• Title/Summary/Keyword: CAD/CAM dentistry

Search Result 455, Processing Time 0.02 seconds

Evaluation of validity of polyurethane model fabricated by intra-oral scanning method (구강 내 스캐닝 방법에 의해 제작된 폴리우레탄 모형의 정확도 평가)

  • Kim, Won-Tae;Lee, Byung-Ki;Hyun, Joung-Ku;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.36 no.2
    • /
    • pp.91-96
    • /
    • 2014
  • Purpose: The purpose of this study was evaluate the validity of polyurethane model fabricated by intra oral scanning method. Methods: Ten sam cases of stone models were manufactured from master model, and polyurethane models were made with the intra oral scanning and CNC milling method. One examiner individually measured 6 distances(intercanine distance, intermolar distance, two dental arch lengths(right, left) and two diagonal of dental arch lengths(right, left) on the stone models and the polyurethane models. The Mann-Whitney U test(${\alpha}$=0.05) were used for statistical analysis. Results: The mean difference between measurements made directly on the stone models and those made on the polyurethane models was 0.31-0.38mm. No statistically differences between the two groups were founded 4 distances(p>0.05), but 2 distances were statistically significant(p<0.05). Conclusion: Stone models showed larger than polyurethane models fabricated by intra oral scanning method.

Effect of zirconia ceramic sintering condition on the precision of fit in dental restorations (지르코니아 세라믹 소결조건이 치과보철물의 적합도에 미치는 영향)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.121-128
    • /
    • 2020
  • Purpose: This study aimed to investigate the effects of the sintering conditions of zirconia core on the adaptability. Methods: Ten specimens of each of commercial brand of zirconia(Razor 1100, U&C international, Seoul, Korea) were made and sintered under three different conditions. Specimens were divided into three subgroup(n=10) and sintered with various total time(1hr, 3hr, 9hr) at the maximum temperature(1500℃). The digitized data was superimposed with 3D inspection software to quantitatively obtain the adaptation of a zirconia core, and visual differences were confirmed with a color map. The root mean square(RMS) values of group were statistically analyzed with one-way ANOVA(α=0.05). Results: The overall adaptation of the zirconia cores were as follows; ss-1hr: 36.18±5.2㎛, ss-3hr: 39.55±3.9㎛, cs-9hr: 46.62±4.3㎛. They were statistically significant differences between groups for adaptation(p<0.05). Conclusion: Based on the results of this study, it could be considered that sintering condition of 1500℃ and 1~3 hour is recommended for the better marginal and internal fit. Speed sintering can be widely utilized to fabricate zirconia prothesis as the properties of those almost are to dentistry uses.

Review of clinical studies applying yttrium tetragonal zirconia polycrystal-based esthetic dental restoration (치과용 지르코니아로 제작된 심미보철물의 임상적 예후에 관한 문헌고찰)

  • Kim, Jae-Hong
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.307-312
    • /
    • 2020
  • Application of ceramic materials for fabrication of dental restoration materials has been a focus of interest in the field of esthetic dentistry. The ceramic materials of choice are glass ceramics, spinel, alumina, and zirconia. The development of yttrium tetragonal zirconia polycrystal (YTZP)-based systems is a recent addition to all-ceramic systems that have high strength and are used for crowns and fixed partial dentures. Computer-aided design/computer-aided manufacturing (CAD/CAM)-produced, YTZP-based systems are popular with respect to their esthetic appeal for use in stress-bearing regions. The highly esthetic nature of zirconia and its superior physical properties and biocompatibility have enabled the development of restorative systems that meet the demands of today's patients. Many in vitro trials have been performed on the use of zirconia; however, relatively fewer long-term clinical studies have been published on this subject. The use of zirconia frameworks for long-span fixed partial dentures is currently being evaluated; in the future, more in vivo research and long-term clinical studies are required to provide scientific evidence for drawing solid guidelines. Further clinical and in vitro studies are required to obtain data regarding the long-term clinical use of zirconia-based restorations.

