• Title/Summary/Keyword: CCTV-10

Search Result 788, Processing Time 0.032 seconds

Research on the Necessity and Measures for Protecting Local Storage Data of Homecam Devices

  • Ga. Hyeon. LEE;Hoon. Jae. Lee
    • International journal of advanced smart convergence
    • /
    • v.13 no.3
    • /
    • pp.13-17
    • /
    • 2024
  • The local storage method for home cameras, which relies on inserting an SD card into the device to store data, offers a convenient and cost-effective solution, as there are no recurring expenses after purchasing the SD card. However, we recognize that this method comes with significant security challenges. In particular, the ease with which third parties can access the SD card makes it vulnerable to both physical and software tampering. As the acceptance rate of home camera footage as evidence in courts has increased, we have become increasingly aware of the critical nature of these security issues. Digital data from home cameras, unlike other types of physical evidence, can be more easily tampered with and altered. To ensure that such data is recognized as valid legal evidence, we must prove its integrity and demonstrate that it has not been tampered with. In response to these challenges, we are committed to strengthening the security measures for both the home camera device and its local storage. By doing so, we aim to ensure the integrity and reliability of the data, thereby enhancing the overall security and trustworthiness of home camera systems.

Athermalized Design of Compact Optical System for Phone Camera (폰 카메라용 초소형 광학계의 온도보정 설계)

  • Park, Sung-Chan;You, Byoung-Taek;Lee, Jong-Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.3
    • /
    • pp.148-155
    • /
    • 2009
  • In this paper, we analysed what effect the design variables, such as refractive index, central thickness and radius of curvature, had on the first order properties and image quality of optical systems when temperature changed. The optical parameters were varied at each temperature, then the coupling and ruler methods were used to design an athermalized lens for a phone camera. This concept was first used to design the lens for a 1/3.2" 5M phone camera. The designed lens satisfies all the specifications for a phone camera, and the variations of the back focal length(${\Delta}BFL$) are reduced to $10{\mu}m$ for a temperature range of $-10^{\circ}C$ to $+60^{\circ}C$. Also, the TTL of 5.5 mm results in a compact system. All design concepts and results discussed in this paper are expected to be useful in development for the phone and CCTV camera.

Local Dehazing Method using a Haziness Degree Evaluator (흐릿함 농도 평가기를 이용한 국부적 안개 제거 방법)

  • Lee, Seungmin;Kang, Bongsoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.10
    • /
    • pp.1477-1482
    • /
    • 2022
  • Haze is a local weather phenomenon in which very small droplets float in the atmosphere, and the amount and characteristics of haze may vary depending on the region. In particular, these haze reduce visibility, which can cause air traffic interference and vehicle traffic accidents, and degrade the quality of security CCTVs and so on. Therefore, in the past 10 years, research on haze removal has been actively conducted to reduce damage caused by haze. In this study, local haze removal is performed by weight generation using a haziness degree evaluator to adaptively respond to haze-free, homogeneous haze, and non-homogeneous haze cases. And the proposed method improves the limitations of the existing static haze removal method, which assumes that there is haze in the input image and removes the haze. We also demonstrate the superiority of the proposed method through quantitative and qualitative performance evaluations with benchmark algorithms.

Effect of Imipramine on the Contractility of Single Cells Isolated from Canine Detrusor (Imipramine이 배뇨근 세포의 수축성에 미치는 직접작용)

