• 제목/요약/키워드: CFC-Alternatives

검색결과 33건 처리시간 0.019초

Dean Vortices를 이용한 막모듈의 성능시험 (Performance Test for Membrane Module Using Dean Vortices)

  • Chung, Kun Yong;Belfort, Georges
    • 멤브레인
    • /
    • 제2권2호
    • /
    • pp.104-111
    • /
    • 1992
  • A curved channel duct is designed, built and used specifically to produce Dean vortices as a result of flow around a $180^{\circ}C$ curve. We present evidence using optical reflection of the existmace of the vortices in the curved section and following flat section. Also, three different feed soludons(DI water, a monodispersed styrene-divinyl-benzene latex particle suspension and a yeast suspension) were used to determine the effectiveness of Dean instabilities to destabilize polarization layers. For each suspension, the flux data were compared as a function of time for flow conditions with and without Dean vortices, for a $0.2{\mu}m$ microfiltration membrane. Any permeation flux improvement was not sustained for $2.0De_c$ due to the vortex-decay in the flat section after the curved channel, but a 15~30% permeation improvement was obtained for $3.8De_c$.

  • PDF

대체 소화제의 열역학적 물성 비교 (Comparison of Thermodynamic Properties of Alternative Fire Extinguishing Agent)

  • 김재덕;여미순;이광진;이윤우;장윤호;노경호
    • 한국화재소방학회논문지
    • /
    • 제18권1호
    • /
    • pp.7-12
    • /
    • 2004
  • 몬트리올 의정서에 의해서 규제 받는 CFCs와 Halon의 대체 물질인 HFC-23, HFC-125, HFC-227ea, HFC-236fa와 불활성 화합물 $Ar, N_2, CO_2$의 열역학적 물성인 포화압력, 밀도, 엔탈피, 점도를 비교하였다. 본 연구에서는 소화제의 물성을 문헌 값을 온도의 함수로서 표시하였다. HFC 화합물의 열역학적 물성은 Halon-1301과 비슷하게 나타내었다. 불활성 화합물은 주로 혼합물로 이용되지만, 불활성 화합물의 물성은 Halon-1301에 비하여 바람직하지 않았다.

R-502의 대체냉매를 사용한 냉동시스템의 성능 및 열전달 특성 (Performance and heat transfer characteristics of refrigeration system using R-502 alternatives)

  • 박창대;김민수;노승탁
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.624-632
    • /
    • 1999
  • In order to replace CFC-502 which has been widely used in transportation and low temperature refrigeration system, performance tests using HFC-407A, HFC-404A and HFC-507 have been carried out. Measurements were conducted at two different condensing temperatures of $43.3^{\circ}C$and $54.5^{\circ}C$ for each refrigerant. System performance characteristics and heat transfer characteristics of each refrigerant were obtained at several compressor speeds and evaporating temperatures ranging from$-25^{\circ}C$ to $-10^{\circ}C$ Test results show that the use of tested alternative refrigerants without changing system components offers the potential performance improvement of a refrigeration system.

  • PDF

수계세정제의 계면활성제 종류에 따른 물성, 세정성 및 유수분리 영향 연구 (Effect of surfactant types in aqueous cleaning agents on their physical properties, cleaning ability and oil-water separation)

  • 박선우;차안정;김현탁;김한성;배제흠
    • 청정기술
    • /
    • 제9권1호
    • /
    • pp.9-21
    • /
    • 2003
  • CFC-113, 1,1,1-TCE는 오존파괴물질로 선진국에서는 이미 사용이 전면 규제되고 있고 MC, TCE는 유해성 또는 발암성물질로 판명되어 일부사업장에서 제한적으로 사용되고 있다. 그러므로 세정성이 좋고 환경/안전성이 우수한 대체세정제를 개발하여 사용하거나 기존 개발된 세정제 중에서 우수한 세정제를 선정하여 사용하는 것이 필요한 실정이다. 대체세정제로는 수계세정제가 환경성과 경제적면에서 유망한 것으로 평가받고 있어 많은 사업장에서 사용될 전망이다. 본 연구에서는 환경친화적인 수계세정제를 개발하기 위하여 수계세정제의 주요성분인 여러 형태의 계면활성제를 선정하여 이들의 물성, 거품성, 오염물 종류에 따른 세정성, 유수분리성을 평가하여 비교하였다.

