• 제목/요약/키워드: CD size

검색결과 557건 처리시간 0.03초

포지션 인덱스 작성을 위한 상·하부 시야의 불쾌글레어감 비교 (A Comparative Study on Discomfort Glare Sensation in Entire Visual Field for Position Index)

  • 김원우;박성률;김정태
    • KIEAE Journal
    • /
    • 제7권6호
    • /
    • pp.37-43
    • /
    • 2007
  • Discomfort glare is an important factor influencing appraisal for lighting environment. Unified Glare Rating (UGR) which has been proposed by CIE is one of the formula for evaluating discomfort glare. Position index is an important factor in the UGR formula. Position index was proposed by Guth in 1949. It has been used until present limiting upper visual field. Lower visual field has different sensation of brightness in comparing with upper visual field. Therefore, it is necessary to propose position index about lower visual field. The objective of this study is to investigate the brightness sensation in upper and lower visual field. First, the visual field was measured on the self-made Glare Tester. Second, luminance of the Borderline between Comfort and Discomfort (BCD) was measured on the glare Tester. Circular sources of brightness were located at various angular distances from the line of vision along five meridians, $0^{\circ}$, $45{\circ}$, $90{\circ}$, $-45{\circ}$, $-90{\circ}$. The size of the glare source is 0.0011sr. The luminance of the surrounding field, which extended over the entire visual field, was maintained $34ccd/m^2$. Ten subjects aged from 25 to 29 were participated in the experiment. The results show that the luminance of BCD on the line of vision is $4337cd/m^2$ and the glare sensation of the lower visual field is more sensitive than the upper visual field.

성장온도에 따른 Cu(In1Ga)Se2박막 태양전지의 광전특성 분석 (Photovoltaic Properties of Cu(In1Ga)Se2Thin film Solar Cells Depending on Growth Temperature)

  • 김석기;이정철;강기환;윤경훈;송진수;박이준;한상옥
    • 한국전기전자재료학회논문지
    • /
    • 제16권2호
    • /
    • pp.102-107
    • /
    • 2003
  • This study puts focus on the optimization of growth temperature of CIGS absorber layer which affects severely the performance of solar cells. The CIGS absorber layers were prepared by three-stage co-evaporation of metal elements in the order of In-Ga-Se. The effect of the growth temperature of 1st stage was found not to be so important, and 350$^{\circ}C$ to be the lowest optimum temperature. In the case of growth temperature at 2nd/3rd stage, the optimum temperature was revealed to be 550$^{\circ}C$. The XRD results of CIGS films showed a strong (112) preferred orientation and the Raman spectra of CIGS films showed only the Al mode peak at 173cm$\^$-1/. Scanning electron microscopy results revealed very small grains at 2nd/3rd stage growth temperature of 480$^{\circ}C$. At higher temperatures, the grain size increased together with a reduction in the number of the voids. The optimization of experimental parameters above mentioned, through the repeated fabrication and characterization of unit layers and devices, led to the highest conversion efficiency of 15.4% from CIGS-based thin film solar cell with a structure of Al/ZnO/CdS/CIGS/Mo/glass.

Ka 대역 위성통신 및 BWLL 시스템용 3단 MMIC 저잡음 증폭기 설계 및 제작 (A 3 Stage MMIC Low Noise Amplifier for the Ka Band Satellite Communications and BWLL System)

