• Title/Summary/Keyword: CASTS

Search Result 388, Processing Time 0.022 seconds

Comparison of Reproducibility of Linear Measurements on Digital Models among Intraoral Scanners, Desktop Scanners, and Cone-beam Computed Tomography

  • Jo, Deuk-Won;Kim, Mijoo;Kim, Reuben H.;Yi, Yang-Jin;Lee, Nam-Ki;Yun, Pil-Young
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • Purpose: Intraoral scanners, desktop scanners, and cone-beam computed tomography (CBCT) are being used in a complementary way for diagnosis and treatment planning. Limited patient-based results are available about dimensional reproducibility among different three-dimensional imaging systems. This study aimed to evaluate dimensional reproducibility among patient-derived digital models created from an intraoral scanner, desktop scanner, and two CBCT systems. Materials and Methods: Twenty-nine arches from sixteen patients who were candidates for implant treatments were enrolled. Different types of CBCT systems (KCT and VCT) were used before and after the surgery. Polyvinylsiloxane impressions were taken on the enrolled arches after the healing period. Gypsum casts were fabricated and scanned with an intraoral scanner (CIOS) and desktop scanner (MDS). Four test groups of digital models, each from CIOS, MDS, KCT, and VCT, respectively, were compared to the reference gypsum cast group. For comparison of linear measurements, intercanine and intermolar widths and left and right canine to molar lengths were measured on individual gypsum cast and digital models. All measurements were triplicated, and the averages were used for statistics. Bland-Altman plots were drawn to assess the degree of agreement between each test group with the reference gypsum cast group. A linear mixed model was used to analyze the fixed effect of the test groups compared to the reference group (α=0.05). Result: The Bland-Altman plots showed that the bias of each test group was -0.07 mm for CIOS, -0.07 mm for MDS, -0.21 mm for VCT, and -0.25 mm for KCT. The linear mixed model did not show significant differences between the test and reference groups (P>0.05). Conclusion: The linear distances measured on the digital models created from CIOS, MDS, and two CBCT systems showed slightly larger than the references but clinically acceptable reproducibility for diagnosis and treatment planning.

A Study on Creative Music Drama Teaching Plans for Pre-service Early Childhood Teachers using Piano Ensemble - Focusing on 'Peter & The Wolf' - (피아노앙상블을 활용한 예비유아교사의 창의적 음악극 지도 방안 - 피터와 늑대를 중심으로 -)

  • Park, Joo-Won
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.1
    • /
    • pp.117-129
    • /
    • 2021
  • Nowadays, the trend of early childhood education has focused on finding educational activities to enhance quality of learning with integrative, learner-centered experience by combining each subject and domain. Pre-service early childhood teacher's music drama activity is a sort of integrated education including literature, instrumental music, play, art and movement that are included in the culture and art for preschoolers to help them understand role and value of the art and directly influence personality and creativity and motive to arouse interest in various learning directly. It's expected to see that development of creative teaching plan for the music drama using piano ensemble could support basic research in integrated educational activity in the teacher training course and also, activate the music drama activity. Research findings and suggestion are as follows. First, the music drama activities are systematically and step-by-step implemented according to the audience according to the cooperative learning and creative plans of pre-service early childhood teachers. Second, if understanding characteristics of casts in the music drama and assigning their roles efficiently, it enhances approach of pre-service early childhood teacher music drama activity and activate it. Third, making music in music drama activities can be composed and arranged to suit the musical literacy and level of pre-service early childhood teacher. Fourth, pre-service early childhood teachers could have integrated experience and evaluation efficiently in the short term to use as reference for the teaching plan and data for the music drama.

A comparative study of impression methods using stock tray and intraoral scanner in a completely edentulous patient with an atypical arch shape: a case report (비정형적인 악궁을 가진 완전 무치악 환자에서 기성 트레이와 구강 스캐너를 이용한 인상 채득 방법의 비교 연구: 증례 보고)

  • Jae-Hoon Park;Ji-Hyun Kim;Jae-Min Seo;Jung-Jin Lee;Yeon-Hee Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.344-355
    • /
    • 2023
  • In complete denture fabrication, accurate preliminary impressions are crucial for obtaining an accurate final impression. However, it can be challenging in cases of atypical arch shapes. This case report compares diagnostic casts made with a stock tray and an intraoral scanner (IOS) in a patient with an atypical arch shape. A 58-year-old edentulous male patient with long, narrow, atypical arches was referred to the Oral and Maxillofacial Surgery department for complete denture fabrication. Compared to the diagnostic cast obtained using IOS with adequately captured anatomical parameters, the primary model obtained using a stock tray showed prominent overextended flanges on the labial and buccal sides of the maxillary arch and less prominent overextended flanges in the mandibular arch with pressure spots in the posterior palatal seal area. The custom tray fabricated from such a model required additional adjustment resulting in increased chair time during the final impression procedure.

