HFC-134a 자동차용 공조시스템의 열역학적 사이클 특성에 관한 연구 (A Study of Thermodynamic Cyclic Characteristics of HFC-134a Automotive Air-Conditioner System)

  • 이규현;원종필
    • 한국자동차공학회논문집
    • /
    • 제2권1호
    • /
    • pp.51-64
    • /
    • 1994
  • Analytical study on the thermodynamical cyclic behabiour and characteristics of HFC-l34a refrigerant for automotive air conditionser system for the replacement of existing CFC-12 has been carried out in this paper through development of system performance simulation program, expecially in the view point of system design considerations. The results indicate that HFC-l34a system will give a greater refrigerating capacity than CFC-12 if appropriate engineering measures such as proper codensers, flow controllers, etc., taken for certain operating conditions. The results, however, also show that the operating power for compression process increases over entire temperature range as a result of decreasing volumetric efficiency due to larger specific volume and increased discharging pressure. The present study results indicate that proper selection of condensing and evaporating temperature plus refrigerant control is very important performance factor to have better COP in the HFC-134a system design.

  • PDF

Rl23, R134a냉매 특성에 따른 증발기 설계 (Design of an evaporator heat exchanger for R123 and R134a refrigerants)

  • 김익생
    • 대한설비공학회지:설비저널
    • /
    • 제28권5호
    • /
    • pp.368-374
    • /
    • 1999
  • 최근 세계적으로 환경보호에 대한 관심이 고조됨에 따라 기술개발 방향이 환경을 고려한 규정 및 장치에 제한을 받고 있다. 따라서 냉동 공조 기기에 사용되는 기존의 CFC계열 냉매가 오존층 파괴의 주 원임이 판명됨에 따라 환경 문제가 없는 HCFC계열인 R123와 HFC R134a로의 대체가 불가피하게 되었다.

  • PDF

동심 원통형 Halbach 배열 영구자석을 이용한 상온 자기냉동장치 (Magnetic Refrigeration Apparatus at Room Temperature Using Concentric Halbach Cylinder Permanent Magnets)

  • 이창호;이종석
    • 대한기계학회논문집B
    • /
    • 제41권1호
    • /
    • pp.47-51
    • /
    • 2017
  • 근래에 들어서 증기 압축식 냉동시스템으로 인한 대기환경 오염문제를 해결하기 위해 국제적 공조의 분위기가 형성되고 있다. 그래서 그 환경오염의 주원인으로 지적되는 CFC 냉매를 대체하는 냉동기술이 큰 주목을 받고 있다. 자기냉동은 물질의 자기열량효과를 이용하여 저온을 생성시키는 방법으로, CFC 냉매를 사용하는 대신에 고체 냉매를 사용함으로써 친환경적인 냉동 기술이라고 할 수 있다. 또한 전력 소모와 소음이 큰 압축기를 사용하지 않고, 자기장의 변화에 따른 재료의 온도 변화를 이용하여 저온부와 고온부의 온도차를 발생시킬 수 있어서 효율적인 냉동시스템으로 간주된다. 본 논문에서는 동심 원통형 Halbach 배열의 영구자석을 이용한 자기냉동장치를 제작하고, 이 장치를 이용하여 실험한 결과를 소개하고자 한다.

R12 및 R22대체냉매의 열역학적 물성치 및 냉동기의 성능비교 (Thermodynamic Properties of Alternatives for R12, R22 and Performances of Refrigerator)

  • 장세동;신지영;노승탁
    • 설비공학논문집
    • /
    • 제5권1호
    • /
    • pp.73-83
    • /
    • 1993
  • Thermodynamic properties of alternatives for R12 and R22 were estimated and performances of refrigerating cycle using these refrigerants were compared. In this study, we adopt R134a, R22/R142b, R22/R152a, R22/R152a/R124 as alternatives for R12 and R32/R134a for R22. Thermodynamic properties of these refrigerants were estimated using modified CSD equation of state. Cycle simulations of the refrigerating system considering heat source were carried out in order to compare the performance of the system. R134a shows relatively lower COP than R12 but very similar VCR. R22/R142b(50/50 mass fraction), R22/R152a(10/90), R22/R152a/R124(30/25/45) are good for the substitutes of R12 and R32/R134a(30/70) is appropriate for that of R22 in view of COP and VCR.