  • PDF

대체혼합냉매를 사용하는 Lorentz-Meutzner의 이중 증발기 냉동 시스템의 성능에 관한 연구 (A Study of Lorentz-Meutzner's Two Evaporator Refrigeration System Using Alternative Refrigerant Mixtures)

  • 박영무
    • 설비공학논문집
    • /
    • 제4권2호
    • /
    • pp.123-136
    • /
    • 1992
  • A preliminary thermodynamic design model of two-evaporator refrigerator/freezer system is constructed. This system is based on Lorentz-Meutzner cycle using refrigerant mixtures. This model screens alternative refrigerant (R32, R125, R143a, R22, R134a, R152a, R124, R142b, R123) mixtures to select the best performance-giving refrigerant mixtures and its composition for the system. Also, it estimates the effects of cooling temperatures of intercoolers, evaporator's area ratio, cooling load ratio on the performance of the system. The COP of the system ranges from 1.4 to 1.6, which is superior to that of the single evaporator system charged with R12 by 13% to 29%. Among 15 mixtures, R22/R123, R143a/R123, R32/R142b, and R32/R124 (in the order of high COP) are most recommendable. For the case of R22/R123, R22 mass fraction more than 0.5(Load Ratio=1.0) or 0.7(Load Ratio=0.33) is recomended in order to replace R12 without reduction in volumetric capacity when keeping the compressor as the same one. COP has the highest value with X(R22)=0.7 and 0.8, respectively. For the case of R143a/R123, in the similar manner, mass fraction of R143a is more than 0.5 or 0.6 while best performance occurs at X(R143a)=0.8. Higher temperature intercooler is more important for the performance of the system than lower temperature intercooler. The area ratio of evaporators is roughly proportional to load ratio of the evaporators.

  • PDF

Pd담지촉매와 고체산촉매를 이용한 HCFC-142b의 탈염소반응 (Dechlorination of HCFC-142b over Supported Pd Catalysts and Solid Acid Catalysts)

  • 한광영;서경원;목영일;박건유;안병성
    • 공업화학
    • /
    • 제9권3호
    • /
    • pp.372-376
    • /
    • 1998
  • Pd를 지지체에 담지시킨 촉매($Pd/AlF_3$, $Pd/{\gamma}-Al_2O_3$)와 고체산촉매(${\gamma}-Al_2O_3$, ${\alpha}-Al_2O_3$, $AlF_3$)를 제조한 후 수소분위기에서 HCFC-142b(1-chloro-1,1-difluoroethane)의 탈염소반응을 수행하여 반응온도, 수소/HCFC-142b의 공급비(r) 및 Pd담지량 변화가 HFC-143a(1,1,1-trifluoroethane)와 HFC-152a(1,1-difluoroethane)로의 선택도에 미치는 영향을 조사하였다. 실험결과 $Pd/AlF_3$$Pd/{\gamma}-Al_2O_3$촉매에 의한 전환율은 각각 60%와 92%였고, 생성가스 중에서 HFC-143a로의 선택도는 각각 58%와 64%였다. 이때 최적반응조건은 반응온도, $200^{\circ}C$, 공간시간 1.05s, 수소/HCFC-142b의 공급비가 3이었다. 한편, 동일 조건하에서 ${\gamma}-Al_2O_3$${\alpha}-Al_2O_3$, 그리고 $AlF_3$촉매에 의한 HCFC-142b의 생성가스로의 전환율은 각각 12%, 8%와 7%였고, 생성가스중 HFC-152a로의 선택도는 각각 94%, 92%와 90%였다.

  • PDF

니오비움 함유 복합 금속산화물 촉매의 선택산화반응에 관한 연구 (Studies on the Selective Oxidation of Niobium Containing Mixed Metal Oxide Catalysts)

  • 김영철;김형주;문동주
    • 공업화학
    • /
    • 제9권1호
    • /
    • pp.129-134
    • /
    • 1998
  • 프로판의 아크릴로니트릴로의 가암모니아 산화반응을 $Nb_2O_5-V_{0.4}Mo_1Te_{0.1}$ 혼합촉매를 이용하여 연구하였다. 가암모니아 산화반응의 촉매적 활성은 강한 산성을 띠는 니오피움산화물을 몰리브덴계 산화물촉매($V_{0.4}Mo_1Te_{0.1}$)에 첨가함에 따라서 증가하였으며, 이때 아크롤로니트릴과 프로필린의 선택율은 일정하게 유지되었다. 최대의 활성은 $Nb_2O_5-V_{0.4}Mo_1Te_{0.1}$ 촉매 중 니오비움산화물이 25wt%가 되었을 때 얻었으며, 니오비움산화물은 프로판의 탈수소과정에 선택적인 촉매임을 알았다.