Rehabilitation using twin-stage method for a Sjögren's syndrome patient with severe discoloration and attrition on upper and lower anterior teeth (상하악 전치부 심한 변색과 마모를 보이는 쉐그렌 증후군 환자에서 twin-stage법을 이용한 수복증례)

  • Lee, Seon-Ki;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.291-297
    • /
    • 2016
  • Patients with $Sj{\ddot{o}}gren^{\prime}s$ syndrome usually suffer from teeth discoloration and attrition due to xerostomia. If the anterior teeth are badly worn, problems such as loss of anterior guidance, occlusal disharmony, and limited space for restoration may occur. However, ideal occlusion is obtained in both centric and eccentric relation by regaining the disocclusion of the posterior teeth through the anterior and lateral guidance using twin-stage method. In this case, rehabilitation was performed for a $Sj{\ddot{o}}gren^{\prime}s$ syndrome patient with maxillary and mandibular incisor's severe attrition and teeth discoloration by using twin-stage method.

Rehabilitation in a patient with limited restorable space using double scanning technique: A case report (구치부 보철 수복 공간이 부족한 환자에서 이중 스캔을 이용한 구강회복 증례)

  • Kim, Jun-Yub;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug;Yang, Hongso
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.205-211
    • /
    • 2017
  • Loss of posterior support may cause extrusion of antagonistic teeth and excessive wear of remaining teeth which often leads to the destruction of the occlusal plane. In such cases, it is critical to verify the need to increase vertical dimension of occlusion (VDO). Should you increase VDO, provisionalization is crucial in evaluating function and esthetics. Double scanning technique is a useful method when fabricating definitive restoration that mimic provisional restoration. In this case, a patient with apparently no loss of VDO and insufficient interocclusal space for dental materials due to loss of posterior support and extrusion of antagonistic teeth was rehabilitated using double scanning technique.

Restoration of anterior teeth with dental implant using multilayer zirconia (다층 지르코니아를 이용한 임플란트 전치부 수복 증례)

  • Lee, Sunghee;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.469-477
    • /
    • 2021
  • For successful restoration of maxillary anterior implants, both pink esthetics and white esthetics must be satisfied. For pink esthetic part, the role of appropriate provisional prosthesis restoration is important, and for white esthetic part, the color and shape of the definitive prosthesis is important. Multilayer zirconia can be used for natural tooth appearance due to the higher transparency of the incisal area compared to the conventional monolithic zirconia. Therefore, in this case, white esthetic part was achieved through multilayer zirconia after recovering function and esthetics through appropriate provisional prosthesis in a patient who lost the maxillary anterior teeth.

A case report of single crown restoration using an intraoral scanner for occlusal evaluation (단일 치관 수복 시 구강스캐너를 이용한 교합평가 활용 증례보고)

  • Song, Jun-Beom;Lee, Jong-Hyuk;Ha, Seung-Ryong;Choi, Yu-Sung;Choi, Sun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.341-349
    • /
    • 2021
  • The evaluation of occlusion using digital methods is easier and simpler in terms of recording, comparison, analysis, and objectivity compared to existing methods such as articulating paper and occlusion foil. The purpose of this case report was utilizing the digital method for evaluating occlusion. The occlusion of patient requiring full veneer crown restoration was evaluated using an intraoral scanner (i500, Medit, Seoul, Korea) at every visit. The occlusion was also assessed using conventional articulating paper and a digital occlusal analysis system (Dental prescale II, GC corp., Tokyo, Japan) for comparison. Throughout the treatment process, the intraoral scanner and the conventional articulating paper method showed similar outcomes. The results suggest that the use of digital evaluation system is highly probable in the near future.

Effect of drill radius setting on prosthesis machining (드릴 반경 설정이 보철물 가공에 미치는 영향)

  • Kim, Chong-Myeong;Kim, So-Ri;Cho, Mi-hyang
    • Journal of Technologic Dentistry
    • /
    • v.40 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the trueness and fitness of machined prostheses according to drill radius setting in CAD software. Methods: For this study, standard abutment were replicated in Type IV stone. The stone abutment were scanned using a dental scanner. The CAD design software was designed using scanned abutment data. When designing, the drill radius was set to 0.3 mm and 0 mm, respectively, and saved. The saved design data was milled using a milling machine (n=13). The inner surface of the milled crown was scanned. The trueness and fitness were measured using the inner scan data of prostheses. Independent t-tests were performed to identify significant differences in each data. Results: Trueness values of the data saved with 0.3 mm and 0 mm drill radius were $18.9{\pm}2.3{\mu}m$ and $19.1{\pm}0.9{\mu}m$, respectively. There was no statistically significant difference between the groups. Fitness values of the data saved with 0.3 mm and 0 mm drill radius were $65.5{\pm}0.8{\mu}m$ and $33.8{\pm}1.0{\mu}m$, respectively. There was a statistically significant difference between the groups (p<.05). Conclusion : Setting the drill radius is important to produce clinically good fit prostheses.

