• Title/Summary/Keyword: CFs

Search Result 342, Processing Time 0.019 seconds

Minireview for Chronic Fatigue Syndrome and its Medical Attention recently

  • Son, Chang-Gue
    • The Journal of Korean Medicine
    • /
    • v.40 no.4
    • /
    • pp.84-90
    • /
    • 2019
  • Objectives: Chronic fatigue syndrome (CFS) is a debilitating illness impairing seriously quality of life, while CFS would be an optimized target disorder of Korean medicine. This study aims to present the recent information especially in aspect of medical policy and new diagnosis criteria for CFS. Methods: The literature survey was conducted using the terms of "chronic fatigue syndrome", "myalgic encephalomyelitis" and "fibromyalgia" in PubMed database and Google database in its entirety from January 2011 to February 2019. The in-depth review was made focusing on the changes in policy and medical perspective for CFS. Results: Recently large medical attentions and researches for CFS have been existed worldwide. By supporting of USA government, IOM made a report which leaded to a turning point in clinical practices and research in 2015. This report recommended a new name of CFS to systemic exertion intolerance disease (SEID), and new diagnostic criteria focusing on post-exertional malaise, unrefreshing sleep, cognitive impairment and orthostatic intolerance. The medical perspective also was changed into "a serious, chronic, complex, systemic disease" from a psychological-like disorder, and then UAS and EU governments sharply increased the research grants. Conclusions: This study provided practitioners in Korean medicine (KM) a core information about the recent changes in CFS-related perspectives. This review would be helpful for KM-derived researches or therapeutics development for CFS.

Evaluation of Effect on CFS Location (CFS 입지에 따른 경제적 효과 평가)

  • Song, Yong-Seok;Nam, Ki-Chan;Kwak, Kyu-Seok
    • Journal of Navigation and Port Research
    • /
    • v.28 no.1
    • /
    • pp.69-74
    • /
    • 2004
  • Container Freight Station(CFS), which would be located inside terminal or outside, plays the role of consolidating less than container load(LCL) cargo gathered from multi shippers and deconsolidating full container load cargo into individual consignment. When CFS is allocated inside terminal it muses several problem such as traffic gam around terminal, high social and logistics cost and deterioration of terminal condition. This study, therefore, tries to evaluate the location of CFS, inside and outside of terminal, with respect to the social and logistics costs.

Strengthening Effect Analysis of Circular Concrete Column Strengthened with Laminated CFS (적층성을 띤 CFS로 보강된 원형 콘크리트 기둥의 보강효과 해석)

  • 이상호;허원석
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.89-100
    • /
    • 1999
  • The purpose of this study is to develop an analytic model of the concrete column strengthened with laminated CFS, and to provide a basic guideline for the strengthening design by CFS considering orthotropic properties of laminate. In this study, an analytical stress-strain model of laminated CFS is presented based on Tsai-Hill failure criterion. This model has been implemented in an algorithm which can evaluate the confinement effect of CFS. Through this algorithm, the stress-strain relationship of confined concrete is obtained and compared with experimental results of other studies. Using the constitutive relationships, section analyses of concrete column strengthened with CFS are done, and load-moment and load-curvature interaction curves are obtained. In addition, the strengthening effects of CFS according to various laminated angles are analyzed. Analytical results show that the strengthening effects of the strengthened concrete columns are significantly different in compression, flexure, and ductility according to the laminated ways. In compressive direction of principal stress shows the superiority, where an in flexural strengthening effects, [0/90]s does. In the aspect of ductility, [90]s shows the best effect.