  • 염인복;정진철;이성팔
    • 한국전자파학회논문지
    • /
    • 제12권1호
    • /
    • pp.71-76
    • /
    • 2001
  • Ka 대역 위성통신 및 BWLL 시스템용 3단 저잡음 증폭기가 MMIC 기술로 설계 및 제작되었다. MMIC 저잡음 증폭기는 잡음지수와 높은 이득 그리고 진폭 선형성을 만족하기 위하여 2단의 single-ended 형태의 증폭단과 1단의 balanced 형태의 증폭단으로 구성되었다. 낮은 잡음지수와 높은 이득을 얻기 위하여 0.15$\mu\textrm{m}$ pHEMT 소자가 사용되었다. CD에서 80 GHz 대역까지의 안정도 확보를 위하여 직렬 및 병렬 궤환 회로와 λ/4 short 라인이 삽입되었다. 설계된 MMIC 저잡음 증폭기의 크기는 3.1mm $\times$2.4mm(7.44mm$^2$)이다. 제작된 MMIC 저잡음 증폭기의 wafer 상에서의 측정 결과, 22~ 30 GHz 주파수 대역에서 잡음지수는 2.0 dB이하이고 이득은 26dB이상으로 설계 결과와 일치하였다.

  • PDF

내시경 초음파 유도하에 세침흡인 세포검사로 진단한 위의 위장관 기질 종앙 1예 보고 (Endoscopic Ultrasound-Guided Fine Needle Aspiration Cytology in the Diagnosis of a Gastrointestinal Stromal Tumor of the Stomach -A Case Report -)

  • 김루시아;김형길;주영채;박인서;최석진;한지영;김선희;이돈행;김준미
    • 대한세포병리학회지
    • /
    • 제19권2호
    • /
    • pp.178-182
    • /
    • 2008
  • We report here a case of a gastrointestinal stromal tumor (GIST) in the stomach that was diagnosed by endoscopic ultrasound-guided fine needle aspiration cytology (EUS-FNA). A 67 year old male patient underwent regular check-ups for five years due to the presence of a submucosal tumor that was found in the fundus of the stomach incidentally. EUS-FNA was performed to evaluate the tumor, which had increased in size from 1 cm to 2.8cm. A cytologic smear revealed cohesive sheets or clusters of spindle cells with elongated nuclei. Immunohistochemical staining revealed a strong positive reaction for c-kit and CD34, without any reaction for smooth muscle actin and Ki-67. Therefore, a diagnosis of GIST was made.

어닐링 조건이 RF Magnetron sputtering을 이용하여 증착된 undoped ZnO 박막의 결정 및 광학특성에 미치는 영향 (The effect of annealing conditions on the structural and optical properties of undoped ZnO thin films prepared by RF Magnetron sputtering)

  • 박형식;유정열;윤의중
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.423-423
    • /
    • 2007
  • In this study, the effects of annealing conditions on the structural and optical properties of ZnO films were investigated. ZnO oxide (ZnO) films were deposited onto $SiO_2$/Si substrates by RF magnetron sputtering from a ZnO target. The substrate was not heated during deposition. ZnO films were annealed in temperature ranges of $500{\sim}650^{\circ}C$ in the $O_2$ flow for 5 ~ 20 min. The film average thicknesses were in the range of 291 nm. The surface morphologies and structures of the samples were characterized by SEM and XRD, respectively. The optical properties were evaluated by PL measurement at room temperature using a He-Cd 325 nm laser. According to the results, the optimal annealing conditions for the best photoluminescence (PL) characteristics were found to be oxygen fraction, ($O_2/O_2+Ar$) of 20%, RF power of 240W, substrate temperature of RT (room temperature), annealing condition of $600^{\circ}C$ for 20 min, and sputtering pressure of 20 mTorr. The obtained wavelength of light emission was found at 379 nm (ultraviolet-UV region). However, the optimal parameters for the best PL characteristics of ZnO thin films were not consistent with those obtained from the (002) intensities of XRD analyses. As a result, XRD pattern was not considered as the key issue concerning the intensity of PL of ZnO thin film. The intensity of the emitted UV light will correspond to the grain size of ZnO film.

