• 제목/요약/키워드: CFD-ACE

검색결과 114건 처리시간 0.023초

Anti-Cavitation Trim을 갖는 고차압 제어밸브의 유동특성에 관한 수치해석 (Numerical Analysis on Flow Characteristics of High Pressure Drop Control Valves with Anti-Cavitation Trim)

  • 안영준;김병진;신병록
    • 한국유체기계학회 논문집
    • /
    • 제10권4호
    • /
    • pp.61-70
    • /
    • 2007
  • Numerical analysis of three dimensional incompressible turbulent flows in LNG marine high pressure drop control valves was carried out by using the CFD-ACE from ESI-Group. In this study, flow characteristics of control valves with complex flow fields including cavitation effect were investigated. Simulation was performed on five models of control valve that had different orifice diameters of anti-trim and the size of valve. Comparing newly designed control valves for controling the occurrence of cavitation with the conventional valve, new valves showed a improved flow pattern with almost no cavitation.

난류 예혼합연소 화염의 LES 및 산업용 연소기 개발을 위한 LES 응용 해석 기술 (LES OF TURBULENT PREMIXED COMBUSTION FLAME AND LES APPLICATION FOR THE INDUSTRIAL COMBUSTOR DEVELOPMENT)

  • 박남석;류종력
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.437-441
    • /
    • 2010
  • LES results of turbulent premixed combustion flows are introduced by using the dynamic sub-grid scale model based on G-equation describing the flame front propagation. The turbulent premixed combustion flows around bluff body and over backward facing step are analyzed to validate present formation. LES of swirling partially premixed combustion flame is also performed to conform the predictive capabilities of LES model and to prompt our understanding for the combustion flows over double cone swirl burner combustor by using CFD-ACE+ commercial code.

  • PDF

연료 전지 냉각판의 최적 설계 (A Study on the Optimization of Fuel-Cell Stack Design)

  • 홍민성;김종민
    • 한국공작기계학회논문집
    • /
    • 제12권6호
    • /
    • pp.92-96
    • /
    • 2003
  • Feul-Cell system consists of fuel reformer, stack and energy translator. Among these parts, stack is a core part which produces electricity directly. In order to set a stack module, fabrication of appropriate stack, design of water flow path in stack and control of coolant are needed. Especially, oater or air is used as a coolant to dissipate heat. The different temperature of each electric cell after cooling affects the performance of the stack. Therefore, it is necessary that the relationship between coolant hearing rate, width of stack, properties of stack, and the shape of water flow path must be understood. For the optimal design, the computational simulation by CFD-ACE has been conducted and the resulting database has been constructed.

미소유체요소 내부유동의 3차원 측정 및 수치해석 (Three-dimensional Flow Structure inside a Plastic Microfluidic Element)

  • 이인원;안광협;남영석;이인섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.419-422
    • /
    • 2002
  • A three-dimensional inlet flow structure inside a microfluidic element has been investigated using a micro-PIV(particle image velocimetry) measurement as well as a numerical analysis. The present study employs a state-of-art micro-PIV system which consists of epi-fluorescence microscope, 620nm diameter fluorescent seed particles and an 8-bit megapixel CCD camera. For the numerical analysis, a commercial software CFD-ACE+(V6.6) was employed for comparison with experimental data. Fixed pressure boundary condition and a 39900 structured grid system was used for numerical analysis. Velocity vector fields with a resolution of $6.7{\times}6.7{\mu}m$ has been obtained, and the attention has been paid on the effect of varying measurement conditions of particle diameter and particle concentration on the resulting PIV results. In this study, the microfluidic elements were fabricated on plastic chips by means of MEMS processes and a subsequent melding process.

  • PDF

플라즈마 펄싱을 이용한 건식 식각 공정의 수치 모델링

  • 주정훈;김남헌
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.216.2-216.2
    • /
    • 2014
  • 플라즈마의 연속 운전 조건은 플라즈마 발생원의 기하적, 전기적 특성에 의한 공정 특성을 갖는다. RF power를 pulsing하는 경우 off시간에 하전 입자와 중성 라디칼의 소멸 특성의 차이로 인하여 나노 미세 구조의 식각에 유리한 측면이 있다. 유도 결합 플라즈마원을 주발생원으로 이용하는 건식 식각장비의 기판 바이어스를 rf pulsing하는 경우 유체 모델을 이용한 계산 방법에서 rf off 시간 중의 2차 전자 발생 계수를 rf on time시와 동일 하게 계산하거나 입사 이온의 에너지와 무관하게 0.05 등의 상수로 처리하는 경우가 많은데 본 연구에서는 rf bias off 시간 동안의 SEC(secondary electron coefficient)를 변화시키는 조건이 플라즈마의 특성에 어떤 영향을 미치는지 CFD-ACE+에 user subroutine을 이용하여 조사하였다.