Changes in occlusal force depending on the movement of the adjacent and opposing teeth after loss of lower first molar: comparative study by using a strain gauge (하악 제1대구치 상실 시 인접 및 대합 치아들의 이동양상에 따른 교합력 변화: 스트레인게이지를 이용한 비교 연구)

  • Song, Myoung-Ja;Park, Ji-Man;Chun, Youn-Sic
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.47-59
    • /
    • 2016
  • Purpose: The aim of this study was to investigate the changes in occlusal force after loss of the lower first molar depending on the inclination and extrusion of the adjacent and opposing teeth by using a strain gauge. Materials and Methods: Anatomic teeth were used to reconstruct the normal dental arch with loss of the lower right first molar. A uniformly thick layer of silicone was applied to the root to mimic the periodontal ligament. Four stages of dies with varying degrees of inclination and extrusion of the adjacent and opposing teeth were constructed and attached to master model interchangeably by using a CAD/CAM fabricated customized die system. The strain gauges were attached to teeth and a universal testing machine was used to determine the changes in occlusal force. An independent t-test and one-way ANOVA were performed (${\alpha}=.05$). Results: While simulating chewing food, the upper first, second premolar and lower second molar showed greater occlusal force than before extraction. When the change of adjacent teeth's occlusal force with their progressive movement after molar loss was evaluated, the difference among four die models was significant and was in the decreasing aspect (P < 0.05). Conclusion: When the lower first molar was lost and the adjacent teeth did not move yet, the occlusal force in adjacent teeth was higher than that when the lower first molar still existed. In addition, the occlusal force in the upper premolars and lower second molar decreased significantly with the progressive movement of adjacent teeth.

THREE-DIMENSIONAL ANALYSIS OF THE NORMAL DENTITION AND EDENTULOUS MAXILLA OF KOREANS (한국인의 상악 유치악 치열 및 무치악 치조제에 관한 삼차원적 연구)

  • Kim Hyeong-Seop;Shin Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.191-203
    • /
    • 2005
  • Statement of problem. In Korea, the preliminary impression trays for dental and edentulous maxillae are manufactured on the base of the statistical value of Westerners. There had been less study on the dental and edentulous arches of Koreans. Purpose. The purpose of this study was to evaluate an average dental cast, preliminary impression trays, three-dimensional relation of dental and edentulous maxilla of Koreans Material and methods. The subjects for this study were 173 dental casts of maxilla (dental: 52, edentulous : 146) with ages $18\{\sim}60$ years old. Each of the master casts was measured 69 measuring points on the dental cast or maxilla, and 46 measuring points on the edentulous cast of maxilla with three-dimensional digital measuring machine. Each measuring points were analysed and were overlapped, that three dimensional dental graphic manufactured by CAD/CAM system. Results. 1. A standard of distribution to alveolar bone were width between left and right buccal border lines of the standard 3/4 line. The mean value of dental and edentulous casts were 67.27mm, 63.49mm respectively. 2. Morphological classification of dental casts were divided into three groups or V-shape, O-shape, U-shape, that proportion of distribution were 17%, 16%, 67%, respectively. Dimensional classification of the dental casts were divided into five groups of less than 63mm, 63 up to 65mm, 65 up to 67mm. 67 up to 69mm, more than 69mm, respectively. 3. Morphological classification of edentulous casts were divided into three groups or V-shape, O-shape, U-shape, that proportion of distribution were 18%, 17%, 65%, respectively Dimensional classification of the edentulous casts were divided into five groups of less than 57mm, 57 up to 61mm, 61 up to 65mm, 65 up to 69mm, more than 69mm, respectively. 4. Mean dental and edentulous cast of maxilla were overlapped, the proportion of bone resorption to alveolar bone is higher than that of palatal bone, its difference were higher anterior 2/4 area than posterior 3/4 area. Conclusion. It obtains information of preliminary impression trays for dental and edentulous maxilla of Koreans.