• Title/Summary/Keyword: CLEARANCE

Search Result 2,376, Processing Time 0.037 seconds

A Sutdy on the UWB Intenna with Band-Stop Function for Mobile Handsets (대역 저지 특성을 갖는 휴대 단말기용 초소형 UWB Intenna에 관한 연구)

  • Lim, Yo-Han;Yoon, Young-Joong;Ho, Yo-Chuol;Jung, Byung-Woon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1445-1454
    • /
    • 2008
  • In this paper, small UWB antenna with band-stop function for mobile handsets is proposed. A gap between radiator and under and side ground is adjusted for small size and broadband. A radiator is folded to the back side of PCB for miniaturization and tapered feeding structure is used to enhance matching characteristic. A antenna clearance has a size of $14{\times}14\;mm^2$ and a size of radiator is $10{\times}7\;mm^2$. It covers all UWB band from 3.15 GHz to 4.75 GHz and from 7.2 GHz to 10.2 GHz for VSWR<2 and has band stop characteristic at 5.8 GHz. A maximum gain is measured as 5.85 GHz. In case conventional handset case is considered, it also covers all UWB and a maximum gain is measured from -2 dBi to -2 dBi.

Alternate metal framework designs for the metal ceramic prosthesis to enhance the esthetics

  • Vernekar, Naina Vilas;Jagadish, Prithviraj Kallahalla;Diwakar, Dr Srinivasan;Nadgir, Ramesh;Krishnarao, Manjunatha Revankar
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.3
    • /
    • pp.113-118
    • /
    • 2011
  • PURPOSE. The objective of the present study was to evaluate the effect of five different metal framework designs on the fracture resistance of the metal-ceramic restorations. MATERIALS AND METHODS. For the purpose of this study, the central incisor tooth was prepared, and the metal analogue of it and a master die were fabricated. The counter die with the 0.5 mm clearance was used for fabricating the wax patterns for the metal copings. The metal copings with five different metal framework designs were designed from Group 1 to 5. Group 1 with the metal collar, Group 2, 3, 4 and 5 with 0 mm, 0.5 mm, 1 mm and 1.5 mm cervical metal reduction respectively were fabricated. Total of fifty metal ceramic crown samples were fabricated. The fracture resistance was evaluated with the Universal Testing Machine (Instron model No 1011, UK). The basic data was subjected to statistical analysis by ANOVA and Student's t-test. RESULTS. Results revealed that the fracture resistance ranged from 651.2 to 993.6 N/$m^2$. Group 1 showed the maximum and Group 5 showed the least value. CONCLUSION. The maximum load required to fracture the test specimens even in the groups without the metal collar was found to be exceeding the occlusal forces. Therefore, the metal frameworks with 0.5 mm and 1 mm short of the finish line are recommended for anterior metal ceramic restoration having adequate fracture resistance.

THE COMPARATIVE STUDY OF THERMAL INDUCTIVE EFFECT BETWEEN INTERNAL CONNECTION AND EXTERNAL CONNECTION IMPLANT IN ABUTMENT PREPARATION (구강내에서 임플랜트 지대주 형성 시 내부연결방식과 외부연결방식간의 열전달 효과 비교)

  • Huh, Jung-Bo;Ko, Sok-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.60-70
    • /
    • 2007
  • Statement of problem: The cement-type abutment would be needed for the reduction of its body in order to correct the axis and to assure occlusal clearance. In the case of intraoral preparation, there is a potential risk that generated heat could be transmitted into the bone-implant interface, where it can cause deterioration of tissues around the implant and failed osseointegration. Purpose: The purpose of this study was to assess the difference of the heat transmitting effect on external and internal connection implant types under various conditions. Material and method: For evaluating the effects of alternating temperature, the thermocoupling wires were attached on 3 areas of the implant fixture surface corresponding to the cervical, middle, and apex. The abutments were removed 1mm in depth horizontally with diamond burs and were polished for 30 seconds at low speed with silicone points using pressure as applied in routine clinical practice. Obtained data were analyzed using Mann-Whitney rank-sum test and Wilcoxon / Kruskal-Wallis Tests. Result: Increased temperature on bone-implant interface was evident without air-water spray coolant both at high speed reduction and low speed polishing (p<.05). But, the difference between connection types was not shown. Conclusion: The reduction procedure of abutment without using proper coolant leads to serious damage of oral tissues around the implant irrespective of external and internal connection type.

