• Title/Summary/Keyword: CAM(Computer-Aided Manufacturing)

Search Result 241, Processing Time 0.026 seconds

Product Model for the Integration of Design and Manufacturing Information in Shipbuilding (선박의 설계 및 생산 정보의 통합을 위한 Product Model 의 구축)

  • S.B. Yoo;J.W. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.2
    • /
    • pp.1-12
    • /
    • 1993
  • The role of product model in CIM environemt(where such heterogenous application programs as CAD, CAE, CAM, Database, and Expert Systems are included) is system integration. Product model manages all the information related to manufacuring activities. This information includes shapes, operation, process, scheduling, quality, and mangement. Product model architecture includes product model kernel, object schema, model manipulation language, and user interface. Objects to be shared are defined using the model manipulation luage and the defintions are saved in the object schema. In this paper, we present the design and implementation of a prototype. In this prototype, application programs for CAPP(Computer Aided Process Planning) are used.

  • PDF

Evaluation of Marginal and Internal Gap of Cobalt-Chromium Sintering Metal Coping Fabricated by Dental CAD/CAM System (치과 CAD/CAM 시스템으로 제작한 코발트-크롬 소결 금속 코핑의 변연 및 내면 적합도 평가)

  • Kim, Dong-Yeon;Sin, Chun-Ho;Jung, Il-Do;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.536-541
    • /
    • 2015
  • The purpose of this study was to evaluate the marginal and internal gap of Cobalt (Co)-Chromium (Cr) sintering metal coping fabricated by dental computer-aided design/computer-aided manufacturing systems. Abutment tooth 46 of universal numbering system was selected for the study. Twenty Co-Cr metal copings of two groups were manufactured and scanned. Co-Cr cast metal copings (CCM) group of ten were fabricated using investment, burnout and casing after subtractive manufacturing of wax block. Also, Co-Cr sintering metal copings (CSM) group of ten were fabricated using sintering processing after subtractive manufacturing of Co-Cr soft metal bock. Marginal and internal gap of Co-Cr metal copings of twenty were measured by digital microscope (${\times}160$) with silicone replica technique. The data was analyzed from IBM SPSS Statistics ver. 22.0 Statistical software for Mann-Whitney U test (${\alpha}=0.05$). $Mean{\pm}standard$ deviation of marginal gap of CCM group was $90.12{\pm}61.73{\mu}m$ of CSM group was $60.17{\pm}24.83{\mu}m$. However, two groups was statistically not different (p>0.05). This study showed that CSM group was clinically acceptable adaptation.

Machining for Outsole Mold of Shoes Using CAD/CAM (CAD/CAM을 이용한 구두창 금형 가공)

  • Park Yong-Bok;Yum Jeong-No;Hwang In-Keuk
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.28 no.1
    • /
    • pp.24-31
    • /
    • 2005
  • The outsole mold of the shoes has been manufactured using electro-discharge machining by graphite electrode or using casting etc. The study is concerned with the pattern design for the outsole of shoes by CAD, the modeling and the generation of NC data by CAM system and the machining by CNC machining center. The ball end mill and the engraving cutter is used as cutter and the cutting conditions are adjusted according to the shapes and sizes of the cutter and part in cutting. The method showed the possibility coping with the rapid change of shoes industry and proposed the possibility for higher productivity and quality on mold-manufacturing of shoes outsole.

New CAD Datarization Technique of Shoe Lasts and Data Extraction Scheme for the control of the Adaptive Lasting Machine (제화용 라스트의 새로운 DAD Data화 기법 및 적응형 라스팅기의 제어를 위한 데이터 추출)

  • Kim, Seung-Ho;Jang, Kwang-Keol;Huh, Hoon
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.122-127
    • /
    • 2001
  • Lasting machines for shoe manufacturing are continuously developed with the aid of automation and Computer Aided Manufacturing (CAM). Although automation and CAM techniques have tremendously reduced the labor in shoe manufacturing field, there still remain some parts manufactured by experts. In order to enhance the capability and efficiency of machines for labor-free shoe manufacturing, CAD data of a shoe last is indispensable. While CAD datarization takes the fundamental role in the shoe design as well as the shoe manufacturing, there has been little research for the CAD datarization of a shoe last. In this paper, a new procedure for CAD datarization of a shoe last using finite element patches is proposed and some data for the control part of the shoe lasting machine are extracted and interpolated from the CAD data. The outer line of a shoe-last sole is interpolated by a tension spline method and bonding lines are extracted from the shoe CAD data. Finally, initial setting data for the lasting machine are extracted from the last CAD data and initial setup parts of the lasting machine.