The Effect of Variations in the Vertical Position of the Bracket on the Crown Inclination (브라켓의 수직적 위치변동에 따른 치관경사도변화에 관한 연구)

  • Chang, Yeon-Joo;Kim, Tae-Woo;Yoo, Kwan-Hee
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.401-411
    • /
    • 2002
  • Precise bracket positioning is essential in modem orthodontics. However, there can be alterations in the vertical position of a bracket due to several reasons. The purpose of this study was to evaluate the effect of variations in the vertical bracket position on the crown inclination in Korean patients with normal occlusion. From a larger group of what was considered to be normal occlusions obtained from the Department of Orthodontics, College of Dentistry, Seoul National University, each of the final 10 subjects (6 males and 4 females, with an average age of 22.3 yews) was selected. The dental models of each of the subjects were scanned three-dimensionally by a laser scanner, and measurements drawn from these were made on the scanned dental casts of the subjects were input into the computer program. From this the occlusal plane and the bracket plane were determined. The tooth plane was then constructed to measure the crown inclination on the bracket plane of each tooth. From a practical standpoint, information was obtained on the extent to which the torque of a tooth would be changed as the bracket position was to be moved vertically (in ${\pm}0.5mm,\;{\pm}1.0mm,\;{\pm}1.5mm$) from its ideal position. A one way analysis of the variance (ANOVA) was used to compare each group of the different vertical distances from the bracket plane on a specific tooth. Duncan's multiple comparison test was then performed. There were statistically significant differences in the crown inclination among the groups of different vertical distances for the upper central incisor, upper lateral incisor, upper canine, upper first and second molars, lower first and second premolars, and lower first and second molars (p<0.05). On the upper anterior teeth, upper molars, lower premolars and lower molars, the resultant torque values due to the vertical displacement of the bracket were different depending on the direction of the displacement, occlusal or gingival. This study implies that the torque of these teeth should be handled carefully during the orthodontic treatment. In circumstances in which the bracket must be positioned more gingivally or occlusally due to various reasons, it would be useful to provide the chart of torque alteration of each tooth referred to in this study with its specified bracket prescription.

Comparison of micro CT and cross-section technique for evaluation of marginal and internal fit of lithium disilicate crowns (전부 도재관의 변연 및 내면 간극에 대한 micro CT와 절단 시편 측정법의 비교)

  • Ko, In-Seok;Kim, Jeong-Mi;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.226-233
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the adaptation of lithium disilicate crowns fabricated by CAD-CAM (computer aided design-computer aided manufacturing) and heat-press technique to compare two different measurement methods in assessing fit of the ceramic crowns: micro CT and cross-section technique. Materials and methods: A prepared typodont mandibular molar for ceramic crown was duplicated and ten dies were produced by milling the PMMA (polymethylmethacrylate) resin. Ten vinyl polysiloxane impressions were made and stone casts were produced. Five dies were used for IPS e.max Press crowns with heat-press technique. The other five dies were used for IPS e.max CAD crowns with CAD-CAM technique. Ten lithium disilicate crowns were cemented on the resin dies using zinc phosphate cement with finger pressure. The marginal and internal fits in central buccolingual plane were evaluated using a micro CT. Then the specimens were embedded and cross-sectioned and the marginal and internal fits were measured using scanning electronic microscope. The two measurement methods and two manufacturing methods were compared using Mann-Whitney U test (SPSS 22.0). Results: The marginal and internal fit values using micro CT and cross-section technique were similar, showing no significant differences. There were no significant differences in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique. Conclusion: Both micro CT and cross-section technique were acceptable methods in the evaluation of marginal and internal fit of lithium disilicate crown. There was no difference in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique except occlusal fit.

The objective and quantitative analysis of malocclusion : Part 1. Objective malocclusion severity and subjective treatment difficulty (부정교합의 객관적 정량분석: Part 1. 객관적 부정교합 경중도와 주관적인 치료난이도의 상관관계)

  • Joo, Bo-Hoon;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.35 no.1 s.108
    • /
    • pp.60-68
    • /
    • 2005
  • The evaluation of malocclusion has to be done quantitatively and qualitatively. This will be lead toward an analysis of malocclusion severity as well as treatment difficulty. The method of proper evaluation of malocclusion severity and treatment difficulty is necessary to assess treatment effect and efficiency for the orthodontists and to establish fundamentals for planning and executing the health-related policies in private and public institutions. The purposes of this study as the first part of the objective and quantitative analysis of malocclusion were 1) to measure treatment difficulty based on the opinions of several orthodontists. and 2) to investigate the relationships between objective malocclusion severity and subjective treatment difficulty 100 pairs of dental casts that had various types and severity of malocclusion were selected from the orthodontic departments of Kyurghee University and Samsung Medical Center The objective malocclusion severity was measured with the PAR (Peer Assessment Rating) index and the subjective treatment difficulty was evaluated by 8 experienced orthodontists. The relationships between objective malocclusion severity and subjective treatment difficulty were statistically evaluated. There were significant relationships between objective malocclusion severity and subjective treatment difficulty especially in the measurements of the upper anterior alignment, the buccal occlusion. the overjet, the overbite and the midline discrepancy en the malocclusion components. The results of this study can provide the background knowledge to develop a new occlusal index. which contains both the malocclusion severity and treatment difficulty for Korean orthodontists.