Single Nucleotide Polymorphism of Interferon Lambda-4 Gene is not Associated with Treatment Response to Pegylated Interferon in Thai Patients with Chronic Hepatitis B

  • Limothai, Umaporn;Wasitthankasem, Rujipat;Poovorawan, Yong;Tangkijvanich, Pisit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.13
    • /
    • pp.5515-5519
    • /
    • 2015
  • The single nucleotide polymorphism (SNP) ss469415590 in the interferon lambda-4 (IFNL4) gene has recently been reported to have an association with treatment response in chronic hepatitis C. However, any importance of the SNP in association with response to pegylated interferon (PEG-IFN) therapy in patients with chronic hepatitis B (CHB) is unclear. We retrospectively analyzed data for Thai patients with CHB treated with PEG-IFN for 48 weeks. Virological response (VR) for HBeAg-positive CHB was defined as HBeAg seroconversion plus HBV DNA level <2,000 IU/mL at 24 weeks post-treatment. VR for HBeAg-negative CHB was defined as an HBV DNA level <2,000 IU/mL at 48 weeks. The SNP was identified by real time PCR using the TaqMan genotyping assay with MGB probes. A total 254 patients (107 HBeAg-positive and 147 HBeAg-negative) were enrolled in the study. The distribution of TT/TT, ${\Delta}G/TT$ and ${\Delta}G/{\Delta}G$ genotypes was 221 (87.0%), 32 (12.6%) and 1 (0.4%), respectively. Patients with non-TT/TT genotypes had significantly higher baseline HBV DNA levels than patients with the TT/TT genotype. In HBeAg-positive CHB, 41.2% of patients with TT/TT genotype versus 50.0% with non-TT/TT genotype achieved VR (P=0.593). In HBeAg-negative CHB, the corresponding figures were 40.3% and 43.5%, respectively (P=0.777). There was no significant correlation between the SNP genotypes and HBsAg clearance in both groups of patients. In summary, ss469415590 genotypes were not associated with response to PEG-IFN in Thai patients with HBeAg-positive and HBeAg-negative CHB.

A Study of Liver Scan using $^{113m}In$ Colloid ($^{113m}In$ 교질(膠質)에 의(依)한 간주사(肝走査)에 관(關)한 연구(硏究))

  • Koh, Chang-Soon;Rhee, Chong-Heon;Chang, Ko-Chang;Hong, Chang-Gi D.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.1
    • /
    • pp.83-99
    • /
    • 1969
  • There have been reported numberous cases of liver scanning in use of $^{198}Au$ colloid by many investigators, however, one in use of $^{113m}In$ colloid has not been reported as yet in this country. The dose of $^{113m}In$ for high diagnostic value in examination of each organ was determined and the dignostic interpretability of liver scanning with the use of $^{113m}In$ was carefully evaluated in comparison with the results of the liver scanning by the conventionally applied radioisotopes. The comparative study of both figures of liver scannings with the use of $^{113m}In$ colloid and $^{198}Au$ colloid delivered following results: 1. The liver uptake rate and clearance into peripheral blood were accentuated more in case of $^{113m}In$ colloid than in case of $^{198}Au$ colloid. 2. The interpretability of space occupying lesion in liver scanning with $^{113m}In$ was also superior to one with $^{198}Au$. 3. The figure of liver scanning with $^{113m}In$ colloid corresponds not always to the figure with $^{198}Au$. This difference can be explained by differences of phagocytic ability of reticuloendotherial system within liver. 4. In the liver scanning with $^{113m}In$ colloid, the spleen is also visualized even in normal examinee. 5. In the cases of disturbed liver function, uptake is more decreased in use of $^{113m}In$ colloid than in $^{198}Au$, in the spleen, however, the way is contrary. 6. With use of $^{113m}In$ colloid, the time required for scanning could be shortened in comparison with $^{198}Au$. 7. The filtration of $^{113m}In$ colloid for scanning prior to human administration gives an expectation for better scanning figure.