Uniaxial Compression Behavior of RC Columns Confined by Carbon Fiber Sheet Wraps (탄소섬유쉬트로 구속된 RC 기둥의 일축압축 거동)

  • Han, Sang-Hoon;Hong, Ki-Nam
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.2
    • /
    • pp.207-216
    • /
    • 2005
  • External confinement by CFS (Carbon Fiber Sheet) is a very effective retrofit method for the reinforced concrete columns subject to either static or seismic loads. For the reliable and cost-effective design of CFS, an accurate stress-strain model is required for CFS-confined concrete. In this paper, uniaxial compression test on short RC column with square section was performed. To evaluate the effect of confinement on the stress-strain relationship of CFS-confined concrete, CFS area ratio and tie area ratio are considered. Based on the experimental results, a stress-strain model is proposed for concrete confined by CFS wraps. In the development of the model, the method to compute the actual hoop strains in CFS jackets at the rupture was examined and resolved. Overall, the results of the model agree well with test data.

Development of a Modified CFS Method in Forward-Link AOA Positioning (순방향 링크 AOA 측정치를 이용한 CFS 방법의 성능 개선)

  • Im, Hyun-Ja;Park, Ji-Won;Song, Seung-Hun;Sung, Tae-Kyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.639-644
    • /
    • 2009
  • This paper presents a modified CFS (Closed-Form Solution) for FLAOA (Forward Link AOA) measurements. During when the pseudo-measurement equation for FLAOA is derived, the angle measurement noise is treated more carefully in approximation. As the covariance matrix of the pseudo-measurement noise is influenced by unknown user positions and azimuth, a two-step estimation technique is used in the proposed CFS. The performance of the proposed CFS for FLAOA is compared to that of the conventional CFS for FLAOA and RLAOA (Reverse Link AOA) in a computer simulation. Simulation results show that the proposed method is potentially suitable for applications involving the localization and guidance of indoor mobile robots.

The Seismic Performance for Concrete-filled Steel Piers (콘크리트 충전 강교각의 내진 성능)

  • 정지만;장승필;인성빈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.189-196
    • /
    • 2002
  • The capacity of CFS piers has not been used to a practical design, because there is no guide of a seismic design for CFS piers. Therefore, the guide of a seismic design value is derived from tests of CFS piers in order to apply it to a practical seismic design. Steel piers and concrete-filled steel piers are tested with constant axial load using quasi-static cyclic lateral load to check ductile capacity and using the real Kobe ground motion of pseudo-dynamic test to verify seismic performance. The results prove that CFS piers have more satisfactory ductility and strength than steel piers and relatively large hysteretic damping in dynamic behaviors. The seismic performance of steel and CFS piers is quantified on the basis of the test results. These results are evaluated through comparison of both the response modification factor method by elastic response spectrum and the performance-based design method by capacity spectrum and demand spectrum using effective viscous damping. The response modification factor of CFS piers is presented to apply in seismic design on a basis of this evaluation for a seismic performance.

  • PDF

A Study on the Shear Behavior of Strengthened R/C Beams with CFS (탄소섬유쉬트로 보강한 R/C보의 전단거동에 관한 연구)

  • Shin, Sung-Woo;Bahn, Byong Youl;Lee, Kwang Soo;Cho, In-Chol;Nam, Jeong-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.3
    • /
    • pp.205-211
    • /
    • 1998
  • The purpose of this study is to evaluate shear strengthening effects of R/C beams with carbon fiber sheets. The major variables are shear reinforcement ratios, CFS strengthening ratios and strengthening methods of CFS. Following conclusions can be extracted. The shear capacity of beam strengthened with CFS is about 32~87% higher than that of beams without shear reinforcement. The strengthening effects of patch type is larger than those of strip type. The strain distribution in CFS intersected with shear crack is similar to that in stirrup and larger strain is observed in the middle of the shear span. It can be estimated that shear strength reduction factor ${\alpha}$=0.3 is appropriate for peeling effect of CFS.

