• Title/Summary/Keyword: CC V3.0

Search Result 77, Processing Time 0.024 seconds

Consolidation Behavior of Soft Ground by Prefabricated Vertical Drains (페이퍼드레인 공법에 의한 연약지반의 압밀거동)

  • Lee, Dal Won;Kang, Yea Mook;Kim, Seong Wan;Chee, In Taeg
    • Korean Journal of Agricultural Science
    • /
    • v.24 no.2
    • /
    • pp.145-155
    • /
    • 1997
  • The large scaled field test by prefabricated vertical drains was performed to evaluate the superiority of vertical discharge capacity for drain materials through compare and analyze the time-settlement behavior with drain spacing and the compression index and consolidation coefficient obtained by laboratory experiments and field monitoring system. 1. The relation of measurement settlement($S_m$) versus design settlement($S_t$) and measurement consolidation ratio($U_m$) versus design consolidation ratio($U_t$) were shown $S_m=(1.0{\sim}1.1)S_t$, $U_m=(1.13{\sim}1.17)U_t$ at 1.0m drain spacing and $S_m=(0.7{\sim}0.8)S_t$, $U_m=(0.92{\sim}0.99)U_t$ at l.5m drain spacing, respectively. 2. The relation of field compressing index($C_{cfield}$) and virgin compression index($V_{cclab.}$) was shown $C_{cfield}=(1.0{\sim}1.2)V_{cclab.}$, But it was nearly same value when considered the error with determination method of virgin compression index and prediction method of total settlement. 3. Field consolidation coefficient was larger than laboratory consolidation coefficient, and the consolidation coefficient ratio($C_h/C_v$) were $C_h=(2.4{\sim}3.0)C_v$. $C_h=(3.5{\sim}4.3)C_v$ at 1.0m and 1.5m drain spacing and increased with increasing of drain spacing. 4. The evaluation of vertical discharge capacity with drain spacing from the results of the consolidation coefficient ratio showed largely superior in case the Mebra drain and Amer drain than other drain materials at 1.0m and 1.5m drain spacing, while the values showed nearly same value in case same drain spacing.

  • PDF

A study on the design of the stable internal voltage system for DRAM's (DRAM의 안정한 내부 전압 시스템 설계에 관한 연구)

  • 주종두;이승훈;곽계달
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.542-545
    • /
    • 1998
  • This paper presents a new reference voltage generator(RVG) for advanced DRAM's. The proposed RVG with three temperature coefficient is independent of temperature variation, and supply voltage. This is used to shorten leakage current using the boosted sense ground(BSG). This circuit is designed in a 0.8.mu.m nwell CMOS, double-polysilicon, double-metal technology. The simulation resutls in jindependent temperature and supply voltage. In hspice simulation results, temperature dependency of RVG is 130.mu.V/.deg. C and supply voltage dependency is .+-.0.91%, $V_{cc}$ =3.3V.+-. 0.5V.3.3V.+-. 0.5V.

  • PDF

Influence of Couch and Collimator on Dose Distribution of RapidArc Treatment Planning for Prostate Cancer in Radiation Therapy (치료테이블과 콜리메이터가 전립선암 래피드아크 치료계획의 선량분포에 미치는 영향)

  • Kim, Hyung-Dong;Kim, Byung-Young;Kim, Sung-Jin;Yun, Sang-Mo;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • We investigated the influence of photon energy, couch and collimator angle differences between arcs on dose distribution of RapidArc treatment planning for prostate cancer. RapidArc plans were created for 6 MV and 10 MV photons using 2 arcs coplanar and noncoplanar fields. The collimator angle differences between two arcs were $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $75^{\circ}$ and $90^{\circ}$. The plans were optimized using same dose constrains for target and OAR (organ at risk). To evaluate the dose distribution, plans were analyzed using CI (conformity index), HI (homogeneity index), QOC (quality of coverage), etc. Photon energy, couch and collimator angle differences between arcs had a little influence on the target and OAR. The difference of dosimetric indices was less than 3.6% in the target and OAR. However, there was significant increase in the region exposed to low dose. The increase of V15% in the femur was 6.4% (left) and 5.5% (right) for the 6 MV treatment plan and 23.4% (left), 24.1% (right) for the noncoplanar plan. The increase of V10% in the Far Region distant from target was 54.2 cc for the 6 MV photon energy, 343.4 cc for the noncoplanar and 457.8 cc for the no collimator rotation between arcs.