  • PDF

Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot

  • Choi, Kyu-Hyung;Son, KeunBaDa;Lee, Du-Hyeong;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.381-387
    • /
    • 2018
  • PURPOSE. Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with lingual slots, known as retrievable cement-type slots (RCS). MATERIALS AND METHODS. We fabricated six types of titanium abutments (10 of each type) with two different heights (4 mm and 6 mm), three different convergence angles ($8^{\circ}$, $10^{\circ}$, and $12^{\circ}$), a sloped shoulder margin (0.6 mm depth), a rectangular shape ($6mm{\times}6.5mm$) with rounded edges, and a rectangular ledge ($2mm{\times}1mm$) for the RCS. One monolithic zirconia crown was fabricated for each abutment using a dental computer-aided design/computer-aided manufacturing system. The abutments and crowns were permanently cemented together with dual-curing resin cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device with a slot driver and torque gauge, we recorded the torque ($N{\cdot}cm$) required to remove the crowns. Statistical analysis was conducted using multiple regression analysis and Mann-Whitney U tests (${\alpha}=.05$). RESULTS. Removal torques significantly decreased as convergence angles increased. Multiple regression analysis showed no significant interaction between the abutment height and the convergence angle (Durbin-Watson ratio: 2.186). CONCLUSION. Within the limitations of this in vitro study, we suggest that the retrievability of cement-retained implant prostheses with RCS can be maintained by adjusting the abutment height and convergence angle, even when they are permanently cemented together.

Esthetic Rehabilitation of Anterior Dentition by All Ceramic Crowns Using IPS e.max CAD : A Case of Tetracycline Discoloration (전치부 전부도재관을 이용한 테트라싸이클린 착색의 심미보철 회복 증례 (IPS e.max CAD 블록의 이용))

  • Kim, Jae-Hong;Cho, Young-kyu;Kim, Hae-Young
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.299-303
    • /
    • 2011
  • The purpose of this case report was to present an example of an esthetic and functional rehabilitation of anterior teeth with tetracycline discoloration and minor morphological abnormality of a 39-year old female. A chairside computer-aided design/computer-aided manufacturing (CAD/CAM) system with CEREC AC was applied for the prosthetic procedure and all ceramic crowns made with lithum disilicate (IPS e.max CAD) restored the esthetic and functional features of sixteen anterior teeth successfully.

Study on Configuration Design Sensitivity of Noise & Vibration (소음/진동의 컨피규레이션 설계 민감도 연구)

  • 왕세명;기성현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.192-198
    • /
    • 1997
  • In the concurrent engineering, the CAD-based design model is necessary for multidisciplinary analysis and for computer-aided manufacturing (CAM). A shape and configuration design velocity field computation of structure has been developed using a computer-aided design (CAD) tool, Pro/ENGINEER. The design Parameterization with CAD tool is to characterize the change in dimensions and movements of geometric control points that govern the shape/orientation of the structural boundary. The boundary velocity is obtained by using a CAD-based finite difference method and the domain velocity field is obtained from finite element analysis (FEA) using the boundary displacement method. In this paper, the continuum configuration DSA for NVH problem, which requires the shape velocity field and the orientation velocity field at the same time, is developed using linear shape functions. For validation of continuum design sensitivity coefficients, design sensitivity coefficients are compared with the coefficients computed using by the finite difference method.