  • PDF

Whole Genome Analysis of the Red-Crowned Crane Provides Insight into Avian Longevity

  • Lee, HyeJin;Kim, Jungeun;Weber, Jessica A.;Chung, Oksung;Cho, Yun Sung;Jho, Sungwoong;Jun, JeHoon;Kim, Hak-Min;Lim, Jeongheui;Choi, Jae-Pil;Jeon, Sungwon;Blazyte, Asta;Edwards, Jeremy S.;Paek, Woon Kee;Bhak, Jong
    • Molecules and Cells
    • /
    • 제43권1호
    • /
    • pp.86-95
    • /
    • 2020
  • The red-crowned crane (Grus japonensis) is an endangered, large-bodied crane native to East Asia. It is a traditional symbol of longevity and its long lifespan has been confirmed both in captivity and in the wild. Lifespan in birds is known to be positively correlated with body size and negatively correlated with metabolic rate, though the genetic mechanisms for the red-crowned crane's long lifespan have not previously been investigated. Using whole genome sequencing and comparative evolutionary analyses against the grey-crowned crane and other avian genomes, including the long-lived common ostrich, we identified redcrowned crane candidate genes with known associations with longevity. Among these are positively selected genes in metabolism and immunity pathways (NDUFA5, NDUFA8, NUDT12, SOD3, CTH, RPA1, PHAX, HNMT, HS2ST1, PPCDC, PSTK CD8B, GP9, IL-9R, and PTPRC). Our analyses provide genetic evidence for low metabolic rate and longevity, accompanied by possible convergent adaptation signatures among distantly related large and long-lived birds. Finally, we identified low genetic diversity in the red-crowned crane, consistent with its listing as an endangered species, and this genome should provide a useful genetic resource for future conservation studies of this rare and iconic species.

초연약지반의 매립 및 지반개량 사례 연구 (I) - 매립 (Reclamation and Soil Improvement on Ultra Soft Soil (I) - Reclamation)

  • 나영묵;홍의;한정수
    • 한국지반환경공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.23-31
    • /
    • 2005
  • 실트폰드는 크기가 55만평의 인공연못 안에 두께가 3~20m의 초연약점토가 침전되어 있었다. 1990년대 중반에 매립이 시작되었다. 매립 전 시료채취 및 다양한 종류의 원위치시험을 수행하였다. 실트폰드에 침전되어 있는 흙은 극도로 연약하기 때문에 모래 포설장비를 이용하여 모래를 전 지역에 균등하게 살포하였다. 대단히 주의 깊은 시공에도 불구하고 모래 포설시 대규모 전단파괴가 발생하였다. 따라서 파괴지역에 보강을 위하여 가로가 900m이고 세로가 700m인 고강도 보강매트를 포설한 후 재차 모래를 포설하여 매립을 완료하였다. 매립의 성공은 수중 콘관입시험으로 확인하였다.

  • PDF

고상법으로 합성한 Sr4-(x+y+z)Al14O25 : Eux, Dyy, Agz계 축광성 형광체 장잔광의 연구 (Research on Afterglow Brightness of Sr4-(x+y+z)Al14O25 : Eux, Dyy, Agz by Solid State Synthesis)

  • 김승우;김정식
    • 대한금속재료학회지
    • /
    • 제49권4호
    • /
    • pp.348-354
    • /
    • 2011
  • Long-lasting brightness $Sr_{4}Al_{14}O_{25}$ : $Eu^{2+}$, $Dy^{3+}$, $Ag^{+}$ phosphor was synthesized by modified solid state reaction and its photoluminescence was investigated. $Sr(NO_3)_{2}$ and $Al(NO_3)_3{\cdot}9H_{2}O$ as starting materials, and $B_{2}O_{3}$ as a flux were mixed with $Eu_{2}O_{3}$ as an activator, $Dy_{2}O_{3}$ as a coactivator, and $AgNO_{3}$ as a charge compensator. The crystalline of target powder showed a single-phase $Sr_{4}Al_{14}O_{25}$ by the XRD characterization and the average particle size was about 20-30 ${\mu}m$ from the FE-SEM observation. $Ag^{+}$ ion doping effects (0-0.06 mol) on $Sr_{4}Al_{14}O_{25}:Eu^{2+},\;Dy^{3+},\;Ag^{+}$ phosphor were measured by photoluminescence spectrometer and luminescence meter. The of photoluminescence intensity of the $Sr_{3.64}Al_{14}O_{25}:Eu_{0.11},\;Dy_{0.22},\;Ag_{0.03}$ phosphor was higher than other compositions and afterglow brightness was 0.186 $cd/m^{2}$.