Effects of reactant gases on phosphoric acid fuel cell performance (인산형 연료전지의 발전성능에 미치는 반응기체 영향)

  • 송락현;김창수;신동렬
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.374-379
    • /
    • 1996
  • Effects of reactant gas flow rates and starvation on phosphoric acid fuel cell performance were studied. As the reactant gas flow rates increased, the cell performance increased and then the cell maintained constant performance. The optimum flow rates of hydrogen, oxygen and air under galvanostatic condition of 150 mA/cm$_{2}$ are found to be 5cc/min cm$_{2}$ 5cc/min cm$_{2}$ and 15cc/min cm$_{2}$ at room temperature and 1 atm, respectively. Also the open circuit voltage of single cell decreased with increasing oxygen flow rate due probably to the decreased probably to the decreased oxygen pressure in the cathode side. Hydrogen and oxygen starvation resulted in voltage loss of about 5mV and 0-2mV, respectively. The voltage loss was independent of starvation time. These results were discussed from point of view of electrochemical reaction of the cell. (author). 9 refs., 8 figs.

  • PDF

Feasibility and Efficacy of Adaptive Intensity Modulated Radiotherapy Planning according to Tumor Volume Change in Early Stage Non-small Cell Lung Cancer with Stereotactic Body Radiotherapy (폐암의 정위적체부방사선치료에서 육안적종양체적 변화에 따른 적응방사선치료의 효용성 및 가능성 연구)

  • Park, Jae Won;Kang, Min Kyu;Yea, Ji Woon
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.79-86
    • /
    • 2015
  • The purpose of this study is to evaluate efficacy and feasibility of adaptive radiotherapy according to tumor volume change (TVC) in early stage non-small cell lung cancer (NSCLC) using stereotactic body radiotherapy (SBRT). Twenty-two lesions previously treated with SBRT were selected. SBRT was usually performed with a total dose of 48 Gy or 60 Gy in four fractions with an interval of three to four days between treatments. For evaluation of TVC, gross tumor volume (GTV) was contoured on each cone-beam computed tomography (CBCT) image used for image guidance. Intensity modulated radiotherapy (IMRT) planning was performed in the first CBCT (CBCT1) using a baseline plan. For ART planning (ART), re-optimization was performed at $2^{nd}$, $3^{rd}$, and $4^{th}$ CBCTs (CBCT2, CBCT3, and CBCT4) using the same angle and constraint used for the baseline plan. The ART plan was compared with the non-ART plan, which generated copying of the baseline plan to other CBCTs. Average GTV volume was 10.7 cc. Average TVC was -1.5%, 7.3%, and -25.1% in CBCT2, CBCT3, and CBCT4 and the TVC after CBCT3 was significant (p<0.05). However, the nine lesions were increased GTV in CBCT2. In the ART plan, $V_{20\;Gy}$, $D_{1500\;cc}$, and $D_{1000\;cc}$ of lung were significantly decreased (p<0.05), and $V_{30\;Gy}$ and $V_{32\;Gy}$ of the chest wall were also decreased (p<0.05). While D min of planning target volume (PTV) decreased by 8.3% in the non-ART plan of CBCT2 compared with the baseline plan in lesions with increased tumor size (p=0.021), PTV coverage was not compromised in the ART plan. Based on this result, use of the ART plan may improve target coverage and OAR saving. Thus ART using CBCT should be considered in early stage NSCLC with SBRT.

Development of Monoenergetic Photon Source in the Energe Range below 100 keV by the X-ray Fluorescence Method (형광 X 선을 이용한 100 KeV 이하의 에너지 영역에서의 단색 Photon 선원개발에 관한 연구)

  • Lee, Youn-Myoung;Lee, Kun-Jai;Hah, Suck-Ho;Hwang, Sun-Tae;Lee, Kyung-Ju
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.1
    • /
    • pp.14-28
    • /
    • 1985
  • The development of mono energetic photon sources using $K_{\alpha}$ fluorescence X-ray of pure material was carried out in the energy range below 100 keV. The monoenergetic photons are very useful in the calibration of the radiation measuring instruments and can be produced as the $K_{\alpha}$ fluorescence X-ray by irradiating the bremsstrahlung to the thin pure metal foils called ‘radiators’. In this experiment, several radiators such as $_{47}Ag,\;_{50}Sn,\;_{68}Er,\;_{70}Yb,\;and\;_{82}Pb$ provide the wide monoenergetic photon energy ranging from 20 keV to 80 keV. By the spectrometry with HpGe LEPS, spectral purity factors which measure the monochrometicity for the $K_{\alpha}$ fluorescence X-ray, were determined as $0.64{\sim}0.94$. Dosimetry for the purpose of the determination of the exposure rate with a 600cc thin window ionization chamber, which was calibrated by the standard free-air ionization chamber, was performed. Exposure rates ranging $8.3{\sim}232.5mR/h$ was obtained according to the $K_{\alpha}$ fluorescence X-ray energy for each radiator.