  • PDF

Numerical Modeling of an Inductively Coupled Plasma Sputter Sublimation Deposition System

  • Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • 제23권4호
    • /
    • pp.179-186
    • /
    • 2014
  • Fluid model based numerical simulation was carried out for an inductively coupled plasma assisted sputter deposition system. Power absorption, electron temperature and density distribution was modeled with drift diffusion approximation. Effect of an electrically conducting substrate was analyzed and showed confined plasma below the substrate. Part of the plasma was leaked around the substrate edge. Comparison between the quasi-neutrality based compact model and Poisson equation resolved model showed more broadened profile in inductively coupled plasma power absorption than quasi-neutrality case, but very similar Ar ion number density profile. Electric potential was calculated to be in the range of 50 V between a Cr rod source and a conductive substrate. A new model including Cr sputtering by Ar+was developed and used in simulating Cr deposition process. Cr was modeled to be ionized by direct electron impact and showed narrower distribution than Ar ions.

채널 단면형상 변화에 따른 PEMFC 성능 수치 연구 (Numerical Study on the Performance of PEMFC with Various Cross Sections of Channel)

  • 최치환;문정은;이규정
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.186-192
    • /
    • 2005
  • A numerical study on the performance of a PEMFC was performed by using a CFD-ACE+commercial program. The effects of width, hight and shape of channel cross section and mass flow rate were investigated. In order to check the validity of the simulation, comparisons were carried out between predictions and experimental data available in the literature and shows the reasonable agreement. It is found that only the width of channel is strongly related to the performance of a PEMFC, while other factors have no marked effects.

  • PDF

침형 상압 마이크로 플라즈마 장치에서 발생하는 전기장이 세포 사멸에 미치는 효과 (The effect of RF electric fields from an atmospheric micro-plasma needle device on the death of cells)

  • 윤현진;손채화;김규천;이해준
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2249-2254
    • /
    • 2008
  • A non-thermal micron size plasma needle is applicable for medical treatment because it includes radicals, charged particles, ultraviolet emission, and strong electric fields. The electric fields around the plasma needle device driven by a radio frequency wave are investigated in order to calculate the power delivered to the cell. A commercial multi-physics code, CFD-ACE, was utilized for the calculation of electric fields for the optimization of the needle structure. The electric field and energy absorption profiles are presented with the variation of the device structure and the distance between the needle and tissues. The living tissues effectively absorb the radio frequency power from the plasma needle device with the covered pyrex structure.

캐비테이션 벤튜리의 유량제어 성능 (Performance of Flow Rate Control of a Cavitating Venturi)

  • 조원국;문윤완;김영목
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 춘계 학술대회논문집
    • /
    • pp.146-151
    • /
    • 2002
  • Characteristics of flow rate control has been studied for a cavitating venturi adopted in a liquid rocket propellant feed system. Numerical simulation has been peformed to give about $10\%$ discrepancy of mass flow rate to the experimental data for cavitating flow regime. Mass flow rate is confirmed to be saturated for pressure difference higher than $3\times10^5$pa when the upstream pressure is fixed to $22.8\times10^5$pa and the downstream pressure is varied. The evaporation amount depends substantially to non-condensable gas concentration. However the mass flow rate characteristic is relatively insensitive to the mass fraction of non-condensable gas. So it is reduced by only $2\%$ when the non- condensable gas concentration is increased from 1.5PPM to 150PPM. From the previous comparison the expansions of the non-condensable gas and the evaporation of liquid are verified to have same effect to pressure recovery.

  • PDF

버너의 위치에 따른 알루미늄 용해로내의 유동 및 열전달 (Flow and Heat Transfer along Burner Positions in Aluminium Pool Furnace)

  • 김진호;강덕홍;김기홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1207-1212
    • /
    • 2004
  • For the design of Aluminium pool furnace, position of burner and pool depth effects on flow and temperature field in Aluminium pool furnace are examined by the commercial computational code, CFD-ACE+. From the results, position of burner which is on the same face in side wall is better to distribute the flow field in Al furnace. That yields temperature to distribute more uniformly. And the burner position is on upper wall, fire frame reach pool surface. Customer must consider that, because it make Aluminium to oxidize.

  • PDF