Evaluation of 20(S)-ginsenoside Rg3 loaded hydrogel for the treatment of perianal ulcer in a rat model

  • Jin, Longhai;Liu, Jinping;Wang, Shu;Zhao, Linxian;Li, Jiannan
    • Journal of Ginseng Research
    • /
    • 제46권6호
    • /
    • pp.771-779
    • /
    • 2022
  • Background: As a kind of common complication of the surgery of perianal diseases, perianal ulcer is known as a nuisance. This study aims to develop a kind of 20(S)-ginsenoside Rg3 (Rg3)-loaded hydrogel to treat perianal ulcers in a rat model. Methods: The copolymers PLGA1600-PEG1000-PLGA1600 were synthesized by ring-opening polymerization process and Rg3-loaded hydrogel was then developed. The perianal ulcer rat model was established to analyze the treatment efficacy of Rg3-loaded hydrogel for ulceration healing for 15 days. The animals were divided into control group, hydrogel group, free Rg3 group, Rg3-loaded hydrogel group, and Lidocaine Gel® group. The residual wound area rate was calculated and the blood concentrations of interleukin-1 (IL-1), interleukin-6 (IL-6), and vascular endothelial growth factor (VEGF) were recorded. Hematoxylin and eosin (H&E) staining, Masson's Trichrome (MT) staining, and tumor necrosis factor α (TNF-α), Ki-67, CD31, ERK1/2, and NF-κB immunohistochemical staining were performed. Results: The biodegradable and biocompatible hydrogel carries a homogenous interactive porous structure with 10 ㎛ pore size and five weeks in vivo degradation time. The loaded Rg3 can be released sustainably. The in vitro cytotoxicity study showed that the hydrogel had no effect on survival rate of murine skin fibroblasts L929. The Rg3-loaded hydrogel can facilitate perianal ulcer healing by inhibiting local and systematic inflammatory responses, swelling the proliferation of nuclear cells, collagen deposition, and vascularization, and activating ERK signal pathway. Conclusion: The Rg3-loaded hydrogel shows the best treatment efficacy of perianal ulcer and may be a candidate for perianal ulcer treatment.

고-액 분리법을 이용한 LCC 도가니에서의 카드뮴 회수에 관한 연구 (A Study of Cadmium Recovery from LCC Crucible Using Solid-liquid Separation Method)

  • 박대엽;김택진;김지용;김경량;김시형;심준보;백승우;안도희
    • 공학기술논문지
    • /
    • 제4권4호
    • /
    • pp.431-436
    • /
    • 2011
  • This study was carried out to reduce the problem during distillation process, which separate U, TRU (TRans Uranium) metal electro deposit, Cd and LiCl-KCl eutectic salt generating from LCC (Liquid Cadmium Cathode) electro winning process. The cadmium recovering apparatus was manufactured to separate for each metal using solid-liquid separation method. The apparatus consists of the first sieve for the separation of U and TRU metal electrodeposit, the second sieve for the separation of LiCl-KCl eutectic salt, cadmium collection basket, and a heating furnace. In addition, the size of each sieve is 2 mm to 3 mm. In this experiment, a metal wire was employed to replace TRU metal electrodeposit and U, which exist actually in a LCC crucible. In the solid state, The LiCl-KCl is separated at 340℃ at which the solid and the liquid of the remaining cadmium and LiCl-KCl eutectic salt coexists in each, after the metal wire separated at 500℃. As a result, it seems that it would be beneficial to set the processing condition in the distillation process with the additional treatment process of cadmium and LiCl-KCl eutectic salt.