  • PDF

Evaluation Methods of Compression Index and the Coefficient of Consolidation by Back Analysis of Settlement Data (현장계측치로부터 역산한 압축지수와 압밀계수의 평가 방법)

  • Lee, Dal Won;Lim, Seong Hun;Kim, Ji Moon
    • Korean Journal of Agricultural Science
    • /
    • v.27 no.1
    • /
    • pp.39-47
    • /
    • 2000
  • A large scale field test of prefabricated vertical drains is performed to analyze the effect of parameters of the very soft clay at a test site. Compression index and the coefficient of horizontal consolidation obtained by back-analysis from the settlement data were compared with those obtained by means of laboratory tests. The Hyperbolic, Asaoka's and The Curve fitting methods are used to estimate final settlements and coefficients of consolidation. 1. Final settlement predicted with the Hyperbolic method was the largest, and the settlements predicted with the Asaoka's and the Curve fitting methods were nearly the same range, and it was concluded that smear effect has to be considered on design in the case that spacing of drains is small 2. The relationships of the measured consolidation ratio (Urn) and the designed consolidation ratio($U_t$) were showed as $U_m$ = (1.13~1.17)$U_t$, $U_m$ = (1.07~1.20)$U_t$, $U_m$ = (1.13~1.17)$U_t$ on the Hyperbolic, Asaoka's and the Curve fitting methods, respectively. The relations on the Asaoka's and the Curve fitting methods were nearly the same range. 3. The relationships of the field compression index($C_{cfield}$) and virgin compression index($V_{cclab}$) were showed as $C_{cfield}$ = (1.26~1.45)$V_{cclab}$, $C_{cfield}$ = (1.08~1.15) $V_{cclab}$, $C_{cfield}$ = (1.04~1.21)$V_{cclab}$, on the Hyperbolic, Asaoka's and the Curve fitting methods, respectively. 4. The ratio ($C_h/C_v$) of the coefficient of vertical consolidation and the coefficient of horizontal consolidation that is obtained by back-analysis from the settlement data was $C_h$=(0.7~0.9)$C_v$, $C_h$=(0.9~1.5)$C_v$, $C_h$=(2.4~3.0)$C_v$ on the Hyperbolic, Asaoka's and the Curve fitting methods, respectively. 5. It was concluded that the exact consolidation coefficient must be determined after the final settlement is predicted again when the consolidation is finished, because the field consolidation coefficient is decreased as the time allowed to be alone is increased.

  • PDF

Performance of Seedling Grafts of Tomato as Influenced by Root Medium Formulations and Leaching Fractions in Irrigation or Fertigation (혼합상토 조성과 관수 또는 관비시 배액률이 토마토 접목묘 생장에 미치는 영향)

  • Choi, Jong Myung
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.235-243
    • /
    • 2014
  • This research was conducted to investigate the influence of leaching fractions (LF) in each irrigation or fertigation on plant growth and changes in chemical properties of root media during the production of seedling grafts of tomato. Two root media containing Sphagnum peat moss plus vermiculite (5:5, v/v, PV) and coir dust plus vermiculite (5:5, v/v, CV) were formulated and pre-planting fertilizers were incorporated during formulation. Then, each medium was packed into 50 cell (volume 33 cc) and 105 cell (volume 18 cc) trays and the rootstock (cv. J3B Strong) and scion (cv. Sunmyung) were grown, respectively. The seedlings were grafted at 31 days after sowing and then the cut seedling grafts (Sunmyung scion/J3B Strong rootstock) were planted into 50 cell plug trays containing each of the two root media. After induction of the graft union and new adventitious roots for 7 days, the seedling grafts were fed with fertilizer solution once a week containing 4 different N concentrations (0, 50, 100, $200mg{\cdot}L^{-1}$). When determined after 31 days from seed sowing, the highest fresh weights of the root stock seedlings were obtained with 0.75 LF in PV (8.96g/seedling) and CV (7.11g/seedling) mixes. The EC of the both mixes were 0.93 and $1.09dS{\cdot}m^{-1}$, respectively. The fresh weights of the scion seedlings 31 days after seed sowing were 4.29g with 0.50 LF in the PV and 3.13g with 0.50 LF in the CV. The root medium ECs of the two treatments were 0.76 and $1.34dS{\cdot}m^{-1}$, respectively. Fresh weights of the seedling grafts grown for 31 days were greatly influenced by post-planting fertilizer concentrations. The heavier plants were obtained in $100mg{\cdot}L^{-1}$ N treatment than any other treatments in same mixes. The substrate ECs in these two treatments were 0.98 and $1.93dS{\cdot}m^{-1}$, respectively, indicating that the desirable range of soluble salts in soil extracts is higher in the CV mix than the PV mix. Results of this study suggest that optimum EC range is different in each medium and LF need to be adjusted differently for each root medium to produce high quality seedling grafts of tomato.

