• Title/Summary/Keyword: CFs

Search Result 342, Processing Time 0.028 seconds

A study on the combination SCD, Pilot Filter and automatic coagulant feeding system in WTP (정수장 SCM, Pilot Filter와 자동응집제주입시스템의 조합에 관한 연구)

  • 최기선;임기영
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2001.12a
    • /
    • pp.19-22
    • /
    • 2001
  • In this paper, Streaming Current Monitor (SCM), Pilot Filter (PF) and Coagulant Feeding System(CFS) for fuzzy neural network are used as a coagulation control method in WTP and the results are compared. Several parameters such as coagulant dosage, pH, and turbidity have been changed to find the response characteristic of each equipment. SCM, PF and CFS responded for certain parameters but the range of sensitivity was different each other. It is demonstrated that WTP will be operated more efficiently when SCM, PF and CFS are used as coagulation control strategy.

  • PDF

An Experimental Study on Half Scale RC Slab Bridges Strengthened with Carbon Fiber Sheet (CFS로 보강된 모형 RC 슬래브 교량의 실험적 연구)

  • 심종성;김규선;김경민
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.537-542
    • /
    • 1999
  • The design methodologies for carbon fiber sheet(CFS) strengthening of RC structures are not well established yet because the structural behavior of strengthened RC structures is more complex than that of unstrengthened ones. Even though the research for the methods using CFS has beed studied, the strengthening effects and structural behaviors of strengthened structures are not systematized yet. The purpose of this study is to carry out the experimental studies on three kinds of half scale RC slab bridges and to investigate the behavior of RC slab bridges from the experimental results. Typical flexural failure occurs in the non-strengthening slab like general RC slab bridges, and also the flexural failure occurs in the all area strengthened slab with sudden rip-off failure of strengthening material by punching shear. For the case of strip type strengthened slab, flexural failure occurs, with rip-off of second strip at the base of loading point. Strengthening effect on the slab using CFS is that the strength is increased upto 7~15 percent and the crack pattern is changed.

  • PDF

Debonding and Crack of the R/C Beam Strengthened with CFS (CFS 보강 R/C 보의 균열 및 탈착)

  • Kim Chung Ho;Jang Hee Suc;Park Hyun Young;Ko Sin Woong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.173-176
    • /
    • 2005
  • This study look into the mechanisms of growth and magnification in the cracks and delamination on the beams repaired with CFS. The experimental parameters was a loading type, loading speed and pre-crack. In the experiments, it was confirmed that the failure of beams began with development and propagation of the delamination in the below the loading point due to magnification of cracks, but it was not concerned with loading type, loading speed and pre-cracks. Particularly, in the case of beams having the pre-cracks, growth of crack concentrated at the special crack below the loading point and led to failure of the beam by delamination due to magnification of crack.

  • PDF

Flexural Capacity Evaluation of RC Member Retrofitted by CFS and with Various Damage Level (탄소섬유로 휨보강된 RC 부재의 손상정도에 따른 보유내력평가)

  • Seo, Soo-Yeon;Kim, Kyong-Tae;Yoon, Seung-Joe;Yun, Hyun-Do;Choi, Chang-Sik;Choi, Gi-Bong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.326-329
    • /
    • 2006
  • Strengthening method using CFS have been developed for the rehabilitation of structures. However, it is very difficult to estimate their resistance capacity after retrofit. Therefore, damage information for strengthened structure with CFS investigated and the estimation method structural capacity by using the damage information is developed. The final objective of this research work is to propose the guideline and method for resistance capacity estimate of structure. In this paper, experimental study result with test parameters of number of carbon fiber sheets and bonding ratio is introduced.

  • PDF

Analytical Algorithm Predicting Compressive Stress-Strain Relationship for Concrete Confined with Laminated Carbon Fiber Sheets

  • Lee, Sang-Ho;Kim, Hyo-Jin
    • Computational Structural Engineering : An International Journal
    • /
    • v.1 no.1
    • /
    • pp.39-48
    • /
    • 2001
  • An analytical compressive stress-strain relationship model for circular and rectangular concrete specimens confined with laminated carbon fiber sheets (CFS) is studied. Tsai-Hill and Tsai-Wu failure criteria were used to implement orthotropic behavior of laminated composite materials. By using these criteria, an algorithm which analyzes the confinement effect of CFS on concrete was developed. The proposed analytical model was verified through the comparison with experimental data. Various parameters such as concrete strength, ply angle, laminate thickness, section shape, and ply stacking sequences were investigated. Numerical results by the proposed model effectively simulate the experimental compressive stress-strain behavior of CFS confined concrete specimens. Also, the pro-posed model estimates the compressive strength of the specimen to a high degree of accuracy.

  • PDF

Shear Strengthening of Pre-loaded RC Beams Retrofitted with CFS & Steel Plate (재하상태에 따른 탄소섬유쉬트 및 강판의 전단 보강 효과)

  • 김주연;신영수;홍건호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.775-780
    • /
    • 2000
  • This paper was aimed to investigate the shear strengthening effect of the pre-loaded reinforced concrete beams strengthened by carbon fiber sheet (CFS) & steel plate. Main test parameters were the magnitude of pre-loading at the time of the retrofit, the strengthening methods of carbon fiber sheet and aid ratio. A series of seventeen specimens was tested to evaluate the corresponding effect of each parameters such as maximum load capacity, load-deflection relationship, load-strain relationship and failure mode. As a result, using the steel plate can increase the capacity of not only shear but also bending moment.

  • PDF

A Study on the Bond Properties of Carbon Fiber Sheets used for Strengthening Structures (구조물 보강용 탄소섬유쉬트의 부착특성에 관한 연구)

  • 황진석;김지영;백명종;박형철;박칠림
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.653-658
    • /
    • 1997
  • Recently, carbon Fiber sheet (CFS) is frequently used for strengthening deteriorated concrete structures. To strengthening damaged structures, the property and characteristic of the bond between CFS and the concrete surface must be understood. The tensile test of single lap shear specimen was performed to study bond strength, bond stress distribution and stress transfer between CFS and concrete surface according to the bond length. Based on the test results, there were ultimate influence length (UIL) in which bond stress was distributed, and ultimate strain reduction ratio (USRR) by which strain was reduced linearly. Bond resisting force (BRF) was estimated by UIL and USRR, and which was compared with ultimate loads. According to the results of comparison, it was shown that ultimate bond strength could be estimated reasonablely by BRF.

  • PDF

A Study on Carbon Fiber Sheet Rehabilitation of Reinforced High Strength Concrete Beams (고강도 RC보의 탄소섬유쉬트 보강에 대한 연구)

  • 김종효;곽계환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.450-455
    • /
    • 1997
  • In recent years the research and development about the new material proceeds rapidly and actively in building industry. We are concerned with high-strength concrete as a new material. As the building structure becomes bigger, higher and more specialized, so does the demand of material and member with high strength for building expands greatly. In the future, we will quite need to research repair and rehabilitation to make high strength concrete structural building for our safe. So, I did an study on carbon fiber sheet rehabilitation(CFSR) of reinforced high strength concrete beams. The carbon fiber reinforced plastic(CFRP) bonding method is widely used for reinforcing the existing concrete structure among the various methods. The test results indicate that CFS is very effective for strengthening the damaged beams and controlling deflections of the repaired beams. When carbon fiber sheet rehabilitation of reinforced high strength concrete beams happened diagonal crack, the increase in the number of CFS layer didn't effect the increase in strength of beams. Also, by changing the CFS stick position gave diversified ultimate load in CFSR beams.

  • PDF

Bond between Carbon Fibers Sheet and Concrete (탄소섬유쉬트와 콘크리트의 부착)

  • 최근도;류화성;최기선;이한승;유영찬;김긍환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1019-1024
    • /
    • 2000
  • Carbon fiber sheet has been widely used for the strengthening of the concrete buildings structures due to its excellent physical properties such as high strength, lightness and high durability. Bond strength or behavior, on the other, hands, between carbon fiber sheet and concrete is very important in strengthening the concrete member using CFS. Also the bond failure mechanism between CFS and concrete should be fully verified and understood. This study is to investigate the bond strength of CFS to th concrete by the direct pull-out test and the tensile-shear test methods. From the tests, the average bond stress, $$\tau$_{y}$ and the effective bond length, $$\ell$_{u}$ are acquired.

Study on Strengthening Effect and Failure Behavior of CFS Strengthened High Strength RC Columns after Cross -sectional Shape Modification (4각기둥의 단면형상 변형 후 CFS로 보강한 고강도 철근 콘크리트 기둥의 보강효과 및 파괴거동 연구)

  • Jun Kyung-Suk;Kim Jang-Ho;Park Seok-Kyun;Kim Jin-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.259-262
    • /
    • 2005
  • Numerous studies showed that safety and serviceability of many concrete infrastructures and buildings built in 1970's have capacity less than their design capacities and thereby require immediate retrofitting. Currently, these aged concrete structure are being repaired using many repair and strengthening methods developed in the past. Therefore, in this study, a repairing and strengthening method for retrofitting high strength concrete columns that can effectively improve the performance of high strength concrete columns is developed. The square high strength concrete column's cross-sectional shape is modified to octagonal shape by attaching precast members on the surface of the column. Then, the octagonal column surface is wrapped using Carbon Fiber Sheets (CFS). The method allowed the maximum usage of confinement effect of externally wrapped CFS, which resulted in improved strength and ductility of repaired high strength concrete columns.

  • PDF