• Title/Summary/Keyword: CCD linear image

Search Result 62, Processing Time 0.026 seconds

Geometric Modelling and Coordinate Transformation of Satellite-Based Linear Pushbroom-Type CCD Camera Images (선형 CCD카메라 영상의 기하학적 모델 수립 및 좌표 변환)

  • 신동석;이영란
    • Korean Journal of Remote Sensing
    • /
    • v.13 no.2
    • /
    • pp.85-98
    • /
    • 1997
  • A geometric model of pushbroom-type linear CCD camera images is proposed in this paper. At present, this type of cameras are used for obtaining almost all kinds of high-resolution optical images from satellites. The proposed geometric model includes not only a forward transformation which is much more efficient. An inverse transformation function cannot be derived analytically in a closed form because the focal point of an image varies with time. In this paper, therefore, an iterative algorithm in which a focal point os converged to a given pixel position is proposed. Although the proposed model can be applied to any pushbroom-type linear CCD camera images, the geometric model of the high-resolution multi-spectral camera on-board KITSAT-3 is used in this paper as an example. The flight model of KITSAT-3 is in development currently and it is due to be launched late 1998.

Trajectory Estimation of a Moving Object using Kohonen Networks

  • Ju, Jin-Hwa;Lee, Dong-Hui;Lee, Jae-Ho;Lee, Jang-Myung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.2033-2036
    • /
    • 2004
  • A novel approach to estimate the real time moving trajectory of an object is proposed in this paper. The object position is obtained from the image data of a CCD camera, while a state estimator predicts the linear and angular velocities of the moving object. To overcome the uncertainties and noises residing in the input data, a Kalman filter and neural networks are utilized. Since the Kalman filter needs to approximate a non-linear system into a linear model to estimate the states, there always exist errors as well as uncertainties again. To resolve this problem, the neural networks are adopted in this approach, which have high adaptability with the memory of the input-output relationship. Kohonen Network(Self-Organized Map) is selected to learn the motion trajectory since it is spatially oriented. The superiority of the proposed algorithm is demonstrated through the real experiments.

  • PDF

Evaluation of color CRT monitor by MTFA (MTFA에 의한 칼라 CRT의 화질 평가)

  • 김태희
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.3
    • /
    • pp.205-211
    • /
    • 1998
  • The MTF(modulation transfer function) measuring system with a linear CCD(charge coupled-device) was constructed to cvaluate a color CRT(catode ray tube). The measured MTF values were corrected by considering the spectral response and the pixel sizes of CCD. The effects of a spot size, video bandwidth, pitch of shadow mask holes, display luminance, and ambient illumination on image quality were studied. The uniformity of resolution and the contrast Ioss by ambient light of the color CRT monitor were measured, and the results were analyzed by MTFA(modulation threshold area).

  • PDF

A Method for Quantitative Measurement of Lateral Flow Immunoassay Using Color Camera (컬러 카메라를 이용한 측면유동 면역 어세이 정량분석 방법)

  • Park, Jongwon
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • Among semi-quantitative or fully quantitative lateral flow assay readers, an image sensor-based instrument has been widely used because of its simple setup, cheap sensor price, and compact equipment size. For all previous approaches, monochrome CCD or CMOS cameras were used for lateral flow assay imaging in which the overall intensities of all colors were taken into consideration to estimate the analyte content, although the analyte related color information is only limited to a narrow wavelength range. In the present work, we introduced a color CCD camera as a sensor and a color decomposition method to improve the sensitivity of the quantitative biosensor system which utilizes the lateral flow assay successfully. The proposed setup and image processing method were applied to achieve the quantification of imitatively dispensed particles on the surface of a porous membrane first, and the measurement result was then compared with that using a monochrome CCD. The compensation method was proposed in different illumination conditions. Eventually, the color decomposition method was introduced to the commercially available lateral flow immunochromatographic assay for the diagnosis of myocardial infarction. The measurement sensitivity utilizing the color image sensor is significantly improved since the slopes of the linear curve fit are enhanced from 0.0026 to 0.0040 and from 0.0802 to 0.1141 for myoglobin and creatine kinase (CK)-MB detection, respectively.

Constructing a Automatic Real-time Line-Scan Inspection System (실시간 자동 검사를 위한 라인 스캔 컴퓨터 비전 시스템의 연구)

  • Jang, Dong-Sik;Kim, Yong-Deok
    • IE interfaces
    • /
    • v.9 no.1
    • /
    • pp.73-82
    • /
    • 1996
  • The purpose of this research is to construct real-time image acquisition system for a line-scan inspection system as a computer vision system. To construct the line-scan inspection system, many problem arise. However, problems of image acquisitions using linear CCD are practically studied in this paper. These problems are concerned to proper lighting systems, relations with handling system, camera systems, and impacts due to the noise of environment. These problems are examined separately, and proper configurations for each case are suggested to construct the line-scan image acquisition system.