  • PDF

대체냉매를 사용한 로타리 압축기의 마모시험 (Wear Test for Rotary Compressor using Alternative Refrigerants)

  • 좌성훈;백충국;장선태;오상경
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1995년도 제22회 학술대회
    • /
    • pp.28-37
    • /
    • 1995
  • To protect the ozone layer depeletion the CFC (chlorofluorocarbon). HCFC(hydrochlorofluorocarbon) refrigerants will be replaced with HFCs (hydro-fluorocarbon) as an alternative refrigerant. In recent years a good deal of effort has been made to develop new compressors which are compatible to the new referigent. This paper focused on developing accelerated screening test for predicting tribological characteristics of the rotary compressor in atmosphere of R407C as an alternative refrigerant with polyolester lubricant. Falex wear test machine with high pressure chamber has been used to simulate friction and wear behavior of the common contact geometries found in rotary compressors.

  • PDF

R-12, R-134a 및 R-22를 사용한 무급유식 스크롤압축기의 성능 비교 (A Performance Comparison of Oil-free Scroll Compressors with R-12, R-134a and R-22)

  • 박희용;박경우;박용일
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.306-317
    • /
    • 1993
  • In this study, a performance comparison of scroll compressor for various refrigerants(CFC-12, HCFC-22 and HFC-134a) has been numerically carried out. The thermodynamic properties have been calculated by using the recent experimental equations and the performance has been investigated qualitatively at the same geometric specifications and operating conditions of scroll compressor. The results are as follows; HFC-134a has the highest compression ratio of 5.40. The mass flow rate of HCFC-22, which affects the cooling capacity of refrigerant system, is higher than that of other refrigerants. HFC-134a has the highest adiabatic efficiency in comparison with CFC-12 and HCFC-22.

  • PDF

대체냉매(HFC134a, HC600a)용 밀폐형 왕복동 압축기의 성능해석에 관한 연구 (Performance analysis of a hermetic reciprocating compressor using the alternative refrigerants, HFC134a and HC600a)

  • 김정우
    • 대한기계학회논문집B
    • /
    • 제22권7호
    • /
    • pp.966-979
    • /
    • 1998
  • Thermodynamic and dynamic analysis has been conducted to investigate performance variations induced by substitution of alternative refrigerants, HFC134a or HC600a for CFC12 in hermetic reciprocating compressors. For the thermodynamic analysis, mass and energy conservation laws are applied to the cylinder volume and Helmholtz resonator modeling method is adopted to describe gas pulsations at suction and discharge system. The modeling of the dynamics of the compressor mechanism has been performed with lumped mass method to analyse the bearing loads and friction losses at each bearing. To verify the correctness of this analysis, results of the performance simulation have been compared to those of calorimetric measurrements of compressor operating with CFC12. Analysis of the various losses, noise and reliability as well as performance has been conducted to present the design guideline for the compressor development with alternative refrigerants. It is found that compressors with alternative refrigerants, HFC 134a or HC600a give better COPs than those with CFC12 under the same operating conditions and especially, compressors with HC600a show better reliability and noise characteristics also.

신냉매용 자동차 에어콘 시스템에서의 건조기 설계에 관한 연구(온도감응식 팽창밸브의 개도에 따른) (Optimum Design Scheme of Receiver Dryer in an Automotive Air-Conditioning System using HFC-134a Refrigerant)

  • 송유호;김령훈;송영길
    • 한국자동차공학회논문집
    • /
    • 제4권6호
    • /
    • pp.187-195
    • /
    • 1996
  • Because an alternative refrigerant(HFC-134a) is being used instead of CFC-12 for automotive air-conditioning system, newly designed air-conditioning components are necessary due to changes in characteristics. Optimum design scheme for receiver dryer in an automotive air-conditioning system is described with emphases upon the volume of desiccant and container. The volume of the container, that is manufactured based on the study, is reduced down to one half of the existing receiver dryers.

  • PDF

자동차 에어컨용 냉매인 HFC-134a와 OS-12a의 성능 특성에 관한 연구 (A Study on Characteristics of HFC-l34a and OS-l2a Refrigerant in Automobile Air-Conditioning System)

  • 이종인;하옥남
    • 한국자동차공학회논문집
    • /
    • 제10권3호
    • /
    • pp.136-142
    • /
    • 2002
  • HFC-134a is currently used as the refrigerant in automobile air-conditioner, replacing the ozone depleting refrigerant CFC-12. Although HFC-l34a has no ozone depletion potential, it has a relatively high global warming potential, approximately 1300 tins that of CO$_2$ over a 100 year time horizon. Therefore, HFC- l34a does not seem to be a perfect alternative refrigerant due to high GWP. For this reason, non-azeotrope refrigerant mixture have been proposed as a long-term and drop-in alternative to HFC-l34a in the automobile air-conditioning system which has variable operating conditions with changes in RPM and pressure ratio. In this study,OS-l2a of which thermodynamic properties are similar to those of HFC-l34a is selected among the mixed refrigerant. HFC-l34a and OS-l2a are examined experimently by the performance test in the same automobile air-conditioning system.

실차를 이용한 자동차 에어컨 냉매 누출량 평가 (Measurement of R-134a Leakage from Vehicle Equipped Mobile Air Conditioning(MAC) System)

  • 김지영;서충열;이상은;김정수
    • 한국기후변화학회지
    • /
    • 제3권2호
    • /
    • pp.153-159
    • /
    • 2012
  • 자동차 에어컨 냉매로 사용되어온 CFC-12는 1991년부터 1994년에 걸쳐 HFC 계열의 냉매인 R134a로 대체되었으며, R-134a는 현재자동차 에어컨 냉매로 널리 사용되고 있다. 그러나 R-134a는 지구온난화 지수(GWP)가 1,300으로 매우 높으며, 교토의정서에서 정한 6대 온실가스 중에 하나로 포함되어 누출량 관리 및 대체 냉매 개발이 필요한 실정이다. 본 연구에서는 자동차에서 배출되는 $non-CO_2$ 온실가스 배출량 산출을 위한 기초연구로 실차 상태에서의 에어컨 냉매 누출량을 분석하기 위하여 가변온도밀폐실(VT shed)과 Running loss test shed를 이용하여 R-134a의 농도변화를 측정하였다. 대상차종에 대한 주차상태에서 R-134a 누출량을 분석한 결과, 연간 누출량이 6.46~13.28 g/yr 수준으로 기존의 에어컨 시스템을 이용한 누출량 분석결과와 유사한 수준으로 분석되었다. 동일 모델 차량에 단일증발기를 적용한 차량과 이중증발기를 적용한 차량에 대해 냉매 누출량을 비교한 결과, 단일증발기로 구성된 에어컨이 적용된 차량에 비하여 이중증발기가 적용된 에어컨이 장착된 차량에서 누출량이 높게 나타났다. 이는 이중증발기 적용에 따라 에어컨 시스템 구성시 연결부위(호스, 접합부 등)가 추가되면서 해당 부위에서의 누출이 증가된 것으로 보인다. 또한, 차속별 R-134a 농도변화를 분석한 결과, 고속주행시(100 km/hr) 냉매 누출이 증가하였으며, 송풍량 증가에 따른 누출량 변화는 나타나지 않았다.