic hurdler, $11.58^{\circ}$), and the hip angle(elite hurdler, $40.1^{\circ}$ domestic hurdler, $43.2^{\circ}$).

Electrorheological Properties of ER Fluid under High Shear Flow (고속 전단유동에서 ER유체의 전기유변 특성)

  • Kim Y. C.;Kim K. W.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.229-234
    • /
    • 2003
  • As electrorheological fluid(ER fluid) has a characteristic that apparent viscosity varies when electric field applied, so rheological characteristic(yield stress & viscosity) changes in proportion to the electric field applied and the response time is very short within a few miliseconds . In case of using ER fluid for journal bearing as lubricant, it is estimated that it's possible to realize very effective journal bearing system that is not complicate and has a very quick response time. It is necessary to examine the influence of rheological characteristic that varies with electric field applied on bearing characteristic to apply ER fluid to journal bearing, however there are few studies for about that. As for the journal bearing, it comes under high shear flow mode that has shear rate range of $10^3\~10^4s^{-1}$ because rotational speed is very high and clearance is small. But most of the studies for about ER fluid issued until now is about the range of $10\~10^2s^{-1}$. So, there are a lot of difficulties to understand the characteristic offish shear flow mode and furthermore it is restricted to make an experiment for about the characteristic of ER fluid because of the limitation of experimental equipment. The equipment was prepared to make an experiment lot high shear flow mode that has the range of $10^3\~10^4s^{-1}$ using ER fluid that is composed of silicon oil with dispersed particle of starch. Using the above system, the fluid characteristic of ER fluid was studied.

  • PDF

Test Rig Development for Identification of Rotordynamic Force Coefficients of Squeeze Film Dampers in Automotive Turbocharger Bearing Systems (자동차 터보차저 베어링 시스템에 적용되는 스퀴즈 필름 댐퍼의 동적계수 측정을 위한 실험장치 개발)

  • Hwang, Jisu;Ryu, Keun;Jeung, Sung-Hwa
    • Tribology and Lubricants
    • /
    • v.34 no.1
    • /
    • pp.33-41
    • /
    • 2018
  • This paper describes a new test rig for identification of rotordynamic force coefficients of squeeze film dampers (SFDs) in automotive turbochargers (TCs). Prior studies have mainly concentrated on relatively large-sized SFDs used in aircraft engines, turbocompressors, and turbopumps. The main objective of the current study is to propose a test rig for identification of dynamic force coefficients of small-sized SFDs (a journal diameter of ~11 mm). The current test rig consists of a journal, a SFD cartridge, four support rods, an upper structure, a data acquisition (DAQ) system, and an oil circulation unit. The annular gaps between the journal outer surface and SFD cartridge inner surface create SFD film lands. The damper has two parallel film lands separated by a central groove, having an axial length and depth of 3 mm. Each film land has a length of 4 mm with a $40{\mu}m$ radial clearance. The static load and dynamic impact tests identify the structural characteristics (i.e., stiffness and natural frequency) of the journal and assembled test rig. The measurements show good agreement with predictions. The SFD performance data from this test rig will be used to develop innovative TC rotor systems with improved NVH and reliability characteristics incorporating advanced SFD technology.

Finite Element Bending Analysis of Oval Tubes Using Rotary Draw Bender for Hydroforming Applications (로터리 드로우 벤더를 이용한 타원형 튜브의 유한요소 벤딩 해석)

  • Lee Ho-Kuk;Tyne Chester J. Van
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.71-74
    • /
    • 2005
  • In manufacturing automotive parts, such as engine cradles, frame rails, subframes, cross-members, and other parts from circular tubes, pre-bending and pre-forming operations are often required prior to the subsequent tubular hydroforming process. During some pre-forming operations, the cross section of a bent circular tube is crushed into an oval-like shape to ensure proper geometry and sufficient clearance in the hydroforming dies. For such applications, the use of oval Instead of circular tubes could be an effective means of eliminating the pre-forming step. The oval tube could also be produced with less thinning and with less strain on the outside of the bend when controlled by a booster system without the use of mandrel. Hence, the understanding of the issues that occur in the bending of oval tubes is worthy of Investigation. This paper presents parametric studies on the bending of oval tubes without a mandrel. The finite element modeling technique is used to examine the deformation characteristics for both circular and oval tubes. In the simulations, the bending process parameters of bend radius, aspect ratio of the tube ovalness, and tube wall thickness are varied. Observations are made to obtain a hoop-buckle limit diagram in terms of a non-dimensional shape degradation factor. Suggestions based upon developed criteria are made on the acceptability of bend tubes suitable for hydroforming applications without the need ofa pre-forming step or the used of a mandrel.

