• 제목/요약/키워드: CFX 11

검색결과 73건 처리시간 0.022초

An Advanced Method for Behavior-Characteristics Analysis of Diesel Fuel Spray

  • Yeom, Jeong-Kuk
    • 동력기계공학회지
    • /
    • 제18권3호
    • /
    • pp.5-13
    • /
    • 2014
  • In order to control emissions from engine, it is necessary to understand the mixture formation process of diesel spray. In this study, analysis of diesel fuel(n-Tridecane, $C_{13}H_{28}$) spray under a high temperature and pressure was performed by a general-purpose program, ANSYS CFX release 11.0, and the results of these are compared with experimental results of diesel fuel spray using the Exciplex Fluorescence Method. The simulation results of diesel spray is analyzed by using the combination of Large-Eddy Simulation(LES) and Lagrangian Particle Tracking(LPT), and then injection pressure was selected as an analysis parameter. Consequently, it was found that the experimental results and the numerical results are consistent with each other, and then in order to investigate the behavior characteristics of evaporative diesel spray, the effectiveness of the use of CFX of commercial code is definitely validated.

다공성 구조물을 통과하는 댐 붕괴파의 전파특성에 관한 수치적 연구 (A Numerical Study on Propagation Characteristics of Dam-break Wave through a Porous Structure)

  • 정우창
    • 한국수자원학회논문집
    • /
    • 제47권1호
    • /
    • pp.11-24
    • /
    • 2014
  • 본 연구에서는 3차원 수치모형(ANSYS CFX model)을 이용하여 수조 내 다공성 구조물을 통과하는 댐 붕괴파의 전파특성에 대한 수치적 분석을 수행하였다. 다공성 구조물 내 및 주위에서의 수심분포에 대한 기존의 측정된 결과와 모의된 결과를 비교한 결과 비교적 잘 일치하는 것으로 나타났다. 또한 수조 내에 다공성 구조물이 부분적으로 존재하고 있을 경우에 대한 3차원 흐름구조를 수치적으로 분석하였다. 전반적으로 다공성 구조물이 존재하는 영역에 비해 존재하지 않은 영역에서 수심의 급격한 변동이 보다 크게 나타났으며, 따라서 다공성 구조물은 수심의 급격한 변동을 감소시키는 역할을 하는 것으로 나타났다.

이차원 이중 충돌제트에서 노즐과 충돌면 간격에 따른 유동 및 열전달에 관한 수치적 연구 (A Numerical Study of Flow and Heat Transfer on Two Dimensional Dual Impinging Jet on Nozzle to Plate Distance)

  • 김상길;김동건;김문경;윤순현;김봉환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2804-2809
    • /
    • 2008
  • Experimental results and numerical computations were conducted to investigate the effect of the confined wall on the flow and heat transfer characteristics for a two-dimensional impinging jet. Experimental results and Numerical solutions were obtained by using the particle image velocimetry and the commercial CFD code (CFX 11), respectively. The parameters studied were jet Reynolds number (Re=5,000), conditions of confined wall (unventilate), nozzle to plate spacings ($H/W=1{\sim}16$), and nozzle to nozzle spacing (S/W=6). Experimental and numerical results were agreed well with each other. The maximum heat transfer point was found variation of nozzle to plate spacings.

  • PDF

사이클론을 활용한 경량.저소음 진공집진 스탠딩 그라인더의 성능개선에 관한 연구 (A Study on Performance Improvement of Light and Low-Noisy Standing Grinder with Vacuum Dust Collection Using a Cyclone Separator)

  • 노태정
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.4732-4737
    • /
    • 2011
  • 진공집진 스탠딩 그라인더는 그라인딩을 하면서 동시에 발생하는 분진을 집진하는 것으로서, 산업현장에서 도장하기 전에 도장 표면이나 용접 후 비드 부위를 깨끗하게 하기 위하여 필요하다. 최근에 스탠딩 그라인더는 연마 및 분진집진 용량이 커졌으나 반면에 발생소음이 적고 컴팩트하고 포터블화하는 추세이다. 이러한 연마와 집진 성능이 증가함에 따라서 소음과 중량이 중요한 문제로 야기된다. 이러한 문제를 해결하기 위하여 효율적인 사이클론을 Ansys-CFX에 의하여 해석하여 설계하고 실험을 거쳐서 개발되었으며, 그 결과, 그라인더부의 중량은 5.9kg로서 작업자가 충분히 들고 작업을 할 수 있으며, 개발 제품의 소음은 69.9dB(A)로서 좋은 결과를 얻었다.