  • Huh, Chan-Wook;Lee, Kwang-Youn;Kim, Won-Joon
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.2
    • /
    • pp.293-302
    • /
    • 1994
  • The objective of this study was to establish a good methodology to isolate single smooth muscle cells that are alive and respond properly to pharmacological agents. Canine urinary bladders were employed as the source of single cells, and acetylcholine, atropine and imipramine were used as indicators of pharmacological responsiveness. Imipramine, an antidepressant drug exhibited the anticholinergic and calcium antagonizing properties on rat detrusor muscle. To establish a control value for a further experiment to elucidate the mechanism of action of imipramine on detrusor muscle, we measured the concentration-response of single cells to acetylcholine in the presesnce of imipramine by length of the cells and compared the result with the response in the presence of atropine. Tiny chops of smooth muscle taken from anesthetized canine urinary bladder were incubated in collagenase solution at $36^{\circ}C$ for 17-20 minutes. The collagenase solution included collagenase 1.2 mg/ml, soybean tryspin inhibitor 0.08 mg/ml, bovine serum albumin 2% in 10 ml Krebs-Henseleit buffer solution aerated with a consistent breeze of 95/5% $O_2/CO_2$, to maintain the pH at 7.4. After washing with plain K-H solution on 450 mesh, cells were dissociated from the digested tissue for 12-15 minutes. Cell suspension was transfered in 5 ml test tubes and acetylcholine was added for the final concentration to be $10^{-14}M{\sim}10^{-9}M$. To find the optimal time to fix the cells to determine the contractile responses, 1% acrolein was added 5, 10, 20, 30, 60 and 120 seconds after the administration of ACh. The length of cells fixed by acrolein were measured by microscaler via CCTV camera on phaes-contrast microscope. The average length of 50 cells from a slide glass was taken as the value of a sample at the very concentration point. Single cells were isolated from canine detrusor. The length of untreated cells varied from 82 ${\mu}m$ to 94 ${\mu}m$. The maximal response to actylcholine $10^{-9}M$ was accomplished within 5 seconds of exposure, and the shortening was $19{\pm}3$%. Atropine reduced the contraction of the cells concentration-dependently. Imipramine which exerts a cholinergic blocking action on some smooth muscles also reduced the contraction concentration-dependently and by a similar pattern as atropine. These findings document that imipramine may exerts a cholinergic blocking activity in the single smooth muscle cells isolated from canine urinary bladder.

  • PDF

Possibility of Information Leakage through Analysis of Chinese Antivirus Software (중국 안티바이러스 제품 분석을 통한 정보유출 가능성 연구)

  • Park, Wonhyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.10
    • /
    • pp.1369-1374
    • /
    • 2021
  • Recently, controversy has been raised over the security and safety of Chinese-made network equipment (Huawei 5G), apps (TikTok, etc.). In particular, according to the results of the Ministry of Defense investigation in 2020, malicious codes were found in CCTVs made in China that were delivered as military surveillance equipment used as a coast guard system, and specific information was remotely transmitted to a Chinese server. The safety issues of these Chinese security products can be questioned as being systematically led by the state rather than by companies or individuals. In this paper, we perform network and process level analysis of 360 Total Security(360 TS), a Chinese antivirus software. In addition, it compares and analyzes the domestic cloud-based vaccine V3 Lite product. Through this, the safety of Chinese security solutions is checked and information leakage and risks are suggested.

Train Crowdedness Analysis Model for the Seoul Metropolitan Subway : Considering Train Scheduling (열차운행계획을 반영한 수도권 도시철도 열차 혼잡도 분석모형 연구)

  • Lee, Sangjun;Yun, Seongjin;Shin, Seongil
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.3
    • /
    • pp.1-17
    • /
    • 2022
  • Accurate analysis of the causes of metro rail traffic congestion provides a means of addressing issues arising from metro rail traffic congestion in metropolitan areas. Currently, congestion analysis based on counting, weight detection, CCTVs, and mobile Wi-Fi is limited by poor accuracies or because studies have been restricted to single routes and trains. In this study, a train congestion analysis model was used that includes the transfer and multi-path behavior of metro passengers and train operation plans for metropolitan urban railroads. Analysis accuracy was improved by considering traffic patterns in which passengers must wait for next trains due to overcrowding. The model updates train crowding levels every 10 minutes, provides information to potential passengers, and thus, is expected to increase the social benefits provided by the Seoul metropolitan subway

The development of buoy type fish finder using LTE communication (LTE 통신을 이용한 부표형 어군탐지기 개발)