  • PDF

Indocyanine Green Excretion Test in Korean Black Goats (한국 흑염소에 있어서 Indocyanine Green 배설시험)

  • Lee Sung-Yub;Lee Chang-Woo
    • Journal of Veterinary Clinics
    • /
    • v.4 no.2
    • /
    • pp.473-481
    • /
    • 1987
  • This experiment was performed in order to establish a proper method to determine the half life of indocyanine green(ICG T$\frac{1}{2}$) and its fractional clearance rate(KICG) and investigate the applicability of indocyanine green ( ICG ) excretion test in hepatotoxicity experiment in Korean black goats. The results were as follows : 1. Maximum absorbance of ICG in plasma was at 810 nm in this experiment. 2. The coefficient of correlation between the results obtained by standard method and potassium cyanide method was 0.99 and the regression equation between two methods was y=0.9996 x+0.0065. 3. As the disappearance curve of ICG plotted in semi-log graph revealed linear pattern at least for 6 minutes after injection, the postinjection blood samples were decided to collect at 2 and 6 minutes after ICG injection. 4. ICG T$\frac{1}{2}$ and KICG values were not affected by dose level of ICG. 5. When 0.25 mg of ICG per kg body weight was administered the normal data of ICG T$\frac{1}{2}$ and KICG in Korean black goa were 1.468${\pm}$0.197 minutes(mean${\pm}$SD) and 0.482${\pm}$0.076/minutes respectively. 6. After administration of carbon tetracholride. the ICG T$\frac{1}{2}$ started to increase acutely from day 1, revealed the peak at day 3, and then returned almostly but not completely to preinjection level at day 14. The ICG T$\frac{1}{2}$ value was suggested to be a sensitive indicator of hepatic injury in Korean black goats.

  • PDF

Effects of Caffeine and Pentoxifylline on Pharmacokinetics of Propentofylline

  • Kwon, Oh-Seung;Kim, Min-Hee;Ryu, Jae-Chun;Chung, Youn-Bok
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1998.11a
    • /
    • pp.122-122
    • /
    • 1998
  • Propentofylline (PPF), a xanthine derivative, has been reported to be effective for the treatment of both vascular dementia and Alzheimer's disease. The elimination half-life of PPF was ranged from 15 to 45 min in rabbit and human, and PPF was rapidly disappeared from the blood. The objective of this experiment is to investigate whether xanthine analogues have effects on the profile of plasma concentration and metabolism of PPF. Caffeine (50 mg/kg, ip) was treated to Sprague-Dawley rats for consecutive 7 days and PPF was intravenously administered to rats 2 hr after the last dose of caffeine. In the other group, PPF was intravenously administered to rats 1 hr after a single dose of pentoxifylline (50 mg/kg, iv). Control group was treated with saline vehicle for the same period as in treatment groups. Blood was withdrawn at specific time intervals. PPF and one of its metabolite (POH) in plasma were determined by gas chromatography/nitrogen phosphorus detector. Plasma concentrations and pharmacokinetic parameters were compared between groups. The area under the curve (AUC) of PPF in rats treated sub chronically with caffeine was significantly decreased compared to control rats. Caffeine treatment results in a significant increase of total body clearance. The AUC of POH was significantly decreased in the caffeine-treated group. A single dose of pentoxifylline has no effect on the phramacokinetics of PPF. Reduction of the AUCs of PPF and POH both suggests that caffeine may increase the excretion of PPF with no affecting the metabolism of PPF to POH.

  • PDF

Pharmacokinetics and Tissue Distribution of a New Fluoroquinolone Containing C7-Bicyclic Structure in Rats (C7-이환체 구조를 갖는 새로운 플루오로퀴놀론계 항생물질의 흰쥐 체내동태와 조직분포)

  • 조재열;한승희;김병오;남권호;손호정;이재욱;유영효;박명환
    • Biomolecules & Therapeutics
    • /
    • v.5 no.4
    • /
    • pp.419-425
    • /
    • 1997
  • The pharmacokinetics of DWP20364 (1-cyclopropyl -5-amino-6,8-difluoro-7-(2,7-diazabiclo [3,3,0] oct-4-ene-7-yl)-1,4-dihydro-4-oxoquinoline-3-carboxylic acid), a novel fluoroquinolone containing C7-bicyc-talc structure, were compared with those of ciprofloxacin (CPFX) after single intravenous (i.v.) and oral (p.o.) administration to rats using microbiological assay (bioassay). After i.v. administration to rats, the plasma concentrations of the two drugs declined biexponentially. The terminal half-lives (t$_{1}$2$\beta$/) of DWP20364 were 110$\pm$ 13.2 min and 117$\pm$3.09 min after i.v. and p.o. administration, respectively, and they were significantly higher than those of CPFX (45.5$\pm$9.52 min and 48.3$\pm$ 12.1 min, respectively). Similar results were also obtained from plasma concentrations and area under the plasma concentration-time curves. The total body clearance of DWP20364, 7.82$\pm$0.37 ml/min/kg was significantly slower than that of CPFX, 27.3 $\pm$ 11.1 m1/ min/kg. Above data suggested that the antimicrobial activity of DWP20364 could be longer than that of CPFX. The urinary recovery after i.v. and p.o. administration of DWP20364 was significantly lower than those of CPFX suggesting that the effect of DWP20364 on urinary tract infection could be lower than that of CPFX. The serum protein binding values of DWP20364 at 2$\mu$g/ml were apparently 91.5~93.1% in rats and human. DWP20364 was distributed by the order of liver, lung, kidney, sf)leon, heart, muscle and brain collected at 30 min after orally administered.

  • PDF