  • PDF

Incidence of Cisplatin-Induced Nephrotoxicity and Associated Factors among Cancer Patients in Indonesia

  • Prasaja, Yenny;Sutandyo, Noorwati;Andrajati, Retnosari
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1117-1122
    • /
    • 2015
  • Background: Cisplatin is still used as a first-line medication for solid tumors. Nephrotoxicity is a serious side effect that can decrease renal function and restrict applicable doses. This research aimed to obtain the profile of cisplatin-induced nephrotoxicity and its associated factors in adult cancer patients at Dharmais National Cancer Hospital (DNCH). Materials and Methods: The design was cross-sectional with data obtained from patient medical records. We retrospectively reviewed adult cancer patients treated with cisplatin ${\geq}60mg/m^2$ for at least four consecutive chemotherapy cycles from August 2011 to November 2013. The nephrotoxicity criterion was renal function decline characterized by creatinine clearance <60 ml/min using the Cockroft-Gault (CG) equation. Results: Eighty-eight subjects received at least four chemotherapy cycles of cisplatin. The prevalence of cisplatin nephrotoxicity was 34.1%. Symptoms could be observed after the first cycle of chemotherapy, and the degree of renal impairment was higher with increased numbers of cycles (r=-0.946, $r^2=89.5%$). Factors that affected the decline of renal function were patient age (p=0.008, OR=3.433, 95%CI= 1.363-8.645) and hypertension (p=0.026, OR=2.931, 95%CI=1.120-7.670). Conclusions: Cisplatin nephrotoxicity occurred in more than one-third of patients after the fourth cycle of chemotherapy and worsened after each cycle despite preventive strategies such as hydration. The decline of renal function induced by cisplatin ${\geq}60mg/m^2$ was affected by age and hypertension.

Tumor Necrosis Factor Alpha -308 G/A Single Nucleotide Polymorphism and Susceptibility to Hepatocellular Carcinoma Via Hepatitis B Infection

  • Azar, Saleh Shahbazi;Mansoori, Maryam;Attar, Marzieh;Shahbazi, Majid
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3381-3384
    • /
    • 2016
  • Background: Hepatitis B virus (HBV) is a key factor for hepatocellular carcinoma (HCC). About 350 million people are affected by chronic infection which is related to the rapid development of liver diseases as well as hepatitis, cirrhosis and hepatocellular carcinoma. Expression of tumor necrosis factor alpha (TNF-${\alpha}$) in the liver demonstrates a major genetic polymorphism which is involved in resistance or susceptibility to chronic HBV infection. Materials and Methods: In this study, two populations were studied by the sequence specific primer-polymerase chain reaction (SSP-PCR) method: HBV cases (n=409), who were HBS-Ag+, and healthy controls (n=483). Results: The results shown that the frequency of TNF-${\alpha}$ -308 G/G genotype in healthy controls (47.2%) was significantly higher than in HBV infected patients (28%) (CI = 1.29-2.61, OR = 1.83, P = 0.0004). Also TNF-${\alpha}$ -308 A/A and A/G genotype frequencies in the healthy controls were 4.6% and 48.2% and in patient group were 19.5% and 52.5% (CI = 2.23-7.12, p: 0.0001, OR: 3.94) respectively. Conclusions: We found that among Iranian people TNF-${\alpha}$ -308A allele not only has the highest genotype frequency but also it has the highest frequency in the world population. In addition, TNF-${\alpha}$-308 G/G polymorphism was associated with HBV resistance, whereas TNF-${\alpha}$-308A (A/A or A/G) polymorphism appeared to associated with chronic HBV infection. These data suggested that among the Iranian population, the -308 G/G polymorphism of TNF-${\alpha}$ gene promoter region has the potential to influence the susceptibility to HBV infection and it may be responsible for viral antigen clearance.

Studies on the Processing of Powdered Katsuobushi and Its Flavor Constituents 4. Extractive Conditions and Sensory Evaluation of Taste Compounds of Powdered Katsuobushi (분말가쓰오부시의 제조 및 풍미성분에 관한 연구 4. 분말가쓰오부시 정미성분의 추출조건 및 관능검사)

  • OH Kwang-Soo;LEE Eung-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.22 no.5
    • /
    • pp.228-232
    • /
    • 1989
  • Katsuobushi has widely been used from olden times to prepare soup stock. This study was carried out to prepare stock of powdered Katsuobushi, and to examine the extractive conditions and the contribution of principal taste compounds to its characteristic taste. The extractive condition of powdered Katsuobushi in preparing stock was the most appropriate at $100^{\circ}C$ for 1 minute boiling water-steeping method in flavor, clearance of stock. From the chemical analysis and omission test, the principal taste-active components in $4\%$ solution powdered Katsuobushi under this extractive condition were nucleotides 93.6mg/100ml, free amino acids and imidazole dipeptides 41.3mg/100ml, and non-volatile organic acids 39.3mg/100l1 in order. IMP, inosine, AMP, histidine, anserine, taurine, carnosine and lactic acid were predominant among the detected compounds.