The objective and quantitative analysis of malocclusion - Part 2. Influence of malocclusion components to treatment difficulty (부정교합의 객관적 정량분석: Part 2. 부정교합 요소들의 치료난이도에 미치는 영향)

  • Joo, Bo-Hoon;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.35 no.1 s.108
    • /
    • pp.69-81
    • /
    • 2005
  • As one of the variations in growth and development of the craniofacial complex. malocclusion shows lack of concordance In the recognition and severity of malocclusion for dentists as well as the acceptance and need of orthodontic treatment for the patient The purposes of this study were 1) to examine the relationships between objective malocclusion severity aid subjective treatment difficulty. 2) to evaluate the effect of malocclusion components to the subjective perceived difficulty of treatment. 3) to establish the weighted values of malocclusion components to reflect the treatment difficulty 100 pairs of dental casts with the general characteristics of malocclusion. were selected from the orthodontic departments of Kyunghee University and Samsuug Medical Center. The severity of malocclusion was evaluated by the author with the PAR index The perceived treatment difficulty and the estimated treatment duration on these dental models were evaluated by 8 experienced orthodontists. The relationships between the objective malocclusion severity and the subjective treatment difficulty were statistically evaluated. and the weighted values of malocclusion components to reflect treatment difficulty were statistically formulated. There were significant relationships between objective malocclusion severity and subjective treatment difficulty The malocclusion components which significantly affected the treatment difficulty and their weighted values in parentheses were as follows upper anterior alignment(1). overbite (2). buccal occlusion (3) middline (4), and overjet (5). This study Provides the fundamental principle to evaluate the objective malocclusion severity which is reflected by the subjective treatment difficulty of Korean orthodontists.

THE BOND CHARACTERISTICS OF PORCELAIN FUSED BY TITANIUM SURFACE MODIFICATION (타이타늄의 표면개질에 따른 도재 결합 특성)

  • Choi, Taek-Huw;Park, Sang-Won;Vang, Mong-Sook;Yang, Hong-So;Park, Ha-Ok;Lim, Hyun-Pil;Oh, Gye-Jeong;Kim, Hyun-Seung;Lee, Kwang-Min;Lee, Kyung-Ku
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.169-181
    • /
    • 2007
  • Statement of problem: Titanium is well known as a proper metal for the dental restorations, because it has an excellent biocompatibility, resistance to corrosion, and mechanical property. However, adhesion between titanium and dental porcelains is related to the diffusion of oxygen to the reaction layers formed on cast-titanium surfaces during porcelain firing and those oxidized layers make the adhesion difficult to be formed. Many studies using mechanical, chemical and physical methods to enhance the titanium-ceramic adhesion have been actively performed. Purpose: This study meant to comparatively analyse the adhesion characteristics depending on different titanium surface coatings after coating the casts and wrought titanium surfaces with Au and TiN. Material and method: In this study, the titanium specimens (CP-Ti, Grade 2, Kobe still Co. Japan) were categorized into cast and wrought titanium. The wrought titanium was cast by using the MgO-based investment(Selevest CB, Selec). The cast and wrought titanium were treated with Au coating($ParaOne^{(R)}$., Gold Ion Sputter, Model PS-1200) and TiN coating(ATEC system, Korea) and the ultra low fusing dental porcelain was fused and fired onto the samples. Biaxial flection test was done on the fired samples and the porcelain was separated. The adhesion characteristics of porcelain and titanium after firing and the specimen surfaces before and after the porcelain fracture test were observed with SEM. The atomic percent of Si on all sample surfaces was comparatively analysed by EDS. In addition, the constituents of specimen surface layers after the porcelain fracture and the formed compound were evaluated by X-ray diffraction diagnosis. Result: The results of this study were obtained as follows : 1. The surface characteristics of cast and wrought titanium after surface treatment(Au, TiN, $Al_2O_3$ sandblasting) were similar and each cast and wrought titanium showed similar bonding characteristics. 2. Before and after the biaxial flection test, the highest atomic weight change of Si component was found in $Al_2O_3$ sandblasted wrought titanium(28.6at.% $\rightarrow$ 8.3at.%). On the other hand, the least change was seen in Au-Pd-In alloy(24.5at.% $\rightarrow$ 9.1at.%). 3. Much amount of Si components was uniformly distributed in Au and TiN coated titanium, but less amount of Si's was unevenly dispersed on Al2O3 sandblasting surfaces. 4. In X-ray diffraction diagnosis after porcelain debonding, we could see $Au_2Ti$ compound and TiN coating layers on Au and TiN coated surfaces and $TiO_2$, typical oxide of titanium, on all titanium surfaces. 5. Debonding of porcelain on cast and wrought titanium surface after the biaxial flection is considered as a result of adhesion deterioration between coating layers and titanium surfaces. We found that there are both adhesive failure and cohesive failure at the same time. Conclusion: These results showed that the titanium-ceramic adhesion could be improved by coating cast and wrought titanium surfaces with Au and TiN when making porcelain fused to metal crowns. In order to use porcelain fused to titanium clinically, it is considered that coating technique to enhance the bonding strength between coating kKlayers and titanium surfaces should be developed first.

RELATIONSHIP BETWEEN CO-CR DISCREPANCY AND FACIAL SKELETAL TYPE (안면골격 형태와 중심교합위-중심위 변위간의 상관성에 관한 연구)

  • Cho, Jin-Young;Lee, Young-Jun;Park, Young-Guk;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.839-853
    • /
    • 1998
  • The present study was performed to prove the relationship between CO-CR discrepancy and facial skeletal type. In this study, 242 subjects were randomly selected and devided into 9 groups(devided into class I, II, III by ANB and each one devided into dolicho-, brachy-, mesofacial skeleton by Ricketts' vertical index). Lateral cephalometric radiographs with the mandible in centric occlusion were taken and measured and CO and CR bites were registered on all subjects. Diagnostic casts were mounted on Panadent articulator using an estimated face-bow and centric relation bite registration. The amount and direction of CO-CR discrepancy present was recorded using a Condylar Position Indicator(CPI) and a centric occlusion wax bite registration. CPI measurements and cephalometric measurements were statistically analyzed. The finding of this study can be summerized as follows : 1. There is little correlation between right and left sides for magnitude or direction of CO-CR discrepancies. The correlation between the magnitude of CO-CR discrepancy of left A-P and right A-P is higher than that of left S-I and right S-I. 2. Correlation of Class II malocclusion group was higher than that of the other groups between the magnitude of CO-CR discrepancy of left CPI and right CPI. 3. There is no difference between the pattern of CO-CR discrepancy of 9 malocclusion groups. 4. There is very little, if any, correlation between Skeletofacial measurements and CO-CR discrepancy. 5. In Class II brachyfacial skeleton and Class III mesofacial skeleton there was Lateral cephalometric measurements by that we predict CPI measurements was detected. That was overbite, overjet, upper genial angle, lower genial angle, saddle angle, articular angle, convexity of point A, ANS-Me/Na-Me, PCBL/RH, Posterior FH/anterior FH.

  • PDF

The effect of screw tightening techniques on the detorque value in internal connection implant superstructure (내부연결 임플란트 상부구조물에서 나사조임술식이 풀림토크값에 미치는 영향)

  • Choi, Jung-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.243-250
    • /
    • 2010
  • Purpose: This study evaluated the effect of different screw tightening sequences and methods on detorque values in a well-fitting implant superstructure. Materials and methods: A fully edentulous mandibular master model and a metal framework directly connected to four parallel implants (Astra Tech) with a passive fit to each other were fabricated. Six stone casts were made with a splinted impression technique to represent a 'well-fitting' situation with the metal framework. Detorque values were measured twice after screw tightening using 20 Ncm. Detorque values and minimum detorque values for three screw tightening sequences (1-2-3-4, 2-4-3-1, and 2-3-1-4) and for two tightening methods (two-step and one-step) were analyzed using multi-way analysis of variance and two-way analysis of variance, respectively, at a .05 level of significance. Results: The mean detorque values for screw tightening sequences ranged from 12.8 Ncm (2-4-3-1) to 13.1 Ncm (2-3-1-4), and for screw tightening methods were 13.1 Ncm (two-step) and 11.8 Ncm (one-step). The mean of mimimum detorque values for screw tightening sequences were 11.1 Ncm (1-2-3-4) and 11.2 Ncm (2-4-3-1 and 2-3-1-4), and for screw tightening methods were 11.2 Ncm (two-step) and 9.9 Ncm (one-step). No statistically significant differences among three screw tightening sequences were found for detorque values and for mimimum detorque values. But, statistically significant differences between two screw tightening methods were found for two values. Two-step screw tightening method showed higher detorque value (P = .0003) and higher minimum detorque value (P = .0035) than one-step method. Conclusion: Within the limitations of this study, the screw tightening sequence was not a critical factor for the detorque values in a well-fitting implant superstructure by the splinted impression technique. But, two-step screw tightening method showed greater detorque values than one-step method.