  • PDF

R-134a의 열역학적 물성치 계산과 냉동 성능에 관한 연구 (Calculation of the Thermodynamic Properties of R-134a and A Preliminary Study of the Refrigeration Performance)

  • 박영무;이홍원
    • 설비공학논문집
    • /
    • 제3권4호
    • /
    • pp.286-296
    • /
    • 1991
  • The thermodynamic properties of R134a, the prospective R12 alternative, have been computerized using Martin-Hou equation of state and the coefficients given by Willson-Basu. Several experimental results in literatures for PVT data, saturated vapor pressure, saturated liquid density are compared with the calculated results to investigate the accuracy. The average deviation (max. deviation) is 0.13% (0.25%) for saturated liquid density, 0.25% (0.8%) for PVT data. Thermodynamic properties, enthalpy, entropy are compared with the NIST's. The maximum percent difference is 3% for saturated liquid enthalpy, 1.5% for saturated vapor enthalpy, 4% saturated liquid entropy, and 0.7% for saturated vapor entropy. Correction of W-B's coefficients and inclusion of the sixth term of M-H EOS for improvement of accuracy are recommended. R134a and R12 are compared with respect to refrigeration performance. COP's are different from each other within 3%. Refrigeration effect of R134a is superior to that of R12 but refrigeration capacity of R134a is inferior to that of R12 because the volumetric efficiency of the system using R134a is lower than that of the system using R12.

  • PDF

원판틀형 역삼투 모듈을 이용한 분리 특성 해석 (Analysis of the Separation Using Disc Plate and Frame Type Reverse Osmosis Module)

  • 정건용;정욱;원장묵;배성렬;하백현
    • 멤브레인
    • /
    • 제5권2호
    • /
    • pp.81-88
    • /
    • 1995
  • NaCl과 sucrose 용액을 역삼투용 워난틀형 모듈에 공겁하여 투과실험하였으며 Kimura-Sourirajan[8]이 제안한 방법으로 분리성능을 분석하였다. 사용한 분리막의 순수투과계수는 압력에 무관하게 $2.17 \times 10^{-6}$(gmol/$cm^2$-sec-bar)로 일정하게 유지되었다. Sucrose 용액의 농도분극화 현상은 NaCl 용액보다 심각하였으며 40bar 이상에서는 압력이 증가함에 따라서 오히려 투과선속이 감소하였다. 용질 배제율은 NaCl 수용액의 경우 압력이 증가함에 따라서 감소하였으나 sucrose 수용액의 경우는 압력에 따라서 배제율도 증가하였다.

  • PDF

시판 수계/준수계 세정제의 세정성 및 환경성 평가 연구 (Evaluation of Cleaning ability and Environmental Evaluation of Commercial Aqueous/Semi-aqueous Cleaning Agents)

  • 차안정;박지나;김한성;배재흠
    • 청정기술
    • /
    • 제10권2호
    • /
    • pp.73-87
    • /
    • 2004
  • 세정은 거의 모든 산업분야에서 필요한 중간 공정으로 대부분의 산업분야에서 제품상의 이물질 제거를 위해 세정을 실시고 있으며 세정제로 CFC-113, 1,1,1-TCE (1,1,1-trichloroethane), MC (methylene chloride), TCE 등 과 같은 세정성과 재질호환성이 양호한 염소계세정제를 사용하여 왔다. 그러나 CFC-113, 1,1,1-TCE는 오존파괴 물질로 선진국에서는 이미 사용이 금지되어 있고 MC, TCE는 유해성 또는 발암물질로 판명되어 일부사업장에서 제한적으로 사용되고 있다. 그러므로 세정성이 좋고 환경/안전성이 우수한 대체세정제를 개발하여 사용 하거나 기존 개발된 세정제 중에서 우수한 세정제를 선정하여 사용하는 것이 필요한 실정이다. 대체세정제로는 수계/준수계세정제가 환경성과 경제적면에서 유망한 것으로 평가받고 있어 많은 사업장에서 사용될 전망이다. 이에 본 연구에서는 시판되고 있는 수계세정제 12종, 준수계세정제 6종을 선정하여 물성, 세정성, 헹굼성, 헹굼수 재활용성 등에 관한 비교 연구를 수행하였다. 그 결과 수계세정제는 습윤지수가 클수록 세정이 좋았지만 준수계세정제는 습윤지수와 연관이 없었다. 그리고 수계세정제와 준수계세정제에 의한 세정성과 헹굼성을 좋게 유지하기 위하여서는 일정농도 이하로 오염물의 농도 관리가 필요한 것으로 나타났다. 수계, 준수계세정제는 종류에 따라서 단순 정치분리법에 의하여 헹굼수 중의 오염물을 70% 이상 용이하게 제거할 수 있었다. 이것은 일부 세정제는 오염된 헹굼수 중에서 높은 유수분리 효율이 있어 헹굼수 중의 오염물을 제거하고 물을 재활용하는데 효율적임을 말해준다. 그리고 수계세정제가 함유된 오염물은 30 kDa 세공크기의 PAN 막을 사용한 한외여과방법에 쉽게 정화될수 있었다.

  • PDF