  • PDF

서초프로젝트A 오피스텔 현장의 SHOP DWG

  • Kim, Hyeon-Ung
    • 월간 기계설비
    • /
    • no.11 s.184
    • /
    • pp.57-71
    • /
    • 2005
  • SHOP DWG의 현주소 어디까지 왔는가? 설계에서 제조에 이르는 전 과정을 컴퓨터로 제어하고 관리하는 기술. 캐드(CAD)와 캠(CAM)은 각각 computer-aided design,computer-aided manufacturing의 약칭으로 컴퓨터보조설계와 컴퓨터보조생산을 뜻한다. CAD는 설계도면을 한 장씩 수작업으로 제도하지 않고 설계 데이터베이스의 정보를 CRT(cathode ray tube)에서 화상을 보고 합성하면서 설계하므로 작업을 최적화 할 수 있다. CAD로 설계된 설계도의 내용은 CAM을 통해 NC(수치제어)공작기계에 정확한 작업동작을 지시하게 되며, 작업관리∙가공∙조립∙검사 등의 제조과정을 컴퓨터로 관리하여 작업속도와 제품의 정밀성을 높이게 된다. 최근에는 건축현장의 2D system이 보편화되어 있지만 건축현장의 핵심이라고 할 수 있는 기계설비의 기계실, 또는 조립화 공법 등에는 3차원 CAD∙CAM시스템이 개발되어 입체형상을 화면에 3차원으로 재현할 수 있고, 대상물의 표면적∙부피∙무게∙강도 등의 물리적 성질도 자동 계산하여 최적상태에서 현장의 시공에 적용할 수 있게 되었다. 1960년대 초 미국에서 자동차 모델∙엔진, 항공기 부품 등 의 설계에 수작업의 한계를 느껴 개발되었으며, 한국에서는 70년대 중반에 도입되어 운용되고 있다. 이에 따라 프로그램 회사들은 다양한 방법 등을 SHOP DWG에 적용하여 판매경쟁이 치열하다. (주)우진아이엔에스는 급속한 산업경제의 변화와 무한경쟁시대에 보다 나은 기술개발 투자에도 노력을 기울여, 2000년 11월 용인공장, 생산라인을 천안으로 이전, 확장 하여 배관 및 닥트의 CAD-CAM SYSTEM, P.F.P공법, 기계실3D, 블럭화배관, 닥트자동화 시스템, 설계, 용접공정을 공장화시켰으며, 신 개발품인 S.C.D(SEMI-CON DUCT)를 신설하여 모든 건축물에 맞는 필수적인 제품을 생산함으로써 선택의 폭을 넓히고, 현장 시공능력 효율을 높이고 있다. 이번 호에서는 (주)우진아이엔에스가 95년 설계팀을 발족하여 제로시스템의 3D공법을 공장 및 현장의 SHOP DWG에 적용해왔고 최근에는“서초 프로젝트A”현장에 SHOP DWG의 최대 결집체인 3D활용의 조립화 공법을 적용하여 초고층 오피스텔현장을 시공한 사례를 게재한다. 우진아이엔에스는 30여년의 기술 축척을 바탕으로 최고의 기술력과 풍부한 경험을 통해 아셈무역센타, 타워팰리스1차, 3차 및 목동트라팰리스, 분당트리폴리스, 수원삼성전자 R4, 등 국내굴지의 초고층빌딩 시공을 근거로 초고층의 기본설계를 이해하고 SHOP DWG을 통해서 기계설비공사의 향후 나아갈 지표를 제시하고 있다.

  • PDF

Oral rehabilitation that transit from optimized provisional through continuous re-evaluation to definitive prosthesis using CAD/CAM system: A case report (지속적인 재평가를 통해 최적화된 임시 보철을 최종 보철로 이행한 전악 CAD/CAM 고정성 수복 증례)

  • Lee, Suji;Woo, Yi-Hyung;Pae, Ahran;Noh, Kwantae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.444-450
    • /
    • 2017
  • Prosthetic decision-making is complex because of various factors, and involves a combination of the individual dentist's interpretation of the objective clinical data and his or her interaction with the patient. Increasing therapeutic options and emerging outcome data demand the constant re-evaluation of our decision-making process. In this case, fixed prosthetic restorations were selected as a treatment method to reconstruct the occlusal plane of a patient with disharmonious occlusal plane. And the occlusal plane was re-established by establishing a treatment plan through diagnostic wax-up. Provisional restorations obtained by continuous re-evaluation for a sufficient period of time was replicated to definitive restorations using CAD/CAM technology. The results were satisfactory when they were observed through clinical follow-up for 3 months after the end of treatment.

Evaluation of Marginal Gap of Fixed Dental Prostheses Fabricated by Soft Metal Material Using Dental CAD/CAM (치과용 캐드캠을 이용하여 연질금속 재료로 제작한 고정성 보철물의 변연 간격 평가)

  • Kim, Jae-Hong;Kim, Won-Soo;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.14 no.3
    • /
    • pp.349-355
    • /
    • 2014
  • The purpose of this study was to evaluate marginal gap of fixed dental prostheses (FDPs) fabricated by soft metal material with using dental computer aided design/computer aided manufacturing (CAD/CAM) system and to compare gap of its by a conventional method. Ten same cases of study models were manufactured and scanned for digital models fabricating. Ten FDPs were fabricated by soft metal material using dental CAD/CAM (SMB group). Then, ten FDPs were fabricated by cast metal using lost wax technique and casting method (LWC group). Marginal gap was measured by silicone replica technique. Gap was measured by digital microscope (${\times}160$). Mann-Whitney test for statistical analysis was executed (${\alpha}=0.05$). The mean (standard deviations) of marginal gap was $76.5{\mu}m$ (35.2) for the SMB group, and $82.9{\mu}m$ (22.1) for the LWC group. Statistically significant differences were not found between SMB and LWC. As results, FDPs fabricated by soft metal material were clinically acceptable range.