  • PDF

A Study on the Axial Behavior of the Concrete Cylinders Confined by Carbon Fiber Sheets (탄소섬유쉬트로 횡구속된 콘크리트 공시체의 압축 거동에 관한 연구)

  • Hwang, Jin-Seog
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.4
    • /
    • pp.141-148
    • /
    • 2000
  • Recently the Carbon Fiber Sheet(CFS) is widely used for strengthening damaged RC structures. Strengthening compression members such as column can increase ductility and strength due to the confinement effect. In this experiment, the behavior of concrete cylinders confined by CFS was examined. The confinement pressure is increased linearly as axial stress is increased in low axial stress, and the confinement effect of CFS was rapidly developed after near maximum axial stress, thus axial strength and ductility was improved. As the ratio of CPS is increased, concrete cylinders failed due to local fracture of CFS. The confinement effect of circular section is more efficient than that of rectangular section. And significant improvement of axial strength, axial strain, transverse strain at failure is observed in circular section. This is because in rectangular section the local fracture of CFS near corner may be occured, thus the strain efficiency ratio must be considered for RC structures with CFS.

  • PDF

Anti-Biofilm Activity of Cell-Free Supernatant of Saccharomyces cerevisiae against Staphylococcus aureus

  • Kim, Yeon Jin;Yu, Hwan Hee;Park, Yeong Jin;Lee, Na-Kyoung;Paik, Hyun-Dong
    • Journal of Microbiology and Biotechnology
    • /
    • v.30 no.12
    • /
    • pp.1854-1861
    • /
    • 2020
  • Staphylococcus aureus is one of the most common microorganisms and causes foodborne diseases. In particular, biofilm-forming S. aureus is more resistant to antimicrobial agents and sanitizing treatments than planktonic cells. Therefore, this study aimed to investigate the anti-biofilm effects of cell-free supernatant (CFS) of Saccharomyces cerevisiae isolated from cucumber jangajji compared to grapefruit seed extract (GSE). CFS and GSE inhibited and degraded S. aureus biofilms. The adhesion ability, auto-aggregation, and exopolysaccharide production of CFS-treated S. aureus, compared to those of the control, were significantly decreased. Moreover, biofilm-related gene expression was altered upon CFS treatment. Scanning electron microscopy images confirmed that CFS exerted anti-biofilm effects against S. aureus. Therefore, these results suggest that S. cerevisiae CFS has anti-biofilm potential against S. aureus strains.

Validity Study of the Systemic Exertion Intolerance Disease Questionnaire (SEID-Q27) for Chronic Fatigue Syndrome (CFS) Diagnosis (SEID(Systemic Exertion Intolerance Disease) 진단 기준을 바탕으로 한 만성 피로 증후군 진단 설문지(SEID-Q27) 타당도 연구)

  • Lim, Eun-jin;Son, Chang-gue;Jang, Eun-su
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.6
    • /
    • pp.1015-1029
    • /
    • 2020
  • Purpose: This study assessed the validity of a questionnaire (SEID-Q27) for diagnosis of chronic fatigue syndrome (CFS), designed based on the systematic exertion intolerance disorder (SEID) criteria. Methods: Two groups of participants were recruited: 1. a non-CFS control group: adult university personnel with a Chalder fatigue scale (CFQ) score ≥15, and 2. a CFS patient group: patients from an online CFS community diagnosed with CFS (diagnostic code of G93.3) with the symptoms present. The survey ran from September to October, 2020. The validity of the questionnaire was investigated by factor analysis and receiver operator characteristic (ROC) analysis. Results: Among the 35 adults surveyed, 30 (86%) participants had CFQ scores ≥15 (15 males and 15 females) and 5 (14%) had a CFS diagnosis (2 males and 3 females). The total mean score was significantly different between the two groups (CFS: 6.8±2.2 vs. control: 4.4±2.4, p<0.05). The area under the curve (AUC) was 0.827. With a cut-off point 62, the sensitivity was 60%, specificity 97%, and the discriminant ability of the survey was 79%. Conclusions: The SEID -Q27 appears to be a useful instrument for the diagnosis of CFS using SEID criteria. However, further large-scale studies are needed with greater numbers of participants.