• Title/Summary/Keyword: CAS-4

Search Result 282, Processing Time 0.033 seconds

A Study of the comparison of the treatment characteristics between ASA system and CAS system (고도단계유입폭기법과 표준활성슬러지법의 처리특성 비교)

  • Knag, Yong-Tae;Cho, Yong-Hyun;Han, Sang-Yun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.05a
    • /
    • pp.112-115
    • /
    • 2007
  • Currently an increase in domestic sewage and industrial wastewater causes serious water pollution in Korea. To solve water pollution problems, conventional activated sludge (CAS) system is generally used in wastewater treatment plant but this process is so ineffective in nitrogen and phosphorus. Even if CAS system is the major process, it must be improved instantly so as to remove nitrogen and phosphorus. Otherwise, the serious water pollution problems can't be resolved with CAS system. Therefore this study focused on the comparison of the treatment characteristics between ASA system and CAS system. And also the mass balance of each process of ASA system. The results from operating advanced step aeration (ASA) system indicated that the removal efficiency of BOD, COD, and SS was 89.9%, 74.5%, and 89.0% respectively. In comparison, the removal efficiency of BOD, COD, and SS for CAS system was 89.5%, 71.8%, and 89.5% respectively. In addition to the results, the TN removal efficiency of ASA system was 76.5% comparing to 32.7% of CAS system. It was concluded that the TN removal efficiency of ASA system was 44% higher than CAS system. And the TP removal efficiency was 81.4% in ASA system comparing to 25.2% in CAS system. It also means that over 56% of TP was removed in ASA system comparing to CAS system.

  • PDF

Assessment of dentists' subjective satisfaction with a newly developed device for maxillary sinus membrane elevation by the crestal approach

  • Kim, Young-Kyun;Cho, Yong-Seok;Yun, Pil-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.6
    • /
    • pp.308-314
    • /
    • 2013
  • Purpose: The purposes of this study were to assess the dentists' subjective satisfaction with the crestal approach sinus (CAS) kit, a device for maxillary sinus membrane elevation by the crestal approach using a special drilling system and hydraulic pressure, and to summarize the subjective satisfaction of dental implants placed after a sinus lift procedure with the CAS kit. Methods: Thirty dental clinicians who had experience with dental implant placement after a sinus lift procedure with the CAS kit from June 2010 to May 2012 were included in this study. The questionnaire for the evaluation of the dentists' subjective satisfaction with the CAS kit was sent to the respondents and returned. The questionnaire was composed of two main parts. The first part was related to the sinus membrane perforation rate. The second part was related to the dentists' subjective satisfaction with the CAS kit. Results: A total of 28 dentists answered the questionnaire. Among 924 implant cases, sinus membrane perforation occurred in 38 cases (4.1%). Among the 28 dentists, 26 dentists (92.9%) were satisfied or very satisfied with the CAS kit. In particular, 24 dentists (85.7%) reported that safety, cutting performance, and user-friendliness of the CAS drill were advantages of the CAS kit. However, 7 dentists (25%) did not routinely use the hydraulic lifter for sinus membrane elevation. Conclusions: From the survey, it was shown that the respondents were generally satisfied with the CAS kit and that the cutting performance and safety of the drill component were considered strengths of the CAS kit.

Determination of Spatial Resolution to Improve GCP Chip Matching Performance for CAS-4 (농림위성용 GCP 칩 매칭 성능 향상을 위한 위성영상 공간해상도 결정)

  • Lee, YooJin;Kim, Taejung
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1517-1526
    • /
    • 2021
  • With the recent global and domestic development of Earth observation satellites, the applications of satellite images have been widened. Research for improving the geometric accuracy of satellite images is being actively carried out. This paper studies the possibility of automated ground control point (GCP) generation for CAS-4 satellite, to be launched in 2025 with the capability of image acquisition at 5 m ground sampling distance (GSD). In particular, this paper focuses to check whether GCP chips with 25 cm GSD established for CAS-1 satellite images can be used for CAS-4 and to check whether optimalspatial resolution for matching between CAS-4 images and GCP chips can be determined to improve matching performance. Experiments were carried out using RapidEye images, which have similar GSD to CAS-4. Original satellite images were upsampled to make satellite images with smaller GSDs. At each GSD level, up-sampled satellite images were matched against GCP chips and precision sensor models were estimated. Results shows that the accuracy of sensor models were improved with images atsmaller GSD compared to the sensor model accuracy established with original images. At 1.25~1.67 m GSD, the accuracy of about 2.4 m was achieved. This finding lead that the possibility of automated GCP extraction and precision ortho-image generation for CAS-4 with improved accuracy.

Comparison of plasma resistance between spray coating films and bulk of CaO-Al2O3-SiO2 glasses under CF4/O2/Ar plasma etching (CaO-Al2O3-SiO2 계 벌크 유리와 스프레이 코팅막의 CF4/O2/Ar 플라즈마 식각 시 내식성 비교)

  • Na, Hyein;Park, Jewon;Park, Jae-Hyuk;Kim, Dae-Gun;Choi, Sung-Churl;Kim, Hyeong-Jun
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.30 no.2
    • /
    • pp.66-72
    • /
    • 2020
  • The difference of plasma resistance between the CAS glass bulk and coating films were compared. Plasma resistance was confirmed by analyzing the etch rate and the microstructure of the surface when the CAS glass bulk and the glass coating film were etched with CF4/O2/Ar plasma gas. CAS glass coating film was etched up to 25 times faster than the glass bulk. A statistically high correlation between the surface roughness and the etching rate of the coating film was derived, and thus, the high surface roughness of the coating film was determined to cause rapid etching. In addition, cristobalite crystals that has a low Ca content and a high Si content, was foamed on the glass coating film. Therefore, the CAS glass coating film is considered to have low plasma resistance compared to the glass bulk.

Validity Verification of a Korean Version of Recovery Scale(Client Assessment Summary) for Alcoholics (알코올중독자의 회복척도 CAS(Client Assessment Summary) 한국어판의 타당도 검증)

  • Rhee, Young-Sun;Kim, Soo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.386-394
    • /
    • 2016
  • This study investigates the validity of a Korean version of the Client Assessment Summary (CAS), which is a tool used to assess the recovery of alcoholics. We investigated the Korean CAS's suitability for use in assessing the scale of recovery scale of general alcoholics in Korea. In this study, we analyzed the data of 205 abstaining alcoholics in order to determine the validity of the Korean CAS. We undertook relationship analyses of CAS contents, reliability, and composition validity through factor analysis. In addition, we assessed ARS, abstinence period, abstinence self-efficacy, illness insight, and motivation change variables. The factor analysis results, performed after verification of content suitability by assessing 12 questions and 4 factors, confirmed the tool's composition validity, with the results showing relatively high values (R2 = 76.26%, communality ${\geq}0.6$, and KMO = 0.92). Moreover, internal consistency was acceptable (Cronbach's alpha = 0.92), and the correlations among ARS, abstinence self-efficacy, illness insight, and motivation change variables confirmed the validity of the Korean CAS. The proposed Korean CAS is expected to be useful when academically and clinically assessing the recovery of alcoholics; thereby, eventually contributing to successful recoveries from alcoholism.

A Study on the Impact of Continuous Antagonist Strengthening and Evjenth-Hamberg Stretching on the Cervical Mobility in Forward Head Posture Subjects

  • Park, Joo Hyun
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.4 no.2
    • /
    • pp.633-639
    • /
    • 2013
  • This study aims to reveal the impact of continuous antagonist strengthening(CAS) and Evjenth-Hamberg stretching(EHS) on the cervical mobility in the university students with abnormal transformation of forward head posture(FHP). Our experiment was conducted 3 times a week for 6 weeks in a total of 20 individuals : continuous antagonist strengthening(CAS) group(n=10) & Evjenth-Hamberg stretching(EHS) group(n=10). In a pre and post comparison, both CAS group and EHS group appeared significantly in mSBI and SBA(p<.05) and the two-group comparison showed a significant difference(p<.05) : CAS group showed better effects. Thus, it is considered that the combined use with continuous antagonist strengthening(CAS) had better effects for cervical mobility than Evjenth-Hamberg stretching(EHS) alone.

Evaluation of the Genetic Toxicity of Synthetic Chemicals [XII] -in vitro Chromosomal Aberration Assay with 11 Chemicals in Chinese Hamster Lung Fibroblast-

  • Ryu, Jae-Chun;Kim, Youn-Jung
    • Environmental Mutagens and Carcinogens
    • /
    • v.24 no.2
    • /
    • pp.99-107
    • /
    • 2004
  • The validation of many synthetic chemicals that may pose a genetic hazard in our environment is of great concern at present. Since these substances are not limited to the original products, and enter the environment, they have become widespread environmental pollutants, thus leading to a variety of chemicals that possibly threaten the public health. In this respect, the regulation and evaluation of the chemical hazard playa very important role to environment and human health. The clastogenicity of 11 synthetic chemicals was evaluated in Chinese hamster lung (CHL) fibroblast in vitro. Benzoyl chloride (CAS No. 98-88-4) induced chromosomal aberrations with statistical significance at the concentration of 31-123 $\mug/ml$ and 43 $\mug/ml$ in the absence and presence of S-9 metabolic activation system, respectively. 2-Propyn-l-o1 (CAS No. 107-19-7) and 2-Phenoxy ethanol (CAS No. 122-99-6) revealed clastogenicity only at the highest concentration in the presence of S-9 mixture. However, 1-naphthol (CAS No. 90-15-3) which is one of the most cytotoxic chemical among 11 chemicals tested revealed no clastogenicity both in the presence and absence of S-9 metabolic activation system. From the results of chromosomal aberration assay with 11 synthetic chemicals in CHL fibroblast in vitro, Benzoyl chloride (CAS No. 98-88-4), 2-Propyn-l-01 (CAS No. 107-19-7) and 2-Phenoxy ethanol (CAS No. 122-99-6) revealed positive clastogenic results in this study.

  • PDF

Synthesis of CuSbS2 and CuSbSe2 Nanocrystals by a Mechanochemical Method (기계화학적 방법에 의한 CuSbS2와 CuSbSe2 나노입자의 합성)

  • Park, Bo-In;Lee, Seung Yong;Lee, Doh-Kwon
    • Current Photovoltaic Research
    • /
    • v.5 no.4
    • /
    • pp.140-144
    • /
    • 2017
  • $CuSbS_2$ (CAS) and $CuSbSe_2$ (CASe) nanocrystals (NCs), which consist of earth-abundant elements, were synthesized by a mechanochemical method. Elemental precursors such as copper, antimony, sulfur, and selenium were used without adding any organic solvents or additives. The NCs were synthesized by milling for a few hours. The sudden phase changes occurred by self-ignition and propagation, as previously observed in other mechanochemical synthetic processes. The XRD, Raman, and TEM analysis were carried out to determine the crystallinity and secondary phase of the as-synthesized CAS and CASe NCs, confirming the phase-pure synthesis of CAS and CASe. Optical properties were investigated by UV-Vis spectroscopy and it was observed that the band gap energies were about 1.1 and 1.5 eV, respectively for CAS and CASe, suggesting the potential for the use as solar cell materials. The NC colloids dispersed in anhydrous ethanol were prepared and coated on Mo substrates by a facile doctor-blade method. The investigation on the solar cell properties of the as-synthesized materials is underway.

An Ultra-narrow Bandwidth Filter for Daytime Wind Measurement of Direct Detection Rayleigh Lidar

  • Han, Fei;Liu, Hengjia;Sun, Dongsong;Han, Yuli;Zhou, Anran;Zhang, Nannan;Chu, Jiaqi;Zheng, Jun;Jiang, Shan;Wang, Yuanzu
    • Current Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.69-80
    • /
    • 2020
  • A Rayleigh Lidar used for wind detection works by transmitting laser pulses to the atmosphere and receiving backscattering signals from molecules. Because of the weak backscattering signals, a lidar usually uses a high sensitivity photomultiplier as detector and photon counting technology for signal collection. The capturing of returned extremely weak backscattering signals requires the lidar to work on dark background with a long time accumulation to get high signal-to-noise ratio (SNR). Because of the strong solar background during the day, the SNR of lidar during daytime is much lower than that during nighttime, the altitude and accuracy of detection are also restricted greatly. Therefore this article describes an ultra-narrow bandwidth filter (UNBF) that has been developed on 354.7 nm wavelength of laser. The UNBF is used for suppressing the strong solar background that degrades the performance of Rayleigh wind lidar during daytime. The optical structure of UNBF consists of an interference filter (IF), a low resolution Fabry-Perot interferometer (FPI) and a high resolution FPI. The parameters of each optical component of the UNBF are presented in this article. The transmission curve of the aligned UNBF is measured with a tunable laser. Contrasting the result of with-UNBF and with-IF shows that the solar background received by a Licel transient recorder decreases by 50~100 times and that the SNR with-UNBF was improved by 3 times in the altitude range (35 km to 40 km) compared to with-IF at 10:26 to 10:38 on August 29, 2018. By the SNR comparison at four different times of one day, the ratio-values are larger than 1 over the altitude range (25~50 km) in general, the results illustrate that the SNR with-UNBF is better than that with-IF for Rayleigh Lidar during daytime and they demonstrate the effective improvements of solar background restriction of UNBF.