  • PDF

A Study on Non-contact Measurement of 3D-Objects by Optical Probe Method (광촉침법에 의한 비접촉 3차원 형상측정에 관한 연구)

  • Kang, Young-June;Shin, Seong-Kook;Miyoshi, Takashi
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.4
    • /
    • pp.119-126
    • /
    • 1995
  • This paper presents a non-contact measuring system using one point measuring method to measure surface profiles of dies and clay models for practical use in the field of production engineering. The system has a laser beam probe similar to a measuring probe in a contact measuring system and CCD linear sensor used to detect 300mm measurement range, displacement of measured surfaces, from an origin. There is no mechanical interference between this measuring system and a measured surface in this system. In this measuring system, it was needed 500-600ms including data processing time to measure one point. The experiments showed that the standard deviation was 800 .mu.m and the reproducibility was also 100-210 .mu. m.

  • PDF

CALOS : Camera And Laser for Odometry Sensing (CALOS : 주행계 추정을 위한 카메라와 레이저 융합)

  • Bok, Yun-Su;Hwang, Young-Bae;Kweon, In-So
    • The Journal of Korea Robotics Society
    • /
    • v.1 no.2
    • /
    • pp.180-187
    • /
    • 2006
  • This paper presents a new sensor system, CALOS, for motion estimation and 3D reconstruction. The 2D laser sensor provides accurate depth information of a plane, not the whole 3D structure. On the contrary, the CCD cameras provide the projected image of whole 3D scene, not the depth of the scene. To overcome the limitations, we combine these two types of sensors, the laser sensor and the CCD cameras. We develop a motion estimation scheme appropriate for this sensor system. In the proposed scheme, the motion between two frames is estimated by using three points among the scan data and their corresponding image points, and refined by non-linear optimization. We validate the accuracy of the proposed method by 3D reconstruction using real images. The results show that the proposed system can be a practical solution for motion estimation as well as for 3D reconstruction.

  • PDF

Moving Object Trajectory based on Kohenen Network for Efficient Navigation of Mobile Robot

  • Jin, Tae-Seok
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.2
    • /
    • pp.119-124
    • /
    • 2009
  • In this paper, we propose a novel approach to estimating the real-time moving trajectory of an object is proposed in this paper. The object's position is obtained from the image data of a CCD camera, while a state estimator predicts the linear and angular velocities of the moving object. To overcome the uncertainties and noises residing in the input data, a Extended Kalman Filter(EKF) and neural networks are utilized cooperatively. Since the EKF needs to approximate a nonlinear system into a linear model in order to estimate the states, there still exist errors as well as uncertainties. To resolve this problem, in this approach the Kohonen networks, which have a high adaptability to the memory of the input-output relationship, are utilized for the nonlinear region. In addition to this, the Kohonen network, as a sort of neural network, can effectively adapt to the dynamic variations and become robust against noises. This approach is derived from the observation that the Kohonen network is a type of self-organized map and is spatially oriented, which makes it suitable for determining the trajectories of moving objects. The superiority of the proposed algorithm compared with the EKF is demonstrated through real experiments.

Precision correction of satellite-based linear pushbroom-type CCD camera images (선형 CCD카메라 영상의 정밀 기하학적 보정)

  • 신동석;이영란;이흥규
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.2
    • /
    • pp.137-148
    • /
    • 1998
  • An algorithm developed for the precision correction of high resolution satellite images is introduced in this paper. In general, the polynomial warping algorithm which derives polynomial equations between GCPs extracted from an image and a base map requires many GCPs well-distributed over the image. The precision correction algorithm described in this paper is based on a sensor-orbit-Earth geometry, and therefore, it is capable of correcting a raw image using only 2-3 GCPs. This algorithm estimates the errors on the orbit determination and the attitude of the satellite by using a Kalman filter. This algorithm was implemented, tested and integrated into the KITSAT-3 image preprocessing software.

Investigation of Physical Imaging Properties in Various Digital Radiography Systems (다양한 디지털 방사선 시스템의 물리적 영상 특성 조사)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Yoon, Yong-Su;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.363-370
    • /
    • 2017
  • We aimed to evaluate the physical imaging properties in various digital radiography systems with charged coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spectrum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiography system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.