  • KANG, Tae-Jong;MIN, Eun-Bi;HEO, Gyeom;SHIN, Hyeon-Ok;HWANG, Doo-Jin
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.2
    • /
    • pp.141-152
    • /
    • 2022
  • As a method to understand the ecological habits around the artificial reef, various reports such as fishing gear survey, diving, sound survey, underwater CCTV and camera, etc. are reported. Among them, the sound survey method is carried out by installing an acoustic system on the ship and can be investigated regardless of the marine environment such as time constraints and turbidity. Such method, however, takes a lot of manpower and time as the ship travels at a constant speed. Investigations around artificial reefs are being conducted in an artificial way, and a lot of time and labor are consumed as such. Maritime buoys have been operated for various purposes such as route signs, weather observation, marine environment monitoring and defense monitoring for navigation safety in the past, but studies on monitoring systems for ecological habits and distribution of fish using marine buoys are remarkably insufficient. Therefore, this study aims to develop a system that allows users to directly monitor fish group detector data by estimating the distribution of fish groups around artificial reefs and using wireless communication at sea. In order to confirm the suitability of the maritime buoy used in this study, it was operated to compare data using LTE-equipped buoys capable of wireless communication and a data logger-type system buoy. Data transmission of buoys capable of LTE communication was carried out in a 10-minute ON, 10-minute OFF method due to the limitation of the power supply capacity, and data of the data logger-type buoy received full data. We compared and analyzed the data received from the two fish detectors. It is expected that real-time monitoring of the wireless buoy detection device using LTE will be possible through future research.

Exploring Spatial Patterns of Theft Crimes Using Geographically Weighted Regression

  • Yoo, Youngwoo;Baek, Taekyung;Kim, Jinsoo;Park, Soyoung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.1
    • /
    • pp.31-39
    • /
    • 2017
  • The goal of this study was to efficiently analyze the relationships of the number of thefts with related factors, considering the spatial patterns of theft crimes. Theft crime data for a 5-year period (2009-2013) were collected from Haeundae Police Station. A logarithmic transformation was performed to ensure an effective statistical analysis and the number of theft crimes was used as the dependent variable. Related factors were selected through a literature review and divided into social, environmental, and defensive factors. Seven factors, were selected as independent variables: the numbers of foreigners, aged persons, single households, companies, entertainment venues, community security centers, and CCTV (Closed-Circuit Television) systems. OLS (Ordinary Least Squares) and GWR (Geographically Weighted Regression) were used to analyze the relationship between the dependent variable and independent variables. In the GWR results, each independent variable had regression coefficients that differed by location over the study area. The GWR model calculated local values for, and could explain the relationships between, variables more efficiently than the OLS model. Additionally, the adjusted R square value of the GWR model was 10% higher than that of the OLS model, and the GWR model produced a AICc (Corrected Akaike Information Criterion) value that was lower by 230, as well as lower Moran's I values. From these results, it was concluded that the GWR model was more robust in explaining the relationship between the number of thefts and the factors related to theft crime.

A Study on Object Detection Algorithm for Abandoned and Removed Objects for Real-time Intelligent Surveillance System (실시간 지능형 감시 시스템을 위한 방치, 제거된 객체 검출에 관한 연구)

  • Jeon, Ji-Hye;Park, Jong-Hwa;Jeong, Cheol-Jun;Kang, In-Goo;An, Tae-Ki;Park, Goo-Man
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1C
    • /
    • pp.24-32
    • /
    • 2010
  • In this paper we proposed an object tracking system that detects the abandoned and removed objects, which is to be used in the intelligent surveillance applications. After the GMM based background subtraction and by using histogram method, the static region is identified to detect abandoned and removed objects. Since the system is implemented on DSP chip, it operates in realtime and is programmable. The input videos used in the experiment contain various indoor and outdoor scenes, and they are categorized into three different complexities; low, midium and high. By 10 times of experiment, we obtained high detection ratio at low and medium complexity sequences. On the high complexity video, successful detection ratio was relatively low because the scene contains crowdedness and repeated occlusion. In the future work, these complicated situation should be solved.

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF