• 제목/요약/키워드: CAR/PDMS

검색결과 21건 처리시간 0.023초

SPME에 의한 소엽의 향기성분 분석 (Analysis of Volatile Compounds in Perilla frutescens var. acuta by Solid Phase Microextraction)

  • 정미숙;이미순
    • 한국식생활문화학회지
    • /
    • 제18권1호
    • /
    • pp.69-74
    • /
    • 2003
  • 우리나라의 고유한 향신료로 활용되고 있는 소엽의 휘발성 향기성분 분석에 적합한 solid phase microextraction(SPME) fiber를 선정하기 위하여 carboxen/polydimethylsiloxane(CAR/PDMS)과 polydimethylsiloxane(PDMS)의 2종류 fiber를 이용하여 향을 추출한 후 GC/MS로 분석하였다. CAR/PDMS fber에 소엽의 향을 흡착시켜 분석한 결과, 39종의 성분이 확인되었으며, PDMS fiber를 이용하였을 때는 20가지의 향기성분이 확인되었다. 특히 PDMS fiber를 사용하였을 때 CAR/PDMS fber를 이용하였을 때 보다 perillaldehyde (40.50%), limonene (27.32%), E,E-,${\alpha}-famesene$ (10.22%) 및 ${\beta}-caryophyllene$ (8.02%)의 소엽의 주요 향기성분이 선택적으로 많이 확인되었다. 따라서 방향성 식용식물인 소엽의 향기를 SPME법으로 추출할 때는 PDMS fiber가 적합하다고 판단된다.

Characterization of the Aroma of Salt-fermented Anchovy Sauce Using Solid Phase Microextraction-Gas Chromatography-Olfactometry Based on Sample Dilution Analysis

  • Kim, Hyung-Joo;Baek, Hyung-Hee
    • Food Science and Biotechnology
    • /
    • 제14권2호
    • /
    • pp.238-241
    • /
    • 2005
  • Aroma-active compounds were evaluated from salt-fermented anchovy sauce by solid phase microextraction-gas chromatography-olfactometry (SPME-GC-O) based on sample dilution analysis (SDA). SPME extract from carboxen/polydimethylsiloxane (CAR/PDMS) fiber was the most similar to the original odor of salt-fermented anchovy sauce used for this experiment, followed by divinylbenzene/CAR/PDMS (DVB/CAR/PDMS) fiber. Because salt-fermented anchovy sauce contains 23% NaCl, NaCl concentration of diluent was considered when salt-fermented anchovy sauce was serially diluted. Linear relationship between GC response and sample concentration was observed when diluted with 23% NaCl solution, whereas not observed when diluted with deodorized distilled water. Eleven and 16 aroma-active compounds were detected by SPME-GC-O based on SDA using CAR/PDMS and DVB/CAR/PDMS fibers, respectively. Butanoic acid and 3-methyl butanoic acid showed the highest ${\log}_2SD$ factors for CAR/PDMS and DVB/CAR/PDMS fibers. Dimethyl trisulfide, methional, trimethyl amine, 1-penten-3-ol, and acetic acid were also detected as potent aroma-active compounds.

SPME에 의한 꽃향유의 휘발성 향기성분 분석 (Analysis of Volatile Compounds in Elsholtzia splendens by Solid Phase Microextraction)

  • 정미숙;이미순
    • 한국식품조리과학회지
    • /
    • 제19권1호
    • /
    • pp.79-82
    • /
    • 2003
  • Volatile compounds in Elsholtzia splendens were extracted by solid phase microextraction (SPME). Two kinds of SPME fiber, carboxen/polydimethylsiloxane (CAR/PDMS) and polydimethylsiloxane (PDMS) were used to determine the selectivity of the fibers to the different flavor compounds present in the Elsholtzia splendens. Identification of volatile compounds was based on the linear retention indices (RI) and the comparison of their mass spectra with those of on-computer library. Thirty compounds were identified in the volatile compounds extracted by CAR/PDMS fiber, including 1 aldehyde, 5 alcohols, 3 hydrocarbons, 17 terpene hydrocarbons, 3 ketones and 1 miscellaneous. And 5 alcohols, 3 hydrocarbons, 18 terpene hydrocarbons, 3 ketones and 2 miscellaneouses were identified in PDMS fiber. These results suggested that the selectivity of PDMS fiber was similar to that of CAR/PDMS fiber in Elsholtzia splendens. The major volatile compounds were naginataketone and elsholtziaketone in Elsholtzia splendens.

Volatile Component of Pine Needles from Pinus densiflora S. using Solid Phase Microextraction-Ges Chromatography-Mass Spectrometry

  • Lee Jae-Gon;Lee Chang-Gook;Back Shin;Jang Hee-Jin;Kwag Jae-Jin;Lee Gae-Ho
    • 한국식품영양학회지
    • /
    • 제18권4호
    • /
    • pp.373-379
    • /
    • 2005
  • The volatile components of Pinus densiflora needles were studied by gas chromatography-mass spectrometry(GC-MS), using seven kinds of solid phase microextraction (SPME) fibers, seven in SPME fibers: 100 ${\mu}m$ PDMS, 65 ${\mu}m$ PDMS/DVB, 65 ${\mu}m$ SF-PDMS/DVB, 85 ${\mu}m$ PA, 75 ${\mu}m$ CAR/PDMS, 65 ${\mu}m$ CW/DVB and 50/30 ${\mu}m$ DVB/CAR/PDMS fibers. A total of 40 components were identified by using the seven different SPME fibers. The identified components were classified, according to their functionalities, as follows: 26 hydro-carbons, 7 alcohols, 4 carbonyl compounds, and 3 esters. The major volatile components of Pinus densiflora needles identified by these SPME fibers were $\alpha$-pinene ($1.7\~21.7\;{\mu}g/g$), $\beta$-myrcene ($2.0\~20.1\;{\mu}g/g$), $\beta$-phel-landrene ($4.6\~22.8\;{\mu}g/g$), $\beta$-caryophyllene ($6.7\~26.0\;{\mu}g/g$) germacrene D ($1.1\~11.9\;{\mu}g/g$). In the comparison of the seven SPME fibers, PDMS appeared to be the most suitable fiber for the analysis of hydrocarbon compounds and CAR/DPMS, PDMS/DVB, CW/VB and DVB/CAR/PDMS are shown to be optimal for analysis of the alcohols and carbonyl compounds.

SPME법을 이용한 전통 향료 유전자원 산초 및 초피의 정유성분 분석 (Volatile Components Analysis using SPME in Traditional Aromatic Plant Resources, Zanthoxylum schinifolium Siebold et Zucc. and Z. piperitum DC)

  • 조민구;채영암;송지숙
    • 한국약용작물학회지
    • /
    • 제9권3호
    • /
    • pp.192-197
    • /
    • 2001
  • 간편하고 효과적인 정유성분 분석을 위해 SPME fiber를 선별하고 산초와 초피의 개체 정유성분 분석에 적합한 SPME fiber를 찾고자 실험한 결과는 다음과 같다. 단일물질별 흡착율은 PDMS, PDMS/DVB, CAR/PDMS 가 우수했다. 10종의 단일물질 표준품 혼합액 흡착 실험에서 직접주입 했을때와 가장 유사한 결과를 보인 것은 PDMS, PDMS/DVB fiber이였다. 최종 선발된 PDMS와 PDMS/DVB를 이용하여 24종의 단일물질 표준품 흔합액 흡착과 직접주입시를 비교한 결과 이들 간에 차이가 없었다. 또한 GC주입구의 split ratio별 성분의 검출에서도 차이가 없었다. 흡착시간이 길어질수록 분자량이 큰 성분의 흡착율이 높아지는 경향을 보였지만, 직접주입시와 비교해 볼 때 적절한 흡착시간은 30-40분이였다. SDE 추출물을 이용한 산초와 초피나무 개체 정유성분 분석에는 산초와 초피 모두 PDMS/DVB가 흡착시간 30-40분에서 분자량이 큰 sesquiterpene류까지 흡착하는데 유리하였다.

  • PDF

Optimization of Headspace Sampling Using Solid Phase Microextraction For Volatile Organic Acids in Different Tobacco Types

  • Lee, Jang-Mi;Lee, Jeong-Min;Son, Seong-Ae;Kwon, Young-Ju;Jang, Gi-Chui;Kim, Young-Ho
    • 한국연초학회지
    • /
    • 제35권1호
    • /
    • pp.7-12
    • /
    • 2013
  • A Solid-phase micro extraction(SPME) was evaluated as a tool for headspace sampling of tobacco samples. Several experimental parameters (sampling temperature, pH, and type of SPME fibers) were optimized to improve sampling efficiency in two aspects ; maximum adsorption and selective adsorption of volatile organic acids onto SPME fibers. Among four types of SPME fibers such as PDMS(Polydimethylsiloxane), PA(Polyacrylate), Car/PDMS (Carboxen/Polydimethylsiioxane) and PDMS/DVB(Polydimethylsiioxane/Divinylbenzene) which were investigated to determine the selectivity and adsorption efficiency. A variety of tobacco samples such as flue cured, burley and oriental were used in this study. The effect of these parameters was often dominated by the physical and chemical nature (volatility, polarity) of target compounds. This method allowed us to make important improvements in selectivity and sensitivity. The Car/PDMS fiber was shown to be the most efficient at extracting the 10 selected volatile organic acids. The parameters were optimized: $80^{\circ}C$ adsorption temperature, 30 min of adsorption time, $240^{\circ}C$ desorption temperature, 1 min of adsorption time.

Solid Phase Microextraction을 이용한 계피의 향기성분 분석 (Analysis of Aroma Compounds of Cinnamon by Solid Phase Microextraction)

  • 이창국;이재곤;장희진;곽재진
    • 한국식품영양학회지
    • /
    • 제16권4호
    • /
    • pp.372-378
    • /
    • 2003
  • SDE 및 SPME를 이용하여 계피로부터 추출한 휘발성 향기성분을 GC/MSD 분석한 결과 terpenes 20종, alcohol 3종, carbonyl 5종, esters 2종으로 총 30개의 휘발성 성분을 확인하였다. 이들 중 trans-cinnamaldehyde (86.4%), cis-cinnamaldehyde(0.9%), hydrocinnamaldehyde (0.1%) 등의 carbonyl 화합물이 peak area% 기준으로 약 88.2%로 계피 중 대부분을 차지하는 것으로 나타났다. 또한 식물체의 향기성분 분석에 많이 이용되는 SPME fiber 4종류를 비교 분석한 결과 terpen류 화합물들은 PDMS fiber에서 추출효율이 가장 좋았으며, cinnamyl alcohol과 같은 다소 극성인 화합물의 경우 DVB/CAR/PDMS fiber와 PA fiber에서 추출 효율이 가장 좋은 것으로 나타났다. SPME법에서 최적 조건을 설정하기 위해 추출온도와 추출시간을 달리하면서 비교 분석한 결과 copaene, murolene, cadinene, cis-cinnamaldehyde 등의 area% 값은 온도와 시간이 커질수록 증가한 반면에 trans-cinnamaldehyde의 area% 값은 감소하였다.

ICP-AES와 SDE, HS-SPME-GC/MS를 이용한 참나물의 무기성분과 향기성분 (Analysis of Mineral and Volatile Flavor Compounds in Pimpinella brachycarpa N. by ICP-AES and SDE, HS-SPME-GC/MS)

  • 장경미;정미숙;김미경;김건희
    • 한국식생활문화학회지
    • /
    • 제22권2호
    • /
    • pp.246-253
    • /
    • 2007
  • 참나물의 잎과 줄기부위에서 가장 많이 함유하고 있는 무기 성분은 K, P, Ca, Mg 순이었으며 잎 부위가 줄기부위보다 Ca, P, Mg함유량이 약 4배 정도 많았다 전자코를 이용한 휘발성 향기성분 패턴은 신선한 참나물의 경우 제1주성분 값이 +값을, 음건한 건조 참나물은 - 값을 나타내어서 신선한 참나물과 건조한 참나물 사이에는 뚜렷한 차이를 보였고 건조방법에 따른 시료간의 구별이 가능하였다. SDE법에 의해 신선한 참나물은 aldehydes 3종, alcohols 9종, ester 4종, hydrocarbons 5종, terpen hydrocarbons 34종, ketone 1종, 기타 2종의 총 58 종이 확인되었고, 음건한 참나물은 aldehydes 4종, alcohols 7종, hydrocarbon 1종, terpen hydrocarbons 17종, ketone 1종, 기타 1종의 총 31종이 확인되었다. SDE법에 의한 신선, 음건한 참나물 모두 ${\alpha}$-selinene(37.89%, 12.59%)가 가장 많이 확인되었는데 신선할 때보다 음건한 경우 휘발성향기성분의 peak수와 peak area%가 적었다. CAR/PDMS fiber HS-SPME법에 의해 34종이 확인되었는데 aldehydes 2종, alcohols 2종, hydrocarbons 7종, terpen hydrocarbons 23종이며 myrcene(15.50%)가 가장 많이 확인되었다. PDMS fiber HS-SPME법에 의해 aldehydes 1종, alcohols 1종, hydrocarbons 2종, terpen hydrocarbons 17종으로 총 21종이 확인되었고 germacrene D(16.84%)가 가장 많았다. SDE법에 의한 경우가 SPME법보다 향기성분의 종류와 양이 많았고 HS-SPME법의 경우 CAR/PDMS fiber가 PDMS fiber 보다 더 많은 종류의 향기가 확인되었다.

Development of analytical method for potential diesel oxygenate using SPME technique combinded with GC-FID

  • 이규현;이시진;장순웅
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.354-357
    • /
    • 2004
  • The addition of oxygenates to diesel fuel can significantly reduce particulate emissions. Dibutyl maleate (DBM) and tripropylene glycol methyl ether (TGME) have been identified as possible additives based on their physicochemical characteristics and performance in engine test. However, their potential environmental impacts are unknown. therefore, practical considerations in the selection of an oxygenate additives should include cost, availability, compatibility with engines and fuel, and, particularly, its overall environmental impact. This study was investigated to determine optimal condition for the analysis of potential diesel oxygenates using SPME technique with GC-FID. Four fibers were compared and CAR/PDMS fiber was found to be the most sensitive when used direct-sampling. An absorption time of 30min and a desorption time of 5min provided to be the most sensitivity. The effects of experimental parameters such as the addition of salts, agitation, absorption time, compositon on the analysis were investigated. Analytical parameter such as linearity was also evaluated.

  • PDF

The Evaluation of Solid-Phase Microextraction(SPME) Techniques for Analyzing Mixed Fuel Oxygenates and Products

  • 이재선;이시진;장순웅
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.458-461
    • /
    • 2003
  • Solid-phase microextraction (SPME) and gas chromatography/headspace techniques(HS) and flame ionization detection (GC/FID) have been combined for determination of very polar compounds in water, including the widely used gasoline oxygenates and by-products. A relatively simple extraction method using a CAR/PDMS(75${\mu}{\textrm}{m}$) SPME fiber was optimized for the routine analysis of gasoline oxygenates and by-products in groundwater and reagent water. A sodium chloride concentration of 25%(w/w) combined with an extraction time of 20 min provided the greatest sensitivity while maintaining analytical efficiency Replicate analyses in fortified reagent and groundwater spiked with microgram per liter concentrations of gasoline oxygenates and by-products indicate quantitative and reproducible recovery of these and related oxygenate compounds. Method dynamic range was 50$\mu\textrm{g}$ L-1 to 3000$\mu\textrm{g}$ L-1 for gasoline oxygenates and by-products.

  • PDF