  • PDF

Effects of Croton Tiglii Semen Water Extracts on the Renal Function and Endocrine Function in Rats (파두(巴豆) 추출액(抽出液)의 백서(白鼠) 신장기능(腎臟機能) 및 혈장(血漿) Hormone에 미치는 영향(影響))

  • Kim, Yu-Kam;Yu, Yun-Cho;Ryu, Do-Gon;Yum, Ki-Bok;Lee, Ho-Sub
    • The Journal of Korean Medicine
    • /
    • v.18 no.2
    • /
    • pp.214-222
    • /
    • 1997
  • The aim of this experiments was to investigate the effect of Croton. Tiglii. semen water extract on the renal function, plasma renin activity, plasma levels of atrial natriuretiu peptide and aldosterone in rats. The results of this study were as follows: 1. Water balance was not changed significantly after the administration of Croton Tiglii semen water extract. 2. Urine volume decreased significantly after the administration of Croton Tiglii semen water extract $80{\mu}l/200g$. 3. Urinary excretion of sodium increased significantly after the administration of Croton Tiglii semen water extract $40{\mu}l/200g$, but decreased significantly after the administration of Croton Tiglii semen water extract $80{\mu}l/200g$. 4. Urinary excretion of potassium decreased significantly after the administration of Croton Tiglii semen water extract $80{\mu}l/200g$. 5. Urinary excretion of chloride was not changed significantly after the administration of Croton Tiglii semen water extract. 6. Free water clearance was not changed significantly after the administration of Croton Tiglii semen water extract. 7. Urinary excretion of creatinine increased significantly after the administration of Croton Tiglii semen $40{\mu}l/200g$. 8. Plasma renin activity was not changed significantly after administration of Croton Tiglii semen water extract. 9. Plasma levels of atrial natriuretic peptide increased significantly after administration of Croton Tiglii semen water extract. 10. Plasma levels of aldosterone increased significantly after administration of Croton Tiglii semen $40{\mu}l/200g$.

  • PDF

Evaluation of Renal Function Using the Level of Neutrophil Gelatinase-Associated Lipocalin is Not Predictive of Nephrotoxicity Associated with Cisplatin-Based Chemotherapy

  • Kos, F. Tugba;Sendur, Mehmet Ali Nahit;Aksoy, Sercan;Celik, Huseyin Tugrul;Sezer, Sevilay;Civelek, Burak;Yaman, Sebnem;Zengin, Nurullah
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.1111-1114
    • /
    • 2013
  • Background: For early detection of renal damage during the usage of cisplatin based chemotherapy, changes in renal function should be monitored carefully. In recent years, neutrophil gelatinase-associated lipocalin, a small polypeptide molecule, has shown promise as a marker of acute renal failure. The aim of this present study was to assess possible risk prediction of cisplatin-induced nephrotoxicity using serum NGAL. Materials and Methods: A total of 34 consecutive patients with documented serum creatinine at least 24 hours before every cycle of cisplatin-based chemotherapy were included in the study. Demographic and medical data including age, performance status, tumor characteristics and comorbid diseases were collected from medical charts. Renal function was evaluated at least 48 hours before the treatment and at the end of the treatment based on the Modification of Diet in Renal Disease (MDRD) formula. Before and after cisplatin infusion serum NGAL levels were measured for the first and 3rd cycles of chemotherapy. Results: The median age of the study population was 54 (32-70) years. Fifteen patients (41.1%) were treated on an adjuvant basis, whereas 19 patients (58.9%) were treated for metastatic disease. There was no correlation of serum NGAL levels with serum creatinine (r=0.20, p=0.26) and MDRD (r=-0.12, p=0.50) and creatinine clearance-Cockcroft-Gault (r=-0.22, p=0.22) after cisplatin infusion at the end of the 3rd cycle of chemotherapy. Conclusions: In our study, serum NGAL levels were not correlated with the cisplatin induced nephrotoxicity. Further prospective studies are needed to conclude that serum NGAL level is not a good surrogate marker to predict early cisplatin induced nephrotoxicity.