• 제목/요약/키워드: CCPU

검색결과 19건 처리시간 0.023초

방식층 보호장치의 설치에 따른 지중송전케이블 시스 유기전압 해석 (Analysis of Sheath Induced Voltage in Transmission Power Cable Connected with CCPU)

  • 이준성;이종범;김영
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권1호
    • /
    • pp.19-25
    • /
    • 2000
  • This paper describes the sheath induced voltage in underground transmission cable system which will be operated with cable cover protection unit(CCPU). Simulation was carried out to analyze the sheath induced voltage in the real cable system which was installed by 154㎸ CV cable in the case with and without CCPU. The sheath induced voltage will be also analyzed according to the change of grounding method, fault resistance and fault angle. Simulation was performed using EMTP and ATP Draw, the simulation results show whether the CCPU in necessary or not in underground transmission power cable system.

  • PDF

지중송전계통 절연통보호장치 모델링 기법에 관한 연구 (A Study on Modeling Methods for Cable Covering Protective Unit on Underground Power Cable Systems)

  • 최경규;장태인;윤형희;정채균
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2098-2102
    • /
    • 2007
  • The conventional CCPU(Cable Covering Protective Unit) modeling methods which are used by Type 99 and Type 92 in EMTP simulation are firstly discussed in this paper, and then some problems of them are also investigated. Modeling method using Type 99 causes unstable characteristic at initial transient of CCPU operation. Time delay has also effect on the output of CCPU modeling. So, in this paper, a new modeling method for CCPU is designed by DBM(Data Base Module) of EMTP. The characteristic of Type 92 is used for the new modeling method. The reliability of this one is proved by comparing simulation with measured data. Specially, at initial transient, the waveform of the new method shows more stable result than that of conventional method using Type 99. Also, the peak value is similar to measured data.

지중송전계통에서 시스유기전압 및 CCPU 동작 특성 해석 (Analysis of Sheath Induced Voltage and CCPU Operating Characteristic in Underground Transmission Cable)

  • 진혜영;이종범;김영;조한구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.494-496
    • /
    • 2001
  • This paper describes sheath induced voltage and operating characteristic of cable cover protection unit(CCPU) in underground transmission cable. Real cable system operating by 154kV XLPE cable was modelled for simulation. Sheath induced voltage and operating characteristic of CCPU were analyzed. In particular, sheath induced voltage was analyzed in case of individual grounding and common grounding, respectively, and operating characteristics of CCPU were compared each other.

  • PDF

지중 케이블 시스템에서 본딩방식의 혼용으로 인한 영향 (The Effect of Different Boding Methods in Under Ground Cable System)

  • 김정년;하체웅;이수길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.352-355
    • /
    • 2001
  • 국내에서 CCPU(Cable Covering Protection Unit)의 결선방식은 97년 이전에는 대지간 방식을 취하였고, 97년 이후에는 교락 비접지 방식을 채택하여 적용중이다. 따라서 국내 선로 중에 97년 이전 준공되어 97년 이후에 증설한 선로에서는 CCPU의 연결방식이 대지간 및 교락 비접지 방식이 혼용되어 사용되어 왔다. 본 논문에서는 CCPU의 결선방식이 혼용된 선로에서 문제점을 규명하고 개선안을 제시하였다.

  • PDF

방식층 보호장치 결선방식의 혼용에 따른 영향분석 (The Effects of Multi-Bonding Methods for Cable Covering Protection Unit)

  • 김정년;하체웅;이수길
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권10호
    • /
    • pp.489-492
    • /
    • 2001
  • The connection method of CCPU has been changed from connection between sheath and grounding to connection between sheaths without grounding since 1997. In domestic, there is so many cases that cables circuits were installed before 1997, added in same route after that, operated as multi-connecting systems of CCPU in same route. This paper examine the problem of multi-connecting system by EMTP simulation, and presents methods to improve the system characteristics.

  • PDF

케이블 방식층보호장치의 결선방식에 대한 고장전류해석 (A Study on Fault Current Analysis for CCPU Connection)

  • 정성환;최인혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.160-162
    • /
    • 1996
  • This paper is one-phase fault current analysis of 154kV underground transmission power cable. Its purpose is to gain knowleges of connect ing the CCPU and to show the merits as its method. There are many methods of connect ing CCPU, i.e, a conventional method, CIGRE method, interconnect ion between sheaths with grounding, and interconnect ion between sheaths without grounding. These methods will be compared in this paper.

  • PDF

혼합송전선로에서 고저항 지락사고시 케이블 과도현상 해석 및 전력케이블 시스 접지저항에 따른 CCPU 과도특성 모의 (Modeling and Transient Analysis of Cable in Combined Transmission Line with HIF and Analysis of Transient Characterstic in CCPU of Uderground Cable)

  • 정채균;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.446-448
    • /
    • 2000
  • This paper discribes the modeling and transient analysis of cable in combined transmission line under high impedance fault(HIF). And also, transient characterstic analyzed on cable covering protection unit(CCPU) is presented. Modeling of the combined transmission line is established in PSCAD/EMTDC V3. The required data to analyze the transient phenomena is given from the actual system. The results show the HIF modeling in cable, fault current according to the value of fault resistance. And also when the value and method of grounding resistance is changed in CCPU, simulation results are presented.

  • PDF

지중송전계통에서 배전선 불평형전류 유입에 따른 영향 검토 (Analysis of induced voltage of CCPU with unbalanced current from Distribution Line on Underground Transmission Cable System)

  • 강지원;장태인;홍동석;정채균;윤동수;윤종건;김형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.459-461
    • /
    • 2005
  • This paper analyses the induced voltage characteristic of CCPU with unbalanced current from distribution line on underground transmission power cable systems. In switching surge strokes, in order to obtain the data of induced voltage/current on CCPU, the actual proof test carried out. This paper is expected to contribute the establishment of proper protection methods of CCPU against the unbalanced current from distribution line on underground transmission power cable systems.

  • PDF

실 계통의 혼합송전선로에서 CCPU파괴 원인과 그 대책 (The Cause of CCPU's failure and Improved Configuration Method in Combined Transmission Lines)

  • 하체웅;김정년;이수길;허회덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.210-212
    • /
    • 2001
  • The protection of underground cables against transient overvoltages resulting from lightning and other causes is important in cable-tine which is connected with overhead line and underground cable. This paper investigates the failure of CCPU(Cable covering Protection Unit) and presents improved configuration method of CCPU in underground cable system EMTP(Electromagnetic Transient Program) is used in order to study the overvoltages and modeling of components of the system such as overhead lines, underground cables, CCPUs and towers in presented.

  • PDF

지중송전계통에서 불평형 구성요소에 따른 과도현상 해석 및 평가 (Transient Phenomena Analysis and Estimation According to Unbalance Factors on Underground Power Cable Systems)

  • 정채균;이종범;강지원;이동일
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권8호
    • /
    • pp.410-417
    • /
    • 2005
  • This paper analyses the transient phenomena against single line to ground fault and lightning surge on underground power cable systems. For analysis in various fault conditions, several actual underground power cable systems are modeled using ATP In ground fault, the transient characteristic of the conductor and the sheath according to the fault current and the installation types of CCPU are analysed. In lightning surge strokes, the various unbalanced conditions including the length of crossbonded lead, the breakdown of CCPU and distance unbalance are considered. This paper is expected to contribute the establishment of proper protection methods against transients on underground power cable systems.