• Title/Summary/Keyword: CFC

Search Result 271, Processing Time 0.033 seconds

A Study on the Decomposition Characteristics of CFC-113 by Activated Carbon (활성탄 촉매를 이용한 CFC-113의 분해특성에 관한 연구)

  • 이우근;정주영;김진범
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.4
    • /
    • pp.319-325
    • /
    • 1997
  • The catalytic decomposition of CFC-113(1,1,2-trichloro-1,2,2-trifluoroethane) was studied over an activated carbon catalyst in a fixed-bed reactor at the temperature from 300 to 600$^\circ$C, the space velocity (SV) of 1800 $\sim 14400h^{-1}$ and the mole ratio(decomposition agent/CFC-113) of 0.25 $\sim$ 5. In the absence of a decomposition agent, the decomposition efficiency of CFC-113 was low but when a decomposition agent was added to the gas stream, it was dramatically increased with the increase of temperature. In particular, in the presence of n-hexane as the decomposition agent it showed a high decomposition efficiency compared with benzene at 400$^\circ$C. It was found that the decomposition activity of CFC-113 was very sensitive to reaction temperature. Thus it is expected that to raise the reaction temperature is more effective than to increase the residence time and the amount of decomposition agent. Over the activated carbon catalyst more than 99% decomposition was achieved at the reaction temperature of 600$^\circ$C, SV of 7200$h^{-1}$, the mole ration $(C_6H_{14}/CFC-113)$ of 1 in this study.

  • PDF

Condensation heat transfer coefficients of CFC-11 and its alternative refrigerants (CFC-11과 그 대체냉매의 응축 열전달 계수)

  • Joo, Jae-Kil;Cho, Seong-Joon;Jung, Dong-Soo;Kim, Chong-Bo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.6
    • /
    • pp.830-840
    • /
    • 1997
  • In this study, condensation heat transfer coefficients(HTCs) of CFC-11, HCFC-123 and HCFC-141b are measured, which are used/or considered as working fluids in centrifugal chillers. The main objectives of this study are to measure and compare the HTCs of various refrigerants on plain and low fin tubes and also to find out the optimum fin density of the low fin tubes. To accomplish these goals, HTCs of three refrigerants are measured for the plain tube as well as 4 types of low fin tubes. All measurements are carried out at the vapor temperature of 39.deg. C with the wall temperature difference of 3 .deg. C ~ 8.deg. C. For all the refrigerants tested, a low fin tube of 28 fins per inch yielded the best performance among all the tubes tested. For the plain tube, the HTCs of CFC-11 and HCFC-141b were very similar and those of HCFC-123 were 10% lower than those of CFC-11.Thus, it can be concluded that HCFC-123 and HCFC-141b are acceptable as alternative refrigerants for CFC-11 from the view point of condensation heat transfer.

Experimental Evaluation of an Analytical Method for Chlorofluorocarbons (CFSs) in Air and Water Using Gas Chromatography (가스 크로마토그래피를 이용한 대기와 물시료의 CFCs(chlorofluorocarbons) 분석법의 실험적 평가)

  • Koh, Dong-Chan;Choi, Beom-Kyu;Kim, Yong-Je
    • Economic and Environmental Geology
    • /
    • v.40 no.1 s.182
    • /
    • pp.129-140
    • /
    • 2007
  • CFC(CFC-12, CFC-11 and CFC-113) analytical system for air and water was constructed using a customized purge and trap extraction device and a gas chromatograph with an electron capture detector. Sampling methods of air and water for CFCs were also established. The analytical system was experimentally optimized to result in reproducibilities of triplicates less than 2% for current air samples and less than 5% for groundwater samples with CFC-12 concentration of 160 to 180 pg/kg, and verified with respect to the CFC system in USGS, which showed analytical results were in agreement within 10%. CFCs in air were monitored at three sites over 19-month period in the central part of South Korea, and the result indicates no significant local sources of CFCs in those areas. For groundwater in Jeju Island, CFCs were measured over a year with a two-month interval. The time-series data showed seasonal fluctuations which could be interpreted by the effect of recharge pulse derived from large amount of rainfall during monsoon period with a few month delay, which indicates high permeability of basaltic rocks in Jeju Island.

Condensation heat transfer coefficients of alternative refrigerants for CFC11, CFC12 and HCFC22 (CFC11, CFC12, HCFC22 대체냉매의 응축 열전달계수)

  • 정동수
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.28 no.5
    • /
    • pp.389-395
    • /
    • 1999
  • 냉동공조설비, 발전설비, 화학플랜트설비 등에 사용되는 응축기는 주로 증기가 관의 외부에서 응축을 하고 냉각수가 관 내부로 흐르는 쉘-튜브(shell and tube)형 태를 취하고 있다. 초기투자비용 및 운전비용을 줄이기 위해서는 응축기의 열교환 성능을 향상시키는 일이 필수적이며 이를 위해 코팅 표면(coated surfaces), 거친 표면(rough surfaces), 코일 튜브(coiled tubes), 선회 흐름장치(swirl flow), 전열면적을 넓힌 낮은 핀관과 3차원 형상을 갖는 열전달 촉진관의 사용이 제시되고 있다.

  • PDF

Decomposition of CFC-12($CCl_2F_2$) by Discharge Plasma (방전 플라스마에 의한 CFC-12($CCl_2F_2$)의 분해)

  • 강현춘;우인성;황명환;안형환;이한섭;조정국;강안수
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.93-100
    • /
    • 1999
  • Decomposition efficiency, power consumption, and applied voltage of CFC(Chlorofluorocatbon) were investigated by SPCP(surface induced discharge plasma chemical processing) reactor to obtain optimum process variables and maximum decomposition efficiencies. Decomposition efficiency of CFC-12 with various electric frequencies(5~50kHz). flow rates (100~1,000mL/min), initial concentrations(100~1,000ppm), electrode materials(W, Cu, Al). electrode thickness(1, 2, 3mm) and reference gases($N_2$, $O_2$, air) were measured and the products were analyzed with FT-IR. Experimental results showed that at the frequency of 10kHz, the highest decomposition efficiency of 92.7% for CFC-12 were observed at the power consumptions of 29.6W. respectively, and that decomposition efficiency decreased with increasing frequency above 20kHz and decomposition efficiency per unit power were 3.13%/W for CFC-12. Decomposition efficiency was increased with increasing residence times and with decreasing initial concentration of pollutants. Decomposition efficiency was increased with increasing thickness of discharge electrode and the highest decomposition efficiency was obtained for the electrode diameter of 3m. As the electrode material, decomposition efficiency was in order that tungsten(W), copper(Cu), aluminum (Al). Decomposition of CFC-12 in the reference gas of $N_2$ showed the highest efficiency among three reference gases, and then the effect of reference gas on the decomposition efficiency decreased in order of air and $O_2$. The optimum power for the maximum decomposition efficiency was 25.3W for CFC.

  • PDF

A Case of Cardiofaciocutaneous Syndrome caused by BRAF gene mutation (BRAF 유전자의 돌연변이로 진단된 Cardiofaciocutaneous 증후군 1례)

  • Lee, Beom-Hee;Kim, Jae-Min;Lee, Jin-Joo;Kim, Gu-Hwan;Yoo, Han-Wook
    • Journal of Genetic Medicine
    • /
    • v.6 no.1
    • /
    • pp.87-90
    • /
    • 2009
  • Cardiofaciocutaneous (CFC) syndrome is characterized by dysmorphic features, cardiac anomalies, and cutaneous abnormalities. CFC syndrome belongs to the class of Noonan-related diseases. CFC syndrome can be clinically differentiated from other Noonan-related diseases by the distinct craniofacial features of sparse hair, a hypoplastic supraorbital ridge, exophthalmos and nystagmus, and skin manifestations such as ichthyosis and hyperkeratosis. However, phenotypes can overlap among Noonan-related syndromes, including CFC syndrome. Recently, several genes in the RAS-MAPK pathway have been identified as disease-causing genes for Noonan-related diseases. Here, we report on a Korean girl diagnosed with CFC syndrome caused by a V-raf murine sarcoma viral oncogene homolog B1 (BRAF) gene mutation, and we discuss the phenotype-genotype heterogeneities in Noonan syndrome and Noonan-related diseases.

  • PDF

An Experimental Study of Nucleate Boiling Heat Transfer With EHD Technique in CFC-11 and HCFC-123 (Chiller용 냉매 CFC-11과 대체냉매 HCFC-123의 전기장을 사용한 핵비등 열전달 촉진에 관한 연구)

  • Kwak, T.H.;Kim, J.H.;Jung, D.S.;Kim, C.B.;Cha, T.W.;Han, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.365-379
    • /
    • 1994
  • Pool boiling experiments were carried out to study the effect of electric field on nucleate boiling heat transfer. CFC-11 and its alternative HCFC-123 were used as working fluids. Boiling on both single tube and a bundle of five tubes was investigated. Heat flux varied from 5 to $25kW/m^2$ while the applied voltage changed from 0 to 1kV. The results showed that at low heat flux where boiling was not present or very weak, electric field-induced forced convection helped increase the heat transfer coefficients of CFC-11 and HCFC-123 significantly(4-15 times increase). However, at higher heat flux, nucleate boiling of CFC-11 which is a highly dielectric fluid, was not affected significantly by the application of electric field. In contrast to CFC-11, even at high heat flux, nucleate boiling of CFC-11 which has a relatively larger electric conductivity than CFC-11, was vigorously increased up to 2-4 times. The additional power required to apply the electric field was 1-2% of the total power consumption by the heater. The increase in overall heat transfer coefficient of evaporators with HCFC -123 was about 40%, suggesting a considerable reduction in evaporator size with EHD technique.

  • PDF

Evaluation of Ground-Water Sampling Techniques for Analysis of Chlorofluorocarbons (지하수의 CFCs(Chlorofluorocarbons) 조사를 위한 시료 채취 방법의 평가)

  • 고동찬;이대하
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.2
    • /
    • pp.1-8
    • /
    • 2003
  • Two types of ground-water sampling techniques for CFCs (chlorofluorocarbons) analysis, the cold-welded copper tube method and flame-sealed borosilicate glass ampule method, were compared and evaluated. CFCs concentrations by the copper tube method showed a poor reproducibility among triplicates whereas those by the glass ampule method showed a good agreement and relative standard deviations of triplicates were less than 5%. The poor reproducibility of the copper tube method appears to be attributed to the incomplete sealing in connection between faucets of wellhead and the sampling apparatus. The copper tube method also showed higher CFCs concentrations than the glass ampule method, which is more pronounced for CFC-11 than for CFC-12. The plastic tubings and rubber gasket of faucets in case of the copper tube method possibly contaminated the samples with CFC-11 and CFC-12. The potential of CFCs contamination for the glass ampule method was eliminated by using stainless steel and Nylon only and by connecting the sampling equipment directly to the main discharge pipe of wellhead. The validity of the glass ampule method were also verified by detecting very low level of CFCs for the ground-water sample which is old enough to have negligible CFCs.

Comparison of Physical Properties of CFC Alternative Cleaning Solvents (CFC 대체세정제의 물성 비교)

  • Row, Kyung Ho;Lee, Youn Yong
    • Analytical Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.65-75
    • /
    • 1993
  • A number of alternative cleaning solvents to CFC 113 which was identified as a ozone-depleting meterial were collected to measure their experimental physecal properties of density, surface tension, Refractive Index, boiling point, pH, viscosity, flash point, and soltbility. They might be classified as aqueous, simi-aqeous, alcohol ketone, and halogen cleaning solvents. The solubilities of abietic acid, a major component of flux used in PCB (Printed Circuit Board) of the electronic indystry, into the cleaning solvents including CFC 113 were determined for comparison. The assorted cleaning solvents have their own advantages and disadvantages. Therefore a end-user carefully needs to choose the best-fit cleaning solvent after the safety, stability, and economics as well as the effectiveness by physical properties of the alternative cleaning solvents are integratedly considered.

  • PDF

Synchrotron X-ray Powder Diffraction Study of CFC-13 Loaded Zeolite LSX (제올라이트 LSX에서의 CFC-13 분자체 흡착에 관한 결정학적 연구)

  • Lee, Yong-Jae;Lee, Jong-Won;Yoon, Ji-Ho
    • Journal of the Mineralogical Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.307-312
    • /
    • 2008
  • Rietveld analysis using synchrotron X-ray powder diffraction data collected at 15 K reveals that CFC-13 ($CF_{3}Cl;$ chlorotrifluoromethane) sorbed on Na,K-LSX binds through fluorine to sodium ions around the single 6-ring aperture in the supcrgage.