Feasibility study of using Halcyon LINAC for Double-target spine stereotactic body radiation therapy (이중 표적 척추 전이암의 체부정위방사선치료 시 Halcyon LINAC의 치료 유용성 평가)

  • Jeong Hee Ju;An Ye Chan;Park Byung Suk;Park Myung Hwan;Park Yong Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.51-60
    • /
    • 2022
  • Objectives: The purpose is to evaluate dosimetric performance and delivery efficiency of VMAT with Halcyon LINAC for double target spine SBRT Materials and Methods: 12 patients with spine oligometastases were retrospectively studied. Single-isocenter spine SBRT plans was established using Halcyon® with Dual Layer MLC and Truebeam® with High Definition MLC. All patients' plans were created in Eclipse TPS through the identical conditions and optimization. C.I, H.I, G.I (Gradient Index), maximal and volumetric doses to spinal cord and low dose area were evaluated for comparison of both plans. Also, total MU and BOT(Beam On Time) were evaluated. Results: Halcyon plans was no Statistical differences in C.I and H.I. However, the average of G.I was 4.64 for Halcyon, which decreased to 5.5% compared to Truebeam (P<0.001). Halcyon plans demonstrated statistically significant reduced G.I. The average of 50% and 25% isodose volume was 487.56 cc (-3.82%, P<0.001), 1859.45 cc (-4.75%, P<0.001) in Halcyon, respectively. Significantly reduced low dose spill were observed in Halcyon plans. In the evaluation of the spinal cord, the average of Dmean and V10 of Halcyon plans in the sample group with an overlap volume of less than 1 cc was 6.802 Gy (-3.504%, P=0.067), 5.766±1.683 cc (-8.199%, P=0.002), respectively. Halcyon plans demonstrated statistically significant reduced Dmean and V10. For delivery efficiency, MU and BOT(maximum dose rate for each machine), on average, increased in Halcyon plans. However, the average of BOT(800MU/min for each machine) was 648.33 sec for Halcyon (-1.74%, P<0.001). Conclusion: Halcyon plan for double-target spine SBRT demonstrated advantages in the low dose area with a steep dose gradient, while having dosimetrically equivalent target dose distribution and spinal cord protective effect. As a result, Halcyon LINAC produced a dosimetrically improved plan for double-target spine SBRT.

Chronic Non-Bacterial Prostatitis Treated with Additional Immune Pharmacopuncture: A Case Report (면역약침을 병행한 만성 전립선염/만성 골반통 증후군 환자 치험 1례)

  • Kim, Sang-jin;Kim, Bo-kyum;Kang, Soon-sung;Jung, Hee-jae;Jung, Sumg-ki;Lee, Beom-joon
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.436-445
    • /
    • 2015
  • Objectives The purpose of this study is to report the clinical effects of immuno pharmacopuncture and herbal medicine Simmidojeok-san on chronic non-bacterial prostatitis. Methods The patient was treated with Simmidojeok-san ; 0.2 cc of V pharmacopuncture injection was given into Jeonyang and 0.6 cc of V pharmacopuncture injection was administered into Hoeeum (CV1). National Institutes of Health Chronic Prostatitis Symptom Index (NIH-CPSI) and Numerous Rating Scale (NRS) were used to assess treatment effect. Results NIH-CPSI and NRS decreased after treatment. Conclusions The herbal medicine Simmidojeok-san and V pharmacopuncture therapy are effective in treating chronic non-bacterial prostatitis.