3상 GIS Busbar내 자연대류에 대한 수치해석적 연구 (A Numerical Study on Natural Convection in A Three-Phase GIS Busbar)

  • 왕양양;한성진;김중경;강상모
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.107-108
    • /
    • 2008
  • The temperature rise of GIS (Gas Insulated Switchgear) busbar system is a vital factor that affects its performance. In this paper, a two-dimensional model is presented by commercial code CFX11 for the evaluation of natural convection in the busbar system. In the model, SF6 (Sulfur Hexafluoride) is used to insulate the high voltage device and improves the heat transfer rate. The power losses of a busbar calculated by the magnetic field analysis are used as the input data to predict the temperature rise by the nature convection analysis. The heat-transfer coefficients on the boundaries are analytically calculated by applying the Nusselt number considering material property and model geometry for the natural convection. The temperatures of the tank and conductors from CFX simulation and the experiment were compared. The results show a good agreement. In the future, we will calculate the 3-D model and try to reduce the temperature by adjusting some dimensional parameters.

  • PDF

증발디젤분무의 거동특성해석을 위한 계산기법 적용에 관한 기초 연구 (Basic Study on the Application of a Computational Technique to Behavior Characteristics Analysis of the Evaporative Diesel Spray)

  • 염정국
    • 동력기계공학회지
    • /
    • 제14권6호
    • /
    • pp.5-12
    • /
    • 2010
  • In this study, an analysis of evaporative diesel spray and an usefulness of a general-purpose program, ANSYS CFX release 11.0, are investigated through the comparison and investigation of the experimental results carried out under an evaporative field, in which there is phase transition, by an exciplex fluorescence method and the results analyzed by the CFX program. The diesel fuel called n-Tridecane, $C_{13}H_{28}$, is injected from a single-hole nozzle (l/d=1.0mm/0.2mm) into a constant volume chamber under a high temperature and pressure. In the same condition as the experimental condition, the analysis was carried out. Both results of the spray tip penetration were almost coincident at each time. The results have validated the usefulness of this analysis. As a result, if the ambient pressure is high, the spray tip penetration will be shortened and move toward the nozzle exit.

PCB회로 보드장치내의 안정적 방열설계를 위한 연구 (The stable design of radiant heat inside PCB circuit board device)

  • 원종운;이종휘
    • 대한안전경영과학회지
    • /
    • 제15권2호
    • /
    • pp.129-134
    • /
    • 2013
  • In this study, the heat flow analysis compatible commercial code CFX 11 was used to develop the structure inside PCB circuit board devices, which could stable radiant heat as well as the cooling device within it. In case of modifying the arrangement of electronic parts on the PCB inside the multi channel temperature measurement board devices, radiant heat effects did not show a rising tendency, whereas the overall temperature went down in case of installing the vents in the outer case of PCB circuit board devices. In terms of installation location, it was the most appropriate to install it on the electronic parts with no heat. Besides, in case of mounting the fan as a cooling device by considering various user environments for multi channel temperature measurement board devices, the radiant heat effects were shown higher than in case of installing the vents, and the middle sections were the most appropriate to its installation location. In case of changing the wind quantity of the fan from its selected installation location, the best radiant heat effects were shown at high speed as expected.

ANSYS와 CFX를 이용한 방풍벽의 구조 안전성 분석 (Analysis of the Structural Safety of a Wind-Protecting Wall Using ANSYS/CFX)

  • 염성현;김철수;최영돈
    • 생물환경조절학회지
    • /
    • 제15권2호
    • /
    • pp.138-148
    • /
    • 2006
  • 대립계 포도 비가림하우스에 부착된 일체형 방풍벽과 노지에 설치된 분리형 방풍벽의 구조 안전성을 설계풍속 $30.9m{\cdot}s^{-1}$$50m{\cdot}s^{-1}$ 조건에서 각각 분석하였다. 비닐하우스 부착형 방풍벽의 경우, 방풍벽을 설치했을 때 방풍벽의 경사각이 측면부의 유동분포에 미미한 변화를 주어 측면부가 받는 풍압면적이 다소 감소하는 것으로 나타났으나 큰 차이를 보이지는 않았다. 그러나 구조강도 측면에서는 방풍벽 설치를 위한 부가적인 파이프 투입 효과로 약 11%정도 구조 안전성이 향상되는 것으로 분석되었다. 주기둥 간격이 3m인 분리형 방풍벽의 경우,대형 태풍수준인 $50m{\cdot}s^{-1}$에서 구조적으로 불안정한 것으로 나타났으며 분리형 방풍벽의 이론적 고찰 결과와 해석 결과와는 큰 차이를 보여 3차원으로 구성된 구조물의 2차원 모델 시 그 정확성에 한계가 있음을 알 수 있었다. 추후 분리형 방풍벽의 효용성을 증대하기 위하여 최적 파이프 규격 설정에 관한 세부적인 연구가 필요할 것으로 판단되며 비닐하우스 부착형 방풍벽의 경우, 태풍으로 인한 비닐하우스 피해 발생 시 정밀한 피해실태 조사를 통하여 분석 결과의 정확성을 향상시킬 수 있는 구조 안전성 분석 기법 개발에 관한 연구가 필요한 것으로 판단되었다.

풍동실험을 통한 국화군락의 공기유동 저항 분석 (Analysis for Aerodynamic Resistance of Chrysanthemum Canopy through Wind Tunnel Test)

  • 유인호;윤남규;조명환;이인복
    • 생물환경조절학회지
    • /
    • 제17권2호
    • /
    • pp.83-89
    • /
    • 2008
  • 작물은 복잡한 형상 때문에 CFD모델에서 다공성 매체로 설계된다. 작물이 고려된 CFD 모델 해석을 위해서는 작물군락의 공기저항값을 입력하여야 하며, 이 값은 작물에 따라 달라진다. 본 연구에서는 풍동실험을 통해 국화군락의 공기저항 값을 구하였다. 풍상측에서는 풍속과 재식밀도가 증가할수록 정압이 증가하였다. 풍하측에서는 풍속이 증가할수록 정압이 낮아졌으나 재식밀도의 영향은 크게 받지 않는 것으로 나타났다. 풍속과 재식밀도가 증가할수록 풍상측과 풍하측의 압력차가 커지는 것으로 나타났다. 국화군락의 공기저항값인 항력계수 $C_d$값은 0.22였으며, Fluent 프로그램의 공기저항 계수로 이용한다. CFX 프로그램에서 필요로 하는 다공성 매체의 특성값 $K_Q$는 재식간격 $9{\times}9cm$일 때 2.22, $11{\times}11cm$일 때 1.81, $13{\times}13cm$일 때 1.07이었으며, 이 값을 CFX 프로그램의 quadratic resistance coefficient로 입력한다.

선박 엔진용 고압 3/2-Way 밸브의 유동특성 연구 (A Study on the Flow Characteristic of High Pressure 3/2-Way Valve for a Ship Engine)

  • 박시범;김진미;이철재;강정호
    • 한국기계가공학회지
    • /
    • 제11권3호
    • /
    • pp.35-40
    • /
    • 2012
  • The 3/2-way valve supplies the high pressure air to ship engine for starting engine. In this paper, the high pressure 3/2 way valve for ship engine has the goal as reverse engineering by searching the fluid characteristic at this valve. The reverse engineering of 3/2-way valve is measured directly by Verier-calipers and is compared with 3D scanner. The fluid characteristic in this valve is used for a simulation method by ANSYS CFX 12.1. On the contrary, discs and the shaft are as the important components on numerical simulation by controlling the air flow at this valve. The fluid characteristics are seen to make high velocity and complicated vortex around the shaft. And the flow coefficient is calculated in order to apply for industrial field.